INDIRECTTM. Cubic INDIRECT INDIRECT/CUBIC INDIRECT

Similar documents
Towne Commons. A r c h i t e c t u r a l A r e a L i g h t i n g

Metal Halide - Ceramic, Medium Base ED17. H050 50w H070 70w H w H w HPS - Medium Base ED17

S u n V a l l e y L i g h t i n g S I G M ATM PATENT PENDING

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances.


Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

_ PR020 Series. Lamping. Color. SA Stake Mount K NOL Lamp not included. Single Pole Top Double Pole Top Triple Pole Top Quad Pole Top

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

Beam Pattern. Lamping C K (coated lamp) NOL Lamp not included C737 NOL. Lamp not included K (clear lamp) NOL

A R E A & S I T E WA L L M O U N T E D F LO O D B O L L A R D S

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

DV28. This light can be surface. DV28 technical specifications

Catalog Number LSBT. Example: LSBT6C8T5WD1-BZ QMB. Optics. Type II Type III Type IV Type IV Automotive Type V Medium Type V Wide T2 T3 T4 T4A T5M T5W

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood

Project: Type: Qty: QH2L. Series Optics Mounting Light Engine CCT Finish Voltage Option. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole.

A family of architectural luminaries for the security and comfort of people in outdoor spaces. Classics Series

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

Designed for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series

HPV Luminaire High Performance Vertical Lamp Luminaire Featuring CosmoPolis and MasterColor Elite Electronic Systems

Olivio Grande LED Candelabra Pole Top

AERODOME PARKING/ROADWAY (TYPE III)

PentaFlood Versatility

Olivio Medio LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4

5G350 Nominal 33W 5G530 Nominal 48W 5G700 Nominal 64W 5G105 Nominal 97W 5G140 Nominal 126W K K. 1 DM or HL only. Cannot be combined.

Catalog Number UPC Number

Catalog Number UPC Number

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Type. Listings: The luminaire is NRTL certified to UL 1598 and 8750 standards for wet locations. CSA 22.2#

Catalog Number UPC Number

NEW. Lumenfacade Remote. Lumenfacade Stand. Alone NEW NEW. Lumenfacade Remote. LumenfacadeFX RGB. Lumenfacade. Lumenfacade Interior RGB RGB RGB NEW

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

CH_Optra by Keene_NEW 11/1/05 7:42 PM Page 1. Optra Series

Baymaster LED Luminaire High Bay for Hazardous Locations

Olivio Grande LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

Ceramic Metal Halide Lighting

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

High performance RGB facade LED luminaire

OPTX PRECISION GUIDED LIGHTING TECHNOLOGY

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

4000 Watt - Metal Halide - Three Stage Light Tower - 30 Feet

DECORATIVE. Prismasphere

LED SERIES SPECTACOLOUR FLOOD RGB SPECTACOLOUR FLOOD RGB

EKG TYPE 5 CONVENTIONAL SHOEBOX LUMINAIRES

GEOMETRIC SERIES A R E A & S ITE RECTILINEAR SQUARE ROUND

6 FT LED Bulb - T8-36W Lumens - UL Listed - Fluorescent T8 LED Replacement/Retrofit Lamp

Evolve LED Roadway Lighting

VOLTAGE 1-120V. LAMP L-Lamp furnished

THE HILTON SERIES. Vertical Burn Performance, Flat or Contoured Lenses Available in 3 Sizes: 100 Up to 1000 Watts

HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

DISCONTINUED. LTV10 Series Composite Housing Accent. Specifications. Lightvault. Type: Job: Catalog number: Approvals: Fixture Options: / / /

INSTALLATION INSTRUCTIONS

Introduction Shank Road Pearland, Texas Fax:

18 Watt LED Bulb - 48 Inch Length - G13 T8 Style Tube - UL Listed - LEL Approved

ASA-128G1 and 160G1 Series

5 Watt LED Light Bulb - A19 Style Replacement for 60 Watt Incandescent E26 Light Bulbs

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

AREA LIGHTING. American. LumenStar Pages 2-3 Pages 6-7. OrbiStar Pages American Round Pages AREA. AutoLux

SpecificationS. Architectural Down Lighting Fixtures

DECORATIVE. Washington Series

SECTION LIGHTING

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

Exterior Decor LIGHTING. Bulkheads. architectural lighting. See our Bulkhead family sizes. Over 50 styles to choose from.

