Agilent E8460A 256-Channel Reed Relay Multiplexer

Similar documents
Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent dc Electronic Loads Models N3300A-N3307A

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent 8761A/B Microwave Switches

6.5-Digit Multimeter, High- Accuracy, C-Size HP E1410A Technical Specifications

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent E8267C PSG Vector Signal Generator

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

6 Tips for Successful Logic Analyzer Probing

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 8902A Measuring Receiver Product Note

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent E8267C/E8257C/E8247C PSG

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent 87415A, 87400A Microwave Amplifiers

Advanced Test Equipment Rentals ATEC (2832)

Agilent PNA Series RF Network Analyzers

Agilent 4285A Precision LCR Meter

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 83711B and 83712B Synthesized CW Generators

Agilent 8902A Measuring Receiver

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Advanced Test Equipment Rentals ATEC (2832)

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Product Note E5100A-2

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent EPM Series Power Meters

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

8-Channel 196 ksa/s Digitizer plus DSP

VT1419A Multifunctional Plus Measurement and Control Module

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent 8920A RF Communications Test Set Product Overview

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

expanding the possibilities

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent Technologies 3000 Series Oscilloscopes

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

Base Station Installation and Maintenance

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent PNA Microwave Network Analyzers

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 83430A Lightwave Digital Source Product Overview

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

Improving TDR/TDT Measurements Using Normalization Application Note

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Jitter Analysis Techniques Using an Agilent Infiniium Oscilloscope

Agilent 84904/5/8M Programmable Step Attenuators for Microwave and RF Manufacturing Test Systems

EMC Precompliance Systems and Accessories Catalog

Agilent 4-Port PNA-L Network Analyzers

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Agilent N3300 Series DC Electronic Loads

Agilent Optimizing Your GSM Network Today and Tomorrow

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

2750 Integra Mainframes

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent 8560 E-Series Spectrum Analyzers

Agilent Equalization Techniques and OFDM Troubleshooting for Wireless LANs

National Instruments Switches

Agilent CSA Spectrum Analyzer

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Data Sheet. Setting Standards

Agilent 6800 Series AC Power Source/Analyzer

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Racal Instruments 4152A. 6.5 Digit Digital Multimeter. Product Information

Agilent PNA Microwave Network Analyzers

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

Wavelength Calibration for the 8614X Series Optical Spectrum Analyzers. Product Note


Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.

How to capture, save, and reproduce arbitrary load current waveforms

AC Power Source/Analyzers...

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Agilent PNA Microwave Network Analyzers

Transcription:

Agilent E8460A 256-Channel Reed Relay Multiplexer Data Sheet 1-slot, C-size, register based High-density, low-cost multiplexer Fast scanning rate Flexible reconfiguration Contact protection for reliable operation Three different easy-to-use terminal blocks available as options Description The Agilent Technologies E8460A High-Density Reed Relay Multiplexer is a C-size, 1-slot, register-based VXI module. This 256-channel multiplexer, using reed relay switches, offers a fast, reconfigurable, high point-count switching topology. It is designed for applications requiring fast scanning rates by the use of fast action reed relays. This single-slot multiplexer extends the choices of multiplexers available to the system engineer. The E8460A can be programmed into individual topologies; some common examples are shown in the table below. Many other combinations of these topologies are supported (in addition to those shown in the table). Two-wire, threewire, and four-wire measurements can be configured. Agilent E8460A with Opt. 014 Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable. Common Multiplexer Configurations One 256 x 1 Four 64 x 1 One 128 x 2 Two 32 x 4 One 64 x 3 Sixteen 16 x 1

