- Wiring Brochure Universal Reset Module 423e

Similar documents
- Wiring Brochure Universal Reset Module 423

Relay (R1) 003. Balancing Valve. Slab Pump (P1) Max. 4 pipe diameters apart. Injection Pump (P2) 150 No 24V only. Power. Off.

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

BAS Integration Manual

USER'S MANUAL DMR-6700

P/N B ProBlue and DuraBlue Thermostat Service Kit - P/N

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

DM-45 Digital Multimeter

R PROFLAME Instruction Book Collection

Explosion Proof Page/Talk Paging Amplifier

Installation Instructions

ProfiScale MULTI Multimeter

OSMAC RDR Low-voltage Retrofit Kit

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

User's Guide. AC Circuit Load Tester. Model CT70

Autoranging Multimeter Extech EX503

Tesla K20 GPGPU Card Installation Guide

Installation Instructions

400Amp True RMS AC Clamp Meter + NCV

C-Bus 8 Channel Low Voltage Relay

312, 316, 318. Clamp Meter. Users Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

2011 / Circuit Tracer

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

MOUNT KIT PERSONAL PLOW

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

ELECTRONIC THERMOSTAT: T920

Log Periodic Antenna

F2A3X Frequency to Analog Converter Module

(Wireless Solution)

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

UPLIFT Height Adjustable Standing Desk 3-Leg (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE

Digital Room Sensor Technical Guide

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Calibration Comparison System

CONTENTS MS2033A. 1.Introduction Safety Information...01

400Amp True RMS AC/DC Clamp Meter Model EX613

Table of Contents. Introduction...3 Specifications...6 Installation Instructions...6

Rosemount 753R Remote Web Based Monitoring Indicator

2015 RIGOL TECHNOLOGIES, INC.

High Frequency SineWave Guardian TM Filter

USER'S MANUAL DMR-4350

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

ZHONGSHAN KOHLER SHOWER CO., LTD. NO13-1, XINGYE ROAD, ZHONGSHAN TORCH DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE:

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

TC 204 Heating Controller

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Installation Instructions

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Pen Multimeter. Model

E-BUS Digital Room Sensor Technical Guide

USB-TC Instructions. Description

Signal converter for electromagnetic flowmeters

Series Assembly Instructions

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

ITP14. Universal process indicator. User guide

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Pow-R-Feed Systems Service Manual

Radio Control Installation and Operating Instructions System 4

200Amp AC Clamp Meter + NCV Model MA250

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

Remote Control Outlets Operating Instructions

HAWK5000 Operators Manual

MP Series Radar Transmitter Installation & Operation Manual

30XR-A Professional Digital Multimeter Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Wireless 900 MHz Receiver

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Control module 2 circuits AD290. Installation and Service Manual

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User s Guide. Model MA A AC Mini Clamp-on Meter

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Wireless Room Thermostat Installation and Operation Y6630D1007

MS2030 CAT III 600 V A V AUTO RS232

Installation Instructions

MODEL 421 Over/Under Motor Load Monitor

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

OPERATING INSTRUCTION

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Transcription:

- Wiring Brochure Universal Reset Module 4e W 4e 0/08 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications Rough In Wiring Rough-in wiring instructions 4 Wiring Brochure Wiring and installation of specific control 5 Data Brochure Control settings and sequence of operation 6 Job Record Record settings & wiring details for future reference Overview The following wiring brochure describes how to wire the kanmor Universal Reset Module 4e. The 4e is to be installed in an enclosure together with a kanmor Power Manager. The 4e controls two boilers (on-off or modulating),, and setpoint. The wiring of tekmarnet 4 (tn4) components is simple and cost effective. Stage / Stage / Boil Enbl Setp Enbl 50 5 5 5 + - + - Mod (dc) Mod (dc) 54 55 56 57 C tn4 58 59 60 6 C tn4 6 6 C tn4 64 65 Com Boil Com Out 66 67 68 69 70 H705A Boil Sens Sup / Ret Off / Off / kanmor Stager s On-Off / Mod Off / Rotation Limited power available, see Powered wiring brochure Outputs 4 V (ac) 8 VA VA Test 7 7 7 74 4 V (ac) C Vlv C R Menu Item Universal Reset Module 4e INSTALLATION CATEGORY II 75 76 77 78 79 80 Setpoint Made in Canada Demand Demand Supply/signal wires 90 C min. N tektra 006-0 For product instructions, see brochure Demands: 0-60 V (ac) Relay Rating: 0 V (ac) 5 A Caution! Disconnect All Power before Opening 8 8 N 0 A max kanmor wiring Enclosure (not included) kanmor Power Manager 45e of 008 W4e - 0/08

