Magtech Voltage Booster MVB

Similar documents
Magtech Voltage Booster MVB

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Automatic capacitor banks with detuned filters

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

86 chapter 2 Transformers

3-Phase Transformers. Author: Sergey Dubatov. belfuse.com/signal

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

CONTENTS. 1. Introduction Generating Stations 9 40

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

HPS Universal BUCK-BOOST TRANSFORMERS

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Automatic capacitor banks with detuned filters

Aggravation with voltage?

TOSHIBA International Corp

Arc Suppression Coils

Spring 2000 EE361: MIDTERM EXAM 1

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

~=E.i!=h. Pre-certification Transformers

ELECTRICAL POWER ENGINEERING

Preface...x Chapter 1 Electrical Fundamentals

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Electrical Description

Technical Data Sheets

Example of Transformer Connections and Ground Currents

ahead of time Static Digital Voltage Stabilisers

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Univerter-MV. Medium Voltage Variable Speed Drive

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Series P. Applications

Power systems 2: Transformation

ELECTRODYNAMIC VOLTAGE STABILIZERS

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

USER S MANUAL. 1KSS60400/ ST Edition

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Product Data Bulletin

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

VOLTAGE OPTIMIZATION FOR INDUSTRY, TRADE, BUSINESS AND LOCAL NETWORKS

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Electromagnetic Harmonic Filters Technical Guide

Realisation of the galvanic isolation in customer-end DC to AC inverters for the LVDC distribution

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

TOMI HAKALA THE UTILIZATION POTENTIAL OF LVDC DISTRIBUTION IN THE VATTENFALL DISTRIBUTION NETWORK

R Distribution Transformers. Mineral Oil-Immersed, Self-Cooled, 60 Hertz Voltages and Connections. Reference Data

BUCK-BOOST TRANSFORMERS

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

StacoDVR-5 60kVA to 6000kVA

ELECTRICAL POWER TRANSMISSION TRAINER

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Installation and Operating Instructions. Power IT Power Factor Controller RVC

BAT-Series Grid Inverter. Battery Charger.

Warehouse Stock Transformers

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Single Line Diagram of Substations

Spänningsstabilisatorer Voltage Stabilisers. General information

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Switching power supplies CP range, Linear power supplies CP-L range. Content

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)


Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Thyristorised Automatic Power Factor

Single-Phase Transformation Review

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

English 8 P EN.01/01.

NESSY NETWORK VOLTAGE STABILISATION SYSTEM. Permanent protection against voltage fluctuations in the low-voltage network

Power transformers for Network, Rectifiers, Furnace

TRANSFORMER OPERATION

Low Pass Harmonic Filters

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

Power Conditioners product guide

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

3Ø Short-Circuit Calculations

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

USER S MANUAL. 3KSS6050/ nd Edition

Est Static Frequency Converter. SFX 10kVA - 10MVA

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Unit 2. Single Line Diagram of Substations

Introduction. A closed loop of wire is not an electrical circuit, a circuit requires

COMMISSION REGULATION (EU) No /.. of XXX

TECHNICAL INFORMATION

Line Frequency Transformer

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

B9000 FXS kVA B9600 FXS kVA

Transcription:

Model overview MVB 30.04.09 EG.doc Magtech Voltage Booster Voltage fluctuations caused by unbalanced load in Y-ground grid? Low voltage part of the day due to high load? Quick and profitable solution with Magtech Voltage Booster Easy planning, simple installation and robust design Simplified free Excel planning tool Patented design & solution http://www.magtech.no/ Patent nr.: O 317045 US 6,788,180 B2 Tel.: +47 69 27 92 00 Fax: +47 69 27 92 22 www.magtech.no Reidar.Tjeldhorn@magtech.no Espen.Haugs@magtech.no Karl.Borgerud@magtech.no

Model overview MVB 30.04.09 EG.doc Magtech Voltage Booster MVB Power Quality Lifts and stabilizes voltages for each phase individually. Corrects unbalanced voltages (symmetrical) Increases single pole short circuit capacity with typically 60 % or more for Y-ground network Voltage is not influenced if -conductor is disconnected This is solved by a patented balance winding Fast regulation; 100 ms for a typical load change Robust 25 years designed lifetime - o moving parts or semiconductors in the power circuit The patented MCI, Magtech Controllable Inductor a design with mainly copper and iron in power circuit Galvanized casing for outdoor use Oil cooled, standard transformer oil, optional with organic decomposable oil Hermetically sealed with overpressure valve Over voltage protected Safe Bypass contactor ensures fail safe (no power interruptions) at overload or faults Returns automatically to operation when fault is not present (e.g. high temperature, overload) Increases one pole short circuit capacity in ground Y networks. Ik1 increased by more than 60% Option: electronic circuit breaker on output takes care of very low short circuit levels

Model overview MVB 30.04.09 EG.doc Proven Developed in close cooperation with several electric utilities (a.o. Vattenfall Eldistribution AB, Hafslund ett AS) In compliance with E50160 and CE-marking for domestic use A large number of units installed in Scandinavia, first pilot installed 2003 Quick installation Easy to install in one day Pole mounted, no housing required, one or two poles Ground mounted, no housing required Free planning tool (Excel) available on www.magtech.no Areas of application Stabilizing voltage for long LV lines or sea cables. Supporting telecom base station transmitters for GSM and UMTS, vacation homes, weekend cottages, rural homes and stores, farms, fish farms, production plants etc. Provisional power supply for construction areas, tunnels etc. Stabilizing voltage in the grid when voltage fluctuation is caused by distributed generation like solar cells, hydropower or windpower-plants. Stabilizing and lifting voltage on the LV side, when voltage drop is caused on 1kV or higher. For ground cables in rural or densely populated areas. Mounted on the ground or on poles.

