CertainTeed Ceilings

Similar documents
ECOPHON Focus Ds 4x4 Installation Manual

METALWORKS TARTAN PANELS General Installation Instructions

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

Tips for Professional Ceiling Installers

Panel Grille Suspended Ceiling Installation Guide

CEILING SYSTEMS. MADERA VECTOR Semi-concealed system on exposed 24mm grid. Technical Data Sheet. [Between us, ideas become reality.

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

ROCKFON System Olympia Plus

METALWORKS Concealed. Installation Instructions

How to Install the QuickHang Installation Kit

Tools needed. Supplies Needed

Olympia Plus Sports Ceiling Impact Class 1A

INTERIOR INSTALLATION

CI/SfB. October RockLink Integra. Installation system

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

METALWORKS Linear (Interior & Exterior Applications)

METALWORKS Linear (Interior & Exterior Applications)

METALWORKS Linear (Interior & Exterior Applications)

metalworks Vector Assembly and Installation Instructions

WoodWORKS Channeled Plank

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

AXIOM Classic Trim. Assembly and Installation Instructions

Linear Wood Grille Ceiling Systems

WOODWORKS Access Hook-on System

AXIOM Classic Trim Installation Instructions

for Rigid Sun Lite Planning the layout

INSTALLATION MANUAL. Decoration panel BYCQ140E2W1 BYCQ140E2W1W BYCQ140E2W1B

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

Trim (Aluminum Substrate)

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Fitted Furniture Installation and Aftercare Guide

Commercial Systems

4300 Install Guide. Attention. Ceiling Accessories

Hospital Grade Welded Ceiling System

Side and rear window, assembly overview

Installation Instructions for. Before You Begin TOOLS REQUIRED

MESO X1 TBAR SEMI-RECESSED

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Top Mount Ultra Modern Hanger

WOODWORKS Concealed. Assembly and Installation Instructions

5X Racing Miata Radio Delete Plate Installation Instructions

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Kinro Metal, Vinyl, Flush Mount and Recessed Fin Windows OEM INSTALLATION MANUAL

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

Contour Hanger ASSEMBLY INSTRUCTIONS

Hawko LED Flex & Accessories Installation Instructions

INSTALLATION INSTRUCTIONS

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

Lightplane 3.5 Recessed

ATLANTIS RAIL Contact Information

Manually adjustable blades Return air VAV cooling only VAV cooling and warm up heating TF-D TF-RA TB-C TB-CW

Vanity Installation Instructions

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Curtain Wall Installation Guide

North East Toilet Cubicles Ltd.

ClearSpan Mini Grab Bag Shelters

SAGIREV Installation Manual

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

Installation manual: Tähtisaunat Moderni/Elegance/Original Straight Benches

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

Basic Installation HOFFMANN KEY HOFFMANN KEY. Page Revised: DEC. 2017

ClearSpan Mini Grab Bag Shelters

ARMSTRONG METALWORKS BAFFLES Installation Guide

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

TECHZONE Ceiling Systems Selection Guide

Installation Manual MODEL ANE-42

Sky FactoryTM toll free

Stag Hanger ASSEMBLY INSTRUCTIONS

SINGLE TRACK BYPASS (patent pending) barn door hardware

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

INSTALLATION INSTRUCTIONS

Pivot Frame Mounting Instructions

Installation Instructions

ELiTE ProPanel Installation Guide

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System

ClearSpan PolyMax Windbreak Wall

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

How to repair a wall or ceiling FREE

DeckRail A Product of DeckRite LLC 3912 East Progress North Little Rock, AR Phone: (501) Fax: (501)

Kinro Metal, Vinyl, Flush mounted and Recessed Fin Windows (HUD) OEM INSTALLATION MANUAL

Sonoran Sheer Vertical Shadings

Rockfon System OlympiaPlus A Impact 1A

INDIVIDUAL MOUNTING: T-Bar

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

INSTALLATION INSTRUCTIONS

Assembly and Installation Guide

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Acoustical Infill Panels

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

L182 - Installation Sheet Modular Wine Rack ( Wall Mount )

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

Table of Contents. Linings/Sheathing/Dry partitioning. Rigid sheet fine linings and panelling / Rev

QWALL 5.2 (2 Back Panels)

9x9 Penthouse Garden Shed Assembly Manual

HR175 Sash Replacement Kit Installation Instructions

WOODWORKS Walls. Installation Instructions WALL

Transcription:

CertainTeed Ceilings 7 Ecophon Focus Dg 2x2, 2x4, 2x5, 2x6, 2x8 Installation Instructions 5 2 3 6 4 1 Components: 1. Ecophon Focus Dg Panel (2 x2-8 ) 2. CertainTeed 15/16 Classic Main Runners 3. Certainteed 15/16 Classic Cross Tees 4. CertainTeed Ceilings 15/16 Wall ngle Page 1 of 16

5. Connect DG20 Support Clip 0547 6. **Optional** Connect Wall Bracket T-profile 0524 (ll required screws by others) 7. 12 Gauge Hanger Wire 8. 2 Stabilizer Bar (For 2 x6 and 2 x8 ) (Must be compatible with main runner) dditional Components: 9. Connect DG Cutting Tool 0991 10. Connect Edge Sealant 0691 Wear clean white cotton gloves when handling Focus Dg panels. Page 2 of 16

