Sine Wave Power Inverter GD150/GD300 Series User s Manual

Similar documents
TS-700/1000 INVERTER Instruction Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

SK Series Pure Sine Wave Inverter User s Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

SK Series Pure Sine Wave Inverter. User s Manual

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

Pure sine wave inverter USER S MANUAL

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

AC MASTER Switch mode sine wave inverter

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

IP Series DUAL POWER AMPLIFIERS

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

CLASS D MONO AMPLIFIER GM-D8601 GM-D9601. Owner s Manual

PWM-120 series. 120W PWM output LED power supply IP67. File Name:PWM-120-SPEC

DRIV-ZT-24V-90W LED 0-10V Dimming Driver, Wet Location

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

PWM-120-ADM series. 120W PWM output LED power supply IP67. File Name:PWM-120-ADM SPEC

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

SR-1600 User s Manual. Telecom / Datacom PURE SINE WAVE INVERTER

300W Railway Single Output DC-DC Converter

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

Power supply CP-D 24/4.2 Primary switch mode power supply

Tel: Fax:

Model S-520 Coin Counter / Sorter Operating Manual

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

PWM-120 series. 120W PWM output LED power supply IP67. File Name:PWM-120-SPEC

C-Bus 8 Channel Low Voltage Relay

R PROFLAME Instruction Book Collection

800W Single Output Power Supply

SYNRAD PS DC Power Supply (Meanwell RSP )

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

PWM-90 SERIES 90 Watt LED Power Supply Measures: 6.73 x 2.48 x 1.47

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

Power supply CP-T 24/20.0 Primary switch mode power supply

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

CLASS D FOUR-CHANNEL AMPLIFIER GM-D1004. Owner s Manual

RSD-200 SERIES 200 Watt Chassis Mount DC-DC Converter Measures: 7.44 x 3.39 x 1.54

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

BRIDGEABLE FOUR-CHANNEL POWER AMPLIFIER GM-A6604 GM-A4604. Owner s Manual

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

- 1 - GTI Grid Series. GTI Series Inverters For Grid User Manual

Power supply CP-E 24/2.5

Model: &

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 24/20.0

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Instruction Manual. Digital Panel Meter Model 3153B

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Power supply CP-T 48/5.0 Primary switch mode power supply

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION & USER'S GUIDE

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

GTI Series Inverters User Manual

Power supply CP-T 24/10.0 Primary switch mode power supply

Sendai Office , Ichiban-cho, Aoba-ku, Sendai, Miyagi pref TEL FAX

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Power supply CP-T 24/40.0 Primary switch mode power supply

Power Supplies 3. SDN-C Compact DIN Rail Series

H L G -150H s er i es

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

AMM-1022 Digital Multimeter USER`S MANUAL

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

HLG-600H IP65 IP67. series. 600W Single Output Switching Power Supply. Features. Applications

60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W

80W Single Output Switching Power Supply

English KS-DR3005D POWER AMPLIFIER: INSTRUCTION MANUAL

Power supply CP-D 12/2.1

E E E E E E E E E E E E IP65 IP67

60W Single Output Switching Power Supply

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

200W Railway Single Output DC-DC Converter 33.6 ~ 62.4VDC 28.8 ~ 67.2VDC

Power supply CP-E 24/0.75

AC 3. Active Antenna Combiner. Instruction manual

SK200,SK350 Series Pure Sine Wave Inverter User s Manual

200W 200.2W 199.5W 200.2W RIPPLE CURRENT OUTPUT RIPPLE & NOISE 2Vp-p 1.5Vp-p 1Vp-p 1Vp-p

IP65 IP mVp-p. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable 5 ~ 10A 3 ~ 6A 1.0% 2.5 ~ 5A 1.

R4850G1 Rectifier User Manual V1.3

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.