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Mozart Lantern TM New Elegance in Area and Street Illumination State-Of-The-Art HID and LED Performance.

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

Color and Color Temperature Additive RGB, Additive RGB + white 4000K, Additive RGB + amber. Optics (nominal distribution) 5, 6, 10, 20, 40, 60

EXTERIOR LIGHTING DESIGN

BVP SERIES Brass Lighting for Marine and Hazardous Environments

Classic DETAILS CL41P1 IP66 CL41P1

ASW with Emergency Battery Backup (EBB)

PRELIMINARY. 2700K, 3000K, 3500K, 4000K, Static Red, Static Green, Static Blue, Static Amber

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

High Performance Area/Site Lighting. Cimarron DIE CAST ARCHITECTURAL LUMINAIRE. Reflectors. High Performance Reflectors

EYE Lamps & Luminaires for Retail Applications

RADIANT LED AREA LIGHTING

GE Evolve LED Post Top Avery StreetDreams (EPAS)

PAYBACK STARTS NOW INDUSTRIAL LIGHTING PRODUCT CATALOG

Colour and Colour Temperature. Optics (nominal distribution) Illuminance at Distance

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

BULBS PLUS, INC. FEATURED PRODUCTS

Partnering with your design

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

APPENDIX H. Town of Oakville. Street Lighting Standard. Ora t 1.0 (]) OAKY I LLE

January 27, Our Product Offering

DETAIL SPECIFICATION SHEET LOUDSPEAKER, SHIPBOARD ANNOUNCING SYSTEMS ENCASED, 70 VOLT, 6 TO 15 VOLT-AMPERES

Cree Edge Series LED Area/Flood Luminaire

OPTICAL FINISH OPTIONS

Classic DETAILS CL41P1 IP66 CL41P1

28 Watt LED Bulb - 4ft T5HO LED Lamp Lumens - Replacement or Upgrade for Fluorescent Lights

Interior Accent. Lighting. Kaleidoshade 2

VT & VTTB SERIES. Comfortably illuminates the participants while rendering an excellent video image.

LUXTRAN Luminaires for Tunnel Applications

10 Million Candlepower LED Spotlight - 36 Watt - Pistol Grip Foot Beam Lumens

ARCHITECTURAL FLOOD LIGHTING. Precision Light. Infinite Possibilities

Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens

Decorative luminaires for open ceiling commercial and retail applications. Indy Commercial/Retail Lighting

Transcription:

INDIRECTTM Cubic INDIRECT TM A R C H I T E C T U R A L A R E A L I G H T I N G INDIRECT/CUBIC INDIRECT 1

to create, inspire and nurture EXCELLENCE in each other ENERGY EFFICIENCY The light sources employed in the Indirect family of fixtures are the most efficient sources commercially available today. The reflectors are designed to direct the illumination on the ground with no stray light which translates into wasted energy. The result is more light with less energy consumption. CONTENTS LIGHT POLLUTION The Indirect family of fixtures is designated as a cutoff fixture with only 1% of light emitted above 90 degrees horizontal. Elevated Scale 6 Illumination 8 Order Information - Cubic Indirect 10 Specification - Cubic Indirect 12 Installation - Cubic Indirect 13 Order Information - Indirect 14 Specification - Indirect 16 LONGEVITY AAL manufactures all its products to have a life span as long as the building or space they illuminate. The primary material used for all our products is aluminum to resist corrosion and the need for maintenance. Aluminum will not need the periodic refinishing required of steel products that will eventually rust and corrode. All our internal parts and fasteners are made of aluminum or stainless steel. The lamp enclosures are kept dust free and dry to prevent light degradation and maintain a high level of energy efficiency. SUSTAINABILITY AAL develops our products with recycling and resource management in mind. We recycle all incoming packaging materials. Our products are shipped in easy to recycle packaging materials. Our state of the art finishing system uses eco friendly cleansing and preparation chemicals that are harmless enough to send to the drain without further processing. Our powder coating process eliminates the release of volatile chemicals into the atmosphere. AAL makes the Indirect, like all AAL products, with renewable materials such as aluminum and stainless steel. Installation - Indirect 17 AAL is a registered continuing education provider. 2 The Indirect TM is registered and protected by numerous patents granted by the United States Patent Office. U.S. Patent D468,478; D601, 291 ARCHITECTURAL AREA LIGHTING 2009 Architectural Area Lighting. Printed on recycled paper.

