IFR 4000 Portable Nav/Comm Test Set

Similar documents
Avionics. IFR 4000 Nav/Comm Test Set

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

Avionics. IFR 4000 Nav/Comm Test Set

Avionics. IFR 6000 Ramp Test Set

FM Modulation. Accuracy. Total. Harmonics. Input Range. Frequency. Range. Deviation. Range. Modulation. Accuracy. Audio In Switchable Loads.

FREEDOM Communications System Analyzer R8100 DATA SHEET

Wireless Portable Radio Communications Test Set. Advanced Test Equipment Rentals ATEC (2832)

FREEDOM Communications System Analyzer R8100 DATA SHEET

FREEDOM Communications System Analyzer R8100 DATA SHEET

2.9GHz SPECTRUM ANALYZER

Model 845-M Low Noise Synthesizer

FREEDOM Communications System Analyzer R8000C DATA SHEET

FREEDOM Communications System Analyzer R8000C DATA SHEET

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Chapter 6 Specifications

FREEDOM Communications System Analyzer R8600 DATA SHEET

khz to 2.9 GHz Spectrum Analyzer

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Avionics. IFR 6015 Ramp Test Set

Agilent E4428C ESG Analog Signal Generator

Model 865-M Wideband Synthesizer

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Agilent 8560 E-Series Spectrum Analyzers

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

khz to 2.7 GHz Spectrum Analyzer

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Chapter 5 Specifications

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Military Communications

Radio Communications Series Portable Radio Communications Test Set

Model 865-M Wideband Synthesizer


Signal Sources. 2026Q CDMA Interferer Multisource Generator. Advanced Test Equipment Rentals ATEC (2832)

y Over-the-air radio testing ystandard instruments included in the 3515: yrf Signal Generator ymodulation Meters yaudio Generators y RF Power Meters

R&S FSC Spectrum Analyzer Specifications

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

RF Signal Generator RIGOL TECHNOLOGIES, INC.

Phase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On

DSA700 Series Spectrum Analyzer

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Agilent ESA-L Series Spectrum Analyzers

2026Q CDMA/GSM Interferer MultiSource Generator

8800SX. Advanced Analog and Digital Radio Test for Both Bench and Field Test Environments. Digital Radio Test Set. Data Sheet

Function/Arbitrary Waveform Generator

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator.

Spectrum Analyzer R&S FS300

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-M Specification 1.8 BNC

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Signal Sources Series Low Noise Signal Generator

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Solid State General Communication Power Amplifier

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

S5101 Handheld Radio Communication Analyzer

Chapter 6 Specifications

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

NI PXIe-5601 Specifications

2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Agilent N9320B RF Spectrum Analyzer

Signal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features

8800SX. Advanced Analog and Digital Radio Test Set for Bench and Field Environments. Digital Radio Test Set. Data Sheet

Handheld Spectrum Analyzer R&S FSH3

HZ530 Near-Field Probe Set

R&S FSH4/8 Spectrum Analyzer Specifications

R&S FSWP Phase Noise Analyzer Specifications

100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability

Keysight Technologies E8257D PSG Microwave Analog Signal Generator

Agilent 8648A/B/C/D Signal Generators

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Data Sheet

Wireless Analog and Digital Radio Test Set. Hybrid Bench and Portable Radio Test System for Complete Testing of Analog and Digital Radios

Frequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz

Spectrum Analyzers 2680 Series Features & benefits

Agilent E4428C ESG Analog Signal Generator

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

TR-220. Datasheet. Multi-Function Test Set. Features. Transponder. Features DME

Military Communications

Arbitrary/Function Generator AFG1000 Series Datasheet

R&S SMB100N SIGNAL GENERATOR

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Complimentary Reference Material

HP 8560 E-Series Spectrum Analyzers Technical Specifications

Agilent E8247C/57C PSG CW and Analog Signal Generators

Keysight N9310A RF Signal Generator

Model 855 RF / Microwave Signal Generator

Keysight N9320B RF Spectrum Analyzer

NI PXIe-5663 Specifications

Function/Arbitrary Waveform Generator

This section lists the specications for the Agilent 8360 B-Series. generators, Agilent Technologies has made changes to this product