MASS SINE 12/800, 24/800 & 48/ V sine wave inverter

Power supply CP-D 24/1.3

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

Electrical Safety Tester

IP67 TRC ELECTRONICS, INC

PWM-40 series. 40W PWM output LED power supply IP67. File Name:PWM-40-SPEC

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V 4.65 ~ 9.3A 1.0% 3.9 ~ 7.8A 1.0%

Transcription:

Sine Wave Power Inverter GD150/GD300 Series User s Manual Ver.1.04E

Table of Contents 1. Safety Instructions... 3 2. General Information... 4 3. Inverter Features... 5 3-1 Specification...5 3-2 De-rating Curve...7 3-3 Dimension...8 3-4 Control Panel...8 4. Installation and Wiring Connections... 9 4-1 Installation Guide...9 4-2 Wiring Connections...9 4-3 Setting Confirmation... 11 4-4 How to Start Up... 11 5. Functions... 12 5-1 Change Settings... 12 5-2 The Indicators of Setting During Operation... 13 5-3 Operation Mode... 13 5-4 Sleep Mode... 13 5-5 The Protective Function... 13 5-6 Remote Connector... 15 5-7 Optional Terminal... 16 6. LED Indicators... 17 6-1 The LED Indicator in Normal Status... 17 6-2 The LED Indicators when Protective Function Activates... 18 7. Troubleshooting Guide... 19 Sine Wave Power Inverter GD150/GD300 User s Manual 2017-2018 DENRYO CO., LTD. All Rights Reserved. No parts of this document may be reproduced in any form without the prior written approval of DENRYO CO., LTD. 2

1. Safety Instructions This document contains the important safety and operating information for GD Inverter. To get most out of the Pure Sine Wave Inverter, carefully read, follow this guide, and save these instructions. Pay attention to the Safety Instructions and the CAUTION and WARNING statements found throughout the manual and on the product. WARNING CAUTION MEMO This sign indicates the following contents includes the important information. The wrong order of handling may lead to the risk of death or seriously injured. This sign indicates the following contents includes the important information. The wrong order of handling may cause damage to the products and the surrounding stuff. This sign indicates the following contents includes the important information of the manuals of functions which contains the safety instructions or the proper operation of the product. Precautions During Installation To avoid the risk of electric shock and fire, ensure adherence to proper electrical wiring regulations. Do not disassemble the GD Inverter. Do not expose the GD Inverter to rain, snow, dust or to the places with high humidity. Do not install the GD Inverter in the environments with high temperature, near a fire, or under sun exposure directly. During the operation of GD Inverter, the temperature of the products may become higher. Be careful while moving or removing the products. To avoid covering or obstructing the ventilation openings, do not to place any objects closer than 15 cm near the Inverter. To avoid overheating, do not place any stuff on the product. To connect with more than one battery, do use the same products of batteries from the same manufacturer. Connecting different products of batteries simultaneously is dangerous. Batteries generate explosive gases during normal battery operation. Never smoke or allow a spark or flame in vicinity of battery. This equipment contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing batteries or flammable materials. CAUTION Since the battery deteriorates over time, a maintenance on a yearly basis is recommended. Replace the deteriorated battery to prevent the hazard of fire. Do Not Disassemble Keep Dry Danger No Open Flame Do Not Stack High Temperature 3 Keep Air Ventilation

2. General Information GDseries Inverter is a pure sine wave inverter that converts DC voltage to AC since wave voltage. The output waveform is as same as the sine wave of commercial power supply, of which the total harmonic distortion is less than 3%. High efficiency circuit and switching control achieved 89% (GD150)/90% (GD300) efficiency at rated load. Without a built-in fan, the GD Inverter cools down by natural convection and has reduced the size of the products as well as kept quiet during operation. Moreover, the GD Inverter is equipped with abundant protective functions. Even the input polarity is reversed whereas the internal circuit does not be damaged. With the capability of operating under the wide input voltage range, temperature range and to turn on or off remotely, the GD Inverter could be used in various environments and applications. Features Protecting the input reverse polarity by its internal circuit Fan-less quiet operation (natural convection) The wide range of operating temperature(-20~60 ) Switching output voltage/frequency easily by button Pure sine wave output (total harmonic distortion less than 3%) Light weight and thin design High efficiency 89% for GD150/90% for GD300 efficiency at rated load) Built-in remote-control function Abundant protective circuit: Input voltage warning, shut down/input reverse polarity/ Output voltage/output short circuit/overload/overtemperature Buzzer ON/OFF, LED brightness switchable With low power mode and sleep mode setting Wide input voltage range Input system voltage of 12V/24V/48V 3 lineup Input terminal cover for dust prevention Optional communication function (T. B. D.) Block Diagram DC Input DC/DC DC/AC Filter AC Output Safety and EMC Certified Safety standards :EN60950-1:2006/A2:2013 Immunity standards :EN55024:2010 Emission standards :EN55032:2012, FCC class A Part15 FCC Requirements This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 4