Table of Contents Wiring Symbols & Definitions... Module Installation... Electrical Drawings...4-7 Wiring the Control...8-0 Troubleshooting Instructions... 0- Technical Data... Wiring Symbols Demand, signals control to operate. Requires a power and neutral connection. Use 4 to 60 V (ac), usually switched externally. Example: Demand Dry contact switch. Operates a device. Example: Powered switch. 4-5 V (ac) power, switched output to valve, pump, etc. tekmarnet 4 Earth ground Do not apply power to these terminals. Serious control damage will result. Definitions The following defined terms and symbols are used throughout this manual to bring attention to the presence of hazards of various risk levels, or to important information concerning the life of the product. Caution: Refer to accompanying documents Caution: Refer to accompanying documents INSTALLATION CATEGORY II Local level appliances Caution Improper installation and operation of this control could result in damage to the equipment and possibly even personal injury or death. It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards. This electronic control is not intended for uses as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit. Do not attempt to service the control. Refer to qualified personnel for servicing. Apart from any field replaceable fuse(s) there are no user serviceable parts. Attempting to do so voids warranty and could result in damage to the equipment and possibly even personal injury or death. 008 W 4e - 0/08 of

Module Installation Install the Universal Reset Module 4e in the left side of a tekmarnet 4 (tn4) wiring enclosure. The enclosure comes with a Power Manager pre-installed in the right side. Review the figure below to understand the installation of the 4e. To Install the 4e. Remove the front cover of the wiring enclosure by removing the two screws.. Remove the left side blank by removing the centre screw holding the blank and the Power Manager in place. Make sure the Power Manager stays in place.. Discard the blank. 4. The 4e has connector pins protruding from the underside of the board. The Power Manager has wiring harnesses with plugs that connect to these pins. Remove the required wiring harnesses from their retaining clips in the enclosure. 5. Carefully connect the Power Manager s plugs onto the pins on the underside of the 4e. There is one smaller gauge connector with three pins and one larger gauge connector with pins. These connectors can be installed only one way. Take care to ensure a good connection and avoid bending the pins. 6. Lower the 4e into the enclosure at an angle. Insert the two tabs on the left side of the 4e in to the corresponding slots in the left side of the wiring enclosure. 7. Lower the 4e toward the center of the enclosure until the two halves fit together. Make sure that the connector wires are placed underneath without pinching the wire. 8. Replace the center screw to hold the two controls in place. 9. Strip all wiring to a length of /8 in. or 0 mm for all terminals. Electrical Drawings The electrical drawing examples on the following pages show the 4e in common applications Choose the drawing that most accurately depicts the components in your system and use that drawing as a guide to aid in wiring your system. These are only concept drawings, not engineered drawings. They are not intended to describe a complete system nor any particular system. It is up to the system designer to determine the necessary components for and configuration of the particular system being designed including additional equipment isolation relays (for loads greater than the controls specified output ratings) and any safety devices which in the judgement of the designer are appropriate in order to properly size, configure and design that system and to ensure compliance with building and safety code requirements. of 008 W 4e - 0/08

