Digital Multimeter with Backlight

Similar documents
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL

Model DIGITAL MULTIMETER

AMM-1022 Digital Multimeter USER`S MANUAL

M-1000D DIGITAL MULTIMETER

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DIGITAL MULTIMETER AUTORANGING

DMM8900 SERIES USERS MANUAL

Digital Multimeter, Pen Type

DIGIT & POINTER MULTIMETER

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DIGITAL MULTIMETER INSTRUCTION MANUAL

Pocket Size Digital Multimeter Models: and

Digital Clamp Meter Model: &

3B SCIENTIFIC PHYSICS

MODEL: D03128 CLAMP METER

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

DVM1190 DIGITAL MULTIMETER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

770E DIGITAL MULTIMETER OPERATOR S MANUAL

User Manual Digital Multimeter

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

ProfiScale MULTI Multimeter

Sales: Technical: Fax:

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Model : OPERATING MANUAL Table of Contents (1)

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

AC/DC CLAMP METER USER S MANUAL

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

VC835 DIGTAL MULTIMETER Operation Manual

AVM360 Analog multimeter OPERATION MANUAL GEBRUIKERSHANDLEIDING MANUEL D UTILISATEUR

Mini Clamp Meter Model:

Multifunction Digital

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Digital Multimeter AX-572. Instruction manual

AUTO RANGING DIGITAL MULTIMETER

Handheld Digital Multimeter PRO-50A

True RMS Digital Multimeter Model:

Table of Contents Title Page

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Model: &

Digital Clamp Meter. User Manual

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

DIGITAL MULTIMETER OPERATOR S MANUAL

KMD-S04 Multímetro de bolsillo

Model UT39A/B/C: OPERATING MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MS8223A. CAT.IIi 600 V

Pen-type DIGITAL MULTITESTER

USER'S MANUAL DMR-4300

ET-3888 True RMS Clamp Meter. User Manual

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

DIGITAL MULTIMETER AX-588B

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Pocket Size Digital Multimeter with USB Model: A & A

4.5 Auto Power Off During use Preparation For Measurement Symbols...3

USER'S MANUAL DMR-6700

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

OPERATOR S INSTRUCTION MANUAL

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Analog Technologies VC99. Multimeter FEATURES

MS2030 CAT III 600 V A V AUTO RS232

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Model UT20B: OPERATING MANUAL Table of Contents (1)

Table of Contents GDM-356. Page

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

312, 316, 318. Clamp Meter. Users Manual

1.General instructions Specifications Description...7

BENCH METER Model>9803. Wavecom Instruments

User Manual Digital Multimeter. model no.: MSR-U1000

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

User Manual. All rights reserved. Specifications are subject to change without notice.

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Model UT10A: OPERATING MANUAL Table of Contents (1)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model : OPERATING MANUAL

CONTENTS MS2033A. 1.Introduction Safety Information...01

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

ATD-5519 Auto-Ranging Digital Multimeter Owner s Manual Features:

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

UT207A/208A/209A Operating Manual. Table of Contents

The Meter Structure The Figure 2-1 shows the Meter structure.

Transcription:

MODEL: D03126 Digital Multimeter with Backlight 1

CONTENTS Page Number Description 3 Important Safety Information 3 What s Included? 4 Overview 4 Front Panel Description 5 General Specification 5 DC Voltage 5 DC Current 6 AC Voltage 6 Diode & Continuity 6 Resistance 6 Transistor hfe Test (0-1000) 6 Operation - DC Voltage Measurement 7 Operation - DC Current Measurement 7 Operation - AC Current Measurement 7 Operation - Resistance Measurement 7 Operation - Diode Test 7 Operation - Transistor Test 8 Operation - Audible Continuity Test 8 Battery & Fuse Replacement 8 Cleaning 2

200mA/250V IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference.! Important safety information. Read the instructions carefully. High voltage. Danger. Ground. Double Insulation (Class II safety equipment). Fuse must be replaced as per the specification herein. When using electrical appliances basic safety precautions should always be followed. Do not exceed the protection limit values specified for each range range of measurement. Never use the meter to measure voltages that might exceed 600V above earth ground in category II installations. When the value scale to be measured is unknown beforehand, set the range selector to the highest position. Before rotating the range selector to change the functions disconnect the test leads from the circuit under test. When measuring a TV set or switching power supply, watch out for pulses in the circuit that may damage the meter. Before working with and measuring voltages higher than 60V DC or 30V AC RMS, keep your fingers behind the probe barriers. Before attempting to insert transistors for testing, always be sure that the test leads have been disconnected from any measurement circuits. Components should not be connected to the hfe socket when making voltage measurements with test leads. Do not perform resistance measurements on live circuits. The instrument can only be used in conjunction with the test leads supplied. If necessary, they must be replaced with the same type and specification. WHAT S INCLUDED? One instruction manual One digital multimeter Set of test leads One 9V battery, NEDA 1604 6F22 006P type Holster (optional) This meter is a handheld 3½ digital multimeter used for measuring DC and AC voltage, DC current, resistsance, diode, transistor and continuity. 3

OVERVIEW 1 7 2 3 6 5 4 Front Panel Description 1 Display - 3½ digit, 7 segment, 15mm high LCD 2 3 4 Backlight - once pushed the backlight of the display will turn on. It will selfturnoff after about five seconds. To turn the backlight on again, just push the button. Rotary switch - used to select functions and desired ranges as well as turn the meter on or off. VΩmA jack - plug in the connector for red (positive) test lead for voltage, resistance and current (except 10A) measurements. 5 COM jack - plug in the connector for the black (negative) test leads. 6 10A jack - plug in the connector for the red test lead for 10A measurement. 7 Hold button - once pushed, the display will keep the last reading and H symbol will appear on the LCD until the button is pushed again. 4