TM An indirect luminaire that employs the most efficient sources commercially available. The INDIRECT family of fixtures is perfect for projects that require a sense of mood as much as a sense of light. I NDIRECT/CUBIC INDIRECT 3

INDA-WMA 4 INDC WMA2 ARCHITECTURAL AREA LIGHTING

The Indirect family features three distinct designs. The Cubic Indirect features an angular design that is a perfect complement to the rectilinear and angular compositions of modern architecture. Cubic Indirect wall mount INDC Cubic Indirect post top INDC The Indirect features a straight fixed head for a clean look, and an adjustable head for aiming the light when the upper reflector is titled. Indirect straight fixed head INDF Indirect adjustable head INDA All three models feature stainless steel vertical struts and can be configured with a round or square upper reflector. I NDIRECT/CUBIC INDIRECT 5

Specifications elevatedscale 18 15 12 9 6 3 FIXTURE INDC INDC INDC REFLECTOR SQ RD SQ MOUNTING WMA2 PTS4 PMAT2 POLE PS4-4S14 DB6-4R16 6 ARCHITECTURAL AREA LIGHTING

elevatedscale INDF 2-INDA INDF SQ SQ RD PMAT WMA PR5-5R12, BC5-5 DB10-5R16 with AD5 I NDIRECT/CUBIC INDIRECT 7

Specifications illumination Egress The Cubic Indirect s emergency lighting option, in the wall mount version, illuminates corridors, building entrances and exterior passages for added safety and security. The hidden MR16 lamp, powered as a remote head, is able to be angled 15 in either direction, and provides code-required 1 footcandle path-of-egress illumination, from the building toward the common way. The Cubic Indirect eliminates the need for secondary fixtures used as emergency egress lighting. All emergency lighting options are installed in the housing, thereby eliminating external compartments or secondary fixtures which result in extra material and labor costs. Egress Dark Sky Friendly Other indirect luminaires typically throw 40 to 50 percent of their light output upwards into the sky. The result is poor efficiency as well as light pollution. The Indirect s specially designed lower reflector precisely focuses the light energy onto the upper reflector with virtually no stray uplight. The Indirect and Cubic Indirect emits one percent upward, earning an IES cutoff luminaire classification from an independent photometric testing lab. AAL Indirect 1% uplight IES cutoff luminaire Others 40 to 50% uplight IES non-cutoff luminaire AAL Indirect 8 ARCHITECTURAL AREA LIGHTING

illumination Reflector Adjustment The Indirect and Cubic Indirect upper reflector can be tilted 15 or 30 degrees for an asymmetrical light distribution. The locking clamp design ensures a consistent tilt angle on all fixtures. The Indirect model INDA has an adjustable lamp head to focus the light beam onto the center of the shade, when the shade is tilted. This improves efficiency and minimizes any stray light beyond the reflector. Horizontal position Type 5 symmetric light pattern 15 tilt position asymmetric light pattern 30 tilt position asymmetric light pattern I NDIRECT/CUBIC INDIRECT 9

orderinfo Specifications cubic indirect 1 2 3 4 5 6 FIXTURE REFLECTOR-UPPER LAMP/BALLAST MOUNTING OPTIONS COLOR INDC RD CF WMA2 CDC BLK 30 in/750 1. FIXTURE INDC Square straight, fixed head. Post top mount. Slips over a 2 3/8 inch O.D. tenon (5 in/127 mm square pole) or a 4 in/100 mm square pole. 24.0 24 in/600 mm 2. REFLECTOR - UPPER RD SQ 30 inch round upper reflector 30 inch square upper reflector u u u 3. LAMP/BALLAST RD SQ CF Electronic 120 thru 277 volt ballast. -18 C starting temp. Use 4-pin 26, 32 or 42 watt lamp. 70MH 70 watt metal halide 120/208/240/277 volt ballast. Use medium base, ED-17 lamp. 70MHEB 70 watt electronic metal halide 120 thru 277 volt ballast. Use medium base, ED-17 lamp. 70MHT6 70 watt metal halide 120/277/347 volt ballast. Use G12 base, T6 ceramic lamp. 70MHT6EB 70 watt electronic metal halide 120 thru 277 volt ballast. Use G12 base, T6 lamp. 100MH 100 watt metal halide 120/208/240/277 volt ballast. Use medium base, ED-17 lamp. 150MHEB 150 watt electronic metal halide 120 thru 277 volt ballast. Use medium base, ED-17 lamp. 150MHT6EB 150 watt electronic metal halide 120 thru 277 volt ballast. Use G12 base, T6 lamp. 150PSMH Pulse start 150 watt metal halide 120/208/240/277 volt ballast. Use medium base ED-17 lamp. 150PSMHT6 Pulse start 150 watt metal halide 120/208/240/277 volt ballast. Use G12 base, T6 ceramic lamp. 70R111 70 watt metal halide 120/277 volt ballast. Use R111 lamp. 70R111EB 70 watt electronic metal halide 120/277 volt ballast. Use R111 lamp. 30LED-WW 30 light emitting diode array (33 watt). Warm white (3000K). 120 thru 277 volt. 30LED-NW 30 light emitting diode array (33 watt). Neutral white (4000K). 120 thru 277 volt. 30LED-BW 30 light emitting diode array (33 watt). Bright white (5000K). 120 thru 277 volt. All ballasts are factory wired for 277 volts. Lamps not included 10 ARCHITECTURAL AREA LIGHTING