Electrical Application 4e E Description: with and, Setpoint, Two On / Off s. On / Off 07e 07e Outdoor 070e On / Off Stage / Boil Enbl 50 5 Stage / Setp Enbl 5 5 + - + - Mod (dc) Mod (dc) 54 55 56 57 C tn4 58 59 60 6 C tn4 6 6 C tn4 64 65 Com Boil Com Out 66 67 68 69 70 4 V (ac) R & C tn4 = H705A Menu Universal Reset Module 4e See D 4e Boil Sens Sup / Ret Off / Off / kanmor Stager s On-Off / Mod Off / Rotation Limited power available, see Powered wiring brochure Outputs 4 V (ac) 8 VA VA Test 7 7 7 74 4 V (ac) C Vlv C R Item INSTALLATION CATEGORY II 75 76 77 78 79 80 Setpoint Made in Canada Demand Demand Supply/signal wires 90 C min. N tektra 006-0 For product instructions, see brochure Demands: 0-60 V (ac) Relay Rating: 0 V (ac) 5 A Caution! Disconnect All Power before Opening 8 8 N 0 A max Connections from Power Manager 0 V (ac) L & N Setpoint Call Refer to Job Record for Maximum Allowable Loads To ground 008 W 4e - 0/08 4 of

Electrical Application 4e E Description: with Aquastat and Valve, Setpoint, Single On / Off. On / Off 07e Outdoor 070e Stage / Boil Enbl 50 5 Stage / Setp Enbl 5 5 + - + - Mod (dc) Mod (dc) 54 55 56 57 C tn4 58 59 60 6 C tn4 6 6 C tn4 64 65 Com Boil Com Out 66 67 68 69 70 4 V (ac) R & C tn4 = H705A Menu Universal Reset Module 4e See D 4e Boil Sens Sup / Ret Off / Off kanmor Stager s On-Off / Mod Off / Rotation Limited power available, see Powered wiring brochure Outputs 4 V (ac) 8 VA VA Test 7 7 7 74 4 V (ac) C Vlv C R Item INSTALLATION CATEGORY II 75 76 77 78 79 80 Setpoint Made in Canada Demand Demand Supply/signal wires 90 C min. N tektra 006-0 For product instructions, see brochure Demands: 0-60 V (ac) Relay Rating: 0 V (ac) 5 A Caution! Disconnect All Power before Opening 8 8 N 0 A max Connections from Power Manager 0 V (ac) L & N Valve Call Setpoint Call Refer to Job Record for Maximum Allowable Loads To ground 5 of 008 W 4e - 0/08

Electrical Application 4e E Description: with Aquastat and, Setpoint, Multi-stage Control. 0-0 V(dc) to kanmor Stager 07e Outdoor 070e Stage / Boil Enbl 50 5 Stage / Setp Enbl 5 5 + - + - Mod (dc) Mod (dc) 54 55 56 57 C tn4 58 59 60 6 C tn4 6 6 C tn4 64 65 Com Boil Com Out 66 67 68 69 70 4 V (ac) R & C tn4 = H705A Menu Universal Reset Module 4e See D 4e Boil Sens Sup / Ret Off / On / kanmor Stager s On-Off / Mod Off / Rotation Limited power available, see Powered wiring brochure Outputs 4 V (ac) 8 VA VA Test 7 7 7 74 4 V (ac) C Vlv C R Item INSTALLATION CATEGORY II 75 76 77 78 79 80 Setpoint Made in Canada Demand Demand Supply/signal wires 90 C min. N tektra 006-0 For product instructions, see brochure Demands: 0-60 V (ac) Relay Rating: 0 V (ac) 5 A Caution! Disconnect All Power before Opening 8 8 N 0 A max Connections from Power Manager 0 V (ac) L & N Call Setpoint Call Refer to Job Record for Maximum Allowable Loads To ground 008 W 4e - 0/08 6 of

