Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E

Similar documents
High Speed Air Turbine Handpiece

TABLE OF CONTENTS TABLE OF CONTENTS...1 INTRODUCTION...2 TECHNICAL DATA...3 POLISHER INSTALLATION...4 SAFETY AND OPERATIONAL INFORMATION...

Restoration & Prosthetics

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

MIL-STD B (SH) UPDATE

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DS4012 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Clarinet/Bass Clarinet Care

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

Cleaning the cutter blade

Tube Facing Tool.

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

LX1 Maintenance Manual for Model LX1B. Table of Contents 1. GENERAL DISASSEMBLY, ASSEMBLY AND ADJUSTMENT COMPONENTS...

INSTRUCTION MANUAL. 200 Main Street Elmwood WI Phone: Toll Free: Fax:

D25122(K) D25123(K) D25124(K) D25213(K)

HAMMERDRILL ATTACHMENT

Multi Function Ultrasonic Scaler

ROTARY HAMMER OWNER S MANUAL

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Scaler Handpieces

Application Tooling Specification Sheet

solid titanium handpieces


2.0. Contents Function control

Maintenance Information

RING CUTTING SYSTEM OPERATION MANUAL. The lighter your touch, the faster GEM cuts

CLEANING FOR BETTER OBSERVATION AND PHOTOMICROGRAPHY

SALES CUSTOMER SERVICE TECHNICAL ASSISTANCE CALL TOLL-FREE:

SCALE AIRE MINI INSTRUCTION MANUAL. Engler High Speed Dental Air Unit

5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used


CLEANING THE GALVO MIRRORS

Instruction Manual for Recipro Handpiece Model: Z-6X #

Stem & Adapter Options. The WoodScents kit includes multiple stem and adapter options:

OPERATION MANUAL. Multi Function Ultrasonic Scaler. Varios 570. Please read this Operation Manual carefully before use, and file for future reference.

SUPER PRO GUN & SUPER PRO GUN II

GENERAL OPERATIONAL PRECAUTIONS

Rotary Hammer DH 40MR

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

Installation Instructions 8115F 8115SF

OPERATOR S MANUAL OSADA EXL-M40 OSADA EXL OSI-2 OSADA, INC.

FREUD. Operating Instructions. JS104K Biscuit Joiner Kit

MAINTENANCE MAINTENANCE

KaVo POWERtorque LUX 646B PB (Pushbutton) Repair Procedure

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

General Help. Last revised: Winter When I try to print something on the computer, it appears to work, but nothing comes out of the printer.

RTI TECHNOLOGIES, INC.

DIY KIT DIY KIT. User Manual CTK

ROTARY HAMMER OWNER'S MANUAL

Rotary Hammer HR3200C HR3210C HR3210FCT INSTRUCTION MANUAL

SAFETY AND OPERATING MANUAL

ET-110 EXTREMA MACHINERY COMPANY, INC. P.O. BOX 1450, ALBANY, LOUISIANA (877) FAX (225)

Crimping Dies; PN thru 47825, 47915, and 47918

Auto Feed Screwdriver

Automatic Screwdriver Model W 4YD. Handling instructions

RB30. LittleBrute MAGNETIC DRILL PRESS SAFETY GUIDELINES PARTS & SCHEMATICS USER GUIDELINES

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

Premium Soldering station

Maintenance Manual for Auto Lab

Tidland Narrow Web Shaft

Handling instructions

SECTION 7. SAFETYING

PS /8 Inch Electric Drill Assembly & Operating Instructions

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.

