Practical PMU Applications for Utilities

Similar documents
Wide Area Visualization & SynchroPhasors

Synchrophasor Solutions Deployment at PG&E Off-Line Analysis

openpdc in the Control Center

SynchroPhasor Roadmap

GRID RELIABILITY MONITORING

Adamantios Marinakis, Scientist, 12 th IEEE SB Power Engineering Symposium, Leuven, Enhancing Power System Operation with WAMS

Alberta Electric System Operator (AESO) Oscillatory dynamics and corridor stress in the Alberta electric system

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Oscillatory Stability: Extended Range & Enhanced Source Location

In addition to wide-area monitoring systems, synchrophasors offer an impressive range of system benefits, including:

Phasor-based wide area monitoring in the South African power system

Prepared by Tony Weekes Husam Al Hadidi Brian Archer

Application of Synchrophasors in Power Plants Incorporated with Condition Monitoring Systems K P C L

Voltage Stability Assessment at the EMS

Phasor Measurements for Blackout Prevention

Wide Area Monitoring with Phasor Measurement Data

Synchrophasors and the Smarter Grid

Success Story: Practical Use of Synchrophasor Technology in ISO-NE Operations

ROSE - Real Time Analysis Tool for Enhanced Situational Awareness

Sarma (NDR) Nuthalapati, PhD

Task Force on Synchrophasor Protection Applications NASPI Engineering Analysis Task Team Matthew Rhodes 3/22/16

Recent Progress on Forced Oscillation Detection and Source Locating Findings at Peak Reliability. NASPI Work Group Meeting

UNIT II: WIDE AREA MONITORING SYSTEM

PHASOR TECHNOLOGY AND REAL-TIME DYNAMICS MONITORING SYSTEM (RTDMS) FREQUENTLY ASKED QUESTIONS (FAQS)

March 27, Power Systems. Jaime De La Ree ECE Department

Use of Synchrophasors to Detect Control System and Circuit Breaker Reclosing Issues

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

Synchrophasor Technology PMU Use Case Examples

Measurement tools at heart of Smart Grid need calibration to ensure reliability

A Software Tool for Real-Time Prediction of Potential Transient Instabilities using Synchrophasors

Experiences of Using Synchrophasors at Duke Energy

Chapter 25 PMU Deployment in Power System Oscillation Monitoring

Testing and Validation of Synchrophasor Devices and Applications

Low Frequency Local mode Oscillations in NER Grid, Validation using Model based analysis and Mitigation

Wide-Area Measurements to Improve System Models and System Operation

State Estimation Advancements Enabled by Synchrophasor Technology

Wide Area Control Systems (1.4) Mani V. Venkatasubramanian Washington State University (

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Use of the Power System Outlook (PSO) and SMART 1 Programs to View PSLF Dynamic Simulation Data Files

Testing and Implementation of a Source Locating method at ISO New England

Phasor Measurements in the WECC

Practical Experience with Modal Estimation Tools at Swissgrid

Deployment and Initial Experience with Oscillation Detection Application at Bonneville Power Administration

Dynamic stability of power systems

Synchrophasor Technology at BPA: from Wide-Area Monitoring to Wide-Area Control

Operationalizing Phasor Technology

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

ABB Inc. April 1, 2016 Slide 1

Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

Tor Rolv Time, Øystein Kirkeluten STATNETT Oslo, Norway

Operationalizing Phasor Technology. Model Validation. Webinar. Ken Martin. March 4, Presented by. Page 0

Monitoring and Situational Awareness Conference. Improving EMS Reliability Denver, CO September 18, 2013

New Standards for Test and Calibration of Phasor Measurement Units

ELEMENTS OF FACTS CONTROLLERS

Synchronous Measurement, Control, & Protection of Electric Power Systems. Dr. Edmund O. Schweitzer, III February 29, 2012

SDG&E Transmission Synchrophasor Project Update

Power System Wide Area Measurement, Protection & Control

Test Cases Library and Real-life Oscillation Examples

Using Synchrophasor System Data for Establishing Operating Range for Operators Guidance and Detection and Analysis of Significant Events

Events Captured and Findings To Date. John Ballance and Abhijeet Agarwal EPG John Adams and Jian Chen ERCOT

