Webster Hardness Tester

Similar documents
Digital Webster Hardness CDW-20 SERIES

MN-ISHB-B300-E ISHB-B300 BARCOL HARDNESS TESTER OPERATION MANUAL

ISHR-M111 MAGNETIC ROCKWELL HARDNESS TESTER OPERATION MANUAL

ISH-R150 MANUAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

MN-ISHB-H131-E ISHB-H131 HYDRAULIC BRINELL HARDNESS TESTER OPERATION MANUAL

ISH-MRD200 AUTOMATIC DIGITAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

Greenslade & Company Rockwell Hardness Tester, Dial Type

INSTRUCTION MANUAL PCE-HT 550

INSTRUCTION MANUAL PCE-HT 500

Maintenance Information

The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.

Operating Manual Multi-Spot M22AL CD Stud Welding Machine

Tube Facing Tool.

Application Tooling Specification Sheet

Operation and Service Instructions With Replacement Parts List

Model SQM-2AC Squaring Module Rev TABLE OF CONTENTS

Application Tooling Specification Sheet

MODELS CSU 30 CSU 32AC CSU 32RL CSU 50AC CSU 50RL MDM 40 ELECTRIC MAGNETIC DRILLS OPERATING MANUAL

15 Industrial Tools. Recognized by Professionals. Work Together. Scribing Needle. Replacement of Scribing Needle. Features. Use A B

OxFAC-08 Angled Fiber Cleaver. User Manual. Issue 1.5

IIIIIC. Industrial Supply. USER MANUAl FOR ROCKWEll HARDNESS TESTER

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

OPERATING INSTRUCTION

Operating Manual Riveting Tool R1. For installing blind rivet nuts

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

Cold Saw Blade Basics

Single Jersey Plain. Single Lacoste. Needle set out. Cam arrangement F K. Needle set out. Cam arrangement F1 F2 F3 F4 K T K K K K K T

SERVICE MANUAL for Telescopic pole, Gripo Alu

FD50-H SLIDING DOOR SYSTEM Installation Manual (Ceiling Mount Type for Pocket Door, with Dual Soft Close) Part No.FD50DHCP-PD

VERSAtoolTM SAE J533 & SAE J1453. Safety and Operating Manual

HAND CRIMP TOOL SPECIFICATION SHEET Order No

Question 1. Flat file. Half -round. Round file. Three square ( triangle ) Needle files. Page 1 of 46

Application Tooling Specification Sheet

Pliers. Pliers PLIERS

HVS-1000DN. Digital Micro Vickers Hardness Tester. BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti.

Profiles for floors of same height Proclassic Proclassic F

EMO. Service Instruction. created by Frank Weithöner. Table of contents: Special Tools Assembling Mixing Chamber

VF6500 Hand-Held Portable Hardness Tester

Application Tooling Specification Sheet Order No

Technical Manual. ETP-CLASSIC incl type R. Content

Model 204B-EM Elbow Mandrels Rev TABLE OF CONTENTS

Elcometer Muller Laboratory Grinder

This instruction sheet covers the application and maintenance procedures for Crimping Die Assembly

PARAGON BATH SHOWER DOOR/ BATH TUB SCREEN INSTALLATION INSTRUCTIONS. DR-584b

Tube Facer For 3/8 1-1/2 Tube OD - ETF Style

OPERATING INSTRUCTIONS MODULGRAV. Tel. +49 (0) Fax +49 (0) homepage:

assembly instructions

HAND CRIMP TOOL SPECIFICATION SHEET Order No

AUG 15 Rev M

INSTALLATION INSTRUCTIONS for DALTON LED SERIES

LINEAR MEASUREMENT. Prof.H M Prajapati & Prof. A R Sankhla

Model CBM-3 Counterbore Module Rev TABLE OF CONTENTS

Flat file. Round file. Hand file. Half -round. Mill file. Square file

REP Design LLC. 193 Winding Ridge Rd, Southington, CT INSTALLATION INSTRUCTIONS:


Auto-Spreader Spreader HS10K Hydraulic Flange Spreader

MUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3

Rev B C-RING TOOL VA0375 ½ in. OPERATING MANUAL

Hand Crimp Tool Operating Instruction And Specifications Sheet Order No Eng. No. RHT 7050 (Replaces )

Instruction Guide. for All-American 8 TM. Turret Press Victory TM. Single Stage Press Ideal TM. C-Frame Press BrassSmith TM.

