Materials Needed. Tube Size O.D.

Similar documents
Soldering & De-soldering

Case Study On-Site Brazing Audit Improves Client s Joint Quality and Optimizes Brazing Process Overview of Process

(a) Work gloves may be cloth, leather palm, or all leather; (b) Welding gloves are gauntlet-type gloves with high

SUPPLIED BY DELTA FLUID PRODUCTS LTD DELTA ROAD ST. HELENS WA9 2ED UK TEL: FAX:

Shay Line Shafts & Universal Fabrication

IX. FLARED JOINTS IX. FLARED JOINTS

Make a Safe. Description. Lesson Objectives. Assumptions. Terminology

LocoGear. Technical Bulletin - 02 January 11, by LocoGear LIVE STEAM CASTINGS. Tech Bulletin - 02

INSTALLATION INSTRUCTIONS

Field Installed Connectors for TraceTek 7000-HUV Bulk Cable Installation Instructions

INSTALLATION INSTRUCTIONS

Char-Lynn Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor November, 1996

INTRODUCTION. Tube and fitting

Union coupling, copper x female thread. Cone joint

Airflex Product Line PDC Installation, Operation and Maintenance of PDC Assemblies

MINI-LATHE QUICK CHANGE TOOL POST

WEAR SAFETY GLASSES WHEN INSTALLING THIS KIT.

MODEL T26413, T26414, & T26415 ARBOR PRESS INSTRUCTIONS

Plumbing Part II - Hand Pump

WARNING. Failure to observe these instructions could lead to severe injury or death.

A Practical Update on Advanced Copper Alloys and On-Site Joining Methods for HVACR Systems. Educate Promote Defend Support Inspire

Heat, Color, Set & Fire

BRAZING PROCEDURE SPECIFICATION NO

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

Basic Assembly For Conventional Series 9000 Structural Panels

No November, Char-Lynn. Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor

Installation and Specification Manual December 2012

BRAZE INSTRUCTION VIDEO

2.00AJ / 16.00AJ Exploring Sea, Space, & Earth: Fundamentals of Engineering Design Spring 2009

Cross Peen Hammer. Introduction. Lesson Objectives. Assumptions

Flat Style Fender Flares Rear Pair. Jeep. Included in Hardware Kit:

Introduction to Soldering

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

Better Soldering (A COOPER Tools Reprint) Overview Solder and Flux Base Material

Soldering Basics. Purpose We hope this short manual will help explain the basics of Soldering. The emphasis will be on the care and use of equipment.

Heat, Color, Set & Fire

Data Sheet. Number: 003 Issue: BASIC SOLDERING TECHNIQUES.

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

unit 3: GENErAL ElectriCAL SySTEM DiAGNOSiS

Meat Hook. Tools: Materials: Directions: Name: 1/4 round cold rolled steel 20 long 1 wooden dowel 5 long Epoxy Wood Stain Sand Paper Emery Cloth

ASSIGNMENT 2. Textbook Assignment: 2-1. Levels are designed for which of the following purposes?

INSTALLATION STANDARD FOR WELDED COPPER AND COPPER ALLOY WATER TUBE IAPMO IS

METAL FABRICATION MECHANICAL


Assembly Instructions for the 1.5 Watt Amplifier Kit

Jeep. Flat Style Fender Flares Rear Pair. Included in Hardware Kit:

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

#85-2-5A: PAINT STRIPPING AND FINISH ANALYSIS AND CORRECTION - (Aug 7, 1985)

Make a Portable Hibachi

Q-Sox Installation Instructions

Additional Information

UNPACK & ASSEMBLY. Done! CAUTION! THE MILL WILL BE VERY HEAVY - GET ASSISTANCE Pepe Tools.

Woven Leather Chandelier Large Assembly and Installation Instructions

Hand Torch or Flame Brazing Principles

INSTALLATION OF WELLS SUPER QUICK CHUCK LEFT HAND ON BALDOR LATHE

UNPACK & ASSEMBLY. Done! CAUTION! THE MILL WILL BE VERY HEAVY - GET ASSISTANCE Pepe Tools.

