LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Similar documents
LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Characteristics 5 TeSys k contactors and reversing contactors

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Modular equipment. Presentation, standards. Standard contactors TeSys GC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

Motor starters. TeSys E. Designed for the essential

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

NS..S contactor relays - with spring terminals AC operated

3 - Protection components Circuit-breakers

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

RENF22R2MMW Zelio Timer Relay - Modular

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Components for safety applications

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Electromechanical pressure and vacuum switches 0

Protection components

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Protection components

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

References 1 for asynchronous motors 1

Zelio Control Measurement Relays

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

38 Series - Relay interface modules A. Features /

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

48 Series - Relay interface modules A. Features

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Pendant control stations 6

Pendant control stations 6

Zelio Plug-In Relays. RXG interface relays. Catalog

Page 13-2 Page Page 13-7

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Classification Enclosure rating Contact form Contact material

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Electronic timer CT-SDD.22

Type: DILM40(RDC24) Article No.:

Type CP-S, CP-C & CP-A Switch mode

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Components for Marine applications

Transcription:

Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil Product availability : Stock - Normally stocked in distribution facility Price* : 149.00 USD Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power hp Control circuit type [Uc] control circuit voltage Auxiliary contact composition Nov 18, 2018 TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC power circuit <= 690 V AC 25...400 Hz power circuit 12 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 25 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 7.5 kw at 500 V AC 50/60 Hz AC-3 7.5 kw at 660...690 V AC 50/60 Hz AC-3 5.5 kw at 380...400 V AC 50/60 Hz AC-3 5.5 kw at 415...440 V AC 50/60 Hz AC-3 3 kw at 220...230 V AC 50/60 Hz AC-3 3.7 kw at 400 V AC 50/60 Hz AC-4 2 hp at 230/240 V AC 50/60 Hz 1 phase motors 3 hp at 200/208 V AC 50/60 Hz 3 phases motors 3 hp at 230/240 V AC 50/60 Hz 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz 3 phases motors 10 hp at 575/600 V AC 50/60 Hz 3 phases motors 0.5 hp at 115 V AC 50/60 Hz 1 phase motors DC standard 24 V DC 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Overvoltage category [Ith] conventional free air thermal current III 25 A at <= 140 F (60 C) power circuit 10 A at <= 140 F (60 C) signalling circuit Irms rated making capacity 250 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 250 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Protective cover Mounting support 105 A <= 104 F (40 C) 10 s power circuit 210 A <= 104 F (40 C) 1 s power circuit 30 A <= 104 F (40 C) 10 min power circuit 61 A <= 104 F (40 C) 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 25 A gg at <= 690 V coordination type 2 power circuit 40 A gg at <= 690 V coordination type 1 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 2.5 mohm at 50 Hz - Ith 25 A power circuit 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V 0.36 W AC-3 1.56 W AC-1 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - 2

Tightening torque Operating time Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 53.55...72.45 ms closing 16...24 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 30 Mcycles 3600 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Time constant Inrush power in W Hold-in power consumption in W With integral suppression device 0.1...0.25 Uc drop-out at 140 F (60 C), DC 0.7...1.25 Uc operational at 140 F (60 C), DC 28 ms 5.4 W at 68 F (20 C) 5.4 W at 68 F (20 C) Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact > 10 MOhm signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor open 10 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms 3.03 in (77 mm) 1.77 in (45 mm) 3.74 in (95 mm) 1.07 lb(us) (0.485 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 00785901207245 Nbr. of units in pkg. 1 Package weight(lbs) 1.1799999999999999 Returnability Y 3

Country of origin ID Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since 0627 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D12BD Dimensions (1) Minimum electrical clearance LC1 D09 D18 D093 D123 D099 D129 b 77 99 80 c without cover or add-on blocks 93 93 93 with cover, without add-on blocks 95 95 95 c1 with LAD N or C (2 or 4 contacts) 126 126 126 c2 with LA6 DK10 138 138 138 c3 with LAD T, R, S 146 146 146 with LAD T, R, S and sealing cover 150 150 150 5

Product data sheet Connections and Schema LC1D12BD Wiring 6