Electrical Application 4e E4 Description: with and, Setpoint, Two Modulating s. 0-0 V (dc) 07e 07e Outdoor 070e 0-0 V (dc) Stage / Boil Enbl 50 5 Stage / Setp Enbl 5 5 + - + - Mod (dc) Mod (dc) 54 55 56 57 C tn4 58 59 60 6 C tn4 6 6 C tn4 64 65 Com Boil Com Out 66 67 68 69 70 4 V (ac) R & C tn4 = H705A Menu Universal Reset Module 4e See D 4e Boil Sens Sup / Ret Off / Off / kanmor Stager s On-Off / Mod Off / Rotation Limited power available, see Powered wiring brochure Outputs 4 V (ac) 8 VA VA Test 7 7 7 74 4 V (ac) C Vlv C R Item INSTALLATION CATEGORY II 75 76 77 78 79 80 Setpoint Made in Canada Demand Demand Supply/signal wires 90 C min. N tektra 006-0 For product instructions, see brochure Demands: 0-60 V (ac) Relay Rating: 0 V (ac) 5 A Caution! Disconnect All Power before Opening 8 8 N 0 A max Connections from Power Manager 0 V (ac) L & N Setpoint Call Refer to Job Record for Maximum Allowable Loads To ground 7 of 008 W 4e - 0/08

Wiring the Control Terminals 50-78 The following section explains how to wire individual devices to the Universal Reset Module 4e. For step by step wiring refer to the terminal number on the right of the page. Before wiring ensure all power is turned off and take all necessary precautions. Install the supplied wiring compartment barriers by sliding them into the grooves provided as to isolate the low and high voltage wiring. Strip all wiring to a length of /8 in. or 0 mm for all terminals. Refer to the current and voltage ratings at the back of this brochure before connecting devices to this control. Wiring the Terminals 50-5, 5-5 Terminals 50-5 and 5-5 are dry contacts. No power is available from these switches. When the switch at 50-5 or 5-5 is closed the boiler is to turn on. The boiler gets no power from these terminals and the boiler must be wired to power as per the manufacturers directions. These terminals are typically connected to the boiler s control circuit (commonly labeled as T-T). Connect these terminals directly to the boiler T-T connections. T-T contacts on boiler T-T contacts on boiler Stage / Boil Enbl 50 5 Stage / Setp Enbl 5 5 Wiring the Modulating Output Terminals 54-57 The control provides a 0-0 V (dc) modulating output to two modulating boilers or to a kanmor boiler staging control that accepts an External Input Signal in place of an outdoor sensor. (Example: 64e) Polarity is important. Connect the + wire from the boiler or staging control to terminal 54 and the wire from the boiler or staging control to terminal 55. Connect the + wire from the boiler to terminal 56 and the wire from the boiler to terminal 57. Note: Some modulating boilers may also require an on / off signal in addition to the modulating signal. See terminals 50-5 and 5-5. Modulating + - + - Modulating or kanmor Stager + - Mod (dc) 54 55 + - Mod (dc) 56 57 Wiring tekmarnet 4 (tn4) Between Devices Terminals 58-65 Terminals 58 through 65 provide four tn4 connections for tn4 devices on either the bus, tn4 bus, tn4 bus, or tn4 bus. Connect terminals 58 (C) and 59 (tn4) to the corresponding terminals on other tn4 devices on the. Polarity is important. Connect terminals 60 (C) and 6 (tn4) to the corresponding terminals on other tn4 devices on the. Polarity is important. Connect terminals 6 (C) and 6 (tn4) to the corresponding terminals on other tn4 devices on the. Polarity is important. Connect terminals 64 (C) and 65 (tn4) to the corresponding terminals on other tn4 devices on the. Polarity is important. C tn4 typical tn4 connection on additional control C tn4 58 59 60 6 C tn4 6 6 C4 tn4 64 65 008 W 4e - 0/08 8 of

