In the event of a failure, the inverter switches off and a fault code appears on the display.

Similar documents
13. Before making a service call Trip information and remedies

NX Series Inverters. HVAC Pocket Programming Guide

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

HPVFP High Performance Full Function Vector Frequency Inverter

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

MICROMASTER kw - 11 kw. Operating Instructions (Compact) Issue 10/06. www. ElectricalPartManuals. com. User Documentation

MICROMASTER kw - 11 kw

6.9 Jump frequency - Avoiding frequency resonance

Compact Operating Manual Issue 04/04. sinamics SINAMICS G110

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Troubleshooting Alarm Displays Warning Displays

PAM & SAM System User s Manual

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

[ 4 ] Using pulse train input (F01 = 12)

TOSVERT TM VF-nC3 Parameter List

Troubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Troubleshooting Alarm Displays Warning Displays

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

8V General information. 2 Order data 8V

NX series Constant and variable torque Variable Speed Drives for induction motors

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

ACH550 HVAC Drive Submittal

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

8V General information. 2 Order data 8V

Table 6.1 Fault Code List Code indication (Note 3)

E3 Adjustable Speed Drive Engineering Specification

Troubleshooting Alarm Displays Warning Displays

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

MICROMASTER 440. Parameter List Issue 01/06. User Documentation 6SE6400-5BB00-0BP0

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

vacon nx all in one application manual ac drives Phone: Fax: Web: -

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Error codes for REFUsol 012K/016K/020K/024K - UL

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

BACnet- MS/TP COMMUNICATION V

GS1 Parameter Summary Detailed Parameter Listings...4 9

Operating Instructions

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718*

Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19. Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW

Parameter Manual Edition 04/2006

user's manual nx frequency converters beam pump application asfiff13

smd frequency inverter

The new Yaskawa Varispeed G7 Inverter

S11 Adjustable Speed Drive Engineering Specification

PARAMETER LIST MICROFUSION

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

OPC-E1-PG3 Specifications

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

bbl base block 76 Power modules for motor de-excitation locked bon close brake 85 Brake control, brake engaged (see chapter 6.9)

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

MICROMASTER. Applications Handbook. User Documentation

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Application for Drive Technology

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

HOW TO CHECK SERVOPACK:

Multi-function, Compact Inverters. 3G3MV Series

Inverter Drive /Vector Drive Motors & Controls

Features: Phase A Phase B Phase C -DC_A -DC_B -DC_C

Special Internal Circuits

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Cover sheet. Handling the Demo Case. SINAMICS G120 with CU250S-2 Vector. FAQ October Service & Support. Answers for industry.

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

CSMIO/IP-A motion controller and Mach4

Phoenix DX Clean Power (18 Pulse) AC Drive

VF-nC1 Adjustable Speed Drive Engineering Specification

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

SX (400 V) System configuration

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

MD310 Quick Start Manual. General-Purpose AC Drive

Siemens Standard Drives. Application Handbook

vacon nxp arfiff30 user manual generator application ac drives

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

SINAMICS G120. Frequenzumrichter SINAMICS G120 SINAMICS G120D. Function Manual 08/2011 SINAMICS. Answers for industry.

Before you operate the inverter, the parameters that you must first program are the basic parameters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

CHAPTER 8 PARAMETER SUMMARY

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001

External brake resistor AX2090-BW5x

Function diagram MICROMASTER 420. Overview General Overview Modulator. Technology functions. Internal. External command + setpoint source

TENTATIVE PP225D120. POW-R-PAK TM 225A / 1200V Half Bridge IGBT Assembly. Description:

SX (690 V) System configuration

Multi-purpose Control Application II

WDBR Series (RoHS compliant)

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

7.2 DV1311.L08 and DV1311.L12

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

15P0059B3 DCREG2 DCREG4 USER MANUAL

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Transcription:

Issue 03/05 Faults and Alarms 5 Faults and Alarms 5.1 Fault messages In the event of a failure, the inverter switches off and a fault code appears on the display. NOTE To reset the fault code, one of three methods listed below can be used: 1. Cycle the power to the drive. 2. Press the button on the BOP or AOP. 3. Via Digital Input 3 (default setting) Fault messages are stored in parameter r0947 under their code number (e.g. F0003 = 3). The associated error value is found in parameter r0949. The value 0 is entered if a fault has no error value. It is furthermore possible to read out the point in time that a fault occurred (r0948) and the number of fault messages (P0952) stored in Parameter r0947. F0001 OverCurrent STOP II Remove fault and reset fault memory by disconnecting the - drive converter from the line supply and powering-up again - Press the Fn key on the BOP or AOP - Acknowledge fault P2103, P2104 - P0952 (complete fault memory) - Short circuit at the output - Earth faults - Excessively large motor - Defective end stage - Cable length limits must not be exceeded. - Motor cable and motor must have no short-circuits or earth faults - Motor parameters must match the motor in use - Value of stator resistance (P0350) must be correct - Motor must not be obstructed or overloaded - Increase the ramp time - Reduce the boost level - Connect a smaller motor (lower rating) F0002 OverVoltage STOP II - DC-link voltage (r0026) exceeds the overvoltage threshold (refer to parameter r0026) - Ground fault NOTE Overvoltage can be caused either by too high main supply voltage or if motor is in regenerative mode. Regenerative mode can be cause by fast ramp downs or if the motor is driven from an active load. 6SE6400-5BB00-0BP0 303

NI NORTHERN INDUSTRIAL WWW.NICONTROLS.COM ESTABLISHED IN 1978 Northern Industrial Thwaites Close Blackburn Lancashire BB1 2QQ United Kingdom NORTHERN INDUSTRIAL Northern Industrial is a leading global supplier of industrial automation parts and repairs based in the UK. We provide a wide range of automation solutions from sourcing obsolete parts to express repairs and new part upgrades. Visit nicontrols.com for more information. Cert No. 11848 ISO 9001: 2008 +44 (0) 1254 673747 info@nicontrols.com www.nicontrols.com

Faults and Alarms Issue 03/05 - Supply voltage (P0210) must lie within limits indicated on rating plate. - DC-link voltage controller must be enabled (P1240) and parameterized properly. - Extend the deceleration ramps (ramp-down time P1121, P1135) - Remove the ground fault - Required braking power must lie within specified limits. - Check the feeder cable to the braking resistor - Check the technical data of the braking resistor - Check the load duty cycle of the braking resistor with reference to the application NOTE Higher inertia requires longer ramp times; otherwise, apply braking resistor. F0003 UnderVoltage STOP II - Main supply failed. - Shock load outside specified limits. - Supply voltage (P0210) must lie within limits indicated on rating plate. - Supply must not be susceptible to temporary failures or voltage reductions. F0004 Inverter Over Temperature STOP II - Ventilation inadequate - Ambient temperature is too high. - Actual drive converter temperature r0037 exceeds the overtemperature threshold (refer to P0292) - Fan must turn when inverter is running - Pulse frequency must be set to default value - Ambient temperature could be higher than specified for the inverter - Reduce the load and / or ensure adequate cooling Additional meaning for frame sizes FX and GX: - P949 = 1: Rectifier overtemperature - P949 = 2: Ambient overtemperature - P949 = 3: EBOX overtemperature F0005 Inverter I2T STOP II - Inverter overloaded. - Duty cycle too demanding. - Motor power (P0307) exceeds inverter power capability (r0206). - 100 % overload reached (refer to utilization r0036 ) - Load duty cycle must lie within specified limits. - Motor power (P0307) must match inverter power (r0206) F0011 Motor Over Temperature STOP II Motor overloaded - Load duty cycle must be correct - Motor nominal overtemperatures (P0626-P0628) must be correct - Motor temperature warning level (P0604) must match - Voltage boost (increase) too high and / or frequency setpoint too low? - Adapt the motor cooling to the application 304 6SE6400-5BB00-0BP0

