Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R

Similar documents
Industrial, 2-Pole ZS Type RA2A

Solid State Relays 1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

Solid-state Contactor Specifications

Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection

Solid State Relays 1-Phase, Proportional Switching Controllers Types RGS1P..AA.., RGS1P..V..

Solid State Relays Zero Switching Types Solid State Contactor

1-Phase Integrated Heatsink Zero Cross or Instant On Switching

Subject to changes 11/2003 Page 1/7

2-pole solid state relays

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Solid State Relays Zero Switching Types RGC Solid State Contactor 'E' Connection

2PSS60A40 Solid State Relays 3-Phase with Integrated Heatsink

CP-T range Product group picture

Solid State Relays Industrial, 1Phase Peak Switching Type RM1C

2-pole solid state relays

Type CP-S, CP-C & CP-A Switch mode

Solid-state Contactor Specifications

Solid State Relays 3-Phase with Integrated Heatsink Types 2 & 3 Pole

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Power supply CP-D 24/4.2 Primary switch mode power supply

Electronic timer CT-TGD.22

Solid State Relay, 1-phase

CP-T range Benefits and advantages

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'E' Connection. Product Description RGC 1 A 60 A 30 K K E _.

Electronic timer CT-SDD.22

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Primary switch mode power supplies Product group picture

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

08/07/2015

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Solid State Relays 1-Phase with Integrated Heatsink Proportional Switching Controllers Types RGC1P..AA.., RGC1P..V..

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

CP-E range Benefits and advantages

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Starting Torque Controller Technical Data

Solid State Motor Contactor 3-Phase Types REC2B, REC3B

Power supply CP-E 24/20.0

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Three-phase monitoring relays CM-PFE and CM-PFE.2

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Power supply CP-D 24/1.3

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Solid State Relays 1-Phase with Integrated Heatsink Zero Cross Switching, 1600 Vp Blocking Voltage Types RGH

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Product Specification sheet

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Solid-State Relays Zero-point switching, without heatsink

Power supply CP-D 12/2.1

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

08/07/2015

05/09/2012

Power supply CP-E 24/2.5

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Three-phase monitoring relay CM-PVE

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays

Custom "Compact" range with display CD20 Custom Part number

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

High precision measurement system for current and voltage IHC-A/B-RM01/03

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Three-phase monitoring relay CM-PFS

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

02/11/2015

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-SDS.22

RN Thyristor Controllers

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

02/11/2015

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Three-phase monitoring relay

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Power supply CP-E 24/0.75

Zelio Control Measurement Relays

Transcription:

Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R AC electronic motor reversing relay Instantaneous switching Three phase with two pole switching Control status LED indication Two control input ranges: 15-32 VDC, 90-253 VAC Motor rating up to 3 kw (3.0 HP) @ 400 VAC Rated operational voltage up to 530 VAC Opto-isolation at 4 kvrms Mechanical contactor resemblance with covered heatsink DIN-rail and panel mounting Product Description REC2R is a 3-phase electronic motor reversing relay. L1-T1 and L3-T3 poles are switched while L2, T2 pole is a direct connection from L2 phase to the motor. A front dual colour LED, lights green when the motor is running in the forward direction upon application of control voltage to A2-A3 terminals. Motor runs in the reverse direction when control voltage is applied to terminals A1- A2 and the LE lights red. The integrated electronic interlock prevents short circuit between phases in case a control signal is applied for forward and reverse directions simultaneously through the pluggable connector on the front. In such a case REC switches off until one of the control signals is removed. REC can control motors up to 7.6 AAC. An adaptor for underlying overload modules is available. Specifications are stated at 25 C unless specified. Ordering Key Electronic Contactor Number of switched poles Switching mode Rated Operational Voltage Control voltage Motor Power rating High I TSM option Connection type for control Connection type for power Connection configuration REC 2 R 48 A 3 0 G K E Ordering Key Switching Switching Rated operational Control voltage Motor I TSM Connection Connection Configuration poles mode voltage power rating control control power REC2: 2 poles R: Reversing 48: 48-530 VAC D: 24 VDC, 3: 3.0 kw 0: Standard G: Clamp K: Screws E: Contactor -15%, + 20% I TSM A: 90-253 VAC Selection Guide Rated Voltage No. of Poles Control voltage Power Rating @ 400 VAC 3.0 kw 48-530 VAC 2 24 VDC REC2R48D30GKE 90-253 VAC REC2R48A30GKE Specifications are subject to change without notice (09.10.2018) 1