3. Inverter Features 3-1 Specification MODEL GD150NA-112 GD150NA-124 GD150NA-148 Battery Voltage 12V 24V 48V Voltage Range* 1 10.5~17Vdc 21~34Vdc 42~68Vdc Current Range 10~16A 5~8A 2.5~4A No-load Current* 2 (Low power mode) 0.35A 0.20A 0.10A Input No-load Current (Normal mode) 0.57A 0.32A 0.18A Standby Mode Consumption 6.6mA 6.7mA 4.3mA Sleep Mode Consumption 1.4mA 3.4mA 2.5mA Efficiency at Rated Load 89% 89% 90% Rated Power 150VA Peak Power (3min.) 180VA (Refer to P.7) Surge Power (3sec.) 210VA AC Voltage (switchable) 100 default, 110/115/120Vac Output Frequency (switchable) 50±0.1Hz default, 50/60Hz Waveform Sine Wave, <3%THD Voltage Tolerance ±3.0% LED indicators Operating status, Battery voltage level, Output power level, Protection function, Operation setting Function Remote-control Output remote ON/OFF control terminal Option terminal six-position four-conductor (6P4C) modular jack Input UVP* 3, OVP* 4, input reverse polarity Protection Output OLP* 5, SCP* 6, output voltage error Others OTP* 7, detect by internal temperature sensors Operating Temperature -20~+40 at rated load, +60 at 70% load (Refer to P.7) Operating Humidity 20~90%RH non-condensing Environment Storage Temperature/ Humidity -30~+70, 10~95%RH Vibration 10~500Hz, 3G 10min./ 1cycle, 60mins. XYZ axes Safety Standards Certified EN60950-1:2006/A2:2013 Battery I/P-AC O/P: 3.0kVac Withstand Voltage AC O/P Ground: 1.5kVac Battery I/P Ground:1.5kVac Safety & EMC Battery I/P AC O/P: >1000MΩ/500Vdc/25 /70% RH Isolation Resistance ACO/P Ground: >1000MΩ/500Vdc/25 /70% RH Battery I/P Ground: >1000MΩ/500Vdc/25 /70% RH EMC Immunity EN55024:2010 EMC Emission EN55032:2012, FCC class A Accessories Cable with plug* 8 - - Others Dimension 234.0 146.5 44.0mm (L W H) Weight 0.9kg All parameters NOT specially mentioned are measured at 112:12Vdc, 124:24Vdc, 148:48Vdc input, 150VA rated load, power factor=1.0, 25 C of ambient temperature and under the default setting. * 1 Tolerance of voltage: 112±0.5V, 124:±1V and 148:±2V. * 2 Average. * 3 UVP: Under Voltage Protection. * 4 OVP: Over Voltage Protection. * 5 OLP: Over Load Protection. * 6 SCP: Short Circuit Protection. * 7 OTP: Over Temperature Protection. * 8 Length of cable: 1500±30mm 5

