SVM F22. Calculator for heating or cooling applications. Data sheet

Similar documents
SVM F27 Compact. Ultrasonic heatmeter. Data sheet

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

User s Manual. F2 Calculator. A metering component for thermal energy applications

SVM F22 SVM F27. Calculator for heating or cooling applications. Ultraljudsmätare. Installation Guide. Datablad

SVM F27 Compact. Compact heat meter. Users manual

Supercal 531 Multi function Integrator that lives up to Your highest expectations

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

INFOCAL 8 Energy calculator

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SonoMeter 31 Energy Meters

Brunata Optuna H. Properties. Counter

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Infocal 9 Energy calculator

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RAY MC COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL

MULTICAL Energy meter TS PTB. Application

RAY MC COMPACT ENERGY METER MECHANICAL

SonoSelect 10 and SonoSafe 10 Energy Meters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

MULTICAL 601 DATA SHEET

SONOMETER TM 1000 Ultrasonic compact heat meter

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

B850 Boiler House Energy Monitor

Position Indicator model MFC-300/IP. Technical Manual. Licht

Single phase meter with direct connection and pulse or Modbus RS485 output

ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.

PEM353. Universal measuring device

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

SINGLE PHASE STS PREPAID METER

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

3-phase meter with direct connection and pulse or Modbus RS485 output

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

SONOMETER 2000 Ultrasonic heat meter

Digital flowmeter for continuous flow measurement

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital flowmeter for continuous flow measurement

CONTROL MANUAL. Dry-Pic 09PE - 09VE

DPF-MAC Auto power factor controller

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

MULTICAL 602 DATA SHEET

AEROCONNECT 1B NA C Control manual

ULTRASONIC D. Compact ultrasonic heat meter

ULTRA RAPID POWER QUALITY ANALYZER

Heat meter Q heat 5 US

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

WESAN WP E ELECTRONIC METER WOLTMAN

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

PLA 33. Power line analyzer. User and service manual. version 2.4

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

B850 Boiler House Energy Monitor

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

1-7. Product information Temperature Monitoring. Type: TMS U. Thermal control module:

HDU-SF (Horizontal Distribution Units - Single Flat)

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

Product Manual SE1000. Description The SE1000 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs.

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

PROCESS & TEMPERATURE CONTROLLERS

RUN MAN OUT1 OUT2 FL40

EPM Single-point submetering system. imagination at work. Engineered for retrofit and new construction with power line communication capability

Monitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

Installation, Operation and Maintenance Manual

ultego III smart plus

P5201 Universal Programmable Transmitters with Galvanic Isolation

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

R&D TECHNICAL SPECIFI

ME162 Single-Phase Electronic Meter

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

WIRELESS MODBUS GATEWAY WGW410

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Electronic Heating Energy Meters

Ultrasonic level transmitter, non-contact

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Valve Island with Electronic I/O

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

Technical Information RMS621

Transcription:

SVM F22 Calculator for heating or cooling applications Data sheet

Application area F22 is a flexible calculator designed for measuring and monitoring of small to medium-sized heating or cooling installations. It is dedicated for billing applications and protected with several tampering seals. Measurement F22 measures the volume and the difference between the supply and return temperatures. Measurements are normally done at each flow sensor pulse. F22 accumulates the volume from the flow sensor into a volume register. Display and data access F22 is equipped with a 7+2 digit LCD (Liquid Crystal Display). Measured and historical values, calculator settings and messages, can be read from the display. The data is easily accessed through a push-button on the front of the calculator. Example of a display image, showing accumulated energy. Different versions of F22 The F22 is delivered in a few versions to suit different applications and usage. The versions are: Basic version (B) Basic calculator can be equipped with an M-Bus (option board). Extended version (E) More advanced calculator with Alarm output, pulse inputs and outputs, and the possibility to add additional functions through factory mounted option boards. Communication The calculator is ready for system integration, with several different ways to communicate electronically. Pulse inputs or outputs** F22, E version is equipped with two pulse inputs. The pulses are accumulated into two pulse registers. The pulse input rate is selectable at ordering. The data can be retrieved both on the display and by using M-Bus communication. F22, E version is equipped with two pulse outputs, representing energy and volume. The outputs are of the type opencollector. At every time the last significant digit on the display is incremented one pulse is emitted (heating energy on pulse output 1 and volume on pulse output 2). Galvanic separation available as an option board. M-BUS output (as option board) F22 can be equipped with an M-Bus galvanic separated communication board. The M-Bus protocol is in accordance with international European standard EN1434-3, EN60870-5. The data can be accessed using a two-wire or an RS232 connection and an optical interface. The standard baud rate is 300 baud, but the calculator can also be ordered for 2400 baud on request. The board has a galvanic separation from the M- Bus loop. Displayed data Accumulated values Accumulated heat energy Accumulated (total) volume Accumulated volume according energy calculation Accumulated pulses pulse input 1 ** Accumulated pulses pulse input 2 ** Momentary values Momentary power Momentary flow Supply (High) temperature Return (Low) temperature Temperature difference Calculator settings Total operating time Time Date Selected pulse value Flow sensor placing (H/L) Calculator S/N number Communication, primary address Communication, secondary address (S/N) Calculator messages Error code Total error time Preceding error code Total time for preceding error code Recommended date for battery replacement Historical values Historical values are stored at the end of each month or period for account days. There are 37 monthly registers + 2 account days in the calculator. Accumulated heating energy Accumulated volume Accumulated volume according energy calculation Accumulated pulses pulse input 1 ** Accumulated pulses pulse input 2 ** Error code at saving Error time at saving Service / Installation F22 has a built-in service/installation function that enables the user to change the calculator settings using the push-button. Following settings can be modified by the push-button: Time Date Account day 1 Account day 2 Communication, primary address Flow sensor placing, high or low temperature Recommended date for battery replacement Reset error time Exit service menu F22 can also be parameterized by using a special PC-program FlexServ. Option boards The F22 can be equipped with option boards. Two option boards can be mounted after delivery. o M-Bus (galvanic separated) o Relay** (galvanic separated) o All other option boards must be factory mounted ** Only in the E version of F22

Technical data Flow sensor Frequency Max. 12 Hz Min. 40 ms Voltage Max. 3V Cable length Max. 15m Pulse value acceptable 0.0001 9999 l/p Temperature sensors Approved and matching pairs type Pt100 are to be used. Max cable length Min cable area 2.5 m 0.22 mm 2 5.0 m 0.50 mm 2 7.5 m 0.75 mm 2 Sensor current 4 µa (RMS) for Pt100 Temperature Range 0 190ºC Difference 2 120 K Ambient temperature Operation 5ºC 55ºC Storage/transport -20ºC 70ºC Protection Class IP54 Environmental class C according to EN1434 Power supply Battery 3.6V 2.75 Ah 1 Mains 230 V ± 10%, 45-65 Hz Battery as spare 1 Operation time max. 10 years. Display 7 + 2 digits LCD (backlight as option) Pulse Outputs** Type Open collector 250 ms Voltage Max. 30 V Current Max. 20 ma Pulse inputs** Frequency Max. 12Hz Min. 40 ms Voltage Max. 3V Alarm output** One pulse every hour as long as a mains power is cut (only mains supplied calculators). Type Open collector 250 ms M-Bus as option board ( Galvanic separation) Complies with EN1434-3 and EN60870-5 Two-wire connection** Option board Optical interface Enabled ** Only in E version of F22 Dimensions All dimensions are in mm Hole distance on F22 is the same as SVM RV8x. R 2.75 R 4.6 PG9/PR15.2(4x) 250 F22 140 92 112 71 96