Installation Instructions:

A Precision 2000 Mixed Media Project

Series Inline Oscillating Saw

INSTALLATION INSTRUCTIONS

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

OPERATING INSTRUCTIONS

Catalog October Speedi-Sleeve The quickest and most economical way to repair worn shafts

S-Series General Purpose Motors Parts and Repair Manual -012

Tools Required For Servicing: Needle Nose Pliers

SE5a Instrument Board part 2 - rev 1.1

MODEL T /2-TON ARBOR PRESS INSTRUCTIONS

14401 NE Keil Road, Aurora, Oregon, USA PHONE FAX

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Quick Fit Installation Guide Retractable Screen - Double Door

INSTALLATION INSTRUCTIONS

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

5/16 Hex Head Bolt, 16 pcs. Plastic Push Retainer, 6 pcs. Alcohol Wipe, 2 pcs. Side Refl ex Reflector, 2 pcs

Jeep. Flat Style Fender Flares Front Pair Front Part # Rev-9 02/23/2016 For complete fitment info visit :

SOLDERING & BRAZING SOLDERING & BRAZING

Blackhawk by Proto pliers are manufactured to meet and exceed the demands of the automotive and industrial professionals. Alloy steel construction

Building Rudy Kouhoupt s Walking-Beam Engine

Clarinet/Bass Clarinet Care

Stained Glass Mission-Style Frame A stained glass project

ELECTRICAL CONNECTIONS

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

Before you start Warnings Never use scourers, abrasives or chemical cleaner. IMPORTANT, RETAIN FOR FUTURE REFERENCE READ CAREFULLY See enclosed instru

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Shay Drive Shafts & Universal Fabrication

7-1

Heat Exchanger Coil: Build Instructions

QUASAR ELECTRONICS KIT No DRILL SPEED CONTROLLER

Fabricate a Coat Hook

IMPORTANT SAFETY INSTRUCTIONS:

AMETAL SHAPER is indispensable for certain METAL SHAPER FOR YOUR SHOP. By S. S. Miner

DODGE Grease Lubricated SPLIT-SPHER Roller Bearings and Pillow Blocks

Making a basic hook tool By Alan Lacer

INSTALLATION INSTRUCTIONS

Make a Pencil Holder. Description. Lesson Objectives. Assumptions. Terminology

Durapipe ABS Jointing Guide

Custom Pendant- Hardwire Assembly and Installation Instructions

Transcription:

Materials Needed Eaton FF9075 silver braze rings or 1/16- inch diameter 45% silver alloy braze wire Water soluble flux Brazing outfit capable of +1200ºF (propane or mapp gas) Small files - rattail and flat Spray paint (quick drying) Water (to cool joint) Needle nose pliers Tape measure Emery paper Hacksaw Pliers Pair of diagonals (or other tool to cut silver wire) Residue-free degreasing agent Wire brush Existing hose socket for reusables Eaton crimp nipple/socket for crimp Tube Size O.D. Part Number (Inches) FF9075-19 0.25 FF9075-06 0.38 FF9076-74 0.60 FF9075-08 0.63 FF9075-09 0.75 FF9075-86 1.00 FF9076-87 1.25 FF9075-88 1.50 2 EATON Lifesaver Fittings E-SROV-TS008-E1 May 2012

Lifesaver Fittings Brazing and assembling Lifesaver reusable fittings is a simple process Eaton Lifesaver hose fittings are designed to simplify the replacement of failed hose lines which have unusual, steel end configurations, compound tubes, or thread styles. Refer to your master catalog for available sizes and hose configurations. The process involves removing the old configuration, silver brazing it to an unused Lifesaver nipple and assembling the fitting onto the hose in the usual manner. A few Lifesaver fittings, some bulk hose, the appropriate hand tools and accessories plus basic silver brazing equipment are all that is necessary to make up hose assemblies anywhere. Be sure to follow all applicable safety procedures when brazing Lifesaver fittings. STEP 2 Cutting Using a hacksaw or tubing cutter, cut the tube at the juncture of the tube and the hose socket. It s important to cut the tube so there is at least 1/4 inch length of straight, un-bent tubing in order for it to properly enter into the counter bore of the Lifesaver nipple. STEP 1 Measuring Measure and record the length of the old assembly. For elbow assemblies, scribe a very light mark 5/16 inch or more from juncture of the tube and the existing hose socket. The distance from the scribe mark to the end of the other fitting should be recorded as the fabrication length. In the case of double elbows, make the scribe marks in line with one another so that you can duplicate the phase angle later. Record the distance between the two scribe marks as the fabrication length. STEP 3 Preparing the tube for brazing Avoid touching the tube, oily or greasy surfaces tend to repel the flux and silver material leaving voids and inclusions. Clean the tube thoroughly using a residuefree degreasing agent, or hot caustic soda. Using a flat file, remove the burrs on the outside of the tube and use a rattail file to remove the burrs on the inside. Polish the tube end on the outside with an emery cloth to remove the plating down to the base metal. It is important to remove oil and grease first because abrasives tend to scrub the oil into the surface and/or impregnate it with a fine abrasive powder, resulting in further contamination. Remem EATON Lifesaver Fittings E-SROV-TS008-E1 May 2012 3