MODEL GD300NA-112 GD300NA-124 GD300NA-148 Battery Voltage 12V 24V 48V Voltage Range* 1 10.5~17Vdc 21~34Vdc 42~68Vdc Current Range 20~32A 10~16A 5~8A No-load Current* 2 (Low power mode) - 0.27A 0.12A Input No-load Current (Normal mode) 0.69A 0.37A 0.17A Standby Mode Consumption 7.9mA 7.3mA 4.6mA Sleep Mode Consumption - 3.6mA 2.7mA Efficiency at Rated Load 90% 90% 90% Rated Power 300VA Peak Power (3min.) 360VA (Refer to P.7) Surge Power (3sec.) 420VA AC Voltage (switchable) 100 default, 110/115/120Vac Output Frequency (switchable) 50±0.1Hz default, 50/60Hz Waveform Sine Wave, <3%THD Voltage Tolerance ±3.0% LED indicators Operating status, Battery voltage level, Output power level, Protection function, Operation setting Function Remote-control Output remote ON/OFF control terminal Option terminal six-position four-conductor (6P4C) modular jack Input UVP* 3, OVP* 4, input reverse polarity Protection Output OLP* 5, SCP* 6, output voltage error Others OTP* 7, detect by internal temperature sensors Operating Temperature -20~+40 at rated load, +60 at 70% load (Refer to P.7) Operating Humidity 20~90%RH non-condensing Environment Storage Temperature/ Humidity -30~+70, 10~95%RH Vibration 10~500Hz, 3G 10min./ 1cycle, 60mins. XYZ axes Safety Standards Certified EN60950-1:2006/A2:2013 Battery I/P-AC O/P: 3.0kVac Withstand Voltage AC O/P Ground: 1.5kVac Battery I/P Ground:1.5kVac Safety & EMC Battery I/P AC O/P: >1000MΩ/500Vdc/25 /70% RH Isolation Resistance ACO/P Ground: >1000MΩ/500Vdc/25 /70% RH Battery I/P Ground: >1000MΩ/500Vdc/25 /70% RH EMC Immunity EN55024:2010 EMC Emission EN55032:2012, FCC class A Others Dimension 234.0 146.5 44.0mm (L W H) Weight 1.0kg All parameters NOT specially mentioned are measured at 112:12Vdc, 124:24Vdc, 148:48Vdc input, 300VA rated load, power factor=1.0, 25 C of ambient temperature and under the default setting. * 1 Tolerance of voltage: 112±0.5V, 124:±1V and 148:±2V. * 2 Average. * 3 UVP: Under Voltage Protection. * 4 OVP: Over Voltage Protection. * 5 OLP: Over Load Protection. * 6 SCP: Short Circuit Protection. * 7 OTP: Over Temperature Protection. 6

3-2 De-rating Curve GD150NA-112/124/148 GD300NA-112 GD300NA-124/148 According to the system and environment that products are used in, the Inverter is still under the protection of OLP or OTP even in the range of de-rating curve. Since this feature of the Inverter, please design the system with more allowance. 7

3-3 Dimension 3-4 Control Panel 1 AC Outlet 2 AC Output Terminal 3 Setting Button 4 Power LED 5 Battery LED 6 Load LED 7 Power Button 8 Remote Connector 9 Optional Terminal 10 Grounding Terminal 11 Reversed Connection 13 Terminal Cover 14 Battery Input (+) Warning LED 12 Battery Input (-) 8

4. Installation and Wiring Connections 4-1 Installation Guide Recommended installation location: Locate the GD series Inverter on a flat place or rack with sufficient strength. Avoid mounting in a dusty environment or a location with high temperature. Avoid using the Inverter in a high temperature environment. For ventilation, do not mount any objects within 15 cm around the inverter. More than 15cm Do not place any objects on the top More than 15cm Figure 4.1 The example of installation Recommended installation Regulation: There are 8 holes, Φ3.4mm, and depth 6.5mm, in the bottom of the Inverter (Refer to P.8) which could be utilized when installing the Inverter. It is recommended to install the Inverter horizontally with the ground. CAUTION Burns Hazard. During operation, the temperature of GD series Inverter will get higher. Be careful not to touch it. 4-2 Wiring Connections To make Battery wiring connections: Remove the cover of the terminal on the rear side of GD series Inverter and wire it to the battery input terminal. When removing the cover, slide while pushing the terminal cover toward the bottom. Mount a fuse in the plus side wiring. Please refer to Table 4.1. to select the fuses based on the system. Please use suitable wiring cable for power supply terminal. The screw size of battery input terminal is M4; the width of the terminal is 9 mm. The cable size recommended to be used at rated load is 12AWG for GD150, 8AWG for GD300; the torque recommended for installation is 1.5 N m. Using too thin cable may lead to overheating or ignition of cable. The length of Battery wiring connection should be as short as possible that within 1.5 m is recommended. Before continuing Battery wiring connection, check the power LED in front of inverter is lighting orange. Check the voltage of Battery if not lighting. Further, if the polarity of Battery is reversed, the reverse connection warning LED near the grounding terminal in the rear of the Inverter lights red. Please correct the polarity and check if the reverse connection warning LED is off. Table 4.1 Fuse recommended Model Current Model Current GD150NA-112 Under 20A GD300NA-112 Under 40A GD150NA-124 Under 10A GD300NA-124 Under 20A GD150NA-148 Under 5A GD300NA-148 Under 10A 9

