ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Similar documents
ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

References 1 for asynchronous motors 1

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Electronic timer CT-SDD.22

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

RE17LLBM asymmetrical flashing relay s V AC - solid state output

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-SDS.22

Electronic timer CT-TGD.22

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Protection components

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Zelio Control Measurement Relays

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

RENF22R2MMW Zelio Timer Relay - Modular

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

08/07/2015

ATV12H018M3 frekv.pretvarač promj.brzine ATV12 0,18 KW 0,25 ks V 3 faze

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relays

Three-phase monitoring relays CM-PFE and CM-PFE.2

02/11/2015

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Power supply CP-D 24/1.3

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

22/10/2012

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

02/11/2015

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Three-phase monitoring relay

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

CP-T range Product group picture

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Subject to changes 11/2003 Page 1/7

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-MFS.21

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power supply CP-D 24/4.2 Primary switch mode power supply

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

CP-T range Benefits and advantages

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

02/11/2015

Three-phase monitoring relay

02/11/2015

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Transcription:

Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device short name Network number of phases Jan 01, 2018 Soft starter Asynchronous motors Simple machine ATS01 1 phase [Us] rated supply voltage 110...480 V - 10...10 % Motor power kw Motor power hp IcL starter rating 2.2 kw 3 phases 230 V 5.5 kw 3 phases 400 V 1.5 kw 1 phase 230 V 3 hp 3 phases 230 V 1.5 hp 3 phases 210 V 7.5 hp 3 phases 460 V 12 A Utilisation category AC-53B EN/IEC 60947-4-2 Current consumption Type of start Power dissipation in W Complementary Assembly style Function available Supply voltage limits 60 A at nominal load Start with voltage ramp 1 W at full load and at end of starting 61 W in transient state With heat sink Integrated bypass 99...528 V Supply frequency 50...60 Hz - 5...5 % Network frequency Output voltage [Uc] control circuit voltage 47.5...63 Hz <= power supply voltage 24 V AC/DC +/- 10 % 30 ma 110 V AC +/- 10 % 35 ma 240 V AC +/- 10 % 80 ma Starting time 1 s 100 5 s 20 Adjustable from 1 to 5 s Starting torque 30...80 % of starting torque of motor connected directly on the line supply 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Discrete output current Tightening torque Electrical connection Marking Operating position Height Width Depth Product weight Compatibility code Power range Motor starter type 2 A DC-13 3 A AC-15 1.9...2.5 N.m 0.5 N.m 4 mm screw clamp terminal rigid 1 1...10 mm² AWG 8 power circuit Screw connector rigid 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal rigid 2 1...6 mm² AWG 10 power circuit Screw connector rigid 2 0.5...1 mm² AWG 17 control circuit Screw connector flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit 4 mm screw clamp terminal flexible without cable end 1 1.5...10 mm² AWG 8 power circuit Screw connector flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal flexible with cable end 2 1...6 mm² AWG 10 power circuit 4 mm screw clamp terminal flexible without cable end 2 1.5...6 mm² AWG 10 power circuit Screw connector flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit CE Vertical +/- 10 degree 124 mm 45 mm 131 mm 0.28 kg ATS01N1 2.2...3 kw at 200...240 V 3 phases 4...6 kw at 380...440 V 3 phases 1.1...2 kw at 200...240 V 1 phase Soft starter Environment Electromagnetic compatibility Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/Current impulse level 3 IEC 61000-4-5 Conducted and radiated emissions level B CISPR 11 Conducted and radiated emissions level B IEC 60947-4-2 EMC immunity EN 50082-2 Harmonics IEC 1000-3-2 Harmonics IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6 Micro-cuts and voltage fluctuation IEC 61000-4-11 EMC immunity EN 50082-1 Standards EN/IEC 60947-4-2 Product certifications IP degree of protection B44.1-96/ASME A17.5 for starter wired to the motor delta terminal UL CSA CCC C-Tick GOST IP20 Pollution degree 2 EN/IEC 60947-4-2 Vibration resistance 1.5 mm peak to peak 3...13 Hz EN/IEC 60068-2-6 1 gn 13...150 Hz EN/IEC 60068-2-6 Shock resistance 15 gn 11 ms EN/IEC 60068-2-27 Relative humidity 5...95 % without condensation or dripping water EN/IEC 60068-2-3 Ambient air temperature for operation -10...40 C without derating 40...50 C with current derating of 2 % per C Ambient air temperature for storage -25...70 C EN/IEC 60947-4-2 Operating altitude <= 1000 m without derating > 1000 m with current derating of 2.2 % per additional 100 m Contractual warranty Warranty period 18 months 2

Dimensions Drawings Dimensions Mounting on Symetrical (35 mm) Rail Screw Fixing (1) Retractable fixings 3

Connections and Schema Example of 3-phase Power Supply Connection (1) A line contactor must be used in the sequence. A1 : Soft starter Q1 : Motor circuit-breaker KM1 : Contactors F1, F2 : Control protection fuses S1, S2 : Pushbuttons 4

Technical Description Function Diagram Us : Uc : LED 1 : LED 2 : Um : Power supply voltage Control supply voltage Green LED Yellow LED Motor voltage 5