Lifesaver Fittings (cont...) ber, attempting to braze contaminated or improperly cleaned surfaces will generally result in an unsatisfactory joint. STEP 5 Fluxing Cover the counterbore, ring, outer hex and threads of the Lifesaver nipple and the outside of the tube with water soluble flux. STEP 4 Preparing the Lifesaver fitting for brazing Clean the nipple and tube end thoroughly. Place the tube into the counterbore (it should fit freely into it). Measure the diameter of the counterbore to determine the braze ring size needed. At this point, you have the option of selecting a readymade Eaton braze ring or making a ring for the application from bulk silver braze wire. To assemble, simply place the appropriate size Eaton FF9075 braze ring into the counterbore of the Lifesaver nipple. To make a braze ring, multiply the diameter of the counterbore by 3 to determine the length of silver wire needed. For example, if the counter-bore diameter measures 3/4 of an inch, a 2¼ inch length of wire would be needed (3/4 X 3 = 9/4 or 2¼ ) Now cut off a piece of sliver wire just short of 2¼ inches, so it is about 2 3 / 16 inches long. Using needle nose pliers, form the wire into a ring and, after wiping it off, place the ring into the counterbore of the Lifesaver nipple. STEP 6 Brazing Place the tube assembly into a vise. Place the nipple with the installed braze ring over the tube. Light the brazing torch and adjust the flame so that the base is blue with orange feather-like-flicks at the end. Try to heat both the nipple and the tube uniformly so they both reach the brazing temperature at the same time. Don t overheat the thin section. As the temperature increases, the flux will undergo several changes: At 212ºF or (100ºC) the water boils off. At 600ºF the flux becomes white puffyand starts to work (snow balling). At 800ºF it lays against the surface and has a milky appearance. At 1100ºF it is completely clear and active and has the appearance of water. At this point, a bright metal surface will appear underneath. The silver wire melts at 1125ºF (600ºC) and flows at 1145ºF (620ºC). 4 EATON Lifesaver Fittings E-SROV-TS008-E1 May 2012

Lifesaver Fittings (cont...) CAUTION! Steam may be directed through the fitting ends. To prevent burns, handle the fitting carefully. Hot water will facilitate flux removal. CAUTION! Never heat the parts to a bright red color. When the silver alloy melts, the flux will draw it throughout the joint and a small fillet of silver alloy will appear around the tube. When this happens the braze is completed. Remove the heat source and allow the fitting to cool for five to ten seconds. Using pliers, place the fitting into water until it completely cools. STEP 8 Hose assembly or Shoulder To determine the required amount of new hose, measure the distance from the scribe mark on the tube (refer to step 1) to the shoulder hex of the Lifesaver nipple. Add this measurement to the Lifesaver D dimension (cut off dimension) found in the Fittings section of the Eaton Master Catalog. For each Lifesaver fitting, subtract this sum from the fabrication length previously recorded. Cut the hose to this length and install the fitting. Align the scribe marks to establish the phase angle. Spray paint brazed joints to prevent rusting. STEP 7 Removing Flux It is necessary to remove residual flux from the area since it is corrosive and presents an unclean appearance and condition. Simply rub the surface using hot water and a wire brush. The water should be at least 120ºF or hotter to be truly effective inside and out. Shop for other automotive tools on our website. EATON Lifesaver Fittings E-SROV-TS008-E1 May 2012 5