Miniature oiltight controls PW

Similar documents
800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Major 5001 Wire Stripper

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Round Indicator Lights Mounting Hole Page

KRPA, KRP, KA, KR series

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Open Type Without Enclosure

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps

1.3. Pushbuttons and Indicating Lights.

Open Type Without Enclosure

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Switches & Pilot Devices

Powerpole Connectors - PP75: up to 120 Amps

SB 50 Connectors - up to 120 amps

Number Of Holes Chart For Standard Book Length Sheet Size

UNIQUELY DESIGNED RELAY FEATURES

PWC Series Electrical Connectors with Quick-disconnect, double-start Threads

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

TOGGLE SWITCHES IP67 A 9 SERIES 1B AGENCY APPROVALS SPECIFICATIONS

A W - A 2A R - 24D - 1

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Control Stations ø 22

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES

Document # Logos: Purch-11B Purchasing Use ONLY: How to Change a Vendor in Logos Original Author Karrie Revolinski Date 5/10/13 Updated Author Date

67TD Series - Miniature Time Delay Relays DPDT, 4PDT, 5 Amp

General data. 13/20 Siemens IC Overview Front plate mounting

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Complete units: Selector switches ø 22mm

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Complete units: Mushroom heads ø 22mm

ROCKER SWITCHES B 1 SERIES 3A SPECIFICATIONS AGENCY APPROVALS

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Complete units: Push-buttons ø 22mm

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Operator Heads: ø 22mm

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

General-Purpose Photoelectric Sensor

INSTRUCTION BOOK EASILY REMOVEABLE DIES FOR YOUR BINDING NEEDS OD 4012 SHOWN WITH THE OPTIONAL PALM SWITCH FOR THE OD 4012

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

Table of Contents. Kilovac Time Delay Relays

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Local control stations for Zone 1 and Zone 21. Features. Description

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

CATALOG OF REPLACEMENT PARTS

Details on the New G2RS

Light-strip indicator

General Purpose Relays Types K, R, N, and C

Power Connectors for Industrial and Commercial Applications

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

SERIES WW24 Industrial Wirewound Rotary Potentiometer 24mm Diameter / 5 Watts

General Specifications

CALRAD 25 series - potentiometers

Catalog Number 724 ESP-8MC / ESP-12MC / ESP-16MC / ESP-24MC ESP-28MC / ESP-32MC / ESP-36MC / ESP-40MC

CATALOG OF REPLACEMENT PARTS

RU Series Universal Relays

Solid-State Digital Counter H7AN

Operator Heads: ø 22mm

DUAL HEAD FLOOR GRINDER PARTS LIST MODEL CC200

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

Sorenson Lighted Controls

Model Number Structure

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Separate units: Blocks

GENERAL PURPOSE RELAYS

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

Position switches FM series

Solid-State Switching Devices

EAO Product Information. Series 84

Self-Powered Counters H7ET

General data. 13/4 Siemens IC

30AUTO Speed Lathe Manual

CALRAD MINIATURE MULTI-CLICK DUAL CONTROLS 40 STEP P.C. MOUNT 11

Level Lance Model 5100

ø30 ARN/ARNS Series Mono-lever Switches Switches

Variable Attenuators (Step & Continuous)

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

1208 P10-VHF-H-20. Frequency Range: MHz. Efficiency: 10% Temperature Range: 0 to 70 C Max VSWR: 5:1. Class: Supply Voltage: 28.

3TK28 Safety Relays. General data. 7/70 Siemens LV

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Quality Commitment # #

TWO PIECE / PLUGGABLE CONNECTORS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

APES HD-7700 Version Operator s Training Manual

model tsa-sa48 Sliding Crosscut Table installation guide

LED Followspot PRODUCT DATA. LED Followspot

Spring Return DuraDrive Proportional Actuator

PS-40A-1 AC Bench Power Supply

sealed mini usb connectors

SEALED, ILLUMINATED ROCKER SWITCHES

ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

Transcription:

Miniature oiltight controls PW IN THIS SECTION Introduction Making up a listing...52 Contact blocks Mechanical...5 Unlighted pushbuttons Mechanical operators...54 Lighted pushbuttons Mechanical operators..56 Separate parts..58 Indicators Two lamp indicators..59 Standard and push-to-test.60-6 60 selectors Mechanical operators..62 Selector-push Mechanical operators..64 Legend plates...66 Potentiometers..67 Accessories...67 Mounting dimensions.68-70 CONTACT BLOCKS Three types of contact blocks: Standard only General purpose electronic duty (silver Contacts) Low level electronic duty (gold Contacts) Contact blocks snap into the operator housing for quick, easy installation. Three types of terminals: Printed wiring board or wire wrap are on the same level for fast, timesaving wiring. Lamps for lighted devices can be changed from the front of the panel which saves time. No need to remove the entire control to change a lamp. Anodized aluminum mounting rings secure the operator to the panel, even when changing lamps. Nylon mounting rings are available on selectors. Elastomer panel seals keep liquids from entering through the panel hole and operating for long life and reliability. Modern,.5 inch square legend plates have large, bold legends that are easy to read. Guard rings for pushbuttons allow for an extended or guarded button, depending on the type of operation desired. Lenses, buttons, and knob actuators are available in a variety of brilliant colors to make it easy to distinguish among various functions. Suitable for use in NEMA 4 and enclosures. UL and CSA listed UL File no. E25 CSA Certified no. 2067 Application note: Enclosures are based, in general on the broad definitions outlined in NEMA Standards. Therefore, it will be necessary to ascertain that a particular enclosure will be adequate when exposed to the specific conditions that might exist in intended applications. Except as might otherwise be noted, all references to products relative to NEMA enclosure types are based on Senasys evaluation only. LAMPS LEGEND PLATES TERMINALS GUARD RINGS PANEL SEALS MOUNTING RINGS LENSES, BUTTON, KNOB ACTUATORS SENASYS 5

