Calibration Report. Short Version. UltraCam Eagle, S/N UC-E f210. Vexcel Imaging GmbH, A-8010 Graz, Austria

Similar documents
Calibration Report. Short Version. UltraCam L, S/N UC-L Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short Version. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short version. UltraCam Xp, S/N UC-SXp Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. Short version. UltraCam X, S/N UCX-SX Microsoft Photogrammetry, A-8010 Graz, Austria. ( 1 of 13 )

Calibration Report. UltraCam Eagle, S/N UC-Eagle f80. Vexcel Imaging GmbH, A-8010 Graz, Austria

Calibration Report. UC-SXp Version of Report:

Calibration Report. Vexcel Imaging GmbH, A-8010 Graz, Austria

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC IIe

Camera Calibration Certificate No: DMC II Aero Photo Europe Investigation

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC III 27542

CALIBRATING THE NEW ULTRACAM OSPREY OBLIQUE AERIAL SENSOR Michael Gruber, Wolfgang Walcher

Camera Calibration Certificate No: DMC II

UltraCam Eagle Prime Aerial Sensor Calibration and Validation

Vexcel Imaging GmbH Innovating in Photogrammetry: UltraCamXp, UltraCamLp and UltraMap

PROPERTY OF THE LARGE FORMAT DIGITAL AERIAL CAMERA DMC II

Calibration Certificate

ULTRACAM EAGLE MARK 3. One system for endless possibilities

ULTRACAMX AND A NEW WAY OF PHOTOGRAMMETRIC PROCESSING

NEWS FROM THE ULTRACAM CAMERA LINE-UP INTRODUCTION

UltraCam and UltraMap An Update

CALIBRATION REPORT SUMMARY

Update on UltraCam and UltraMap technology

TELLS THE NUMBER OF PIXELS THE TRUTH? EFFECTIVE RESOLUTION OF LARGE SIZE DIGITAL FRAME CAMERAS

Geometric Analysis of DMC II 140

UltraCam and UltraMap Towards All in One Solution by Photogrammetry

Technical Evaluation of Khartoum State Mapping Project

POTENTIAL OF LARGE FORMAT DIGITAL AERIAL CAMERAS. Dr. Karsten Jacobsen Leibniz University Hannover, Germany

Aerial Triangulation Radiometry Essentials Dense Matching Ortho Generation

CALIBRATION OF IMAGING SATELLITE SENSORS

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Xenon-Diamond 2.9/106 With beam splitter

Planet Labs Inc 2017 Page 2

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

Digital airborne cameras Status & future

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

Leica RCD30 Calibration Certificate

** KEYSTONE AERIAL SURVEYS R. David Day, Wesley Weaver **

Geometric Property of Large Format Digital Camera DMC II 140

CALIBRATION OF OPTICAL SATELLITE SENSORS

Geometry perfect Radiometry unknown?

EuroSDR project. Digital Camera Calibration. Michael Cramer. Presentation of project proposal

Aerial photography: Principles. Frame capture sensors: Analog film and digital cameras

APPLICATION AND ACCURACY POTENTIAL OF A STRICT GEOMETRIC MODEL FOR ROTATING LINE CAMERAS

DIGITAL IMAGING. Handbook of. Wiley VOL 1: IMAGE CAPTURE AND STORAGE. Editor-in- Chief

LEICA Summarit-S 70 mm ASPH. f/2.5 / CS

HIGH RESOLUTION IMAGERY FOR MAPPING AND LANDSCAPE MONITORING

Phase One ixu-rs1000 Accuracy Assessment Report Yu. Raizman, PhaseOne.Industrial, Israel

ENHANCEMENT OF THE RADIOMETRIC IMAGE QUALITY OF PHOTOGRAMMETRIC SCANNERS.

Consumer digital CCD cameras

Digital Aerial Photography UNBC March 22, Presented by: Dick Mynen TDB Consultants Inc.

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

Airborne or Spaceborne Images for Topographic Mapping?

Geometry of Aerial Photographs

Metric Accuracy Testing with Mobile Phone Cameras

ABOUT FRAME VERSUS PUSH-BROOM AERIAL CAMERAS

PERFORMANCE EVALUATIONS OF MACRO LENSES FOR DIGITAL DOCUMENTATION OF SMALL OBJECTS

While film cameras still

DMC PRACTICAL EXPERIENCE AND ACCURACY ASSESSMENT

The Airphoto Ortho Suite is an add-on to Geomatica. It requires Geomatica Core or Geomatica Prime as a pre-requisite.

Opto Engineering S.r.l.