Manual 600MRD-L ROCKWELL HARDNESS TESTER

Hand Crimping Tool [ ]

Astro-Physics Inc. 400QMD Lubrication/Maintenance Guide

Technical description

WARNING! Read and understand the entire instruction manual before attempting set-up or operation of this machine!

Installation Instructions: OFC Gas Grip

Sprinkler wet pipe and dry pipe. For FM approval of the dry pipe model "I" shall be used. SBF 120: 7 applies to model "E".

CHEMINSTRUMENTS LABORATORY DRAWDOWN COATER LC-100 OPERATING INSTRUCTION

Comparative Measurement

Sales and Service

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

Ox-RAC-08 Ribbon Angled Fiber Cleaver User Manual

Horizontal and Vertical. Metal Cutting Band Saw MODEL: BS-115

HAMMER DRILL OWNER S MANUAL

MANUAL TNS Series Nut Splitter

A socket contact support (supplied separately) must be installed onto the locator assembly.

OWNER'S MANUAL Issue 2 - December 14, 2000

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

SCOPE Perma-Seal Terminals and Splices AWG (Rings, Spades, Hooks, 3 and 4-Ways, and Splices). RHT-5770 Hand Crimp Tool

TABLE OF CONTENTS MODEL 8750/8800 OCL

Operating Instructions

Hand Crimp Tool Operating Instruction Sheet And Specifications Part No Eng. No. RHT 1752 (Replaces )

Mini Max 20 BAND SAW

Pneumatic Drill / / Technical Specification

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A332

User s Manual. Portable Chamfering Machine

HARDINGE Installation booklet For: Dead-Length Collet Adaptation Chucks Stationary Collet

Handling instructions

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A335

Application Tooling Specification

limiting factor on the thread type used.

6625 WEST WILSHIRE BLVD. OKLAHOMA CITY, OK (405) FAX (405)

Elcometer Cross Hatch Cutter. Operating Instructions

HAND CRIMP TOOL Operating Instruction and Specification Sheet Order No (CR60622B)

HAND CRIMP TOOL Operating Instruction and Specification Sheet Order No (CR6115B)

PRODUCT MANUAL 12ST (V.3.0) 12ST FS (V.1.0.F) RON-WPM ST/12STFS-Rev.2

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

SPOTFAST FASTENERS BULLETIN

C-L-X ARMOR REMOVAL PROCEDURES

Transcription:

Webster Hardness Tester 1. Instrument Structure The structure of Webster hardness testers is shown as Fig. 1: 1-Frame 2-Pivot screw 3-Handle 4-Reset key 5-Adjusting screw 6-Dial head 7-Adjusting nut 8-Indenter cylinder 9-Load spring 10-Indenter 11-Anvil 12-Return spring Fig. 1 Structure of the Instrument The indenters of each type of Webster hardness testers are different. The shapes of three types of indenters are shown as Fig.2. Fig. 2 Indenter Shapes

2. Main Technical Parameters Festing Range: 0~20HW Accuracy: 0.5HW Eqnivaient range: See Table 1 Weight: 0.5kg Table 1: Models Selection Item Type Applicable Materials Hardness Range Specimen Size/mm 1 W-20 2 W-20a 3 W-20b 4 W-B75 5 W-B75b 6 W-BB75 7 W-BB75b Aluminum alloy Brass in hard or half hard state, super-hard aluminum alloy Soft brass, pure copper 25-110 HRE 58-131 HV 63-105 HRF 18-100 HRE Thickness 0.4-13 Thickness 0.4-8 Inner diameter>6 Thickness 0.4-8 Inner diameter>6 Thickness 0.4-8 Inner diameter>6 8 W-B92 Cold-rolled steel sheet, stainless steel 50-92 HRB 3. Operating Method Put the specimen between the anvil and the indenter and press down the handle until the bottom is felt. At the time the dial indicator will point at a reading which is the hardness value obtained. Excessive pressure beyond this limit will not damage the tester, but it is unnecessary. Hold tight the handle when reading the value. Any torsion or movement will make the reading incorrect during the test. 4. Verification and Calibration 4.1 Verification of the Instrument 4.1.1 Full Scale Verification Hold tight the handle directly to the bottom without putting the specimen in the opening of the hardnesstester. The indicator should point at 20±0.5HW. If the test reading does not meet the requirement, calibration of the full scale should be carried out according to Step 4.2.1. 4.1.2 Test Block Verification The standardized hardness block is tested by the hardness tester. For B, B-1 and B-2 Webster hardness testers, the dial indicator should point at the specified hardness values with tolerance of ±0.5HW; for B75, B75b and B92, the indicator should point at 5HW±0.5HW; and for BB75 and BB75b, the indicator should point at 17HW±0.5HW. If the test reading does not meet the requirement, calibration of the load spring should be made according to Step 4.2.2. Operators should regularly check the accuracy of the instrument by the standard hardness block. Calibration should be made if any deviation occurs.when testing the hardness block, use only its upper surface. 4.2 Calibration of the Instrument Calibration of this instrument includes calibration of the Full Scale and calibration of the load