PW Miniature oiltight controls PW CATALOG LISTINGS Mechanical, elctronic duty, and solid state contact blocks PW operators Legend plates Accessories Dimension drawings PW devices may be ordered as components or as units. By components, the operators, contact blocks (in any combination up to four per operator, except lighted devices), and legend plates are ordered by separate catalog listings. By units, the parts come in a single box under one catalog listing. Example: Catalog listing PWP2E-B29 By components order: PWP (operator with red button, page 86) PWPZ2 (guard ring for extended button, page 86) PWCE (contact block, page 8) PWNB29 (legend plate, page 02) By unit order: PWP2 (operator, red button, with guard, page 86) E (contact block) -B29 (legend plate) Example: Catalog listing PWSDM02DEAD-B9 (see page 94) PWS (category) D (selector action) M (cam code) 02 (black knob) D (contact block) E (contact block) A (no block in the slot) D (contact block) -B9 (legend plate) 52 SENASYS

Miniature oiltight controls PW GENERAL PURPOSE ELECTRONIC DUTY (SILVER CONTACTS Description Push-On N.O.- N.C. Form C PWCM PWCC ELECTRICAL RATING GENERAL PURPOSE ELECT. DUTY Form C N.O.- N.C. Silver Contacts Amperes LOW LEVEL ELECTRONIC DUTY (GOLD BIFURCATED CONTACTS) Description Volts AC DC 0 0 Make 7.5 5 Break.2 5 Load.5 P.F. Ind. Res. N.O.- N.C. Form C PWCL 5 Amps continuous carrying current Notes: UL recognized. 2 To be used where stable contact resistance and high reliability over extended length of time is required. PWC MECHANICAL CONTACT BLOCKS Easy to assemble mechanical contact blocks that snap in place have screw,.250/.0 x.02 inch push-on, or.00 x.050 inch printed wiring board terminals. Up to four contact blocks, in any combination, may be used per operator (two with lighted push-buttons). Switches in the category have been designed to transfer the specified electrical load. When used under such low energy conditions recognition must be given to continuity problems which can arise during installation or over the life of the switch due to environmental factors. Note that the complete catalog listing is given for ordering blocks separately. The bold-face digit in the listing is for use when the catalog listing for a complete control is made up by the customer. The letter A is used in a complete selector or selector push catalog listing to indicate a slot where a contact block is not required. ELECTRICAL RATING LOW LEVEL ELECTRONIC DUTY Form C N.O.- N.C. Gold Contacts 2 Amperes Volts Make Break Load AC max. 20 DC max. 0 0 AC/DC typ. 0.5.00 0.5.00 Res. Ind. Res. Ind./ Res. Amp continuous carrying current Push-On Information about solid state contact blocks is on the following pages. STANDARD DUTY PWB Catalog Listings Description Circuitry Push-On PWB ELECTRICAL RATING STANDARD DUTY N.O. Form X N.C. Form Y PWCD PWCE PWCF PWCG PWCN PWCP Form X N.O. and Y N.C. Silver Contacts NEMA Contact Rating: AC B50, DC P50 Amperes Volts Make Break Load AC 20 DC 25 0...5 P.F. Ind. 0 Amps continuous carrying current E.C. = Early Closing L.O. = Late Opening SENASYS 5