Xenon-Zirconia 3.3/92

DMC The Digital Sensor Technology of Z/I-Imaging

Variable microinspection system. system125

AERIAL SURVEY TEST PROJECT WITH DJI PHANTOM 3 QUADROCOPTER DRONE

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

HIGH RESOLUTION COLOR IMAGERY FOR ORTHOMAPS AND REMOTE SENSING. Author: Peter Fricker Director Product Management Image Sensors

UltraCam and UltraMap An Update

Distagon T* 4/40 ZH The Super Sharp Super Wide

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

Basler Accessories. Technical Specification BASLER LENS C M. Order Number

QUALITY COMPARISON OF DIGITAL AND FILM-BASED IMAGES FOR PHOTOGRAMMETRIC PURPOSES Roland Perko 1 Andreas Klaus 2 Michael Gruber 3

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Lecture 2. Electromagnetic radiation principles. Units, image resolutions.

LECTURE NOTES 2016 CONTENTS. Sensors and Platforms for Acquisition of Aerial and Satellite Image Data

Ground Control Configuration Analysis for Small Area UAV Imagery Based Mapping

INCREASING GEOMETRIC ACCURACY OF DMC S VIRTUAL IMAGES

RADIOMETRIC CAMERA CALIBRATION OF THE BiLSAT SMALL SATELLITE: PRELIMINARY RESULTS

Digital Photogrammetry. Presented by: Dr. Hamid Ebadi

Angle of View & Image Resolution

technology meets pathology Institute of Pathology, Charité Universitätsmedizin Berlin, Berlin, Germany 3 Overview

ECEN 4606, UNDERGRADUATE OPTICS LAB

Geometric optics & aberrations

Figure 1 - The Main Screen of the e-foto Photogrammetric Project Creation and Management

DEVELOPMENT AND APPLICATION OF AN EXTENDED GEOMETRIC MODEL FOR HIGH RESOLUTION PANORAMIC CAMERAS

CHARACTERISTICS OF REMOTELY SENSED IMAGERY. Spatial Resolution

Introduction to Computer Vision

A 3D Multi-Aperture Image Sensor Architecture

INTEGRATED DEM AND PAN-SHARPENED SPOT-4 IMAGE IN URBAN STUDIES

CEE 6100 / CSS 6600 Remote Sensing Fundamentals 1 Topic 4: Photogrammetry

A European Network on Digital Camera Calibration

CALIBRATING DIGITAL PHOTOGRAMMETRIC AIRBORNE IMAGING SYSTEMS IN A TEST FIELD

Angle of View & Image Resolution

High Resolution Sensor Test Comparison with SPOT, KFA1000, KVR1000, IRS-1C and DPA in Lower Saxony

ABOUT RESOLUTION. pco.knowledge base

EXAMPLES OF TOPOGRAPHIC MAPS PRODUCED FROM SPACE AND ACHIEVED ACCURACY CARAVAN Workshop on Mapping from Space, Phnom Penh, June 2000

RADIOMETRIC CALIBRATION OF INTENSITY IMAGES OF SWISSRANGER SR-3000 RANGE CAMERA

Transcription:

Calibration Report Short Version Camera: Manufacturer: Date of Calibration: Date of Report: Revision of Camera: Version of Report: UltraCam Eagle, S/N UC-E-1-00518105-f210 Vexcel Imaging GmbH, A-8010 Graz, Austria Feb-20-2014 Feb-25-2014 Rev06 V01 Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 1 of 14

Calibration Report Geometric Calibration Camera: Manufacturer: Panchromatic Camera: Multispectral Camera: Date of Calibration: Date of Report: Revision of Camera: Version of Report: UltraCam Eagle, S/N UC-E-1-00518105-f210 Vexcel Imaging GmbH, A-8010 Graz, Austria ck = 210.750 mm ck = 210.750 mm Feb-20-2014 Feb-25-2014 Rev06 V01 Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 2 of 14

Panchromatic Camera Large Format Panchromatic Output Image Image Format long track 68.016mm 13080pixel cross track 104.052mm 20010pixel Image Extent (-34.01, -52.02)mm (34.01, 52.02)mm Pixel Size 5.200µm*5.200µm Focal Length ck 210.750 mm ± 0.002mm Principal Point X_ppa 0.000 mm ± 0.002mm (Level 2) Y_ppa 0.000 mm ± 0.002mm Lens Distortion Remaining Distortion less than 0.002mm Multispectral Camera Medium Format Multispectral Output Image (Upscaled to panchromatic image format) Image Format long track 68.016mm 4360pixel cross track 104.052mm 6670pixel Image Extent Pixel Size (-34.01, -52.02)mm (34.01, 52.02)mm 15.600µm*15.600µm Focal Length ck 210.750 mm Principal Point X_ppa 0.000 mm ± 0.002mm (Level 2) Y_ppa 0.000 mm ± 0.002mm Lens Distortion Remaining Distortion less than 0.002mm Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 3 of 14

Full Pan Image, Residual Error Diagram Residual Error (RMS): 0.56 µm Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 4 of 14