GENERAL SPECIFICATION Accuracy is specified for a period of one year after calibration and at 18 to 28 C (64 F to 82 F) with relative humidity to 80%. Max. voltage between terminals and earth ground Fuse Protection Power Display Measuring Method Overrange Indication Polarity Indication 5 CAT II 600V F 200mA / 250V Operating Environment 0 C to 40 C Storage Temperature -10 C to 50 C 9V battery, NEDA 1604 or 6F22 LCD, 1999 counts, updates 2-3 seconds Dual-slope integration A/D converter Only figure 1 on the display - displayed for negative polarity Low battery indication appears on the display Size Weight DC VOLTAGE 138mm x 69mm x 31mm Approx 170g Range Resolution Accuracy 200mV 100µV ± 0.5% of rdg ± 2 digits 2V 1mV ± 0.5% of rdg ± 2 digits 20V 10mV ± 0.5% of rdg ± 2 digits 200V 100mV ± 0.5% of rdg ± 2 digits 600V 1V ± 0.8% of rdg ± 2 digits Overload protection: 250V rms. For 200mV range and 600V dc or rms, ac for other ranges. DC CURRENT Range Resolution Accuracy 200µA 0.1µA ± 1% of rdg ± 2 digits 2mA 1µA ± 1% of rdg ± 2 digits 20mA 10µA ± 1% of rdg ± 2 digits 200mA 100µA ± 1.5% of rdg ± 2 digits 10A 10mA ± 3% of rdg ± 2 digits Overload protection: F 200mA/250V fuse (10A range unfused).

AC VOLTAGE Range Resolution Accuracy 200V 100mV ± 1.2% of rdg ± 10 digits 600V 1V ± 1.2% of rdg ± 10 digits Overload protection: 600V DC or RMS. AC for all ranges. Frequency range: 40Hz to 400Hz. Response: average responding, calibrated in rms of a sine wave. DIODE & CONTINUITY Range Description If continuity exists (about less than 1.5kΩ), the built-in buzzer will sound. Shows the approximate forward voltage drop of the diode. Overload protection: 250V DC or RMS, AC. RESISTANCE Range Resolution Accuracy 200Ω 0.1Ω ± 0.8% of rdg ± 3 digits 2kΩ 1Ω ± 0.8% of rdg ± 2 digits 20kΩ 10Ω ± 0.8% of rdg ± 2 digits 200kΩ 100Ω ± 0.8% of rdg ± 2 digits 2MΩ 1kΩ ± 1.0% of rdg ± 2 digits Maximum open circuit voltage: 3.2V Overload protection: 250V DC or RMS, AC for all ranges. TRANSISTOR hfe TEST (0-1000) Range Test Range Test Current Test Voltage NPN & PNP 0-1000 lb = 10µA Vce = 3V OPERATION - DC VOLTAGE MEASUREMENT Connect the red test lead to the VΩmA jack and the black lead to the COM Set the rotary switch at the desired DCV position. If the voltage to be measured is not known beforehand, set the range switch at the highest range position and then reduce it until a satisfactory resolution is obtained. Connect the test leads across the source or load being measured. Read the voltage value on the LCD display along with the polarity of the red lead connection. 6

OPERATION - DC CURRENT MEASUREMENT Note: for measurements between 200mA and 10A, remove the red lead to the 10A Set the rotary switch at the desired DCA position. Open the circuit in which the current is to be measured and connect the test leads in series with the circuit. Read the current value on the LCD along with the polarity of th red lead connection. OPERATION - AC VOLTAGE MEASUREMENT Set the rotary switch at the desired ACV position. Connect test leads across the source or load being measured. Read the voltage on the LCD. OPERATION - RESISTANCE MEASUREMENT Note: the polarity of the red lead is positive. Set the rotary switch at the desired Ω range position. Connect the test leads across the resistor to be measured and read the LCD. If the resistance being measured is connected to a circuit, turn off the power and discharge all capacitors before applying test probes. OPERATION - DIODE TEST Note: the polarity of the red lead is positive. Set the rotary switch at the position. Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approximate forward voltage drop of the diode will be displayed. If the connection is reversed, only figure 1 will be shown. OPERATION - TRANSISTOR TEST Set the rotary switch at the hfe position. Determine whether the transistor under testing is NPN or PNP and locate the emitter, base and collector leads. Insert the leads into the proper holes of the hfe socket on the front panel. Read the approximate hfe value and the test condition of the base current 10µA and Vce 3V. 7

OPERATION - AUDIBLE CONTINUITY TEST Set the range switch to position. Connect the test leads to the two points of the circuit to be tested. If continuity exists, the built-in buzzer will sound. BATTERY & FUSE REPLACEMENT If the symbol appears on the display it indicates that the battery shouid be replaced. To replace a battery and fuse (200mA/250V) remove the two screws in the bottom of the case. Before opening the case, always disconnect the test leads from all energised circuits. Remove the old fuse or battery and replace it with a new one of the same specification. Be careful to observe the battery polarity. Never use the meter unless the back cover is in place and securely fastened. CLEANING Use a soft, clean, dry cloth to clean the meter. Do not use any chemicals, abrasives or solvents that may damage the meter. INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT. This symbol indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers. Contact your local authority for details of the battery and WEEE recycling schemes available in your area. 8 Made in China. PR2 9PP V 1.0