Issue 03/05 Faults and Alarms F0012 Inverter temp. signal lost STOP I Wire breakage of inverter temperature (heatsink) sensor F0015 Motor temperature signal lost STOP II Open or short circuit of motor temperature sensor. If signal loss is detected, temperature monitoring switches over to monitoring with the motor thermal model. F0020 Mains Phase Missing STOP II Fault occurs if one of the three input phases are missed and the pulses are enabled and drive is loaded check the input wiring of the mains phases F0021 Earth fault STOP II Fault occurs if the sum of the phase currents is higher than 5 % of the nominal inverter current. NOTE This fault only occurs on inverters that have 3 current sensors. Framesizes D to F F0022 HW monitoring active STOP II That hardware fault (P0947 = 22 and P0949 = 1) caused by the following events: (1) DC-link overcurrent = short circuit of IGBT (2) Short circuit of chopper (3) Earth fault (4) I/O board is not properly inserted. - Framesizes A to C (1),(2),(3),(4) - Framesizes D to E (1),(2),(4) - Framesize F (2),(4) Since all these faults are assigned to one signal on the power stack, it is not possible to establish which one actually occurred. The following faults (UCE and I2C) occur for frame size FX / GX only: - UCE failure was detected, when P0947 = 22 and fault value P0949 = 12 or 13 or 14, depending on UCE. - I2C bus read out error, when P0947 = 22 and fault value P0949 = 21 (the power has to be switched off/on). First you must see if the fault is permanent (i.e. the inverter cannot be started without the fault occurring) or sporadic (occurs occasionally or in certain defined operating conditions). Permanent F0022 fault: - Check the I/O board. It has to be fully pressed home. - Is there an earth fault or short circuit on the output of the inverter or in an IGBT? Disconnecting the motor cables will establish which of these. In the case where the fault occurs permanently when all external wiring (apart from mains) is disconnected, then the unit almost certainly has a defect and should be repaired. Sporadic F0022 fault: This should be treated as "overcurrent". The following may cause the sporadic occurrence of F0022: - Sudden load changes or mechanical blockages. - Very short ramp times. - If the Sensorless Vector Control is badly optimized. - If an incorrect braking resistor of too low a resistance is fitted. 6SE6400-5BB00-0BP0 305

Faults and Alarms Issue 03/05 F0023 Output fault STOP II One phase of output is disconnected F0024 Rectifier Over Temperature STOP II - Ventilation inadequate - Fan inoperative - Ambient temperature is too high. - Fan must turn when inverter is running - Pulse frequency must be set to default value - Ambient temperature could be higher than specified for the inverter F0030 Fan has failed STOP II Fan no longer working - Fault cannot be masked while options module (AOP or BOP) is connected. - Need a new fan. F0035 Auto restart after n STOP II reset fault memory or Power On / Stop Auto restart attempts exceed value of P1211. F0040 Automatic Calibration Failure STOP II A calibration error occurred when automatically calibrating the analog inputs / outputs or the current actual value sensing. In the factory, the calibration is only carried-out once. This means that fault F0040 is only to be expected during the production process of the drive converter and not while the converter is being used. Diagnostics and removing faults Replace the drive F0041 Motor Data Identification Failure STOP II Motor data identification failed. Alarm value = 0: Load missing Alarm value = 1: Current limit level reached during identification. Alarm value = 2: Identified stator resistance less than 0.1% or greater than 100%. Alarm value = 3: Identified rotor resistance less than 0.1% or greater than 100%. Alarm value = 4: Identified stator reactance less than 50% and greater than 500% Alarm value = 5: Identified main reactance less than 50% and greater than 500% Alarm value = 6: Identified rotor time constant less than 10ms or greater than 5s Alarm value = 7: Identified total leakage reactance less than 5% and greater than 50% Alarm value = 8: Identified stator leakage reactance less than 25% and greater than 250% Alarm value = 9: Identified rotor leakage inductance less than 25% and greater than 250% Alarm value = 20: Identified IGBT on-voltage less than 0.5 or greater than 10V Alarm value = 30: Current controller at voltage limit Alarm value = 40: Inconsistence of identified data set, at least one identification failed Percentage values based on the impedance Zb = Vmot,nom / sqrt(3) / Imot,nom 306 6SE6400-5BB00-0BP0