Smart Transmission Grids Operation and Control

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

Synchrophasors: Definition, Measurement, and Application

PMU-based protection for grid operation applications Wide Area Monitoring platform and controlled islanding

Uses of Synchrophasor BD NSF Workshop 2017

Synchrophasors for Distribution Applications

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Using Synchrophasors for Frequency Response Analysis in the Western Interconnection. Bonneville Power Administration -- WECC JSIS Chair

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

PMU-based Voltage Instability Detection through Linear Regression

Controlled Islanding Followed by Load Shedding Based on Rate of Frequency Decline

Generator Parameter Validation (GPV)

Operational Modeling and Model Inputs

Overview of Synchrophasor Applications. Dmitry Kosterev Bonneville Power Administration

The Effect of Delays on Wide-Area Damping Control of Electromechanical Oscillations

Algorithms to Improve Performance of Wide Area Measurement Systems of Electric Power Systems

PHASOR MEASUREMENT UNIT: - A Revolution in Power System

Use of Synchronized Phasor Measurements for Model Validation in ERCOT

Application Example Document ID: SA Rev. - September 24, 2004

Postprint. This is the accepted version of a paper presented at IEEE PES General Meeting 2016, Boston.

ABB Automation World 2012, V. Knazkins, 6 June 2012 Countermeasure of PSS4B for Low Frequency Oscillations PSS4B. ABB Group June 4, 2012 Slide 1

Published in A R DIGITECH

NYISO Situational Awareness Dashboard

Mining Phasor Data To Find The Hidden Gems In Your Archive

Synchrophasor Applications in the Croatian Power System

ANALYTICAL AND SIMULATION RESULTS

Oscillation Monitoring of Large-Scale Power Systems

Wide-Area Monitoring and Control of Power Systems using Real-Time Hardware-in-the-Loop Simulations

1400 MW New Zealand HVDC Upgrade: Introducing Power Modulation Controls and Round Power Mode

Wide-Area Small-Signal Stability Controller

Wide Area Monitoring Network Stability & Synchrophasors. GE Consumer & Industrial Multilin

Post-Event Analysis of a Compound Event in the ERCOT System Using Synchrophasor Data

APPLICATION OF PMUS FOR MONITORING A 50 KV DISTRIBUTION GRID

System Protection Schemes in Power Network based on New Principles

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

Integrating Synchrophasor Technology into Power System Protection Applications

Oscillation Monitoring System - Damping Monitor -

Monitoring Voltage Stability using Real Time Dynamics Monitoring System

F6052 Universal Time Synchronizer

Transcription:

Practical PMU Applications for Utilities University of Washington EE Graduate Seminar November 1 st, 2012 Manu Parashar Douglas Wilson

SynchroPhasor Technology Phasor Measurement Units (PMUs) Next generation measurement technology. (voltages, currents, frequency, frequency rate-of-change, etc) Higher resolution scans (e.g. 30 samples/second). Improved visibility into dynamic grid conditions. Early warning detection alerts. Precise GPS time stamping. Wide-area Situational Awareness. Faster Post-Event Analysis. SCADA Seconds Resolution PMU Sub-second Resolution

PMU Deployment within North America Currently 200+ PMUs Installed. Expected to exceed 800+ PMUs by 2013 (under SGIG Investments) Source: NASPI Website (www.naspi.org)

SynchroPhasors & Energy Management Systems Traditional MODEL-BASED Analysis (EMS) PMU MEASUREMENT-BASED Analysis (PhasorPoint) SCADA & Alarms WAMS Other EMS Applications State Estimator State Measurement New Applications Small Signal Stability Oscillation Monitoring Transient & Voltage Stability Stability Monitoring & Control Island Management Island Detection, Resync,& Blackstart Control Center -PDC

Look Ahead and Predictive Operations Capability in Control Rooms Reduces the impact of variability and uncertainty on real-time decision making in the control room

SynchroPhasor Benefits RELIABILITY CONSTRAINT RELIEF SUSTAINABILITY Situational Awareness Identifying sources of oscillations Vulnerability detection Automated wide area protection Identifying equivalent dynamic models Analysis tools e.g. Post Mortem Dynamic model validation Baselining Stability (damping) constraints Angle constraints WAMS + DSA (integration of measurement-based and model-based security assessment). Angle based control Renewable connections Impact of renewables on stability Distribution management

Operational Benefits Improved Reliability August 10, 1996 Blackout Monitor wide-area grid stress. August 14, 2003 Blackout ~ 3% (LOW) Damping (after Keeler Allston line trips) Dynamic Instability (Negative Damping) Early detection of dynamic instability.