General Specifications Rated operational voltage Operational voltage range Blocking voltage Operational frequency range Power factor 480 VAC 48-530 VAC 1200 Vp 45-65 Hz >0.5 @ rated voltage Control Specifications REC...D.. REC...A.. Rated control input voltage 24 VDC 230 VAC Control voltage range 15-32 VDC 90-253 VAC (according to EN61131-2) Maximum Input current 10 ma 15 ma Pick-up voltage 15 VDC 90 VAC Maximum reverse voltage 32 VDC N/A Drop-out voltage 1 VDC 10 VAC Response time pick-up 5 ms 30 ms Response time drop-out 15 ms 30 ms Operational frequency range N/A 45-65 Hz Maximum time delay F- -> R, F <-- R 80 ms 100 ms LEDs Forward: Green Forward: Green Reverse: Red Reverse: Red Connection Specifications POWER CONNECTIONS (75 C,Copper Cables) CONTROL CONNECTIONS (75 C,Copper Cables) Connection Type Screw terminal Connection Type Captive Clamp Illustration of terminal Illustration of terminal Rigid (Solid) Finely stranded with end sleeve Flexible w/o end sleeves Stripping length Tightening torque Screw size Aperture for termination lug (fork type) 2 x 1.5..2.5mm² (2 x AWG16..14) 2 x 2.5..6mm² (2 x AWG14..10) 2 x 1..2.5mm² (2 x AWG17..14) 2 x 2.5..6mm² (2 x AWG14..10) 1 x 10mm² (1 x AWG8) 2 x 1.5..2.5mm² (2 x AWG16..14) 2 x 2.5..6mm² (2 x AWG14..10) 10mm 2Nm (Pozidriv 2 bit) M4 Max. 11 mm Type Stranded Solid Stripping length Tightening torque Screw Size Withdrawal Force 1.5N Insertion Force 3N Max Contact Resistance 15mΩ Pluggable 1 x 0.05..1.5mm² (1 x AWG30..16) 1 x 0.05..2.5mm² (1 x AWG30..14) 6-7.5mm 0.5Nm (Philips bit) M3 2 Specifications are subject to change without notice (09.10.2018)

Load Specifications @ 40 @ 50 @ 60 @ 40 @ 50 @ 60 I MIN I TSM Rated operational current AC-53a @ 400Vrms, to IEC, for trip classes 10, 20, 30 Horizontal space between units 45 mm 0 mm All Cases 7.6A 6.8A 6.2A 5.8A 5.8A 4.9A 400mA 600Ap No. of poles 2 Maximum On-state voltage drop @ rated current 1.6 Vrms Off-state leakage current @ rated voltage and frequency < 3 marms Critical dv/dt* 1000 V/μs * Specification @ Tj (init.) 25 o C and t 10 ms Motor Rating (45 mm space between adjacent units) HP @ 40 / 50 / 60 C, according to UL508 kw @ 40 / 50 / 60 C, according to IEC 60947-4-2 230V 400V 480V 600V 230V 400V 480V 600V 2 / 2 / 1 3 / 3 / 3 5 / 3 / 3-1.5 / 1.5 / 1.5 3.0 / 2. 2 / 2.2 4.0 / 3.0 / 3.0 - Environmental Specifications Housing Specifications Operating temperature -25 C to 60 C (-13 o F to +140 o F) Storage temperature -40 C to 100 C (-40 o F to +212 o F) EU RoHS compliant Yes China RoHS compliant Refer to Environmental Information (page 7) Impact resistance 15/11 g/ms Vibration resistance 2 g Relative humidity < 95% non-condensing @ 40 C Pollution degree 2 Installation category III Degree of finger protection IP20 Installation altitude 0-1000 m. Above 1000 m derate linearly by 1% of FLC per 100 m up to a maximum of 2000 m Weight Housing material Flame class Housing colour Dimensions (h x w x d) (without input plug) Isolation Dielectric withstand voltage input to output approx 300 g Nylon PA66 UL94-V0 RAL7035 105 x 45 x 90 mm 4000 VACrms Specifications are subject to change without notice (09.10.2018) 3

Short Circuit Protection (according to EN/IEC 60947-4-2 and UL508) Short Circuit Current Rating Type of coordination: 1 UL rated short circuit current RK5 fuse Type of coordination: 2 Rated short circuit Semiconductor fuse Agency Approvals and Conformances 5 ka 15 A Y220913 6.9 CP GRC 22.58 5 Conformance IEC/EN 60947-4-2 Agency Approvals UL508 Listed (E172877), NMFT cul Listed (E172877), NMFT7 Electromagnetic Compatibility EMC Immunity EN 60947-4-2 Electrostatic Discharge (ESD) Immunity IEC/EN 61000-4-2 Air discharge, 8 kv Performance Criteria 2 Contact, 4 kv Performance Criteria 1 Electrical Fast Transient (Burst) Immunity IEC/EN 61000-4-4 Output: 4 kv, 5 khz Performance Criteria 2 Output: 2 kv, 5 khz Performance Criteria 1 Input: 2 kv, 5 khz Performance Criteria 1 Electrical Surge Immunity IEC/EN 61000-4-5 Output, line to line, 1 kv Performance Criteria 1 Output, line to earth, 2 kv Performance Criteria 1 Input, line to line, 1 kv Performance Criteria 2 Input, line to earth, 2 kv Performance Criteria 2 Radiated Radio Frequency Immunity IEC/EN 61000-4-3 10 V/m, 80-1000 MHz Performance Criteria 1 10 V/m, 1.4-2 GHz Performance Criteria 1 10 V/m, 2-2.7 GHz Performance Criteria 1 Conducted Radio Frequency IEC/EN 61000-4-6 Immunity 10 V/m, 0.15-80 MHz Performance Criteria 1 Voltage Dips Immunity IEC/EN 61000-4-11 0% for 0.5, 1 cycle Performance Criteria 2 40% for 10 cycles Performance Criteria 2 70% for 25 cycles Performance Criteria 2 80% for 250 cycles Performance Criteria 2 Voltage Interruptions Immunity IEC/EN 61000-4-11 0% for 5000 ms Performance Criteria 2 EMC Emission EN 60947-4-2 Radio Interference Voltage Emission (Conducted) IEC/EN 55011 0.15-30MHz Class A (industrial)* Radio Interference Field Emission (Radiated) IEC/EN 55011 30-1000MHz Class B (light industry) * This product is designed and constructed as an EMC Class A device. The use of this product in residential applications could lead to radio interferences. In such applications, additional external filtering may be required. 4 Specifications are subject to change without notice (09.10.2018)