PW Miniature oiltight controls PWP UNLIGHTED MOMENTARY PUSHBUTTONS Suitable for use in NEMA 4 and enclosures. Contacts ( terminals) No contact block N.O.. N.C. SPDT (Silver contacts) SPDT (Gold contacts) 2 Extended PWP22 PWP2 PWP26 PWP22D PWP2D PWP26D PWP22E PWP2E PWP26E PWP22M PWP2M PWP26M PWP22L PWP2L PWP26L Full Guard PWP2 PWP PWP6 PWP2D PWPD PWP6D PWP2E PWPE PWP6E PWP2M PWPM PWP6M PWP2L PWPL PWP6L Full Guard Lg. Opening PWP42 PWP4 PWP46 PWP42D PWP4D PWP46D PWP42E PWP4E PWP46E PWP42M PWP4M PWP46M PWP42L PWP4L PWP46L Notes: For other available mechanical contact blocks, refer to page 8. contact blocks may be ordered separately, or the contact block suffix letters may be added to the operator catalog listing. Increase the list price accordingly. Up to four contact blocks. in any combination, may be used per operator. 2 To order other button colors, substitute the number of the color desired for the last number of the catalog listing. For example: PWP46L Replace with 7 for blue button to get PWP47L 5 Blue 7 White 8 Legend plates are located on page02. They may be combined with the listing (as shown below) or ordered separately. Include the price of the legend plate when figuring the cost of the unit. Example: operator contact block legend plate PWP42 D- B28 PWP OPERATORS WITHOUT RING PWP2 PWP PWP5 Blue White PWP6 PWP7 PWP8 SEPARATE RINGS FOR PWP Extended button Full guard Large opening PWPZ2 PWPZ PWPZ4 54 SENASYS

Miniature oiltight controls PW PWM UNLIGHTED MOMENTARY MUSHRM HEAD PUSHBUTTONS Suitable for use in NEMA 4 and enclosures. Contacts,2 No contact block N.O.. N.C. SPDT (Silver contacts) SPDT (Gold contacts) No.25 dia. PWM PWM22 PWM2 PWM25 PWM22D PWM2D PWM25D PWM22E PWM2E PWM25E PWM22M PWM2M PWM25M PWM22L PWM2L PWM25L.5 dia. PWM PWM2 PWM PWM5 PWM2D PWMD PWM5D PWM2E PWME PWM5E PWM2M PWMM PWM5M PWM2L PWML PWM5L Notes:,2, and 4 are on the facing page. PWM SEPARATE BUTTONS.25 dia. PWMZ22 PWMZ2.5 dia. PWMZ2 PWMZ PWM OPERATORS WITH LEGENDED BUTTONS Legend EMERG. STOP EMERG. RETURN.25 dia. PWM2-T04.5 dia. PWM-T04 PWM5-T6.5 sq. PWM4-T04 PWM LEGENDED BUTTONS Legend.25 dia..5 dia. EMERG. STOP EMERG. RETURN PWMZ2-T04 PWMZ-T04 PWMZ5-T6 SENASYS 55

PW Miniature oiltight controls PWP LIGHTED MOMENTARY PUSHBUTTONS Suitable for use in NEMA 4 and enclosures. See page 58 for Separate parts. EXTENDED LENS TYPE No Lamp 6 to 8 volt OL-28BP lamp 2 to 4 volt OL-82BP lamp 24 to 28 volt 0/20 VAC Transformer OL-28BP lamp 20V AC/DC Resistor PWH20 PWH20 PWH204 PWH206 PWH22 PWH2 PWH224 PWH226 PWH2 PWH2 PWH24 PWH26 PWH25 PWH25 PWH254 PWH256 PWH22 PWH22 PWH224 PWH226 PWH2 PWH2 PWH24 PWH26 of Termination PWH250 PWH250 PWH2504 PWH2506 PWH252 PWH252 PWH2524 PWH2526 PWH25 PWH25 PWH254 PWH256 PWH255 PWH255 PWH2554 PWH2556 PWH26 PWH26 PWH264 PWH266 PWH27 PWH27 PWH274 PWH276 PWB PWH290 PWH290 PWH2904 PWH2906 PWH292 PWH292 PWH2924 PWH2926 PWH29 PWH29 PWH294 PWH296 PWH295 PWH295 PWH2954 PWH2956 PWH29 PWH29 PWH294 PWH296 PWH296 PWH296 PWH2964 PWH2966 Notes: For mechanical contact blocks, refer to page 8. Contact blocks may be ordered separately, or the contact block suffix letters may be added to the operator catalog listing. Increase the list price accordingly. Up to two contact blocks may be used per operator. 2 To order other button colors, substitute the number of the color desired for the last number of the catalog listing. For example: PTH26 Replace with 5 For yellow button to get PTH25 5 Blue 7 White 8 Legend plates are located on page 02. They may be combined with the listing (as shown below) or ordered separately. Inclued the price of the legend plate when figuring the cost of the unit. Example: Operator Contact block Legend plate PWH DD - B8 56 SENASYS