WARNING Explosion Hazard The short of Battery is very dangerous. Make the wire connection of input terminal of GD Inverter before connecting the Battery. To make the grounding wire connection: Connect from the grounding terminal in the rear of GD Inverter to the system is being used. The screw size of the grounding terminal is M5; the width is 14mm. Please use solderless terminals, like R5.5-5, and fasten it with a screw. The cable size of 10sq (5AWG) and torque 2.0 N m is recommended. To make load wire connection: Connect the load from the AC outlet in the front of the GD Inverter or the AC output terminal. Choose to use the cable with proper withstand voltage of AC output terminal when connecting the AC output terminal. The VVF1.6 cable is recommended to be used here. It is connected by inserting the cable, which is peeled off the cover, into the hole which is marked as AC OUTPUT on the front panel. The length to peel off is around 15-20 mm and make the part which the cover has been peeled off could not be seen from outside. Make sure that the wire connected to line (L) and neutral (N) is not short-circuited after connection. When removing the cable, insert a flathead screwdriver in the oval hole above the cable insertion hole, and pull the cable while pressing the flathead screwdriver to remove it. CAUTION WARNING Terminal damage. Pressing the flathead screwdriver obliquely and strongly, the terminal may be damaged. Shock Hazard Make sure the core wire does not expose to the outside. Moreover, when connecting the AC terminal, be sure to connect it without output voltage. DO NOT short the line and the neutral. Make sure the connection of the line and the neutral is correct in your system when using both the outlet and the terminal of the Inverter. Precautions about load: Inverter is able to operate at most of loads under AC environment. However, even continuously supplying 150VA (GD150)/300VA (GD300), there is a possibility that Inverter may not operate properly at some loads. (1) An extremely large current, around 6~10 times more than at rated load, is required for Inverter to startup at inductive load or the motor. The Inverter may not be able to startup normally in the case. Please check the amount of peak current at load before choose Inverter. (2) To ensure the complete startup of the Inverter, when connecting with a capacitive load or a rectifier such as switching power supply, do not activate the load while the Inverter startup. Alternatively, start up the Inverter with a smaller load and increase load afterward. If connecting with more than two loads, please activate one load at once after the Inverter started up. To make Remote Connecter wire connection: By the function of remote connecter in the rear of GD Inverter (Refer to P.15) it can turn the output ON/OFF 10

without pressing power button. The recommended size of cable for remote connecter is 0.08~0.5sq (20~28AWG). To make Optional Terminal wire connection: The optional terminals in the rear of GD Inverter uses a six-position four-conductor (6P4C) modular jack to adapt to various application. Check DENRYO Official Website for more details. Figure 4.2 System Wiring Diagram 4-3 Setting Confirmation The default setting is output voltage 100Vac, output frequency 50Hz, low power mode (Refer to P.13) buzzer ON, and normal mode of the LED brightness. Pressing the setting button on the front panel to change the settings (Refer to P.12) Settings remain even the Battery went out its power. 4-4 How to Start Up Keep pressing the power button on the front side of the Inverter for around 1 second. Make sure the Inverter is not under the protection mode by checking the LED indicators (Refer to P.18) and turn on the load. 11