orderinfo cubic indirect 1 2 3 4 5 6 FIXTURE REFLECTOR-UPPER LAMP/BALLAST MOUNTING OPTIONS COLOR INDC RD CF WMA2 CDC BLK 4. MOUNTING Must choose one WMA2 WMA2-NEG PMAT2 PTS5 PTS4 12" Wall mounted arm, 10 lbs. Features built in MR16 egress (50 watt). Wall mounted arm, 10 lbs. No egress lamp. Blocked opening. Twin pole mount arm, slips over a 4 in/100 mm O.D. pole or tenon. Post top mount slips over a 2 3/8 inch O.D. round tenon (5 in/127 mm square pole) 4 7/8" 2X O 7/16" 6" 9" Post top mount 14 slips 11/16" over a 4 in/100 mm square pole 5.5 in/138 mm 5 1/16" 3 in/76 mm 33 in/838 41.4 in 1035 mm WMA2 5. OPTIONS CDC SR CFH LAMP R111 Center deflector cone for round reflector. Provides a wider light distribution. Two aluminum rings attached to the fixture. Factory installed. Color filter holder attached to the fixture includes solid rings. Factory installed. 70 watt metal halide R111 reflector lamp. 6. COLOR All standard and premium AAL colors available. For RAL and custom colors, please submit a 4-digit RAL number or color chip for custom colors. I NDIRECT/CUBIC INDIRECT 11

Specifications specifications cubic indirect 30 in/750 mm SAFETY The wall mounted luminaire (WMA2) includes an integral secondary source to provide code-required 1 footcandle emergency path-of-egress illumination from building to the public way. The hidden MR16 lamp, powered as a remote head, is able to be angled up to 15 in either direction. 41.4 in/1035 mm 2424.0 in/600 mm ELECTRICAL MODULE The ballast is mounted on a pre-wired plate with a quick disconnect plug. Magnetic metal halide ballasts are high power factor, rated for -30 C starting. Electronic metal halide ballasts are rated for -30 C starting, sound rating A, 120 thru 277 volt. Sockets are pulse rated porcelain for medium base ED-17; bi-pin, G12 for T-6 lamps; GX8.5 for R111. The compact fluorescent shall have an electronic transformer, 120 thru 277 volt. WT: 45.9 lbs. EPA: UPPER REFLECTOR The upper reflector shall be light weight aluminum composite. The reflector shall be finished in a white, fluoropolymer finish. The reflector shall be attached to the cast aluminum pivot joints and secured with four stainless steel bolts. Two cast aluminum, adjustable knuckles shall connect the reflector assembly to the vertical, stainless steel struts. The struts are #316 stainless steel with a minimum.075 inch wall thickness. The struts shall be clamped in place with 5/16-18 set screws for attachment to the upper reflector and the lamp module. LAMP MODULE The reflector shall be enclosed in cast aluminum housing. The front cover is secured with four cap screws for re-lamping and internal access. The top glass element is clear, tempered glass. The top cover and electrical module are sealed with memory retentive, molded silicone gaskets. The parabolic reflector shall be pre-focused to illuminate the upper reflector with no stray light beyond the reflector. All internal and external hardware is stainless steel. HOUSING INDC-SQ u Sail: u 0 = 1.70 15 = 3.27 30 = 5.01 INDC-RD Sail: 0 = 1.46 15 = 2.89 30 = 4.28 The post top model shall slip over a 2 3/8 inch O.D.tenon (5 in/127 mm square pole) or 4 in/100 mm square pole. FINISH Fixture finish consists of a five stage pretreatment regimen with a polymer primer sealer, oven dry off and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance. The reflector shall be painted white. The lens frame shall be painted black to further control any up light. The vertical struts are stainless steel. All other fixture parts shall be finished in the same specified color. CERTIFICATION The fixture shall be listed with ETL and U.L. for outdoor, wet location use, UL1598 and Canadian CSA Std. C22.2 NO.250. IP=66 WARRANTY Fixture is warranted for three years. Ballast components carry the ballast manufacturer s limited warranty. Any unauthorized return, repair, replacement or modification of the Product(s) shall void this warranty. This warranty applies only to the use of the Product(s) as intended by AAL and does not cover any misapplication or misuse of said Product(s), or installation in hazardous or corrosive environments. Contact AAL for complete warranty language, exceptions, and limitations. Note: The Cubic Indirect is not suitable for high wind loading areas. Do not install these products between buildings or other unusual zones where wind may exceed normal loads. 12 ARCHITECTURAL AREA LIGHTING