and (kanmor 07e) Terminals 66-69 Connect the two wires from the 07e to the and Com (66-67) terminals. The is used by the control to measure the water temperature. Connect the two wires from the 07e to the Boil and Com (68-69) terminals. The is used by the control to measure the boiler supply temperature. mounted on boiler pipe mounted in tank Com Boil Com 66 67 68 69 Outdoor (kanmor 070e) Terminals 69-70 Connect the two wires from the Outdoor 070e to the Com and Out (69-70) terminals. The outdoor sensor is used by the control to measure the outdoor air temperature. Note: If an Outdoor 070e is connected to a tekmarnet 4 thermostat in the system, it is not required to be connected to the control. mounted on exterior wall Com Out 69 70 Wiring a Valve Terminals 7-7 The control operates a 4 volt zone valve. Power is provided through an internal transformer to a maximum of 8 VA. Connect the wiring from the zone valve terminals 7 and 7 where terminal 7 is 4 volt C (neutral) and terminal 7 is 4 V R (hot) for opening the valve. 7 7 C Vlv Valve Wiring the Demands (, Setpoint) Terminals 7-78 To generate a Demand a voltage between 0 and 60 V (ac) must be applied across the Demand terminals (75-76). To generate a Setpoint Demand, a voltage between 0 and 60 V (ac) must be applied across the Setpoint Demand terminals (77-78). 4 V (ac) is provided on terminals 7 and 74 to power the Demand and the Setpoint Demand. Each demand uses approximately 0. VA. 7 74 4 V (ac) C R 75 76 Demand 77 78 Setpoint Demand Switch (from Setpoint Control or aquastat) The example shows the wiring to generate a Setpoint Demand. 9 of 008 W 4e - 0/08

Wiring the and Terminals 79-80, 8-8 The control operates a, and a. If a is used, the pump is wired directly to terminals 8 and 8. If a is used, the pump is wired directly to terminals 79 and 80. The pumps ground wires are connected to the ground screw provided in the wiring chamber. Note: For pumps larger than the control s rated capacity, an external isolation relay must be used. L & N 8 8 N Troubleshooting the Wiring General The following tests are to be performed using standard testing practices and procedures and should only be carried out by properly trained and experienced persons. A good quality electrical test meter, capable of reading from at least 0-00 V (ac), 0-0 V (dc), 0-,000,000 Ohms, and testing for continuity is essential to properly test the wiring and sensors. Test Meter Control Terminals For an explanation on the use of the Test Button, the Test sequence or any error messages, refer to the Data Brochure. Testing the Control Terminals 50-8 Test the Stage and Stage Contacts Terminals 50-5. Shut off power to the control and the boiler circuit.. Remove the front cover from the control. Disconnect the wires from the Stage and Stage contacts (terminals 50-5, 5-5).. Apply power to the control and press the Test Button. 4. Use an electrical test meter and check for continuity between terminals 50-5 and 5-5. When each stage symbol is displayed in the LCD, there should be continuity. When the stage symbol is not displayed in the LCD, there should be no continuity. 5. Reconnect the wires to the Stage and Stage contacts (50-5 and 5-5), install the front cover on the control and apply power to the boiler circuit. Testing the Modulation Output (0-0 V dc) Terminals 54-57. Ensure that the control is set to operate the modulating output.. Remove the front cover from the control.. Press the Test Button. 4. When the % output graph and the burner symbol are displayed in the LCD, use an electrical test meter to measure the (dc) voltage between the Mod (dc) + and the Mod (dc) - terminals (54-55, 56-57). The reading should vary between 0 V (dc) and 0 V (dc). 5. If power is not present: Check the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. 008 W 4e - 0/08 0 of