PWH LIGHTED MOMENTARY PUSHBUTTONS Miniature oiltight controls PW FULL GUARD No Lamp 6 to 8 volt OL-28BP lamp 2 to 4 volt OL-82BP lamp 24 to 28 volt 0/20 VAC Transformer OL-28BP lamp 20V AC/DC Resistor Lens 2 PWH0 PWH0 PWH04 PWH06 PWH2 PWH PWH24 PWH26 PWH PWH PWH4 PWH6 PWH5 PWH5 PWH54 PWH56 PWH2 PWH2 PWH24 PWH26 PWH PWH PWH4 PWH6 of Termination PWH50 PWH50 PWH504 PWH506 PWH52 PWH52 PWH524 PWH526 PWH5 PWH5 PWH54 PWH56 PWH55 PWH55 PWH554 PWH556 PWH66 PWH6 PWH64 PWH66 PWH7 PWH7 PWH74 PWH76 PWB PWH90 PWH90 PWH904 PWH906 PWH92 PWH92 PWH924 PWH926 PWH9 PWH9 PWH94 PWH96 PWH95 PWH95 PWH954 PWH956 PWH9 PWH9 PWH94 PWH96 PWH96 PWH96 PWH964 PWH966 Notes:,2,, and 4 are on the facing page. FULL GUARD LARGE OPENING No Lamp 6 to 8 volt OL-28BP lamp 2 to 4 volt OL-82BP lamp 24 to 28 volt 0/20 VAC Transformer OL-28BP lamp 20V AC/DC Resistor Lens 2 PWH40 PWH40 PWH404 PWH406 PWH42 PWH4 PWH424 PWH426 PWH4 PWH4 PWH44 PWH46 PWH45 PWH45 PWH454 PWH456 PWH42 PWH42 PWH424 PWH426 PWH4 PWH4 PWH44 PWH46 of Termination PWH450 PWH450 PWH4504 PWH4506 PWH452 PWH452 PWH4524 PWH4526 PWH45 PWH45 PWH454 PWH456 PWH455 PWH455 PWH4554 PWH4556 PWH46 PWH46 PWH464 PWH466 PWH47 PWH47 PWH474 PWH476 PWB PWH490 PWH490 PWH4904 PWH4906 PWH492 PWH492 PWH4924 PWH4926 PWH49 PWH49 PWH494 PWH496 PWH495 PWH495 PWH4954 PWH4956 PWH49 PWH49 PWH494 PWH496 PWH496 PWH496 PWH4964 PWH4966 Notes:,2, are on the facing page. SENASYS 57

PW Miniature oiltight controls PWH SEPARATE PARTS Suitable for use in NEMA 4 and enclosures. OPERATORS, LESS GUARD AND LENS Lamp No Lamp PWH0 6 to 8 V PWH2 2 to 4 V PWH 24 to 28 V PWH5 0/20 VAC Transf. PWH2 20V AC/DC Resistor PWH of Termination Standard Units PWH50 PWH52 PWH5 PWH55 PWH6 PWH7 PWB PWH90 PWH92 PWH9 PWH95 PWH9 PWH96 SEPARATE LENSES Blue White PWHZ PWHZ4 PWHZ5 PWHZ6 PWHZ7 PWHZ8 SEPARATE GUARDS For extended button Full guard Full guard (lg. opening) Listing PWHZ2 PWHZ PWHZ4 REPLACEMENT MOUNTING RING Single lighted devices Listing PWZ02 REPLACEMENT LAMPS FOR PWH, PWL AND PWD Lamps T - /4 5-6 volts.20 amp at 6 volts OL-28BP (G.E. 728, CM7-728) 2-4 volts.08 amp at 4 volts OL-28BP (G.E. 782, CM7-782) 24-28 volts.04 amp at 28 volts OL-28BP (G.E. 787, CM7-787) Min. Order Qty. 0 0 0 Catalog Listing PWZ4 PWZ4 PWZ47 These lamps can only be purchased in multiples of 0. 58 SENASYS

Miniature oiltight controls PW PWD DUAL LAMP INDICATORS Suitable for use in NEMA 4 and enclosures. No Lamp (order lamps separately from lamp chart, page ) 6 to 8 volt OL-28BP lamp 2 to 4 volt OL-82BP lamp 24 to 28 volt 20V AC/DC Resistor Lens, / / / / / / / / / / / / / / / / / / / / of Termination PWDA0 PWDA50 PWDA0 PWDA50 PWDA044 PWDA5044 PWDA066 PWDA5066 PWDA06 PWDA506 PWDA2 PWDA52 PWDA PWDA52 PWDA244 PWDA5244 PWDA266 PWDA5266 PWDA6 PWDA526 PWDA PWDA52 PWDA PWDA5 PWDA44 PWDA544 PWDA66 PWDA566 PWDA6 PWDA56 PWDA5 PWDA55 PWDA5 PWDA55 PWDA544 PWDA5544 PWDA566 PWDA5566 PWDA56 PWDA556 PWDA2 PWDA6 PWDA2 PWDA6 PWDA244 PWDA644 PWDA266 PWDA666 PWDA26 PWDA66 Notes: To order other lens colors, substitute the numbers of the colors desired for the last two numbers of the catalog listing. Examples: PWDF246 (/ lens) PWDF78 (Blue/White lens) 4 6 Blue 7 White 8 Legend plates are located on page 02. They may be combined with the listing (as shown below) or ordered separately. Include the price of the legend plate when figuring the cost of the unit. Example: operator legend plate G PWDF B00 Legend inserts are available for these indicators. Catalog listings are: Blank Insert Special Legending PWNR00 PWNR99 To order a special legend, specify: Catalog listing PWNR99. The desired legending (6 characters.09 in./2,78mm size will fit in legend areas G and H). The quantity. SEPARATE PWD LENSES / / / Blue/Blue White/White / Listing PWDZF PWDZF44 PWDZF66 PWDZF77 PWDZF88 PWDZF6 H SENASYS 59