Pre-Installation: Please read CertainTeed Ceiling s Pre-Installation Instructions before you begin these installation instructions. Note that the finished surface of Focus Dg Panels is 1/2 below the grid. Focus Dg is an extremely precise system and the tolerance is low. The grid system must be square and level. 1. Installing Wall ngle a. To install Wall ngle choose a height at least 3 below joists, existing ceilings, ducts, pipes, or wiring, to ensure clearance and maneuverability required to install the panels (integration with diffusers and light fixtures may dictate a greater depth of system). b. Mark the desired height for the finished surface of the ceiling on all four walls (see Steps 2-3). c. ttach Wall ngle using appropriate fasteners. Perimeter Detail 1 Semi- Concealed Wall ngle 2 Page 3 of 16

Perimeter Detail 2 Semi-Concealed Wall ngle 15/16 Main Runner Wall Focus Dg Panel 15/16 Wall ngle 3/8, (dimension can be changed at the rchitect s discretion) Page 4 of 16

3. Install Hangers a. Mark lines for each of the main runners (4 on center for 2x2 & 2 x4 panels, 2 on center for 2x5, 2 x6, & 2 x8 ). b. Pull a string line along the path that the first main runner will take. ttach the line directly below the wall molding. c. Hangers should be placed every 48 along the main runners, at a max of 24 from the walls. 3 ~3/8 Note: The Connect Wall Bracket T-profiles are optional. If T-Profiles are not used, the cross tee can be cut tight into the wall (the 3/8 gap is not needed). ~3/8 Page 5 of 16

4. Install the main runners a. Install the first section of main runner, with cut edge sitting on the wall molding. b. ttach the main runner to wire. c. Repeat for the next sections of main runner. ~3/8 4 ~3/8 Page 6 of 16

5. Install Cross Tees and Border Tees a. Cut in border cross tees. Use a string line to make sure the main runners are straight. b. Install cross tees as needed. 5 48 ~3/8 ~3/8 Page 7 of 16

6. Install remaining cross tees a. Install remaining cross tees. b. For 2 x6 or 2 x8 Ecophon Focus Dg panels, install 2 Stabilizer Bars at the mid-point of each module opening to assist in stabilizing the over-sized module. c. Check to see if the suspension system is square. Make adjustments as needed. 6 24 Page 8 of 16

7. Install Field Panels (Note: 2 x6 and 2 x8 panels require two people to install each panel). Before you begin installing the panels, you must understand that Focus Dg panels have 2 supporting edges and 2 non-supporting edges. s illustrated below: Supporting Edges Non-Supporting Edges Please note that the long sides of the panels are always the supporting sides. a. Wear white cotton gloves, so that the dirt and oil from your hands, does not get on the panels. (If gloves become soiled, replace them immediately). b. Start installing panels in the middle of the field. c. To install Focus Dg Panels, Follow Step 8 1 & 8 2. Page 9 of 16

24 8 1 Step 1: Place the leading edge () into the grid as shown, making sure that the edge is pushed as far as it can go into the flange. 24 8 2 Step 2: Slide panel toward trailing edge (). Leading edge () will move into its finished resting place. To remove the panel, lift up gently on either edge () and perform the process in reverse. 5/16 5/16 Page 10 of 16

9. Install Border Panels To understand installing border panels/edge treatment, consult the appropriate directions below. Step 9 Focus Ds 2x2 Step 10 Focus Ds 2x4-8 Page 11 of 16

- 1 Cutting Tool 0991 2 3 X X - 1/16 X - 1/16 3/8 9 1 B B B B 1 2 3 X X - 1/16 X - 1/16 3/8 B-B Notes: a. The Focus Dg System is designed so that 3/8 of the wall molding is visible from below. The dimension of molding exposed is at the rchitect s discretion. If the rchitect does not specify the distance, these directions will result in a 3/8 gap around the border. b. For more accurate cut edges, measure at least twice at each end of the panel, so the cut edge follows the contour of the wall. c. Straight cuts should be made using a razor knife and a straight edge. d. The Connect DG Cutting Tool 0991 cuts a 9/16 by 9/16 rabbet. The shim attached to the tool should remain for cuts in 3/4 panels. e. Connect DG20 Support Clip 0547 should be spaced every 12-18. f. Connect Edge Sealant 0691 is used as required. void applying edge sealant to the surface of the panel. Page 12 of 16

Z-Z W-W X Y X- 1/16 Y- 1/16 9 2 Z X - 1/16 1 W W Z 2 3 Y- 1/16 Page 13 of 16

D-D Cutting Tool 0991 1 2 3 4 X X - 1/16 X - 1/16 3/8 10 1 4 D D F F 3/8 1 2 3 X F-F X - 1/16 X - 1/16 Notes: a. The Focus Dg System is designed so that 3/8 of the wall molding is visible from below. The dimension of molding exposed is at the rchitect s discretion. If the rchitect does not specify the distance, these directions will result in a 3/8 gap around the border. b. For more accurate cut edges, measure at least twice at each end of the panel, so the cut edge follows the contour of the wall. c. Straight cuts should be made using a razor knife and a straight edge. d. The Connect DG Cutting Tool 0991 cuts a 9/16 by 9/16 rabbet. The shim attached to the tool should remain for cuts in 3/4 panels. e. Connect DG20 Support Clip 0547 should be spaced every 12-18. f. Connect Edge Sealant 0691 is used as required. void applying edge sealant to the surface of the panel. Page 14 of 16

G-G 2 1 3 Y Y - 1/16 Y - 1/16 3/8 10 2 3 G G G G Page 15 of 16

H-H 1 J-J X Y X - 1/16 X - 1/16 Y - 1/16 Y- 1/16 10 3 2 H J J H 3 Page 16 of 16