spring. Calibrationof the Full Scale is actually to set a benchmark for the scale 20. Calibration of the load spring is actually to provide with a reference point for the instrument, and this reference point is the known hardness value of the standard hardness block. After calibrating, the full scale should be verified again and its reading should conform to 4.1.1. 4.2.1 Calibration of Full Scale Hold tight the handle directly to the bottom without putting the specimen in the opening of the hardness tester. As shown in Fig. 3, regulate the full-scale adjusting screw with a small screwdriver to bring the indicator at Scale 20. If the pointer pointing at a smaller value than 20, the adjusting screw should be regulated clockwise; if the indicated value is greater than 20, the adjusting screw should be regulated anticlockwise. If the pointer can not be set to the full scale 20 by regulating the adjusting screw, replace the indenter according to the steps in Section 5. Fig.3 Regulate the adjusting screw Fig.4 Regulate the adjusting nut 4.2.2 Calibration of the Load Spring Screw off the pivot screw, and take out the lower handle from the main frame, then remove the dial head from the indenter cylinder, while leaving the cylinder in the frame. Then the adjusting screw with grooves can be seen in the indenter cylinder. As shown in Fig. 4, rotate the adjusting screw with the special wrench equipped with the instrument. If the reading of the hardness block is smaller, rotate the adjusting nut anticlockwise; otherwise, rotate the adjusting nut clockwise. When the nut is rotated 1/4 circle, the scale reading will change 2-3 units. Reassemble the tester and verify the hardness block after regulating it. Repeat the above steps until the full scale and the reading of the hardness block are both according with the requirements in Section 4.1. DO NOT rotate the adjusting screw at will except normal calibration. DO NOT calibrate the readings of the testing standard hardness blocks by regulating the adjusting screw. 4.2.3 Calibration of the B-1 Webster Hardness Tester Put the calibrating sheath on the anvil first; then calibrate the instrument according to the calibrating procedure in 4.2. 5. Replace the Indenter In case the pointer can not be set to the full scale 20 by regulating the adjusting screw, which means the indenter is worn, the indenter should be changed. Shown below is how to replace the indenter: Screw off the pivot screw, and take out the lower handle from the main frame, then remove

the dial head from the indenter cylinder, but the cylinder still stays in the frame. Then the adjusting screw with grooves can be seen in the indenter cylinder. As shown in Fig. 4, rotate the adjusting screw with the calibration wrench equipped with the instrument, then take out the indenter and replace with a new one. Calibrate the instrument again according to the calibrating procedure in 4.2. After the indenter is replaced, adjust the pressure of the load spring with the adjusting nut, when the resistance of the load spring is sensed, only one tight rotating of the nut is enough. The indenter tip could be damaged by the over pressure of the load spring at first adjustment. 6. Verification Report The verification report should include the following information: Material brand and name Type and serial number of the hardness tester Reading of each test (accurate to 0.5 scale) Average hardness value (accurate to 0.5 scale) No. of standard applied Inspector and date 7. Standard Package 1 Tester 1 standard hardness block (attached with measurement and inspection report) 1 spare indenter 1 wrench 1 small screwdriver 1 instruction manual 1 carrying case 8. Optional Accessories spare indenter standard hardness block spare dial glass 9. Maintenance The testers of this series are precision instruments, of which the service life mainly depends on the correct method of use and timely and proper maintenance. The following items should be taken into account: 9.1 Prevent contamination. This instrument should often be cleaned with the soft cloth to remove the dust and dirt on the surface of it, especially on the anvil and supporting surface of the cylinder. Specially prevent the dirty things to get in from the dial seams or indenters, otherwise, the filthy things from those parts might influence on the testing precision or cause malfunction. 9.2 Prevent rust. Although all the parts of instrument have been treated to prevent rust, the improper maintenance or long time of use on the production spot without paying attention to maintenance may also cause the rust to some components. When using it, pay special attention to its waterproof performance except clean it frequently, because many parts will bear rust with water, the water in the dial may cause deadly rust to make the instrument useless. 9.3 Prevent falling off. This instrument is made up of many precision components, falling off of it will result in the permanent damage to some parts.