PW Miniature oiltight controls PWL INDICATORS Suitable for use in NEMA 4 and enclosures. STANDARD INDICATORS Lens of Termination PWB No Lamp (order lamps separately from lamp chart, page 68) PWLA0 PWLB0 PWLB05 PWLB06 PWLA50 PWLB50 PWLB505 PWLB506 PWLA90 PWLB90 PWLB905 PWLB906 6 to 8 volt OL-28BP lamp PWLA0 PWLB PWLB25 PWLB26 PWLA52 PWLB52 PWLB525 PWLB526 PWLA92 PWLB92 PWLB925 PWLB926 2 to 4 volt OL-82BP lamp PWLA PWLB PWLB5 PWLB6 PWLA5 PWLB5 PWLB55 PWLB56 PWLA9 PWLB9 PWLB95 PWLB96 24 to 28 volt PWLA5 PWLB5 PWLB55 PWLB56 PWLA55 PWLB55 PWLB555 PWLB556 PWLA95 PWLB95 PWLB955 PWLB956 0/20 VAC Transformer OL-28BP lamp PWLA2 PWLB2 PWLB25 PWLB26 PWLA6 PWLB6 PWLB65 PWLB66 PWLA9 PWLB9 PWLB95 PWLB96 20V AC/DC Resistor PWLA PWLB PWLB5 PWLB6 PWLA7 PWLB7 PWLB75 PWLB76 PWLA96 PWLB96 PWLB965 PWLB966 Notes: To order other lens colors, substitute the number of the color desired for the last number of the catalog listing. For example: PWLB6 2 Legend plates are located on page 02. They may be combined with the listing (as shown below) or ordered separately. Include the price of the legend plate when figuring the cost of the unit. Replace with 7 For blue button To get PWLB7 5 Blue 7 White 8 Example: Operator Legend plate PWLB B29 SEPARATE STANDARD INDICATOR LENS Blue White Listing PWLZB PWLZB5 PWLZB6 PWLZB7 PWLZB8 60 SENASYS

PWL INDICATORS Miniature oiltight controls PW PUSH-TO-TEST INDICATORS No Lamp (order lamps separately from lamp chart, page 68) 6 to 8 volt OL-28BP lamp 2 to 4 volt OL-82BP lamp 24 to 28 volt 0/20 VAC Transformer OL-28BP lamp 20V AC/DC Resistor Lens PWLR0 PWLP0 PWLP05 PWLP06 PWLR0 PWLP PWLP25 PWLP26 PWLR PWLP PWLP5 PWLP6 PWLR5 PWLP5 PWLP55 PWLP56 PWLR2 PWLP2 PWLP25 PWLP26 PWLR PWLP PWLP5 PWLP6 of Termination PWLR50 PWLP50 PWLP505 PWLP506 PWLR52 PWLP52 PWLP525 PWLP526 PWLR5 PWLP5 PWLP55 PWLP56 PWLR55 PWLP55 PWLP555 PWLP556 PWLR6 PWLP6 PWLP65 PWLP66 PWLR7 PWLP7 PWLP75 PWLP76 PWB PWLR90 PWLP90 PWLP905 PWLP906 PWLR92 PWLP92 PWLP925 PWLP926 PWLR9 PWLP9 PWLP95 PWLP96 PWLR95 PWLP95 PWLP955 PWLP956 PWLR9 PWLP9 PWLP95 PWLP96 PWLR96 PWLP96 PWLP965 PWLP966 Notes: and 2 are on the facing page. SEPARATE PUSH-TO-TEST INDICATOR LENS Blue White Listing PWLZP PWLZP5 PWLZP6 PWLZP7 PWLZP8 PUSH-TO-TEST CIRCUITRY PW2 PUSH-TO TEST L SIGNAL CONTACT NC C PL L2 TEST NO SENASYS 6