Connection Diagrams Forward (Clockwise) L1 L2 L3 L1 L2 L3 Reverse (Anticlockwise) 1L1 3L2 5L3 1L1 3L2 5L3 A1 A2 A3 A1 A2 A3 2T1 4T2 6T3 2T1 4T2 6T3 Motor 3 ~ - + (~) (~) Motor 3 ~ + - (~) (~) Dimensions 86 ± 0.5 mm 105 ± 0.5mm 55.1 ± 0.5mm 45mm max. 82.2 ± 0.5 mm 99.4 ± 0.5 mm All dimensions in mm Specifications are subject to change without notice (09.10.2018) 5

Characteristic Curves and Operating Cycles Maximum allowable number of starts depending on the T n and T on I n I L I n: Inrush current for direct on line starting I e I e: Rated full load current I L: Load Current T n T ON T e T x T n: Time during inrush current I n T e: Time during full load current I e or I L T x: Off time T ON T n + T e Curves: No. of switching cycles per hour versus t ON `Ü~êíkçKN In I L ZTKOI ZN I I í lk kìãäéêçñpïáíåüéëééêeçìê EëF q å ZMKMRë q å ZMKNë q å ZMKOë q å ZMKQë q å ZMKUë q å ZNKSë q å ZPKOë MKN NUMM VNM J J J J J N NRMM UMM QOM OOM NMO J J NM 3UM PMM OR0 NSM VM QM NR NMM PU PU PU PR PR OR S NMMM J J J J J J J `Ü~êíkçKO In I L ZTKOI ZMKS Ie Ie í lk kìãäéêçñpïáíåüéëééêeçìê EëF q å ZMKMRë q å ZMKNë q å ZMKOë q å ZMKQë q å ZMKUë q å ZNKSë q å ZPKOë MKN NVMM VMM J J J J J N NUMM URM QQM NOM NNM J J NM PVM PVM PRM NVM NMM RM OR NMM PU PU PU PU OR OR OM NMMM J J J J J J J `Ü~êíkçKP In I L ZQI ZN Ie Ie í lk kìãäéêçñpïáíåüéëééêeçìê EëF q å ZMKMRë q å ZMKNë q å ZMKOë q å ZMKQë q å ZMKUë q å ZNKSë q å ZPKOë MKN RNMM OUMM J J J J J N OTMM NVMM NNMM SRM PRM J J NM ORM ORM ORM OVM OMM NQM TR NMM PS PS PS PS PS PS PM NMMM J J J J J J J `Ü~êíkçKQ In I L ZQI ZMKS I I í lk kìãäéêçñpïáíåüéëééêeçìê EëF q å ZMKMRë q å ZMKNë q å ZMKOë q å ZMKQë q å ZMKUë q å ZNKSë q å ZPKOë MKN RRMM OVMM J J J J J N PQMM OPMM NQMM TMM PRM J J NM PRM PRM PRM PRM OUM NTM UM NMM PS PS PS PS PS PS PS NMMM J J J J J J J e e e e 6 Specifications are subject to change without notice (09.10.2018)

Environmental Information The declaration in this section is prepared in compliance with People s Republic of China Electronic Industry Standard SJ/ T11364-2014: Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products. Part Name Toxic or Harardous Substances and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr(Vl)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Power Unit Assembly x O O O O O O: Indicates that said hazardous substance contained in homogeneous materials fot this part are below the limit requirement of GB/T 26572. X: Indicates that said hazardous substance contained in one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. (Pb) (Hg) (Cd) (Cr(Vl)) (PBB) (PBDE) x O O O O O 25 Specifications are subject to change without notice (09.10.2018) 7

Accessories Motor overload Relay adapter.* Part Number: REC3ADAPTOR Pack qty.: 5 pcs Compatible with: Manufacturer Series Example ABB TA TA25DU-8.5 Siemens 3RU11 3RU1126-1FB0 * 1 adaptor is shipped with every REC unit 8 Specifications are subject to change without notice (09.10.2018)