Issue 03/05 Faults and Alarms - 0: Check that the motor is connected to the inverter. - 1-40: Check if motor data in P0304 P0311 are correct. - Check what type of motor wiring is required (star, delta). F0042 Speed Control Optimisation Failure STOP II - Motor data identification failed. - Alarm value = 0: Time out waiting for stable speed - Alarm value = 1: Inconsistent readings F0051 Parameter EEPROM Fault STOP II Read or write failure while saving non-volatile parameter. - Factory Reset and new parameterization - Change drive F0052 power stack Fault STOP II Read failure for power stack information or invalid data. Change drive F0053 IO Eeprom Fault STOP II Read failure for IO EEPROM information or invalid data. - Check data - Change IO module F0054 Wrong IO Board STOP II - Wrong IO board is connected. - No ID detected on IO board, No data. - Check data - Change IO module F0060 Asic Timeout STOP II Internal communications failure - If fault persists, change inverter - Contact Service Department 6SE6400-5BB00-0BP0 307

Faults and Alarms Issue 03/05 F0070 CB setpoint fault STOP II No setpoint values from CB (communication board) during telegram off time Check CB and communication partner F0071 USS (BOP-link) setpoint fault STOP II No setpoint values from USS during telegram off time Check USS master F0072 USS (COMM link) setpoint fault STOP II No setpoint values from USS during telegram off time Check USS master F0080 ADC lost input signal STOP II - Broken wire - Signal out of limits F0085 External Fault STOP II External fault triggered via terminal inputs Disable terminal input for fault trigger. F0090 Encoder feedback loss STOP II Signal from Encoder lost (check alarm value r0949): - Alarm value = 0: Encoder signal lost. - Alarm value = 5: Encoder not configured in P0400, but required for sensored control (P1300 = 21 or 23). - Alarm value = 6: Encoder module not found, but configured in P0400. - Check connections between encoder and inverter. Check that encoder not faulty (select P1300 = 0, run at fixed speed, check encoder feedback signal in r0061) - Increase encoder loss threshold in P0492 F0101 Stack Overflow STOP II Software error or processor failure Run self test routines 308 6SE6400-5BB00-0BP0

Issue 03/05 Faults and Alarms F0221 PID Feedback below min. value STOP II PID Feedback below min. value P2268. - Change value of P2268. - Adjust feedback gain. F0222 PID Feedback above max. value STOP II PID feedback above max. value P2267. - Change value of P2267. - Adjust feedback gain. F0450 BIST Tests Failure STOP II Fault value: 1. Some power section tests have failed 2. Some control board tests have failed 4. Some functional tests have failed 8. Some IO module tests have failed. (MM 420 only) 16. Internal RAM failed on power-up check Drive may run but some features will not work properly. Replace drive. F0452 Belt Failure Detected STOP II Load conditions on motor indicate belt failure or mechanical fault. 1. No breakage, seizure or obstruction of drive train. 2. If using an external speed sensor, check for correct function. Check parameters: - P2192 (delay time for permitted deviation) 3. If using the torque envelope, check parameters: - P2182 (threshold frequency f1) - P2183 (threshold frequency f2) - P2184 (threshold frequency f3) - P2185 (upper torque threshold 1) - P2186 (lower torque threshold 1) - P2187 (upper torque threshold 2) - P2188 (lower torque threshold 2) - P2189 (upper torque threshold 3) - P2190 (lower torque threshold 3) - P2192 (delay time for permitted deviation) 4. Apply lubrication if required. 6SE6400-5BB00-0BP0 309