installation cubic indirect Tool-less access to integral ballast assembly Hidden MR16 lamp in wall mount (WMA2) provides code-required 1 foot candle emergency path-ofegress illumination Lens frame painted black to further control uplight I NDIRECT/CUBIC INDIRECT 13

orderinfo indirect 1 2 3 4 5 6 FIXTURE REFLECTOR-UPPER LAMP/BALLAST MOUNTING OPTIONS COLOR INDF RD 70MH WMA CDC BLK 1. FIXTURE INDA INDF Adjustable head. Slips over a 5 in/127 mm O.D. pole. Fixed head. Slips over a 5 in/127 mm O.D. pole. 28.4 in 720mm 32 in 815m 815mm 2. REFLECTOR - UPPER INDA INDF RD SQ 30 inch round upper reflector 30 inch square upper reflector 3. LAMP/BALLAST RD SQ CF Electronic 120 thru 277 volt ballast. -18 C starting temp. Use 4-pin 26, 32 or 42 watt lamp. For INDA - 26 watts only. 70MH 70 watt metal halide 120/208/240/277 volt ballast. Use medium base, ED-17 lamp. For INDF model only. 70MHEB 70 watt electronic metal halide 120 thru 277 volt ballast. Use medium base, ED-17 lamp. For INDF model only. 70MHT6 70 watt metal halide 120/277/347 volt ballast. Use G12 base, T-6 ceramic lamp. 70MHT6EB 70 watt electronic metal halide 120 thru 277 volt ballast. Use G12 base, T-6 ceramic lamp. 100MH 100 watt metal halide 120/208/240/277 volt ballast. Use medium base, ED-17 lamp. For INDF model only. 150MHEB 150 watt electronic metal halide 120 thru 277 volt ballast. Use medium base, ED-17 lamp. For INDF model only. 150PSMH Pulse start 150 watt metal halide 120/208/240/277 volt ballast. Use medium base ED-17 lamp. For INDF model only. 150PSMHT6 Pulse start 150 watt metal halide 120/208/240/277 volt ballast. Use G12 base, T6 lamp. 30LED-WW 30 light emitting diode array (33 watt). Warm white (3000K). 120 thru 277 volt. 30LED-NW 30 light emitting diode array (33 watt). Nutral white (4000K). 120 thru 277 volt. 30LED-BW 30 light emitting diode array (33 watt). Bright white (5000K). 120 thru 277 volt. All ballasts are factory wired for 277 volts. Lamps not included 14 ARCHITECTURAL AREA LIGHTING

orderinfo indirect 1 2 3 4 5 6 FIXTURE REFLECTOR-UPPER LAMP/BALLAST MOUNTING OPTIONS COLOR INDF RD 70MH WMA CDC BLK 4. MOUNTING WMA Wall mounted arm, 10 lbs. EPA: 0.68 PMAT Twin pole mount arm, slips over a 4 in/100mm O.D. pole or tenon, 14 lbs. EPA: 0.83 4 in/100mm 4 in/100mm 34 in/865mm 34 in/865mm WMA PMAT 5. OPTIONS CDC SR CFH LAMP70 LAMP150 AD5 Center deflector cone for round reflector. Provides a wider light distribution. Two aluminum rings attached to the fixture. Factory installed. INDA only. Color filter holder attached to the fixture. Factory installed. INDA only. Philips 70 watt clear T-6 ceramic metal halide lamp, CDM70/T6/830 Philips 150 watt clear T-6 ceramic metal halide lamp, CDM70/T6/830 Cast aluminum adapter for the PMAT arm to slip over a 5 in/127 O.D. mm pole 6. COLOR All standard and premium AAL colors available. For RAL and custom colors, please submit a 4-digit RAL number or color chip for custom colors. I NDIRECT/CUBIC INDIRECT 15