SAFETY AND REPROCESSING INSTRUCTIONS - CONSIGNES DE SÉCURITÉ ET DE TRAITEMENT - INSTRUCCIONES DE SEGURIDAD Y TRATAMIENTO APPLICATIONS

COJSAWBX Electric Jig Saw Assembly & Operating Instructions

Application Tooling Specification Sheet

C-1116LMA - Automatic Stapler w/ Long Mag

Self-Feeder Soldering Station DSF76D-IW. Operation Manual

GENERAL OPERATIONAL PRECAUTIONS

HBS-AP ASSEMBLING INSTRUCTIONS

Angle Grinder MODEL 9553B MODEL 9555B


Application Tooling Specification Sheet

ELECTRIC TOOL CORPORATION

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

GENUINE PARTS INSTALLATION INSTRUCTIONS

Maintenance Information

Powermatic Model 31A Combination Belt-Disk Sander

Electric Router. Please read and fully understand the instructions in this manual before operation and keep this manual safe for future

Magnetic Base Drilling Machine A100/32. Operators Instruction Manual And Spare Parts Listings

Handling instructions

HAMMER DRILL OWNER S MANUAL

Swift assembly guide

Operating manual. TruTool N 500 (1A1) english

18600 PORTABLE POWER DRIVE THREADER PRODUCT INFORMATION AND OPERATING INSTRUCTIONS:

18500 PORTABLE ELECTRIC POWER DRIVE

ARROW SAW PRECISE CUT 8000 RPM WITH DUST COLLECTING ATTACHMENT INSTRUCTION BOOK MODEL NO

STRAIGHT SHAFT TRIMMER ATTACHMENT 29402

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

User Manual. LED Dental Scaler, Drill and Polishing unit Eicksonic Plus

GRUL400 Cordless Ultra-Lok Tool

WARNING: Wear safety goggles at all times when the engine is running and cooling

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved

SAFETY INSTRUCTIONS. Wear protective clothing, including safety glasses and steel toe boots.

BB Inch Double Cut Saw Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

POTENTIAL HEALTH & SAFETY HAZARDS

Model: SCD430 SCD640. Installation & Operation Guide P/N SCD640-95

Transcription:

Surgical Handpiece Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93 S-Max SG20 09.03.01 M OM-C0425E 001

for X-SG20L,SG20 This handpiece is used only for the Surgical Unit with Torque Calibration System such as NSK Surgic XT Plus. Using this product with other surgical units may break the handpiece or bone. ENGLISH Intended to Use The handpiece is designed only for surgical use by qualified personnel. Only X-SG20L/SG20 can use drill When operating the handpiece always consider the safety of the patient. 1

2 Check for vibration, noise and overheating outside the patient's oral cavity before use. If any abnormalities are found, stop using the handpiece immediately and contact your authorized dealer. Galling of bearing and gear or entering abnormal materials into head may cause a burn injury. Do not allow any impact on to the handpiece. Do not drop the handpiece. Do not attempt to disassemble the handpiece or tamper with the mechanism. Make sure you have an additional handpiece ready in case of unexpected malfunction during operation. Sterilization in an autoclave is recommended before initial use and thereafter prior to every use. Do not connector disconnect the bur/drill or handpiece until the motor or has completely stopped. Do not use recommended burif you use that bur/drill, it may bent or fly away during rotation and do not exceed the drive motor speed recommended the bur manufacturers. Do not use bent, damaged or sub-standard burs/drills. And do not exceed the drive motor speed recommended the bur/drill manufacturers. This may cause shank bend or brake even within the recommended speed. Always keep the bur/drill shank clean. Debris in the chuck mechanism can prevent burs from seating properly and cause them to fly out during use. Do not operate the handpiece without the bur/drill. Do not push the push-bottom during operation. If it pressed, it may -OVERHEATING of the handpiece head. Special caution must be exercised during use to keep cheek tissue AWAY from the push-button of the handpiece. Contact with cheek tissue may cause the push-button to depress and injury to the patient may occur. -Result of malfunction. Always operate with water spray. Failure to do so may result in overheating. During cut the teeth, wear eye protection and dust protective mask for your health. Do not use excess pressure on the treatment area. After each use, be sure to clean, lubricate and sterilize the handpiece. If blood is left on the handpiece, it can clot causing rust. Neglect lubrication may cause OVERHEATING. Do not wipe nor immerse the handpiece or tips in acidic water or acidic solutions. Perform periodical maintenance checks. If the handpiece has not been used for a long period, check for noise, vibration, and overheating before use. 3

