E3X-DRT21/SRT21/CIF11

Similar documents
Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

CSM_G7S-_-E_DS_E_7_1

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

MY-GS CSM_MY-GS_DS_E_2_1

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Alternate Operation Relay 61F-AN/-APN2

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

E6F-CWZ5C (1000P/R) 2M

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Fluoro plastic housing for highest chemical and detergent resistance

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Model Number Structure

Sensing method Sensing distance Model

Model Number Structure

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Switch Mode Power Supply

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Model Number Structure

E8EB-N0C2B E8EB-N0B2B

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Switch Mode Power Supply

Auto Focus Multi Code Reader

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Phase-sequence Phase-loss Relay

Model Number Structure

Model Number Structure

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Phase-sequence Phase-loss Relay

Vision Sensor FH Series. Vision System. Operation Manual for Sysmac Studio FH-1 FH-1 - FH-2 FH-2 - FH-3 FH-3 - FH-5 FH-5 - Z343-E1-09

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Features. 2-Dimensional Code Reader (Fixed Type) V530-R150E-3, EP-3

Model Number Structure

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

E6F-CWZ5C (1000P/R) 2M

NEW. Better Productivity by Standstill and Low-speed Monitoring

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

S8V-NF (Single-phase 250 V 3 A / 6 A Type)

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

Single-phase Voltage Relay

F210 Vision Sensor Flow Menus and Macro Capability

Relays with Forcibly Guided Contacts G7SA

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

MaxLite LED Self-Driven LiteBars

Single-phase Current Relay

Model Operation mode TL-W5MD1 2M *1 *2 TL-W5MD2 2M *2 NPN TL-W5MC1 2M PNP TL-W1R5MB1 2M --- PNP TL-W3MB1 2M *2 TL-W3MB2 2M *2

Pre-Filter. Brushless/ Sparkless Blower. HEPA Filter. Fluorescent Light

Single-phase Current Relay

LED Displacement Sensor

Preliminary Data Sheet!

Vision Sensor FH series Operation Manual Sysmac Studio Conveyor Panorama Display Tool

Multipoint Temperature Controller

Master Reference Unit

A 2 W A 2 W Model Number Structure A2W. Model Number Structure Slave button.

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Signal Isolation Module. Instruction Manual SIM

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Radio Remote Controls Manual K Series

Output configuration Resolution (pulses/rotation) Model. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ6C (resolution) 2M

SSR-150xxx-40VL-12P-xC-xxxCS

Comfort 10S Wall Hardwire Installation and Operations Manual

SSR VL-12P-xC-NCS

LBI Mobile Communications MDX DESK TOP STATION. Operator's Manual

Installation/Operation Instructions and Warranty Information for Models...

Instruction Manual Inductive Gauging Sensor

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

Robot. Safety Guide I590-E-01

P.O. BOX 1521 POLSON, MT SSR V-12C

For Momentary Operation

Questions? Call Toll-Free

Warranty Terms & Conditions

Radio Remote(s) (Installation Manual)

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Instruction Sheet D-CPU. Secure CPU Holder

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

LBI-38976A. Mobile Communications MDX/ORION DESK TOP STATION. Operator's Manual

Transcription:

for E3X-DA-N-series Fiber Amplifiers /SRT21/CIF11 CSM SRT21_CIF11_DS_E_3_1 Three New s for Fiber Amplifiers DeviceNet CompoBus/S RS-422 Features Fibers RS422 Mobile Console Connecting a hand-held Mobile Console enables easy setting and monitoring. Optical Terminal-block E39-TM1 Using a Terminal-block allows input from Basic Switches. Programmable Controller Reduced Wiring New connectors enable wiring and space reductions, as well as easier maintenance. Create the Required Number of Channels by Connecting Up To s (14 s for CompoBus/S). A New Amplifier That Monitors the ON/OFF Incident Level. E3X-DA6-P The peak data and bottom data are updated according to the ON/OFF timing of the Sensor. This feature enables monitoring of aging and remote setting of thresholds, even in applications with a high ON/OFF frequency. (One is updated when the Sensor turns ON, and the other when the Sensor turns OFF, depending on whether the Sensor is light-on or dark-on.) Incident level data Threshold value Bottom data Peak data Wiring-reduction Connector E3X-CN02 Basic Switch