PW Miniature oiltight controls PWS AND PWK 60º SELECTORS Suitable for use in NEMA 4 and enclosures. See page 8 for most commonly ordered listings. PWS KNOB OR WING LEVER SELECTORS Example: PWS E Selector Action 2 POSITION B Maintained. D Spring return from right. POSITION B Cam Code Add two digits from circuitry chart below. 60 º Selector Ordering Instructions. Match your circuit requirements in one cam code column in the chart below. PWS PWK KEY OPERATED SELECTORS PWK KEY: X Circuit Closed O Circuit Open E Maintained. F Spring return from left. G Spring return from right. H Spring return from left and right. 4 POSITION J Maintained. PWS ONLY 5-POSITION R Maintained 4 2 Slot Position Slot D block 2 E block no block 4 E block 2. Develop the catalog listing of the unit. Insert the shaded numbers/letters only. See example key selector below or knob selector above. When selecting a unit, determine the number of positions, the circuitry desired (for the cam code), and contact block(s) required. Use only cam code column per selector. Choose the key withdrawal and key code (key operators) or color of knob or wing lever (for selectors).. Add contact block letter(s) for curcuits desired. One contact block per slot in the operator. Blocks must be placed in the specified slot for proper circuitry. 4. Complete the listing with the legend plate code. PWS E B 02 DEAE -B49 Selector Selector Action Cam Code Actuator & Contact Block(s) Legend Plate Note: Letter A indicates no block in slot. Complete listing is PWSEB02DEAE-B49. Slot No. 2 4 Cam Code: Selector Position: Contact Blocks Electronic Duty N.O.- N.C. Standard Duty PWCM PWCL PWCM PWCL PWCM PWCL PWCM PWCL PWCC PWCB PWCC PWCB PWCC PWCB PWCC PWCB PWCE PWCD PWCE PWCD PWCE PWCD PWCE PWCD PWCG PWCF PWCG PWCF PWCG PWCF PWCG PWCF PWP PWCP PWCN PWCP PWCN PWCP PWCN PWCP PWCN Contacts N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. *This cam code is for use with maintained selector action only. Note: If your circuitry requirements are not included in this table, contact Senasys. 2-Pos. -Position 4-Pos. 5-Pos. M B C D* J K L E L F 2 X O X O O X X O X O- O X O X X O X O 4 O X X O O X X O X O X O O X- X O X O X O X O O X 4 45 X O X X O X 59 SENASYS, a Honeywell division

Miniature oiltight controls PW + + = Complete Unit PWS (Choose One) Wing Knob Lever 02 2 0 04 Orange 4 05 5 06 6 07 Blue 7 08 White 8 0 Operator Without Acutator For plastic mounting rings instead of aluminum rings change the 0 to 2 (knobs), change the to (wing levers). Plastic mounting rings are typically used where atmosphere or cleaning agents attack aluminum mounting rings. PWK Key withdrawal in maintained positions only 2 Position 22 2 24 Position 22 4 5 6 7 8 4 Position 48 PWK Key Code 2 4 5 6 7 8 9 0 Withdrawal Position only 2 only & 2 only 2 only only & 2 2 & &, 2 &,2,, & 4 Mfgr. I.D. No. Stamped on Key T2 T5 T59 T7 T78 T82 T98 T246 T24 T82 The key code identifies which key will operate the selector switch. Master Key: PTKZ8: Will operate any of above key codes. Contact Block(s) Choose circuitry for mechanical contact blocks from chart below. Refer to next page for solid state units. Up to four mechanical contact blocks may be used per operator. Add the contact block suffix letter)s) to the catalog listing. For omission of a block, insert the letter A. If blocks are ordered separately, omit all contact block letters. STD Duty Elect. Duty A No Contact Block D Term. N.O. E Term. N.C. F Term.* N.O. G Term.* N.C. N PWB Term. N.O. P PWB Term. N.C. C (Silver) Term.*Form C B (Gold) Term.*Form C M (Silver) Term Form C L (Gold) Term Form C *UL Recognized Legend Plate Add legend plate code and separate with hyphen. See page for special legend plates. Omit if legend plate is ordered separately. STANDARD LEGEND PLATES All words are.4 (,57mm) high characters HAND AUTO JOG-RUN OFF-ON STOP-START TAPE-MANUAL HAND-OFF-AUTO Catalog Listings Metal PWNB4 PWNB6 PWNB9 PWNB45 PWNB60 PWNB49 Description Aluminum Aluminum epoxy coating on contrasting nylon base () epoxy coating on contrasting nylon base (white) epoxy coating on contrasting nylon base (white) STANDARD LEGEND PLATES Separate Selector Actuators Orange Blue White Knobs PWSZ02 PWSZ0 PWSZ04 PWSZ05 PWSZ06 PWSZ07 PWSZ08 Plastic PWNF4 PWNF6 PWNF9 PWNF45 PWNF60 PWNF49 Catalog Listings PWNB PWNF PWNH PWNT Levers PWSZ2 PWSZ PWSZ4 PWSZ5 PWSZ7 PWSZ8 SENASYS, a Honeywell division 60