9.4 Disassembly forbidden. The testing accuracy of this instrument is guaranteed by the good collaboration of some of the precision parts. This collaboration is not easy for the nonprofessional people to master. Consequently, disassembly of the parts is not allowed except for those allowed in calibration, otherwise this will bring you trouble and the warranty of this instrument will terminate. 10. Factors Affecting the Test Accuracy 10.1 Test Piece. The surface of the specimen should be treated smooth and clean. The dirt on the specimen, especially the tiny sand grains may affect the test accuracy. 10.2 Sensitivity. The instrument scale below 4HW and above 17HW, its sensitivity will decline strikingly, and the testing accuracy will also be reduced. Applying another tester should be considered. 10.3 Edge of test piece. The distance between the testing point and the edge of the test piece should be bigger than 5mm. Test close to the edge of the test piece will affect the accuracy. 10.4 Adjacent indentations. During the test the distance between the two adjacent indentations should be no smaller than 6mm; otherwise, the previous indentation will affect the next testing accuracy. 10.5 Oxide film. Although the hard oxide film is thin, it will also influence on the hardness accuracy of the aluminum extrusions. Experiences indicate that the oxide film with hardness of 10μm will increase the hardness value by 0.5~1HW. 10.6 Coatings. All kinds of coatings will affect severely the testing accuracy, so sand paper or solvent is needed to remove the coatings first before carrying on the hardness testing. 10.7 Operation. Improper operation will affect the accuracy of the hardness. 10.7.1 The accuracy of this instrument should be often checked in use to see if the full scale point (20HW) and the calibration point are still correct. Calibrate it immediately when something is wrong. 10.7.2 The surface of the test piece should be vertical to the indenter and the bottom of specimen should contact the anvil during the test, otherwise errors will occur. 10.7.3 During the test enough grip strength should be applied at one time, adding the strength slowly will make the test result inclined to the low side. 10.7.4 During the test the test piece should not twist, otherwise it will make errors and damage the indenter.

Table 2 Hardness Conversion Table for W-20 Series Hardness Testers Webster HW Rockwell E HRE Rockwell F HRF Vickers HV 18 101 98.5 131 17 97 95 119 16 92.5 91 108 15 88 87.2 99 14 84 83 91 13 79.5 78 83 12 75 74 78 11 71 70 73 10 67 66 69 9 62.5 62.5 65 8 58 58 61 7 54 54 58 6 49.5 50 5 45 46.5 4 41 Table 3 Hardness Conversion Table for W-B75 series Hardness Testers HW HRB 4 53.0 5 53.3 6 54.1 7 54.8 8 56.7 9 58.5 10 60.8 11 63.4 12 66.4 13 69.7 14 73.5 15 77.9 16 82.1 17 86.9 18 92.2 Table 4 Hardness Conversion Table for W-Bb75 Series Hardness Testers HW HRF 4 30.2 5 34.9 6 39.6 7 44.3 8 49.0 9 53.7 10 58.4 11 63.1 12 67.8 13 72.5 14 77.3 15 82.0 16 86.7 17 91.4 18 96.1

Fig. 5 W-20 Series Hardness Conversion Curve Fig. 6 W-20 Series Hardness Conversion Curve Fig. 7 W-B75 Series Hardness Conversion Curve Fig. 8 W-BB75 Series Hardness Conversion Curve Fig. 9 W-B92 Series Hardness Conversion Curve