Asset Management Congestion Relief AREA 2 Transmission Corridor Net Transfer Capacity AREA 1 Great Britain Scotland England Interconnector Australia Queensland NSW Interconnector Model limit with margin Limit with measured damping Thermal limit +300MW +300MW

Planning Benefits Dynamic Model Validation Western Interconnection August 10 th, 1996 Blackout Dynamic models predicted stable system when the system was in fact unstable. PMU provide necessary dynamic data to calibrate dynamic power system models.

Protection & Control Timely control actions necessary for them to be effective!

PMU Basics: What is a PMU? ANALOG Electrical Signal A/D DIGITISED SAMPLE PROTECTION and MEASUREMENT PROCESSORS FIBRE OPTIC 1 pps IRIG-B un-modulated P594 GPS RECEIVER Areva P847 PMU ETHERNET PROCESSOR Microprocessors IEEE C37.118 DATA Data frame over Serial or Ethernet (TCP/UDP)

Fundamental WAMS Components Phasor Measurement Unit (PMU) (MiCOM P847 Series) Analog Channels Va, Vb,Vc,V1, V2,V0 I1, I2, I0, Ia, Ib,Ic Frequency & Rate of Change of Frequency Digital Channels Any 8 status signals available Phasor Data Concentrator (PDC) (PhasorPoint PDC, OpenPDC) Time align measurements received from multiple PMU/PDC streams. Perform data validation. Provide time-aligned data at desired periodicity and formats to downstream applications.

Typical WAMS Architecture Source: NASPI Website (www.naspi.org)

Oscillatory Stability Management Simultaneous multi-oscillation detection and characterisation direct from measurements Measured P / f / Operations Early warning of poor damping (two level alarms) Unlimited oscillation frequency sub-bands Individual alarm profiles for each sub-band For each oscillation detected, alarm on: mode damping and/or mode amplitude for Mode Frequency 1/F MODE FREQUENCY Mode MODE DECAY decay TIME time EXP(-t/ Exp(-t/ ) MODE Mode AMPLITUDE Amplitude IMPROVED RELIABILITY: OSCILLATORY STABILITY Alarms MANAGEMENT Analysis Fast Modal Analysis: Trend Modal Analysis: A Mode Phase MODE PHASE Wide area mode alarms Planning & Analysis, Plant Performance Post-event analysis Dynamic performance baselining Dynamic model validation Mode locus plot with alarm thresholds Does not use system model In operational use since 1995 Damping controller performance assessment

Oscillatory Modes Observed in Colombia (2009) Ecuador Mode 0.49Hz Inter-area mode at 0.49Hz (Colombia- Ecuador). Opposing phase in South Governor Mode 0.06Hz Governor common-mode: whole system oscillates in coherent phase

Islanding, Resynchronization and Blackstart Colour: Frequency Identify islanding quickly Vectors: Voltage Phasors System split Alarm raised Islands clearly visualized Reduce time to resynchronize Improve system visibility in blackstart Ice slide destroys 2 transmission towers, IRB used to monitor system to maintain synchronisation for 2 weeks

Mode Amplitude (MW) PSS Tuning & Generator Commissioning Iceland (2006) 1.2Hz Mode Before PSS tuning After PSS tuning PhasorPoint Oscillatory Stability Management: Wide area real-time damping visualization and alarms Dynamics baselining & trending Wide area event analysis Mode Decay Time Constant (sec)

Renewables Integration Scotland (2012) In distribution network, increase connection capacity by constraining by angle Marginal reduction of capacity factor More capacity More energy

Wide Area Protection Scheme Iceland (2012) Loss of Large Smelter in SW Frequency rises more slowly Frequency rises rapidly Trip Gen proportionally in correct zone Angle difference increase E FREQ SW FREQ Smelter load Nearby generators change speed/angle quickly 132kV ring power Main generation area

www.alstom.com