5. Functions 5-1 Change Settings 1. Connect with battery and set the GD Inverter to the standby status the power LED is lighting in orange and other LEDs are off. Do not connect anything to AC outlet and AC output terminal. 2. Pressing the setting button in the standby status, the current setting will display around three seconds. To change the setting, press and hold the setting button. Hold down the button for about two seconds, and a buzzer sound* comes from the Inverter while only the power LED indicator lights. Release the setting button and proceed to the next step. *The Inverter does not sound once the buzzer is setting OFF. 3. Check the output frequency setting refer to Table 5.1. Press the setting button to select the color of power LED until it matches the color of output frequency and operation mode you choose. Hold the setting button. 4. Check the battery LED in the center of the Inverter is lighting. Refer to Table 5.1, press the setting button to select the color of battery LED until it matches the color of output voltage you choose. Hold the setting button. 5. Check only the load LED on the right side of the Inverter is lighting. Refer to Table 5.1, press the setting button to select the color of load LED until it matches the buzzer setting ON/OFF and the LED brightness you choose. Press and hold the power button for more than 2 seconds to complete the settings and back to the standby status. If pressing and holding the setting button before holding down the power button, the setting mode begins again from the output frequency. 6. Press the setting button. Check the Inverter is the same as the setting you chose. Figure 5.1 The LED and settings button LED Table 5.1 The LED color of settings Power LED* Battery LED Load LED LED Color Green 50Hz, Low power mode 100Vac Buzzer ON, bright LED Yellow 60Hz, Low power mode 110Vac Buzzer ON, dark LED Blue 50Hz, Normal mode 115Vac Buzzer OFF, bright LED Purple 60Hz, Normal mode 120Vac Buzzer ON, dark LED * The power LED is "Green: 50 Hz, Standard", "Yellow: 60 Hz, Standard" only for GD300NA-112,. 12

5-2 The Indicators of Setting During Operation It is possible to check the current settings during operation by pressing the setting button, refer to Table 5.1. Settings are not able to be changed during operation. 5-3 Operation Mode In low power mode (only GD300-112 not applicable), GD Inverter optimizes its operating condition depending on the input voltage and load to suppress the power consumption at low load. It is particularly effective when inverter operates for a long time at a small load of 0 to 100W. Changing mode setting will not change the output waveform. However, under the low power mode condition, if the load suddenly increased, such as in the moment of a load activating, the output waveform may be interrupted for a half cycle time about 10 milliseconds in the case of 50Hz output. Without regard to load, for not to interrupt the output waveform, please choose the normal mode. Regardless of the operation mode, output may stop momentarily when the output current exceeds the rated current. 5-4 Sleep Mode GD Inverter turns standby mode after connecting with batteries; the power LED lights orange and other LEDs light off. In the standby mode, hold the power button and setting button simultaneously for 3 seconds, the Inverter turns to sleep mode. In sleep mode, all LEDs light off, power consumption can be suppressed more than in the standby mode. The GD Inverter in sleep mode, is as same as in standby mode, can be activated by power button and a remote connector. However, settings cannot be confirmed or changed by pressing the setting button in sleep mode. Hold the power button and setting button again for 3 seconds to turn back to standby mode. Once the connection with battery removed, the sleep mode will be canceled. 5-5 The Protective Function To prevent error operation, GD Inverter is equipped with the following functions. A. Reversed battery polarity protection: The reverse warning LED near the grounding terminal in the rear of GD Inverter lights red when the battery polarity is reversed. Please unconnected the wire and connect with the correct polarity. B. Battery low voltage protection: When the battery voltage falls below the value of low voltage warning, the buzzer sounds three times consecutively around every 5 seconds. When the battery voltage falls below the shut off value of low voltage, the Inverter automatically shuts off the output, the buzzer sounds five times consecutively around every 5 seconds, and battery LED blinks red. GD Inverter restores automatically when battery voltage become higher than low voltage recovery value. The buzzer will not sound when the buzzer is setting OFF. 13