4 for X-SG93L/X-SG93 Do not use the motor which runs at up to 400,000min -1. Do not use long surgical burs. Do not use burs longer than 26mm. The shanks of longer burs may warp under. Always use irrigation water during the operation. Head may overheat because of the high speed rotation. Even if it do Irrigation and use handpiece, bearing is worn and it may overheat or noise. Ask repair for your dealer. 1. Connecting / Disconnecting the Handpiece (1) Connecting Push the handpiece on to the motor taking care to keep it in alignment. Twist the handpiece until it locks into position with a clicking sound. (X-SG20L/SG20, X-SG25L, X-SG93L/X-SG93) (2) Disconnecting To disconnect, hold the motor and the handpiece, and pull out it straight. Handpiece Motor Insert Do not connect or disconnect handpiece until the drive motor has completely stopped. Connect only the motor which has max rotation speed is less than 40,000min-1 with E type joint (ISO3964) Connect only NSK s Motor or motor that it have stopper pin. This product s joint followed ISO3964 standards. Motor Fig. 1 5

2. Mounting and Removing Bur / Drill Only X-SG20L/SG20 can use drill (1) Mounting X-SG20L/X-SG20,X-SG25L 1) Insert the bur/drill into the head. 2) Lightly turn the bur/drill until it engages with the latch mechanism. (Fig. 2) 3) Push bur/drill inward to click then it locks. (Fig. 3) Fig. 2 X-SG93L/X-SG93 1) Align bur and guide area of the handpiece. 2) Depress push button to open chuck. Insert the bur into the chuck. 3) Gently turn the bur until it engages with the mechanism. (Fig. 4) 4) Push bur inwards to click into place. After the bur/drill is locked in place, lightly pull out the bur/drill to make sure the bur/drill is locked. (Fig. 4) If the bur/drill does not install firmly. It may fly away or it does not remove. 2 1 Fig. 4 6 Fig. 3 7

8 (2) Removing Push the push button with a thumb, and the bur/drill is removed. (Fig. 5) Depress the head cap button until it is almost parallel to the head cap. If removing the bur becomes difficult, depress the Push-button, grip the bur with fine pliers and gently remove the bur. This case may be prevented if you often change the position of the bur in the chuck. Fig. 5 3. Spray Nozzle X-SG20L/SG20 has 3 irrigation methods are available; External, Internal or both of them, depending on tool and operation procedure. For X-SG25L, X-SG93L/X-SG93, it can connect the Irrigation Tube to the External Spray Nozzle firmly. (1) External Spray Nozzle Connect the Irrigation Tube to the External Spray Nozzle firmly. (Fig.6) (2) Internal Spray Nozzle (Fig.7) Only a drill with internal irrigation is used. 1) Set the nozzle holder. 2) Insert Irrigation Tube in Internal Spray nozzle. 3) Put the Internal Spray Nozzle into the head firmly. 4) Put the Internal Spray Nozzle into the slot on the Nozzle Holder. Internal Spray Nozzle: 10000324 Nozzle Holder: X-SG20L: 20000396 / SG20:20000357 External Spray Nozzle Internal Spray Nozzle Irrigation Tube Fig. 6 Irrigation Tube Nozzle Holder Fig. 7 9