Ordering Information DeviceNet CompoBus/S RS-422 Terminal-block All communications methods E39-TM1 /SRT21/CIF11 Fiber Amplifier with Incident Level Monitoring Function* All communications methods Wiring-reduction Connector* E3X-DA6-P --- E3X-CN02 *Order Fiber Amplifiers and Wiring-reduction Connectors as sets. Ratings and Specifications Item DeviceNet CompoBus/S RS-422 Connectable Fiber Amplifiers *1 *2 E3X-DA6, E3X-DA8, E3X-DAB6, E3X-DAB8, E3X-DAG6, E3X-DAG8 E3X-DA6TW *3, E3X-DA8TW *3, E3X-DA6-P, E39-TM1 Number of connectable Fiber Amplifiers max. 14 max. max. Power supply voltage 11 to 25 VDC 14 to 26.4 VDC 11.4 to 26.4 VDC (12 VDC 5% to 24 VDC +10%) Internal current consumption *4 70 ma max. 30 ma max. 40 ma max. Ambient temperature Operating: 20 to 55 C, Storage: 30 to 70 C (with no icing or condensation) Ambient humidity 35% to 85% (with no condensation) Weight (packed state) Approx. 150 g Approx. 200 g *1. Connection is not supported for Pre-wired Amplifiers (e.g., E3X-DA11-N) and water-resistant Amplifiers (e.g., E3X-DA11V). *2. Connection is supported for products manufactured on or after the date shown below (indicated with the lot number). Connection is also supported for models with MADE IN JAPAN on the cover underlined. Lot No.1 8 6 0 1 Manufactured on 18 June 2001. Last two digits of the year of manufacture. Month of manufacture. October, November, and December are represented with X, Y, and Z respectively. Day of manufacture. *3. Manufacturing of the E3X-DA@TW Series was discontinued at the end of March 2012. *4. Does not include the current supplied to the Fiber Amplifier. Terminal-block Item E39-TM1 Power supply voltage*1 12 to 24 VDC ±10%, ripple (p-p) 10% max. Sensor power supply 11 to 23 VDC (power supply voltage 1 V) Current consumption 40 ma max. + Sensor current consumption (total: 100 ma max.) Response speed 1.2 ms max. Number of inputs 1 point Input signals NPN/PNP no-voltage input (contact and non-contact), switchable Input operating configuration N.O./ N.C., switchable Indicators Input signal display (orange) Operating: Groups of 1 to 3 s: 25 to 55 C (with no icing or condensation) Ambient temperature*2 Groups of 4 to 8 s: 25 to 45 C (with no icing or condensation) Groups of 9 to s: 25 to 40 C (with no icing or condensation) Storage: 30 to 70 C *1. The power supply for the E39- TM1 is provided from the (order separately). Use an E3X-CN02 (order separately) Connector. *2. When 4 or more s are grouped together, the current consumption per must not exceed 75 ma. When using together with the E3X-DA-N Fiber Amplifiers, connect the E39-TM1 s at the end of the group. In this case, the upper limit for the ambient temperature for the E3X- DA-N Amplifiers is the rated upper limit 5 C.

/SRT21/CIF11 Dimensions (: mm) Unless otherwise specified, the tolerance class IT is used for dimensions in this data sheet. (43) 30 34.6 (106) (75) (43) (65) 34.6 30 30 34.6 (106) (75) (46) (65)

/SRT21/CIF11 Terminal-block E39-TM1 3 71 10 3 64.6 40.65 In the interest of product improvement, specifications are subject to change without notice.

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See OMRON website or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.4 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2015 All Right Reserved.