PW Miniature oiltight controls PWU 60º DETENT SELECTOR-PUSH Suitable for use in NEMA 4 and enclosures. PWU SELECTOR-PUSH Example: PWU E Selector-Push Action 2 POSITION B Maintained. FA Cam Code Add two digits from circuitry chart below. 60 º Selector Ordering Instructions PWU CURCUITRY SELECTION CHART KEY: X Circuit Closed O Circuit Open Slot No. 2 4 PWCM PWCL PWCM PWCL PWCM PWCL PWCM PWCL PWCC PWCB PWCC PWCB PWCC PWCB PWCC PWCB PWCE PWCD PWCE PWCD PWCE PWCD PWCE PWCD 6 SENASYS, a Honeywell division PWCG PWCF PWCG PWCF PWCG PWCF PWCG PWCF POSITION E Maintained. 4 2 Slot Cam Code: Selector Position: Contact Blocks Electronic Duty N.O.- N.C. Standard Duty PWB PWCP PWCN PWCP PWCN PWCP PWCN PWCP PWCN Contacts N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. Note: If your circuitry requirements are not included in this table, contact Senasys. Slot D block 2 E block no block 4 no block Push Positions Free Depress Free Depress Free Depress Free Depress Free Depress Free Depress Free Depress Free Depress KA 2. Match your circuit requirements in one cam code column in the chart below. 2. Develop the catalog listing of the unit. Insert the shaded numbers/letters only. See example.when selecting a unit, determine the number of positions, the circuitry desired (for the cam code), and contact block(s) required. Use only cam code column per selector.. Add contact block letter(s) for curcuits desired. One contact block per slot in the operator. Blocks must be placed in the specified slot for proper circuitry. 4. Complete the listing with the legend plate code. Example: catalog listing PWUEFA2DEAA-B6. PWU Selector KB 2 E Selector Action KC 2 FA Cam Code 2 Actuator & 2-Position GC FC FD 2 2 2 DEAA Contact Block(s) Note: Letter A indicates no block in slot. LA 2 -B6 Legend Plate LB 2 MA 2

Miniature oiltight controls + = Complete Unit Actuator Legend Plate Contact Block(s) 2-black Add legend plate code and separate with hyphen. Choose circuitry for mechanical contact blocks See page for special legend plates. from chart below. Refer to next page for solid Omit if legend plate is ordered separately. state units. Up to four mechanical contact blocks may be used per operator. Add the contact block suffix letter)s) to the catalog listing. For omission of a block, insert the letter A. STANDARD LEGEND PLATES STD Duty If blocks are ordered separately, omit all contact block letters. A No Contact Block D Term. N.O. E Term. N.C. F Term.* N.O. G Term.* N.C. N PWB Term. N.O. P PWB Term. N.C. Elect. Duty C (Silver) Term.*Form C B (Gold) Term.*Form C M (Silver) Term Form C L (Gold) Term Form C *UL Recognized All words are.4 (,57mm) high characters HAND AUTO JOG-RUN OFF-ON STOP-START TAPE-MANUAL HAND-OFF-AUTO Catalog Listings Metal PWNB4 PWNB6 PWNB9 PWNB45 PWNB60 PWNB49 Description Aluminum Aluminum epoxy coating on contrasting nylon base () epoxy coating on contrasting nylon base (white) epoxy coating on contrasting nylon base (white) Plastic PWNF4 PWNF6 PWNF9 PWNF45 PWNF60 PWNF49 Catalog Listings PWNB PWNF PWNH PWNT AA BA CA DA EA EB FA -Position FB GA GB HA HB HC HD HE JA MB X O X X O X O O X X O X O O X X O O O X X X X O O X X O X X O O X X X O X O X X X X O O O X X O X X X O X X O X X O X X O O O X X O O X X O X X X O X X O X X O O X X O X X X O O X X O X X O X X O O X X X X O O X X O X X X O X X O O O O X X X X X O X O O O X SENASYS, a Honeywell division 62

PW Miniature oiltight controls PWN LEGEND PLATES Legend plates are /2 inches square. When ordering with an operator, add a hyphen and the last three digits (boldface type) to the LEGEND STYLE AND SIZES operator catalog listing. Add the corresponding list preice. when ordering legend plates separeatly, use the full catalog listing. Size of all capital alphabetic and numeric characters is:,57mm.4 Characters available are: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z &., - 0 2 4 5 6 7 8 9 /2 /4 /4 / 2 / /8 /8 SPECIAL LEGEND PLATES 5 /8 7 /8 Special legends consist of standard characters in standard areas. Special plate ordering Instructions Follow these easy steps:. Indicate quantity of each legended plate. 2 Select the legend plate style catalog listing from Chart.. Select the area where each legend is to appear from Chart 2. 4. For maximum number of characters and spaces per area,, see Chart. 5. Specify the legend consisting of instock characters from the above Legend Sty.e and Sizes chart. Coating Aluminum FORWARD ONE FUNCTION Chart Special Legend Plates Epoxy Coated Nylon Base Catalog Listing PWNF99 STOP START TWO FUNCTIONS OFF HAND AUTO ONE FUNCTION SPECIAL LEGEND PLATES Drawings show the legending areas lettered and Chart shows the number of letters and size that will fit into each area. A B C + + E F D EE FF Y + J K + + Z STANDARD LEGENDS All words are.4 (,57mm) high characters CLOSE EMERG. STOP (red) FORWARD JOG OFF ON OPEN RESET REVERSE START STOP STOP.20/5,6 size STOP (red) HAND-AUTO JOG-RUN OFF-ON STOP-START TAPE-MANUAL HAND-OFF-AUTO BLANK LEGEND PLATES Catalog Listings Metal PWNB0 PWNB04 PWNB06 PWNB0 PWNB7 PWNB8 PWNB9 PWNB2 PWNB24 PWNB28 PWNB29 PWNB0 PWNB57 PWNB4 PWNB6 PWNB9 PWNB45 PWNB60 PWNB49 Description Aluminum Aluminum epoxy coating on contrasting nylon base () Word Area A,D,J,K, B,C,E,F, Y,Z,EE,FF P,Q Legend One Function Two Function 2-line One Function Chart Character Count Plastic PWNF0 PWNF04 PWNF06 PWNF0 PWNF7 PWNF8 PWNF9 PWNF2 PWNF24 PWNF28 PWNF29 PWNF0 PWNF57 PWNF4 PWNF6 PWNF9 PWNF45 PWNF60 PWNF49 Catalog Listings PWNB PWNF Maxinum number of characters and spaces per area..4 (,57mm) Example: Special Legend Plate Ordering Catalog Listing PWNF99 Legend Area A B & C J & K 5 2 Example CLOSE HAND AUTO MOTOR START 66 SENASYS