Transcription:

IFR 4000 Portable Nav/Comm Test Set Product Specification Note: A 15 minute warm-up period is required for all specifications. RF SIGNAL GENERATOR Marker Beacon Channel 72.0 to 78.0 MHz in 25 khz steps Marker Beacon Pre-set 74.5, 75.0 or 75.5 MHz Marker Beacon 72.0 to 78.0 MHz in 1 khz steps VOR Channel 108.0 to 117.95 MHz in 50 khz steps VOR Pre-set 108.0, 108.05 or 117.95 MHz VOR 107.0 to 118.0 MHz in 1 khz steps LOC Channel 108.1 to 111.95 MHz in 50 khz steps LOC Pre-set 108.1, 108.15 or 110.15 MHz LOC 107.0 to 113.0 MHz in 1 khz steps G/S Channel 329.15 to 335.0 MHz in 50 khz steps G/S Pre-set 334.25, 334.55 or 334.70 MHz G/S 327.0 to 337.0 MHz in 1 khz steps Comm AM Channel 10.0000 to 400.0000 MHz in 25 khz steps, 118.0000 to 156.0000 in 8.33 KHz steps Comm AM Preset 118.00, 137.00 or 156.00 MHz (VHF Band) 225.00, 312.00, 400.00 MHz (UHF Band) Comm AM 10.0000 to 400.0000 MHz in 1 khz steps Comm FM Channel 10.0000 to 400.0000 MHz in 12.5 or 25 khz steps Comm FM Pre-set 156.00, 165.00 or 174.00 MHz Comm FM 10.0000 to 400.0000 MHz in 1 khz steps Comm SSB Channel 10.0000 to 30.0000 MHz in 100 Hz steps SEL Channel 118.0 to 156.0 MHz in 25 khz steps SEL Pre-set 118.0, 137.0 or 156.0 MHz SEL 117.0 to 157.0 MHz in 1 khz steps Frequency Same as time base Output Level Single Carrier 10 MHz to 75 MHz -17 to -67 dbm in 0.5 db steps 75 MHz to 400 MHz +13 to -67 dbm in 0.5 db steps ±3 db Dual Mode LOC 0 dbm fixed ±2.5 db Dual Mode - G/S 0 to -76 dbm in 0.5 db steps ±3 db Tri-Mode Marker +13 dbm fixed ±2 db Tri-Mode - LOC -7 dbm fixed ±2 Hz Tri-Mode - G/S -7 to -83 dbm in 0.5 db steps ±3 db Single Carrier 10 MHz to 75 MHz -40 to -130 dbm in 0.5 db steps 75 MHz to 400 MHz -12 to -130 dbm in 0.5 db steps -12 to -39.5 dbm ±2.5 db -40 to -94.5 dbm ±2.0 db -95 to -120 dbm ±3 db Dual Mode - LOC -22 dbm fixed ±2 db Dual Mode - G/S -22 to -101 dbm in 0.5 db steps ±2.5 db Spectral Purity Harmonics <-20 dbc Non-harmonics Spurious <-35 dbc between 10 and 400 MHz VOR MODE VOR Tone Frequency 30 Hz Reference ±0.02% 30 Hz ±0.02% 1020 Hz ±0.02% 9960 Hz ±0.02% AM 30 and 9960 Hz tones 30% AM, each tone ±1% modulation 1020 Hz tone 30% AM 1020 Hz Morse Code 10% AM ± 2% modulation 0% to 55% AM (30, 9960 and 1020 Hz tones) <2.0 % in position March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 1