Basic version [B] The basic version is optimized for small installations with limited functionality. F22 ABCDEFGHIJ KLM A 1 Pt100 2-wire measurement, flow in return (low) temperature A 2 Pt100 2-wire measurement, flow in supply (high) temperature B 1 Battery supply B 3 Mains supply 230VAC C 1 Kt Input 2.5 l/p C 2 Kt Input 25 l/p C 3 Kt Input 250 l/p C 4 Kt Input 2500 l/p C 5 Kt Input 1 l/p C 6 Kt Input 10 l/p C 7 Kt Input 100 l/p C 8 Kt Input 1000 l/p D 0 KWh D 1 MWh D 2 GJ E - Standard order E S Special, Extra information at the order, e.g. customer information F 9 No Pulse inputs or pulse outputs G 1 No Backlight H 0 For wall mounting I B Basic version J 1 No M-Bus J M M-Bus two wire connection (option board) J R RS232/M-Bus (option board) KLM X Country code, 300 = Standard English PL1 F22 Basic o Mains supply or battery supply o Robust design o Powerful calculator o Ample connection space o M-Bus option board (with galvanic separation) + + 3V M-BUS

Extended version [E] F22 extended version for more versatile usage. A calculator with pulse inputs, outputs, alarm outputs and option board functionality. F22 ABCDEFGHIJ KLM A 1 Pt100 2-wire measurement, flow in return (low) temperature A 2 Pt100 2-wire measurement, flow in supply (high) temperature B 1 Battery supply B 3 Mains supply 230VAC B U Battery supply + Battery supply U2500 C 1 Kt Input 2.5 l/p C 2 Kt Input 25 l/p C 3 Kt Input 250 l/p C 4 Kt Input 2500 l/p C 5 Kt Input 1 l/p C 6 Kt Input 10 l/p C 7 Kt Input 100 l/p C 8 Kt Input 1000 l/p D 0 KWh D 1 MWh D 2 GJ E - Standard order E S Special, Extra information at the order, e.g. customer information F A Pulse outputs, 2.5 l/p (+ pulse inputs), dec. 2 F B Pulse outputs, 25 l/p (+ pulse inputs), dec. 1 F C Pulse outputs, 250 l/p (+ pulse inputs), dec. 0 F D Pulse outputs, 2500 l/p (+ pulse inputs) F E Pulse outputs, 1 l/p (+ pulse inputs), dec. 3 F F Pulse outputs, 10 l/p (+ pulse inputs), dec. 2 F G Pulse outputs, 100 l/p (+ pulse inputs), dec. 1 F H Pulse outputs. 1000 l/p (+ pulse inputs), dec. 0 G 1 No Backlight H 0 For wall mounting I E Extended version J 1 No M-Bus J M M-Bus, two wire connection (option board) J R RS232/M-Bus board (option board) KLM x Country code, 300 = Standard English E PL1 PL2 IN 1 2 OUT 1 PL3 OUT 2 PL4 A 1 2 AL + F22 Extended o Can be ordered with mains supply or battery o Robust design o Powerful calculator o Connection box with room for future options o Ample connection space o U2500 pulse adjustment selectable o Two pulse inputs o Two pulse outputs (out 1, energy and out 2, volume) o M-Bus option board galvanic separated o Option board for pulse inputs / outputs with galvanic separation. The pulse input and output will be galvanic separated from each other. + + 3V M-BUS AL

F22 Article number key By combining the correct letters in the table below, the applicable article number for F22 will be obtained. Aricle number key for F22 Fill in the blanks to obtain the applicable article number. F22 A B C D E F G H I J K L M - 1 0 0 70 214 112 74 Hole distance on the F22 with cover is like RV9x Metrima AB Norra Stationsgatan 93 SE-113 64 Stockholm Phone: +46 8 23 60 30 Fax: +46 8 23 60 31 www.metrima.se info@metrima.se 3-02-09E 050316/MaSj