Accessories A terminal block does not come with the module. Three different terminal blocks are available as options: one for crimp-and-insert connectors, one for ribbon cable connectors, and the other for fault-tolerant protection of DUT inputs, where each channel has a positive temperature coefficient resistor that behaves like a resettable fuse and will increase impedance when excessive current is flowing in a channel. One 2.5-in. analog bus cable (E1400-61605) is included to connect the analog busses of multiple slot-adjacent E8460A modules or a slot-adjacent E1411B multimeter module. The analog bus cable, easily installed at the faceplate of the component card, lets you connect the E8460A with the E1411B DMM. Product Specifications Input te: These limits apply only if no connection is made to power mains. dc Performance Typical thermal offset (per channel): Closed channel resistance: ac Performance Bandwidth, 50 Ω Source/Load Configuration ± 50 µv 256 x 1: 4.5 MHz 64 x 1: 12.0 MHz 16 x 1: 30.0 MHz Closed Channel Capacitance <3 Ω with output protection resistor shorted, protection resistor adds 100 Ω 100 Ω Protection Resistor Shorted Configuration To Chassis To Open Channel 256 x 1: 1400 pf 70 pf 64 x 1: 460 pf 70 pf 16 x 1: 140 pf 70 pf Open channel to either open channel or to chassis capacitance: 70 pf Maximum Input With Opt. 012 Terminal Card With Opt. 014 or Opt. 015 Terminal Card Analog Bus Maximum dc voltage: 200 V 60 V 60 V Max. ACrms voltage: 140 V 50 V* 30 V Max. ACpeak voltage: 200 V 70.7 V 42 V Max. current per channel: Switching: 300 ma 100 ma n/a Carry: 500 ma 100 ma n/a Maximum power per channel: 5 VA Maximum power (resistive load): Per channel: 5 VA Per common output: 5 VA Per module: 60 VA *Rating reduced to 30 Vac-rms, 42 Vac-peak for exposed conductors. Hi-to-Low Capacitance (2-Wire Mode) Configuration Capacitance 256 x 1: 400 pf 64 x 1: 230 pf 16 x 1: 80 pf Crosstalk Configuration 10 khz 100 khz 1 MHz 10 MHz 256 x 1 (channel to chassis): 84 db 64 db 44 db 30 db 64 x 1: 84 db 64 db 44 db 27 db 16 x 1: 83 db 64 db 44 db 24 db 2

General Characteristics Relays: Open/close time: Minimum relay life: load: Rated load: Power up/down state: General Specifications Reed relays 0.5 ms max. 500 M operations 10 M operations (Max. rated resistive load) All open VXI Characteristics VXI device type: Register based Data transfer bus: A16, slave only Size: C Slots: 1 Connectors: P1/P2 Shared memory: ne VXI buses: ne Instrument Drivers - See the Agilent Technologies Website (http://www.agilent.com/find/inst_drivers) for driver availability and downloading. Command module firmware: Downloadable Command module firmware rev: A.08 I-SCPI Win 3.1: I-SCPI Series 700: C-SCPI LynxOS: C-SCPI Series 700: Panel Drivers: VXIplug&play Win Framework: VXIplug&play Win 95/NT Framework: Yes VXIplug&play HP-UX Framework: Module Current I PM (A) +5 V: 1.7 0.4 +12 V: 0 0 12 V: 0 0 +24 V: 0 0 24 V: 0 0 5.2 V: 0 0 2 V: 0 0 I DM (A) Cooling/Slot Watts/slot: 8.5 P mm H 2 O: 0.05 Air Flow liter/s: 0.7 Ordering Information Description Product. 256-Channel Reed Relay Multiplexer E8460A* Crimp and Insert Connector Terminal Block E8460A 012** Fault Tolerant Terminal Block E8460A 014*** Ribbon Cable Connector Terminal Block E8460A 015*** Service Manual E8460A 0B3 tes: * Standard unit does not include terminal block. One of the terminal block options must be ordered. ** Crimp-and-Insert Contacts are not included. See the Interconnect and Wiring section for information on ordering Crimp-and-Insert Contacts. *** Ribbon cables and mating connectors are not included. See ordering details below: Recommended 3M Mating Socket and Cable Part Description Socket (without strain relief) Socket * (with strain relief) Qty Required per Terminal Card 8 sockets either with or without strain relief 8 sockets either with or 3M Part Number 3414-6600 3414-6606 without strain relief Metal strain relief *(low profile) 8 * 3448-2034 Flat cable (34 conductor) Length as needed 3365/34 * Required only for socket with strain relief. Manufacturer Ordering Information 3M Electronic Products Division 6801 River Place Blvd. Austin, TX 78726-9000 Phone 800-225-5373 3

4

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test & measurement needs. Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 1 800 829 4444 Canada: (tel) 1 877 894 4414 (fax) (905) 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 (e-mail) tm_asia@agilent.com Data Subject to Change Agilent Technologies, Inc. 2001 Printed in the U.S.A. May 1, 2004 5965-8829E