10 (3) External and Internal Irrigation together Only a drill with internal irrigation is used. 1) Connect the ends of the Y-Connector to the External Spray Nozzle and Internal Spray Nozzles refer as detailed in procedures (1) and (2). 2) Connect the Irrigation Tube to the Y-Connector firmly.(fig.8) Y-Connector: Order No. 20000503 4. Maintenance (1) Cleansing Handpiece X-SG20L/X-SG20 1) Remove bur/drill form the handpiece. 2) Remove any debris in and around the outlet holes with the brush. 3) Half fill a cup with clean water. Operate the handpiece about 15seconds. And immerse 20mm of the handpiece head in the water 4) Lubricate before autoclaving.((2)refer Lubrication) Y-Connector Irrigation Tube Fig. 8 Fig. 9 When handpiece clean dirt of external surface, be careful the water does not enter into inside of rear of the handpiece. X-SG25L, X-SG93L/X-SG93 1) Remove any debris in and around the outlet holes under the running water. 2) Lubricate before autoclaving(refer ((2)Lubrication) Use only clean water to maintain the Clean Head System and change water each patient. When debris has been removed, ensure the water does not enter the indie of the handpiece by handpiece rear side. It may cause a malfunction. 11

12 Spray Nozzle Cleaning 1) Clean Internal Spray Nozzle and External Spray Nozzle (internal and external) by using Cleaning Wire.(Fig. 10,11) 2) Insert a Irrigation tube in each Spray Nozzle, and wash it away with clean water.(refer to 3. (1)(2)) Cleaning Wire: 20000512 Cleaning wire Internal Spray Nozzle External Spray Nozzle Fig. 10 Fig. 11 (2) Lubrication 1) Use PANA SPRAY Plus with an E-type spray nozzle. 2) Always lubricate handpiece WITHOUT bur. 3) Shake can well to mix lubricant and propellant. 4) Insert the spray nozzle into the handpiece. Place a tissue over the head end of the handpiece, hold firmly and spray for 2-3 seconds. Check the tissue, if it is clean the handpiece can be autoclaved, if not spray again until clean. For optimum lubrication use NSK Care 3 Plus. E Type Spray Nozzle:Product number 109-09 Handpiece E-Type Spray Nozzle Hold handpiece firmly as you are lubricating under pressure. Repeat lubrication until handpiece is clean and free of debris. If blood is left on the handpiece, it can clot causing rust. This may cause failures those are shortage of rotation or torque. Always hold the PANA SPRAY Plus can upright. When lubricate except PANA SPRAY plus, it may cause OVERHEATING. PANA SPRAY plus Fig. 12 13

(3) Stabilization Autoclave sterilization is recommended. Sterilization is required first time you use and after each patient as noted below. This handpiece can be cleaned and disinfected with a Thermo-Disinfector. This handpiece can be autoclavable up to Max.135 C. 1) The dirt of the handpiece surface is discarded with a brush (metal is improper).clean handpiece using water or Isopropyl alcohol. 2) Lubricate the handpiece. (Refer to (2) Lubrication) 3) Insert into an autoclave pouch. Seal the pouch (Only if using a vacuum autoclave) 4) Autoclavable up to max.135 ex.) Autoclave for 20 min. at 121 C, or 15 min. at 132 C. 5) Keep the handpiece in the autoclave pouch to keep clean before use. Do not wash, soak, or wipe off the handpiece with/in the oxidation potential solution (strong acid, super acid solution) or sterilized solution. Do not Autoclave the equipment which with residual chemical. It may cause a peel off the plating or exert a harmful influence to internal parts. Store it in a place where the handpiece is not subject to air with dust, sulfur or salinity. Do not touch the handpiece just after the autoclave. It is extremely hot. 14 15

5. Cleaning the Glass Rod Optic(X-SG20L, X-SG25L, X-SG93) Clean the Glass Rod Optic with cotton swab soaked in alcohol. (Fig.12) Do not use a pointed tool or sharp edged to clean the Glass Rod Optic. They may damage the mirror finish and reduce the light transmission efficiency. If Glass Rod Optic end has become damaged, return it to dealer for repair. 6. Repair Service For genuine NSK service and parts always return the handpiece to your NSK dealer. Cotton Swab Glass Rod Optic Fig. 12 16 18