MEMO The low voltage protection might work under the conditions such as the load consumes too heavy output power at the time of the engine starting. It might cause the output stops since the battery voltage drops. C. Battery over voltage protection: If the battery voltage is higher than the overvoltage warning value, the buzzer sounds three times consecutively around every 5 seconds. When the battery voltage is higher than the shut off value of overvoltage, the inverter automatically shuts off the output, the buzzer sounds five times consecutively around every 5 seconds, and the battery LED lights red. When the battery voltage falls below the overvoltage recovery value, it automatically resumes output. The buzzer does not sound when the buzzer is setting OFF. CAUTION Damage Hazard Please use a battery matching the input voltage range with the Inverter. If using a 12V battery with a 24V model that the voltage of the battery is lower than the input voltage range, the Inverter will not operate. Conversely, if using a 48V battery with a 24V model that the voltage of the battery is higher than the input voltage range, the Inverter may be damaged. D. Over temperature protection: When the internal temperature of the Inverter becomes higher than the overtemperature warning value, the buzzer sounds three times consecutively around every 5 seconds. When the internal temperature rises further, the overtemperature protection works and automatically shuts off the output, the buzzer sounds five times consecutively around every 5 seconds, and the power LED lights red. When the internal temperature falls below the value, the Inverter automatically resumes output. E. Output voltage error protection: When the AC output voltage is too high or too low, the inverter shuts off the output, the buzzer sounds five times consecutively around every 5 seconds, and the load LED lights red. To cancel the protected status, please restart the Inverter. F. Output short circuit protection: When the output terminal of the Inverter is short-circuited or the load suddenly increases, the Inverter cuts off the output, the buzzer sounds five times continuously every 5 seconds, and the load LED lights red. To cancel the protected status, please restart the Inverter. G. Overload protection: When the output is within the range of 100%~120% rated power, continues for about 3 minutes or more, and the output continues for about 3 seconds more than 120% rated power, the overload protection is activated to cut off the output and the buzzer. The buzzer sounds five times consecutively every 5 seconds, and the load LED lights red. To cancel the overload protected status, please restart the Inverter. MEMO The protected status can be canceled by turning the output ON/OFF by remote connector. Please cancel the protected status after checking the cause of protected status has been removed. Refer to Table 5.2 for the input voltage setting value of protective function in each model activates and resumes. Also, refer to Table 6.4 for LED indicators during protective function activates. 14

Table 5.2 The input voltage setting value of protective function Low voltage Overvoltage Model Warning Shut off Resume Warning Shut off Resume 112 11.5Vdc 10.5Vdc 12.5Vdc 16.5Vdc 17.0Vdc 16.5Vdc 124 23.0Vdc 21.0Vdc 25.0Vdc 33.0Vdc 34.0Vdc 33.0Vdc 148 46.0Vdc 42.0Vdc 50.0Vdc 66.0Vdc 68.0Vdc 66.0Vdc When the warning and protective function activated, the buzzer could be set OFF by pressing the setting button. If the buzzer has been set OFF by the setting button, the buzzer will sound again once other warning or protective function activated again. Moreover, even the warning status is cancelled, the buzzer will sound again once the Inverter activated the warning status again. Example 1. The low voltage warning activated and the buzzer was beeping. The buzzer has been set OFF by setting button. The buzzer beeps again when the Inverter shuts off because of low voltage protection. Example 2. The overtemperature warning activated and the buzzer was beeping. The buzzer has been set OFF by setting button. After the temperature dropped and the warning was released, the buzzer beeps again once the temperature warning activates again. If you want to set OFF the buzzer anytime, please change the settings to stop the buzzer (Refer to P.12) 5-6 Remote Connector As the figure 5.4 method 1, inverter output turns ON by inputting the battery voltage to the ENABLE+ (EN+) terminal of the remote connector. The Inverter turns to standby mode or sleep mode when input removed. As the figure 5.4 method 2, inverter output turns ON by connecting the ENABLE- (EN-) terminal and the GND terminal. Disconnecting EN- terminal and GND terminal, the Inverter turns to the standby mode or sleep mode. The power LED lights blue when the Inverter output turned ON by the remote connector. The Inverter can be operated either by method 1 or method 2. When the Inverter turned on by EN+ terminal or EN- terminal input, pressing the power button will turn the Inverter to standby mode or sleep mode. Even pressing the power button in this mode, the output cannot be turned on until the EN + terminal or EN - terminal input has been once removed. Method 1 Method 2 Method 1 Method 2 EN+ Short: ON Open: OFF Battery EN- GND Short: ON Open: OFF Figure 5.4 The wiring of remote connector 15

5-7 Optional Terminal The GD Inverter can achieve various application by using the optional terminals on the rear of the Inverter. Check DENRYO Official Website for more details. 16