PWV POTENTIOMETERS Miniature oiltight controls PW PWZ ACCESSORIES Description Mounting ring - single lighted devices -/2 hole plug Gray Aluminum Locking wrench terminal connectors (pre-insulated) Wire size 4-6,.0 x.02* (Molex ETC BB-85) Wire size 8-22,.0 x.02* (Molex ETC AA-84) Lamps T -/4 5-6 volts.20 amp at 6 volts -,000 hrs. OL-28BP (G.E. 782, CM7-728) 2-4 volts.08 amp at 4 volts-40,000 hrs. OL-82BP (G.E. 782, CM7-782) 24-28 volts.04 amp at 28 volts-7,000 hrs. OL-87BP (G.E. 787, CM7-787) *For.250 x.02, wire size 4-6: Molex ETC BB-84 **For.250 x /02, wire size 8-22: Molex ETC AA-840 Min. Order Quantity Min. order quantity: 00 (Must be purchased in multiples of 00) Min. order quantity: 0 (Must be purchased in multiples of 0) Example PWZ02 PWZ05 PWZ06 PWZ04 PWZ50 PWZ52 PWZ4 PWZ4 PWZ47 PW CONNECTOR BLOCKS PW connector blocks allow easy access to individual operator/indicator units when printed wiring board terminals are used. These connector blocks eliminate the problem of unsoldering and resoldering to the printed circuit board if a circuit change or replacement of blocks/operators is needed. Connector blocks are soldered to the printed circuit board allowing the PW blocks/operators to be plugged in or unplugged. ENCLOSURES FOR PW CONTROLS Numerous panel manufacturers build cabinets, panel-boards or enclosures for use with PW controls. Your local Senasys Branch Office or Authorized Distributor can assist you with information on local availability of enclosures. Hoffman Engineering Company of Anoka, Minnesota is one supplier of enclosures. Catalog Listing PWZ62 PWZ6 PWZ64 Use With: The Listed PW Unites below (Printed wiring board terminals) Two circuit solid state blocks PWBJ2C, PWBJC PWBJ2C, PWBJC PWBL2C, PWBLC PWBM2C, PWBMC PWBS2C, PWBSC PWBT2C, PWBTC Solid state pushbutton types PWH28, PWH8, PWH48 and indicator types PWLAB, PWLB8 One circuit solid state blocks PWBB2C, PWBBC PWBC2C, PWBCC PWBD2C, PWBDC PWBE2C, PWBEC SENASYS 67

PW Miniature oiltight controls PW MOUNTING DIMENSIONS UNLIGHTED UNITS Operator housings are shown with screw or push-on terminal contact blocks. The dimensions indicated in phantom are for PWB termination or form C contact blocks with screw termination. *Minimum center to center distance between adjacent three, four, and fiveposition PWS units with wing levers should be 2.225 (54,0mm) horizontally and.500 (8,mm) vertically. 68 SENASYS

Miniature oiltight controls PW PW MOUNTING DIMENSIONS LIGHTED UNITS Operator housings are shown with screw or push-on terminal contact blocks. The dimensions indicated in phantom are for PWB termination or form C contact blocks with screw termination. PW CONNECTOR BLOCKS DUAL LAMP INDICATOR SINGLE LAMP UNITS DIMENSIONS SHOWN ARE FOR REFERENCE ONLY SENASYS 69

PW Miniature oiltight controls PW MOUNTING DIMENSIONS MOUNTING HOLE DIMENSIONS FORM C SCREW TERMINAL Three.062 in. (.57mm) and two.02 in. (0.8mm) spacer seals are provided with each switch. They can be used in combinations to adjust to your panel thickness. Panel Thickness.062,57 mm.09 2,6 mm.25.8 mm.57,99 mm.87 4,75 mm.28 5,54 mm.250 6,5 mm.062 (,57mm) thick 2 2 Number of Spacers.02 (o,8mm) thick 2 0 0 0 WARNING: Resistor equipped devices require air space to dissipate heat. Minimum mounting centers both vertically and horizontally should be -/2. FORM X AND Y WITH PWB TERMINALS CONTACT BLOCKS MECHANICAL CONTACT BLOCKS wgt..5 oz. 67 SENASYS, a Honeywell division