specifications indirect 28.4 in 720 mm 32 in 815m mm ELECTRICAL MODULE The ballast is mounted on a prewired plate with a quick disconnect plug. Magnetic metal halide ballasts are high power factor, rated for -30 C starting. Electronic metal halide ballasts are rated for -30 C starting, sound rating A, 120 thru 277 volt. Sockets are pulse rated porcelain, bi-pin, G12 for T-6 lamps. A porcelain screw base for the mini-cand T-4 halogen lamp. The compact fluorescent shall have an electronic transformer, 120 thru 277 volt. UPPER REFLECTOR The upper reflector shall be a light weight aluminum composite. The reflector shall be finished in a white, fluoropolymer finish. The reflector shall be attached to the cast aluminum pivot joints and secured with four stainless steel bolts. Two cast aluminum, adjustable knuckles shall connect the reflector assembly to the vertical, stainless steel struts. The struts are #304 stainless steel with a minimum.250 wall thickness. The struts shall have threaded connections for attachment to the upper reflector and the lamp module. LAMP MODULE The reflector shall be enclosed in cast aluminum housing. The front cover is secured with four cap screws for relamping and internal access. The front glass element is clear, tempered glass. The front cover and electrical module are sealed with memory retentive, molded silicone gaskets. The parabolic reflector shall be prefocused to illuminate the upper reflector with no stray light beyond the reflector. The fixture shall be IES rated as a cutoff. The INDA model lamp module swivels, to center the beam on a tilted reflector, by loosening two stainless steel cap screws. All internal and external hardware is stainless steel. HOUSING The INDA and INDF post top models shall slip over a 5 in/127 mm O.D. pole. FINISH Fixture finish consists of a five stage pretreatment regimen with a polymer primer sealer, oven dry off and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance. The reflector shall be painted white. The vertical struts are stainless steel. All other fixture parts shall be finished in the same specified color. CERTIFICATION The fixture shall be listed with ETL and U.L. for outdoor, wet location use, UL1598 and Canadian CSA Std. C22.2 NO.250. IP=66 EPA: INDA or INDF round upper reflector/ 0 tilt: 3.65 square upper reflector/ 0 tilt: 4.40 round upper reflector/ 30 tilt: 6.52 square upper reflector/ 30 tilt: 6.62 WARRANTY Fixture is warranted for three years. Ballast components carry the ballast manufacturer s limited warranty. Any unauthorized return, repair, replacement or modification of the Product(s) shall void this warranty. This warranty applies only to the use of the Product(s) as intended by AAL and does not cover any misapplication or misuse of said Product(s), or installation in hazardous or corrosive environments. Contact AAL for complete warranty language, exceptions, and limitations. Note: The Indirect is not suitable for high wind loading areas. Do not install these products between buildings or other unusual zones where wind may exceed normal loads. 16 ARCHITECTURAL AREA LIGHTING

installation indirect Lightweight aluminum composite reflector reduces pole stress Reflector tilts and locks at 15 0 or 30 0 Adjustable head (INDA) tilts to center the beam onto the reflector. The parabolic reflector focuses the light beam into the upper reflector for maximum efficiency Also available with fixed head for streamlined look I NDIRECT/CUBIC INDIRECT 17

INDF INDA INDC-PTS4 18 ARCHITECTURAL AREA LIGHTING

INDA INDA I NDIRECT/CUBIC INDIRECT 19

INDIRECT TM Cubic INDIRECT TM 20 Architectural Area Lighting 16555 East Gale Ave. City of Industry CA 91745 T 626.968.5666 F 626.369.2695 www.aal.net/aal/indindc110.html ARCHITECTURAL AREA LIGHTING 2010 Architectural Area Lighting Design Patents Made in the USA INDIRECT/CUBIC INDIRECT 110