Annexe to: IECEx SIR U Issue 5 Redapt Engineering Co. Limited Electrical Component: Ranges of Adaptor, Reducers and Stopping Plugs

Similar documents
Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

INSTRUCTION MANUAL (ATEX / IECEx)

Setting Standards Connectors M 16

Digital inductive conductivity transmitter

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

ED701 General Industry Pressure Transmitter

NPS/001/010 Technical Specification for Fasteners and Fixings for Wood Pole Overhead Lines and General Construction Works

SW 16mm. SW 15mm. SW 19mm

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

The transducer component converts the measured signal and displays the actual value.

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

tubing & fittings section guide

Pressure transmitter for general industrial applications Model A-10

FITTINGS. Pneufit C composite and Pneufit M fittings Metric Ø 3 to 16 mm O/D tube

Product range Cable Glands

Pressure transmitter for general industrial applications Model A-10

Piper GI Conduits. Heavy Gauge Welded GI Conduit, threaded

Pressure transmitter For general industrial applications Model A-10

Description of equipment

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

SEALING METHODS AND HARDWARE FOR EQUIPMENT AND PROCESSES APRIL 11-12, 2018

NEW. Automation Technology 768 series

Conductivity Transmitter

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

ph or ORP Transmitter

Precision Junction Boxes

Technical Datasheet. Performance Series Pressure Difference Switch Models: 301, 303, 304, 381 & 384. Performance Series. Key Features.

Level Measurement Continuous level measurement Radar transmitters

Thread and End Connection

Rosemount 3101, 3102, and 3105

Connecting elements for connecting hard-pressed steel with aluminium/steel

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Precision Junction Boxes

670 SCREWED FIX-IT KITS. Page WOOD SCREWS DOWEL PINS DOWELS STUDDING. Page Pages GROUP GROUP 651 EXTRACTOR GROUP 635 GROUP 650

SOCKET & NIPPLE. Quality products for a quality environment BSP THREADED FITTINGS - PP. Code K12. Socket - equal Injection moulded.

CAT GB. Quick-release couplings and accessories for Air Conditioning & Refrigeration. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Kerkau Manufacturing. B16.5 Flange Book

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

High-quality pressure transmitter For general industrial applications Model S-10

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

INLINE flowmeter for continuous flow measurement

SIGNAL // POWER // INDUSTRIAL ETHERNET

For Frequencies up to 110 GHz. RPC-1.00 Connectors TEST & MEASUREMENT

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Flow Measurement SITRANS F M

METRIC FASTENERS 1520 METRIC FASTENERS

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Installation & Operating Manual. iwap202

MATERIAL AND EQUIPMENT STANDARD FOR METRIC TYPE FASTENERS (SCREWS, BOLTS, STUDS, NUTS AND WASHERS) ORIGINAL EDITION DEC. 1997

INLINE flowmeter for continuous flow measurement

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

Digital flowmeter for continuous flow measurement

Samsung Gear VR. PennEngineering. April 26, 2016 by XiaoMing Chen & Larry Zhang. 1

Digital flow ELEMENT transmitter for continuous flow measurement

Cable glands and accessories

Technical Data. General specifications. Rated operating distance s n 3 mm

INLINE flowmeter for continuous flow measurement

GWR2 Installation guide: Guided Wave Radar

For use in Flammable Gas and Dust Atmospheres

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

P3-19 Series Connectors For Entertainment Lighting

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Local control stations for Zone 1 and Zone 21. Features. Description

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

REPUTE tube fittings are manufactured to stringent quality control program and internal standards which

3. ISO information on technical standardisation changeover to ISO

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

J: Emergency lighting (optional) L: pole type X: ceiling type

ISO INFORMATION ON TECHNICAL STANDARDISATION CHANGEOVER TO ISO

Digital flowmeter for continuous flow measurement

Durapipe ABS Jointing Guide

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B

Rhino SD2/XD2 Mini Tote Conversion Kit

SELF-TAPPING SCREW FIXINGS

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

Resistance Thermometers Model Series TR7X0, Sheathed Design

Control CONNECTOR. (AI500 Rev H 14Nov17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA.

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Digital conductivity transmitter

Threading - Hand Taps - Button Dies - Die Nuts - Screw Extractors - Holders - Sets THREADING

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Transcription:

Product Descriptions and Codings Adaptors and Reducers The AD-U series adaptors and RD-U series reducers each comprise a metallic, hexagonal, hollow body with an external male thread and an internal female thread. The devices are used to convert an existing cable entry aperture thread to a different thread form and/or size. The adaptors and reducers may optionally be machined with a groove to fit an O ring seal. Earth Lead Adaptors and Reducers The AE-E Series range of earth lead adaptors and reducers each comprise a hexagon body with a male thread at one end and a female thread machined into the other. The devices are designed to provide a connection from a cable gland or termination to earth via a 300 mm long earth lead cable riveted and soldered to the body, additionally, it may be used to convert an existing cable entry aperture thread to a different thread form and/or size. Ex e IIC Gb 90 Adaptors and Reducers The AR-D series range of 90 o thread adaptors and reducers, each comprise a body with either male/female or female/female threads machined into the body at 90 to the male thread. The components are designed to provide cable entry options where space is limited or to avoid cable damage. Additionally, they may be used to convert an existing cable entry aperture thread to a different thread form and/or size. Thread forms are between M16 and M75 inclusive. Male to Male Adapters The AM-D series range of thread adaptors each comprise a hexagon body with a male thread form at each end. The devices are used to convert an existing cable entry aperture thread to a different thread form and/or size. Female to Female Adaptors and Reducers The AF-U series range of thread adaptors each comprise a hexagon body with a female thread form at each end. The devices are used to convert an existing cable entry aperture thread to a different thread form and/or size. Thread forms are between M20 and M75. Date: 28 May 2012 Page 1 of 5

