Installation of Desert Aire FreshAire Evacuator Bench System

Similar documents
STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Dura-Lock Roof System

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

Installation Instructions

Installing your new Bevella Top. L Shaped Countertop with Joints No Finished Ends (Fits Between Four Walls)

Steel Solutions USA 602 E. Walnut Street Watseka, IL p: (888) f: (815)

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Installation Instructions for easy to install Texture Plus faux wall panels

INSTALLATION MANUAL STOREFRONT DOORS

Balustrade Systems / Installation Instructions

Sliding Glass Door Assembly and Installation Guide

Chapter 22 - Cabinets & Vanities

Installation Guidelines

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

HOW TO INSTALL ELITE PANELED WAINSCOTING Using X-Rails with Either Raised, Flat or Beaded Panels

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

CAUTION: Before opening the crate place it flat on its side (not up right as show in the photo) Hardware included for assembling your gazebo:

PRO CYCTM PRO CYC, INC. SYSTEM 1.5 FS

NX7 SERIES 5-1/2 HANDRAIL

Chapter 1. Beam and Sill Plates

Heavy Wall Applied Stop Tube Frame and Door Installation

12, 14 & 16 Wide Enclosure Assembly Guide

Duralam Wall Linings. Installation Guide. Duralam 6mm Compact Laminate Wall Panelling Installation Guide

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

Frameless Bypass Slider

FIXED PANEL SLIDER QCI5241

12 x 12 Flat Top Pergola

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

Curium 19H Installation Instructions & Parts List

Installation Instructions

Curium 19.4H Installation Instructions & Parts List

QWALL 5.2 (2 Back Panels)

12 x 12 Flat Top Pergola

Frameless Inline Door With Return QCI5263

YSD 400 Sliding Door System Installation Manual

THANK YOU FOR PURCHASING FROM HERITAGE PATIOS

FRAMED PANEL / DOOR / PANEL CONTINUOUS HINGE SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Frameless Inline Door QCI5254

3/8 FRAMELESS BYPASS SLIDING SHOWER ENCLOSURE

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

10 x 10 Arch Top Pergola

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

SLATTEX (Textured Slatwall) INSTALLATION GUIDE

Track Rack. * Track Racks are not lockable

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Frameless Inline Door QCI5248

ALL SEASON PATIO COVER

Jabiru Installation instructions

VINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS

RENU PANELING SYSTEM Installation Guide PLEASE READ GUIDE COMPLETELY BEFORE ASSEMBLY. Version 1.0 ALL STATED SIZES ARE NOMINAL DIMENSIONS.

Installation Instructions Palladium Square Edge Panels

Install Windsor Corners

10x10 Trellis Pergola

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

UNIT No FRAMELESS PIVOT SHOWER DOOR

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

VANITY INSTALLATION INSTRUCTIONS

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

PORCH-LOC INSTALLATION INSTRUCTIONS

FIXED MOUNTING SHUTTERS INSTALLATION

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

10 x 10 Flat Top Two Tone Pergola

IMPORTANT READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

A-935 RODA WALL MOUNT HINGES

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5 EZ

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5QS

Model 2400/4000 Illustrated Installation Instructions

60 DIRECT-TO-STUD SHOWER WALL SET

Installation Instructions. Oakmont Folding Doors

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

Frameless Bypass Slider

Frameless Inline Door QCI5250

ClearSpan Raised Bed Kits

PRO CYC PRO CYC, INC. SYSTEM SUPER 3EZ

Model 5400H / 7000H Illustrated Installation Instructions

YUKON PATIO COVER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 960 RODA GLASS TO GLASS HINGES ANGLED FRAMELESS PANEL / DOOR / PANEL CELESTA DRESDEN TRESOR

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

Balustrade System Installation - Cambridge & Huntington

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

ClearView Panels Mil 3 Finished Sides with Grommets 1 Hem Side Mil 3 Finished Sides with Grommets 1 Hem Side DESCRIPTION

3/16 OR 1/4 FRAMELESS SWING DOOR WITH SINGLE INLINE PANEL OR TWO INLINE PANELS

12 x 12 Flat Top Pergola

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Chapter 19. Interior Finish Work

FRAMED SLIDING DOOR FOR TUB OR SHOWER ENCLOSURE 6150A-7150A

10 x 10 Flat Top Pergola

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

Exterra Installation Guide

340D & 350D SERIES FRAMELESS BYPASS BATH ENCLOSURES

RoofScreen Mfg., Inc. DryCap Installation Manual Updated Introduction This manual Application System Overview...