Explanations: 1) Calibration Method: The geometric calibration is based on a set of 84 images of a defined geometry target with 394 GCPs. Number of point measurements for the panchromatic camera : 14125 Number of point measurements for the multispectral camera : 54638 Determination of the image parameters by Least Squares Adjustment. Software used for the adjustment: BINGO (GIP Eng. Aalen, Germany) 2) Level 2 Image Coordinate System: PAN 20010 pixel by 13080 pixel MS 6670 pixel by 4360 pixel The image coordinate system of the Level 2 images is shown in the above figure. The level 2 image consists of 20010 columns and 13080 rows, which leads to a total image format of 104.052 x 68.016 mm. The coordinate of the principal point in the level 2 image is given on page 3 of this report. The above figure shows the position of an example principal point at the coordinate (-0.123 / 0.345). Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 5 of 14

3) Level 3 Image Coordinate System: PAN 20010 pixel by 13080 pixel (after rotation of 270 CW) MS 6670 pixel by 4360 pixel Panchromatic Image Format Multispectral Image Format ================================================================ 4) Position of Principal Point in Level 3 Image The position of the principal point in the level 3 image depends on the rotation setting used in UltraMap during the pan-sharpening step. The exact position relative to the image center is given in the table below as a function of the rotation setting used in UltraMap. The coordinates are specified for clockwise (CW) rotation in steps of 90 degrees, according to the principal point coordinate given on page 3 for high- and low resolution images. Image Format Clockwise Rotation (Degree) PPA Level 2-0.000 0.000 Level 3 0 0.000 0.000 Level 3 90 0.000 0.000 Level 3 180 0.000 0.000 Level 3 270 0.000 0.000 X Y Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 6 of 14

The coordinates in the figure below are only example values to illustrate the effect of image rotation on the principal point position, and do not correspond to the camera described in this report. Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 7 of 14

Lens Resolving Power The following curves show the development of the modulation transfer function across different image heights of the panchromatic cones. Please note that these values have been calculated and can vary up to 10% with optics from production (especially at high LP s). The curves are given for the meridonial (tangential) and sagital (radial) component of signals at frequencies of 12.5, 25, 50 and 100 line pairs per millimeter. As the MTF is a function of the specific aperture size used, one set of curves is given for each aperture size. Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 8 of 14

Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 9 of 14

Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 10 of 14

Spectral Sensitivity Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 11 of 14

Aperture UltraCamEagle, Serial Number UC-E-1-00518105-f210 Calibration Report Radiometric Calibration Camera: Manufacturer: UltraCam Eagle, S/N UC-E-1-00518105-f210 Vexcel Imaging GmbH, A-8010 Graz, Austria PAN R, G, NIR B F8 F5.6 F5.6 F9.5 F6.7 F5.6 F11 F8 F5.6 F13 F9.5 F6.7 F16 F11 F8 F22 F16 F11 Date of Calibration: Date of Report: Revision of Camera: Version of Report: Feb-20-2014 Feb-25-2014 Rev06 V01 Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 12 of 14

Explanations: Calibration Method: The radiometric calibration is based on a series of 50 flat field images for each aperture size and sensor. The flat field is illuminated by eight normal light lamps with known spectral illumination curves. These images are used to calculate the specific sensitivity of each pixel to compensate local as well as global variations in sensitivity. Sensitivity tables are calculated for each sensor and aperture setting, and applied during post processing from level 0 to level 1. Outlier Pixels that do not have a linear behavior as described in the CCD specifications are marked as defective during the calibration procedure. These pixels are not used or only partially used during post processing and the information is restored by interpolation between the neighborhood pixels surrounding the defective pixels. Certain pixels that are named Qmax pixels due to the fact that they can only store and transfer charge up to a certain maximum amount are detected in an additional calibration step. These pixels are treated differently during post processing, since their behavior can affect not only single pixel values but whole columns. Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 13 of 14

Calibration Report Summary Camera: Manufacturer: Date of Calibration: Date of Report: Revision of Camera: Version of Report: UltraCam Eagle, S/N UC-E-1-00518105-f210 Vexcel Imaging GmbH, A-8010 Graz, Austria Feb-20-2014 Feb-25-2014 Rev06 V01 The following calibrations have been performed for the above mentioned digital aerial mapping camera: - Geometric Calibration - Verification of Lens Quality and Sensor Adjustment - Radiometric Calibration - Calibration of Defective Pixel Elements - Shutter Calibration - Sensor and Electronics Calibration This equipment is operating fully within specification as defined by Vexcel Imaging GmbH. Dr. Michael Gruber Chief Scientist, Photogrammetry Vexcel Imaging GmbH Ing. Peter Prassl Senior Calibration Engineer Vexcel Imaging GmbH Phone: +43-316-849-0660 Fax: +43-316-849-0669 www.microsoft.com/ultracam Page 14 of 14