Faults and Alarms Issue 03/05 5.2 Alarm Messages Alarm messages are stored in parameter r2110 under their code number (e.g. A0503 = 503) and can be read out from there. A0501 Current Limit - Motor power does not correspond to the inverter power - Motor leads are too long - Earth faults - Motor power (P0307) must correspond to inverter power (r0206). - Cable length limits must not be exceeded. - Motor cable and motor must have no short-circuits or earth faults - Motor parameters must match the motor in use - Value of stator resistance (P0350) must be correct - Motor must not be obstructed or overloaded - Increase the ramp-up-time. - Reduce the boost. A0502 Overvoltage limit Overvoltage limit is reached. This warning is generated, - if the dc-link controller is disabled (P1240 = 0). - if pulses are enabled - if actual dc voltage r0026 > r1242. If this warning is displayed permanently, check drive input voltage. A0503 UnderVoltage Limit - Main supply failed - Main supply (P0210) and consequently DC-link voltage (r0026) below specified limit (refer to parameter r0026). Overvoltage can be caused either by too high main supply voltage or if motor is in regenerative mode. Check main supply voltage (P0210). A0504 Inverter OverTemperature Warning level of inverter heat-sink temperature (P0614) is exceeded, resulting in pulse frequency reduction and/or output frequency reduction (depending on parameterization in (P0610) - Ambient temperature must lie within specified limits - Load conditions and duty cycle must be appropriate A0505 Inverter I2T - Overload alarm limit P0294 is exceeded (refer to utilization r0036) - Pulse frequency and output frequency are reduced as a function of the parameter setting P0290. Check that duty cycle lies within specified limits A0506 Inverter duty cycle Difference between heatsink and IGBT junction temperature exceeds warning limits Check that duty cycle and shock loads lie within specified limits 310 6SE6400-5BB00-0BP0

Issue 03/05 Faults and Alarms A0511 Motor Over Temperature - Motor overloaded. - Load duty cycle too high. Independently of the kind of temperature determination check: - P0604 motor temperature warning threshold - P0625 motor ambient temperature - If (P0601 = 0 or 1) 1. Check if name plate data are correct (if not perform quick commissioning) 2. Accurate equivalent circuit data can be found by performing motor identification (P1910=1). 3. Check if motor weight (P0344) is reasonable. Change if necessary. 4. Via P0626, P0627, P0628 the standard overtemperatures can be changed, if the motor is not a Siemens standard motor. - If (P601 = 2) 1. Check if temperature shown in r0035 is reasonable. 2. Check if the sensor is a KTY84 (other sensors are not supported) A0520 Rectifier OverTemperature Warning level of rectifier heat-sink temperature (P) is exceeded - Ambient temperature must lie within specified limits - Load conditions and duty cycle must be appropriate - Fan must turn when drive is running A0521 Ambient OverTemperature Warning level of ambient temperature (P) is exceeded - Ambient temperature must lie within specified limits - Fan must turn when drive is running - Fan intake air has to be without any resistance A0522 I2C read out timeout the cyclic access to the UCE Values and powerstack temperatures via the i2c bus (only for frame sizes FX and GX) is disturbed A0523 Output fault One phase of output is disconnected Warning can be masked. A0535 A0541 Braking Resistor Hot Motor Data Identification Active Motor data identification (P1910) selected or running A0542 Speed Control Optimization Active Speed Control Optimization (P1960) is selected or running 6SE6400-5BB00-0BP0 311