Stopping A range of threaded plugs used to fill unused cable entries in the associated apparatus. The PD-U series are metallic, round bodied devices with a dome head and having a hexagonal key-way recess for tightening; they may optionally be machined with a groove to fit an O ring seal. Ex e I/IIC Mb Gb The PA-D and PB-D series are metallic, round bodied devices with a thread run out to shoulder having a hexagonal key-way recess for internal or external tightening Design Options Threadforms - All products may be machined with the following typical thread forms of the nearest equivalent recognised thread size. Thread combinations are such that minimum wall thickness are maintained: ISO Metric (to BS3463) PG to DIN40430 NPT (ANSI/ASME B1.20.1) NPS (ANSI/ASME B1.20.1) ISO Pipe Thread (BS21) BSPP/BSPT Imperial conduit ET BS31 BSP to BS21 In addition, any other thread form that also complies with the requirements of IEC 60079-1 tables 3 o 4 and clause C.2.2 (as applicable) are also permitted. Material - The following materials are used as appropriate: Brass BS 2874 (CZI 21) Mild steel to BS970 (EN1A) Stainless steel to BS970 (316) Surface coating - The products may be additionally surface coated with: Nickel Zinc Electroless nickel. Date: 28 May 2012 Page 2 of 5

Special Points for Noting - the user/installer shall comply with the following conditions: AD-U Adaptors, RD-U Reducers and PD-U Stopping iii. The stopping plugs shall not be used with any form of adaptors or reducers. iv. When installed in group I applications, the ADU M16 (M) to M20 (F) adaptors manufactured in brass shall only be installed where the risk of mechanical impact is low. v. At their point of mounting, these devices are suitable for use at the following temperatures dependant on the type of O ring: O -ring Material Limiting temperature None -50 C to +180 C* Nitrile -20 C to +80 C EPDM -30 C to +125 C Neoprene -20 C to +100 C Viton -5 C to +180 C* Silicone -30 C to +180 C* Fluorosilicone -50 C to +150 C * The maximum temperature is limited to 150 C for Group I applications. AE-E Earth Lead Adaptors and Reducers iii. These devices are suitable for use at -20 C to 40 C at their point of mounting. AR-D 90 o Thread Adaptors and Reducers, iii. At their point of mounting, these devices are suitable for use at -50 C to 180 C. AM-D Thread Adaptors i. Only one adaptor shall be used with any single cable entry on the associated equipment. iii. These adaptors shall not be used for the direct inter-connection of enclosures. iv. At their point of mounting, these devices are suitable for use at -50 C to +180 C. AF-U Thread Adaptors i. Only one adaptor shall be used with any single cable entry on the associated equipment. iii. At their point of mounting, these devices are suitable for use at -50 C to 180 C. Date: 28 May 2012 Page 3 of 5

PA-D and PB-D Stopping iv. The interfaces between these devices and the associated enclosure cannot be defined; therefore, it is v. These stopping plugs shall not be used with any form of adaptors or reducers. vi. At their point of mounting, these devices are suitable for use at -50 C to +180 C for Group II applications and -50 C to +150 C for Group I applications. Conditions of Manufacture - the manufacturer shall comply with the following conditions: i. In accordance with EN 60079-1:2007, the coating on joint surfaces of metallic devices that are electroplated shall be no more than 0.008 mm thick. ii. The female threads of adaptors are restricted to one size larger than the male thread size. Date: 28 May 2012 Page 4 of 5

PD-E-4 nylon stopping plugs: The PD-E-4 Series is a range of 'Ex e' Durathon BKV 30 NI 30% Glass Filled Nylon 6 threaded stopping plugs each comprising a threaded body with a hexagonal socket for tightening. The devices are used to close unused apertures in associated component. Design Options Threadforms Options: ISO Metric (to BS3463) PG to DIN40430 NPT (ANSI/ASME Bl.20.1) NPS (ANSI/ASME Bl.20.1) ISO Pipe Thread (BS21) BSPP/BSPT Imperial conduit ET BS31 BSP to BS21 Any threadform conforming to Table 3 of IEC 60079-1 Special Points for Noting i. The stopping plugs shall not be used with any form of adaptors or reducers. iii. At their point of mounting, these devices are suitable for use at either -20 C to +40 C or -5 C to +40 C when using Viton seals. iv. The clearance holes for metric male threaded products, suitable for clearance hole applications of Increased safety enclosures are to have a diameter of 0.3 to 0.5 mm larger than the major diameter of the male thread. v. PD-E-4 stopping plugs employing parallel threads without seals, shall have at least eight full threads of engagement, with a minimum tolerance according to ISO 965-1 and ISO 965-3. Date: 28 May 2012 Page 5 of 5