6. LED Indicators MEMO The blinking frequency of each LED indicator is once in two seconds, repeat lighting and off. 6-1 The LED Indicator in Normal Status Power LED: Power LED indicates the ON/OFF status of output or the overtemperature warning status. Refer to Table 6.1 for the indicators of LED colors and the status. Table 6.1 Power LED Indicators LED Power LED LED Colors Orange Standby Blinking orange Standby/ Sleep (Turned ON by remote connector*) Green Power ON Blue Power ON Remote is operating Blinking yellow Overtemperature warning *When the inverter turned ON by remote connector, and turned OFF by the power button, the Power LED blinks orange. In the case, the output cannot be turned on until the connection of remote connector has been once removed. Power LED blinks orange even in the sleep mode. Battery LED: Battery LED indicates the voltage value of battery during operation. Refer to Table 6.2 for the indicators of LED colors and voltage value of battery. The voltage value of 124 and 148 models is double and 4times more than the value listing below. Table 6.2 Battery LED Indicators LED Battery LED LED Colors Blinking yellow Input voltage 10.5-11.5Vdc Yellow Input voltage 11.5-12.0Vdc Green Input voltage 12.0-14.0Vdc Blue Input voltage 14.0-16.5Vdc Purple Input voltage 16.5-17.0Vdc Load LED: Load LED indicates the percentage of output power during operation. Refer to Table 6.3 for the indicators of LED colors and the percentage of output power. 17

Table 6.3 Load LED Indicators LED Load LED LED Colors Blue 0-40% output power Green 40-70% output power Yellow 70-100% output power Blinking yellow Over than100% output power 6-2 The LED Indicators when Protective Function Activates When the GD Inverter activates the protective function, LED indicates the status of the protective function and cut off outputting. Refer to Table 6.4 for the LED indicators and the status of protective functions. Table 6.4 The Indicators of protective functions Lighting LED Power LED Battery LED Load LED Indicators Blinking --- Input low Red voltage Red Overtemperature Input overvoltage AC output error Overload/Load terminal shortcircuited All LED Internal error* * Please consult with the dealer if an internal error occurs. 18

7. Troubleshooting Guide Fault Condition Possible Cause Solution No AC output voltage Short operation time of the Inverter Output voltage, frequency error Power LED does not light up even connecting with battery Remote connector does not work Unusual noises get in loads such as radio Input voltage error Battery LED lights red/ blinks red Overtemperature protection Power LED lights red Overload protection Load LED lights red Short-circuit protection Load LED lights red AC output terminal wiring problem Internal error All LEDs light red/blink red Battery problem Lack of battery capacity Wrong setting Reversed connection of battery polarity Reverse connection warning LED lights red The internal fuse cuts off In the sleep mode Wiring problem Switching noise If the fault condition cannot be solved, please consult with the dealer. * The effect differs depending on the environments or devices Check the value of DC input voltage and adjust the range of input voltage. Check the status of the ventilation is blocked or the air temperature is too high. Please reduce the load capacity or lower the outside air temperature. Check the status of the load capacity, including the instantaneous value, exceeds the rated value of load or not. Check the status of the load wiring connection is short-circuited or not. Check the status of the wiring to the AC output terminal is appropriate or broken. It is possible that internal parts of the Inverter may be damaged. Please consult with the dealer. Please change the battery. Please check the battery specifications and increase the battery capacity. Change the settings (Refer to P.12) Correct the connection to the correct polarity Parts of the internal Inverter may be damaged. Please consult with the dealer. Hold the power button for 3 seconds. If still not lighting up, disconnect the battery and re-connect after 5 seconds. Check if the status of wire connection of the remote connector is correct. Try the ways* below to reduce the noise: 1. Keep the inverter and load away 2. Ground the ground terminal 3. Install an appropriate line filter circuit 19

DENRYO CO., LTD. 28-5, Nishinippori 2Chome, Arakawa-ku, Tokyo 116-0013, Japan Phone : +81-3-3802-3671 FAX : +81-3-3802-2974 Email: info-en@denryo.com www.denryo.com/en DM-5111 20