Faults and Alarms Issue 03/05 A0590 Encoder feedback loss warning Signal from Encoder lost; Inverter might have switched to sensorless vector control(check also alarm value r0949): Stop inverter and then - Check encoder fitted. If encoder fitted and r0949 = 5, select encoder type via P0400. - If encoder fitted and r0949 = 6, check connections between encoder module and inverter. - If encoder not fitted and r0949 = 5, select SLVC mode (P1300 = 20 or 22). - If encoder not fitted and r0949 = 6, set P0400 = 0. - Check connections between encoder and inverter - Check that encoder not faulty (select P1300 = 0, run at fixed speed, check encoder feedback signal in r0061) - Increase encoder loss threshold in P0492 A0600 A0700 A0701 A0702 A0703 A0704 A0705 A0706 A0707 A0708 A0709 A0710 RTOS Overrun Warning CB warning 1 see CB manual for details. CB warning 2 see CB manual for details. CB warning 3 see CB manual for details. CB warning 4 see CB manual for details. CB warning 5 see CB manual for details. CB warning 6 see CB manual for details. CB warning 7 see CB manual for details. CB warning 8 see CB manual for details. CB warning 9 see CB manual for details. CB warning 10 see CB manual for details. CB communication error Communication with CB (communication board) is lost Check CB hardware A0711 CB configuration error CB (communication board) reports a configuration error. Check CB parameters 312 6SE6400-5BB00-0BP0

Issue 03/05 Faults and Alarms A0910 Vdc-max controller de-activated Vdc max controller has been de-activated, since controller is not capable of keeping DC-link voltage (r0026) within limits (refer to r0026 and P1240). - Occurs if main supply voltage (P0210) is permanently too high. - Occurs if motor is driven by an active load, causing motor to goes into regenerative mode. - Occurs at very high load inertias, when ramping down. - Input voltage (P0210) must lie within range. - Load must be match. A0911 Vdc-max controller active Vdc max controller is active; so ramp-down times will be increased automatically to keep DC-link voltage (r0026) within limits (refer to r0026 and P1240). A0912 Vdc-min controller active - Vdc min controller will be activated if DC-link voltage (r0026) falls below minimum level (refer to r0026 and P1240). - The kinetic energy of the motor is used to buffer the DC-link voltage, thus causing deceleration of the drive! - So short mains failures do not necessarily lead to an undervoltage trip. A0920 ADC parameters not set properly. ADC parameters should not be set to identical values, since this would produce illogical results. - Index 0: Parameter settings for output identical - Index 1: Parameter settings for input identical - Index 2: Parameter settings for input do not correspond to ADC type A0921 DAC parameters not set properly. DAC parameters should not be set to identical values, since this would produce illogical results. - Index 0: Parameter settings for output identical - Index 1: Parameter settings for input identical - Index 2: Parameter settings for output do not correspond to DAC type A0922 No load applied to inverter No Load is applied to the inverter. As a result, some functions may not work as under normal load conditions. A0923 Both JOG Left and JOG Right are requested Both JOG right and JOG left (P1055/P1056) have been requested. This freezes the RFG output frequency at its current value. Do not press JOG right and left simultaneously. 6SE6400-5BB00-0BP0 313

Faults and Alarms Issue 03/05 A0952 Belt Failure Detected Load conditions on motor indicate belt failure or mechanical fault. 1. No breakage, seizure or obstruction of drive train. 2. If using an external speed sensor, check for correct function. Check parameters: - P0409 (pulse per min at rated speed). - P2191 (Belt failure speed tolerance). - P2192 (delay time for permitted deviation) 3. If using the torque envelope, check parameters: - P2182 (threshold frequency f1) - P2183 (threshold frequency f2) - P2184 (threshold frequency f3) - P2185 (upper torque threshold 1) - P2186 (lower torque threshold 1) - P2187 (upper torque threshold 2) - P2188 (lower torque threshold 2) - P2189 (upper torque threshold 3) - P2190 (lower torque threshold 3) - P2192 (delay time for permitted deviation) 4. Apply lubrication if required. A0936 PID Autotuning Active PID Autotuning (P2350) selected or running 314 6SE6400-5BB00-0BP0