Testing tn4 Network Terminals 58-65 To test each tn4 Network, check the wires for continuity.. Disconnect the two wires (tn4 and C) at one end and connect them together.. Go to the other end of the wires and disconnect them.. Using an electrical test meter, check for continuity. Testing kanmor s Terminals 66-70 To test the sensors, the actual temperature at each sensor location must be measured. Use a good quality digital thermometer with a surface temperature probe for ease of use and accuracy. Where a digital thermometer is not available, strap a spare sensor alongside the one to be tested and compare the readings. Disconnect each sensor from the control. Test the sensors resistance according to the instructions in the sensor Data Brochure D 070e. Testing Zone Valve Terminals 7, 7. Ensure that the control is set to operate the zone valve output.. Remove the front cover from the control.. Press the Test Button. 4. When is displayed in the LCD, use an electrical test meter to measure the (ac) voltage between the C and Vlv terminals (7-7). The reading should be 4 V (ac) + / 0%. 5. If power is not present: Check the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. 6. When is not displayed in the LCD, use an electrical test meter to measure the (ac) voltage between the C and Vlv terminals (7-7). The reading should be 0 V (ac). Testing Auxiliary 4 V Power Supply Terminals 7-74. Remove the front cover from the control.. Use an electrical test meter to measure (ac) voltage between the Power R and Power C terminals 74 and 7 The reading should be 4 V (ac) + / 0%.. If power is not present: Check the power supply to the Power Manager and the field replaceable fuse for the transformer on the Power Manager. If the fuse is blown, determine the cause of the failure before replacing the fuse. Also check the Plug in connections on the underside of the control. Testing the or Setpoint Demand Terminals 75-78. Remove the front cover from the control.. Use an electrical test meter to measure (ac) voltage between the Demand terminals (75-76) or the Setpoint Demand terminals (77-78). When the demand device is on a voltage between 0 and 60 V (ac) should be measured between terminals and the LCD should display DEM and or SETP. When the demand device is off, less than 5 V (ac) should be measured between the terminals. of 008 W 4e - 0/08

Testing and Terminals 79-8. Remove the front cover from the control.. Press the Test Button.. When the symbol is displayed in the LCD, use an electrical test meter to measure the (ac) voltage between the terminals (8-8). 4. When the symbol is displayed in the LCD, use an electrical test meter to measure the (ac) voltage between the terminals (79-80). The reading should be 0 V (ac) + / 0%. Note: The proper mode must be selected before testing the pump output. If power is not present: Check the power supply to the Power Manager. Also check the Plug in connections on the underside of the control. Technical Data Universal Reset Module 4e; Four tekmarnet 4,, & Setpoint Control Microprocessor PID control; This is not a safety (limit) control Packaged weight.8 lb. (80 g) Dimensions -5/8 H x 5-/8 W x 9/6 D (9 x 7 x 4 mm) Approvals CE Approved Ambient conditions Indoor use only, to F (0 to 50 C) RH 80% to 88 F ( C), down to 50% from 04 to F (40 to 50 C) Altitude <000 m (656 ft), Installation Category II, Pollution Category Power Supply Provided by interconnected Power Manager Relay 0 V (ac) 5 A /4 hp, pilot duty 40 VA Relay 0 V (ac) 5 A /4 hp, pilot duty 40 VA Combined Load 0 A Maximum (for and ) Valve Output 4 V (ac) 8 VA Maximum Modulation Output 0-0 V Minimum 500 Relay 0 V (ac) 5 A /4 hp, pilot duty 40 VA Demands 0-60 V (ac) / 0. VA @ 4 V s NTC thermistor, 0k @ 77 F (5 C ± 0. C) ß=89 Included Outdoor 070e and Universal 07e kanmor Control Systems Ltd. 500 Silver Star Road Vernon, B.C. CANADA VB K4 50-545-69 Fax. 50-549-449 Web Site: www.kanmor.com 008 by kanmor Control Systems Ltd. Used with permission. kanmor trademark is used under license of All specifications are subject to change without notice. Printed in Canada. W 4e - 0/08.