Technology Model overview MVB 30.04.09 EG.doc MCI - Magtech Controllable Inductor Magtech has developed a patented magnetically adjustable inductor with an exceptional efficiency and large control range. The MCI is produced with copper and iron. R Input Output U The main copper winding on the outside produce AC flux lines in the core. A hidden control winding on the inside produces DC flux lines 90 on the main flux lines. The amount of DC flux sets the inductance value in the main winding. S V MCI - new symbol Magtech has drawn a new symbol for this new component. T W Because of its special construction, two inductors are indicated with a common iron core, 90 angle between them. Booster topology Three phase MVB Input Output The MCI is connected to an auto transformer. This picture shows one phase. By adjusting the inductance value in the MCI, the voltage over the autotransformer automatically changes accordingly. By controlling the voltage over the autotransformer, an extra voltage vector is added to the output and enables active lifting of the output voltage. Three regulators. The booster topology is repeated for all three phases. Electronic regulator cards measures phase-to-neutral voltage, and controls each MCI and lifts all phase voltages to a correct value individually. Balance winding. The MVB has a patented balance winding (drawn red) between all phases to help stabilizing the voltages. In addition to stabilizing, the balance winding also increase the one pole short circuit capacity considerable both in front and behind of the booster. Bypass. If the voltage output of the MVB is detected to be less than 190 volts, a 3-pole contactor bypasses the secondary winding of the autotransformers. This also happens if the booster has been overloaded and high temperature is detected. The MVB automatically restarts when the situation is over.

Technical data Model overview MVB 30.04.09 EG.doc Model MVB40-230 MVB125-230 MVB250-230 MVB40-400 MVB125-400 MVB250-400 MVB40-380 MVB125-380 Distribution system connection IT / TT IT / TT IT / TT T T T T T Frequency [Hz] 50 50 50 50 50 50 50 50 Voltage [volts] (3 phase) 230 230 230 230 / 400 230 / 400 230 / 400 220 / 380 220 / 380 Load, nominal [kva] 10 32 65 17 55 112 17 53 Load, 6 hours, @20 C, input voltage 195 V [kva] 16 50 100 28 87 170 26 82 Current nominal [ampere] 25 80 160 25 80 160 25 80 Current, 6 hours, @20 C, input voltage 195 V [ampere] 40 125 250 40 125 250 40 125 Voltage set point [volts] 235 235 235 235 235 235 225 225 Voltage lift [%] 0-17 0-20 0-10 0-20 0-20 0-10 0-20 0-20 Dynamic response [milliseconds] 150 200 200 150 200 200 150 200 o-load loss [watts] 200 340 340 200 340 340 200 340 Efficiency [%] 1 94-96 94-96 94-96 96-97 96-97 96-97 96-97 96-97 Power factor [cos ϕ] 1 0,96-0,97 0,96-0,97 0,96-0,97 0,98-0,99 0,98-0,99 0,98-0,99 0,98-0,99 0,98-0,99 Total Harmonic Distortion [%] 1 1-4 1-4 1-3 1-6 1-6 1-4 1-6 1-6 Mechanical dimensions Width x Height x Depth [mm] 754x928x539 1003x1190x648 1003x1190x648 754x928x539 1003x1190x648 1003x1190x648 754x928x539 1003x1190x648 Weight [kg] 390 750 750 390 750 750 390 750 Cable connection [Copper mm 2 ] 16 50 70 16 50 70 16 50 Oil filled [liters] 75 158 158 75 158 158 75 158 Enclosure oil filled Galvanized Galvanized Galvanized Galvanized Galvanized Galvanized Galvanized Galvanized Features Bypass @ U_out ±15% or high temp - o voltage interruption - Automatic restart One controller per phase - individual regulation of phases Handles 100% unbalanced load and maintains the voltage Single pole short circuit capacity increased by a minimum of 60% 50% 50% 50% unchanged unchanged unchanged o moving parts in the power circuit Maintenance free 25 years designed lifetime Quick installation < one day Option: SSP = Short-Circuit Safety Protection, 3-pole circuit breaker installed on output, FR3 = Environmental friendly organic oil. 1 - nominal load, varying voltage boosting

Mechanical dimensions Model overview MVB 30.04.09 EG.doc Rear view Side view Rear view Side view 500mm 648mm 380mm 538mm 700mm 580mm 1003mm 754mm