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

FRAMED SLIDING DOOR FOR TUB OR SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

8 x 8 Flat Top Pergola

Transcription:

Installation of Desert Aire FreshAire Evacuator Bench System Unpack Evacuator and check for shipping damage. If there is damage, immediately notify shipper and contact Paddock Evacuator. Confirm that all parts are with shipment according to Packing List. If any parts are missing or you have any questions or concerns, please call 262-946-7400 or email service@desert-aire.com. Please read complete installation guide before beginning actual installation. The Evacuator System Installation will include: 1. The Evacuator Bench Installation 2. The Exhaust Duct Installation 3. The Desert Aire RecoverAire or locally sourced Exhaust Fan Installation 4. System Balance with Existing Mechanical System 5. Owner Training and Project Acceptance Upon Completion Contractor Suggested Materials for Evacuator Bench Installation Measuring Tape Blue Painter s Tape Hammer Drill Chalk Line Cordless/Impact Drill Duct Tape 1/4 Masonry Bit Shop-Vac #3 Phillips Bit Extension Cord(s) Caulk Gun Evacuator Bench Installation: 1. FreshAire Evacuator must be installed per the Specification Design Drawing. 2. Locate area for exterior exhaust penetration (wall/roof) as defined on drawing. 3. Place connection box and position for alignment with exhaust penetration. Ensure that this location works as designed. 4. Establish exhaust penetration location according to design solution. Keep in mind that there may be minor job site modifications required for final penetration location. Evacuator IO Manual 1

5. Position connection box base to align with exhaust penetration, making sure open ends of base are aiming toward area where benches will be located. a. Ensure that the connection box base is level and square to wall. b. Drill four (4) holes through base (two (2) per concaved foot area equally spaced) with hammer drill using ¼ masonry bit. c. Anchor to floor using four (4) plastic anchors and four (4) 1 stainless steel screws (provided). 6. Place connection box in base by setting one side in the lip and applying pressure to the opposite side while pushing the box down until secure in the bottom of the base. Ensure that male ends of the connection box are facing the correct direction. Do not anchor connection box in place at this time. 7. Place bench bases on floor aligning each end to end. Make sure alignment is straight and square with the wall or columns. Do not secure the bench base to deck at this point. 8. Dry fit all benches within bases to assure correct fit and complete system alignment. a. All Benches have a male (right end) and a female (left end) to them. This design allows for multiple bench systems to be connected together. b. Place the bench in the base by setting one side of the bench in the base and applying pressure to the opposite side while pushing the box down until secure in the bottom of the base. This step may require one person at either end of the bench. c. Bench may not fit tight against outside of base. This will be addressed when permanently installed. d. Make sure entire system aligns properly as designed. 9. Once properly aligned per the design drawing, remove the benches from the base and place them safely out of the way to avoid damage and interference with base installation. Leave the bench bases in place. 10. Anchor the bench bases. a. Ensure that the bench base is level and square to wall. b. Drill eight (8) holes through base (two (2) per concaved foot area equally spaced) with hammer drill using ¼ masonry bit. c. Anchor to floor using eight (8) plastic anchors and eight (8) 1 stainless steel screws (provided). d. Repeat above steps for more than one bench base as required in design. Evacuator IO Manual 2

11. At this point, the connection box base(s) and bench bases should be secured to the deck and level. 12. Cut the exhaust duct adapter hole in the connection box. Use a jig saw and fine tooth blade, such as 14tpi or higher. Fasten exhaust duct adapter to connection box. Make sure adaptor hole and exhaust penetration are properly aligned. 13. Clean all base and bench edges to ensure adhesion of caulk. 14. Secure connection box in base: a. Apply a bead of marine grade caulk/adhesive (provided) around the inside lip of the base. b. Place connection box in base, wiping off excess caulk leaving a clean smooth surface. 15. Secure Benches in base: a. Apply a bead of marine grade caulk/adhesive (provided) to the inside lip of both sides of the base, and male end of previous bench if required. b. Place bench in the base and slide end over previous bench end. Apply wedges if needed to spread bench flush against base wall. Wedges must be removed after caulk sets (30 minutes). This may cause a delay in installing additional benches. c. Wipe off excess caulk leaving a clean smooth surface. 16. Install provided End Caps a. Apply a bead of marine grade caulk/adhesive (provided) around the lip of the male end (either bench or end cap). b. Place end cap wiping off excess caulk leaving a clean smooth surface. 17. Install plastic molding pieces on front of bases and around connection box base, cutting to length as needed. 18. Caulk seam between bench and top of plastic molding. 19. Finish bench installation by applying caulk between bench joints as follows: a. Using blue painters tape, apply tape to both sides of joint. b. Apply caulk to joints with appropriate tip - attempt to keep caulk joints small and narrow to assure clean finish. c. Smooth caulk joint with finger. Applying a household cleaner (e.g. Windex) to wet fingertip will make joints cleaner and smoother. d. A clean, smooth caulk finish is essential to a good looking finished product. Evacuator IO Manual 3

EVAC-SGL-L EVAC-SGL-R Evacuator IO Manual 4

EVAC-DBL-L EVAC-DBL-R Evacuator IO Manual 5

EVAC-DBL-C EVAC-TRL-L Evacuator IO Manual 6

EVAC-TRL-R EVAC-TRL-QUAD Evacuator IO Manual 7

450 2017/03