FM 30 Hz reference at ±480 Hz peak deviation on 9960 Hz sub- carrier ±25 Hz peak deviation Bearing To - From selectable Preset Bearing 0, 30, 60, 90, 120, 150, 180, 210, 240, 270, 300, and 330 Bearing 3600 digitally derived courses in 0.1 increments ±0.1 LOC MODE LOC Tone Frequency 90 Hz ±0.02% 150 Hz ±0.02% 1020 Hz ±0.02% 90 and 150 Hz Tones 20% AM each tone 1020 Hz Audio Tone 30% AM 1020 Hz Morse Tone 10% AM 0% to 28% AM (90 and 150 Hz Tones) 0 to 42% AM (1020 Hz tone) <2.5% in position LOC DDM Fixed ±0, 0.093, 0.155 or 0.200 DDM and tone delete ±0.0015 DDM (±1.5 μa) ±3% of setting +10 dbm output level) Sweep (Available only in dual and tri-modes) Sweep Rates Step Size Phase Shift 0 to ±30 μa 5 to 40 sec ±0.5º G/S MODE Tone Frequency 90 Hz ±0.02% 150 Hz ±0.02% 5 sec ±0.5 sec/sweep 0 to 120 degrees in 5 degree increments (150 Hz phase relative to 90 Hz) 90 and 150 Hz Tones 40% AM, each tone G/S DDM Fixed Phase Shift 0% to 50% AM (90 and 150 Hz tones) <2.5% in position ±0, 0.091, 0.175 or 0.400 DDM and tone delete ±0.5º ±0.003 DDM (±2.5 μa) ±3% of setting +10 dbm output level) ±0.8 DDM in 0.001 DDM steps ±0.0048 DDM (±4.0 μa) ±3% of setting +10 dbm output level) 0 to 120 degrees in 5 degree incre- ments (150 Hz phase relative to 90 Hz) ±0.4 in 0.001 DDM steps ±0.0025 DDM (±2.5 μa) ±3% of setting +10 dbm output level) MARKER MODE Marker Tone Frequency 400 Hz ±0.02% 1300 Hz ±0.02% 3000 Hz ±0.02% March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 2

Setting (single carrier only) Single Carrier Tri-Mode 95% AM ±5% modulation 0% to 95% AM <2.5% in position (-67 to +10 dbm) <5% in position COMM MODE (COMM AM, COMM FM, COMM SSB) COMM Tone Frequency Pre-set (AM) 1020 Hz ±0.02% Pre-set (FM) 1000 Hz ±0.02% Pre-set (SSB) 1000 Hz / (SSB) 25 to 3000 Hz Steps (SSB) AM ±6.25 Hz 25 Hz 1020 Hz tone 30% AM FM 0% to 95% AM (1% steps) <2.5% in position 1000 Hz tone 5 KHz deviation ±0.5% SSB USB/LSB offset carrier SEL MODE 1 to 15 KHz (1 KHz steps) <5% in position Provides amplitude modulation with SEL (SELective ling) tones SEL Tone Freq ± 0.02% Transmit Modes Single Continuous single transmission 7.5 sec interval (typical) Per SEL Tone EXTERNAL FREQUENCY COUNTER Frequency Antenna and s Resolution AUX I/O Connectors Resolution ANT Connector AUX I/O Connector 40% AM 0% to 55% AM <2.5% in position 10 to 400 MHz 100 Hz Same as time base, ±1 count 1 to 10 MHz 1 Hz Same as time base, ±1 count -35 dbm 1 Vp-p (from a 50 ohm source) POWER METER (RF I/O CONNECTOR) Frequency 10.0 to 400.0 MHz Power 0.1 to <1 W Resolution 0.01 W (NOTE 1) 1 to <100 W Resolution 0.1 W (NOTE 1) 100 to 1999 W Resolution 1 W <100 MHz ±12% of reading, ±1 count, (NOTE 2) CW only 100 to 400 MHz ±8% of reading, ±1 count, (NOTE 2) CW only Duty Cycle 10 W, continuous >10 W to 20 W, 3 min on, 2 min off >20 W to 30 W, 1 min on, 2 min off March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 3

AM METER Audio 50 to 3000 Hz Percent 10% to 99% ±10% of reading -20 dbm +15 dbm FM METER Audio 50 to 3000 Hz Deviation 1 to 15 khz ±(0.4 khz + 8% of reading) Minimum Input Level -35 dbm SWR METER (SWR CONNECTOR) Frequency 10.0 MHz to 410.0 MHz SWR <3:1 ±0.2, ±20% of reading SWR 3:1 ±0.3, ±20% of reading 121.5/243 BEACON MONITOR (OPTION) Swept Audio Tone 100 Hz to 3000 Hz ±10% of reading -30 dbm 406 MHZ BEACON MONITOR (OPTION) -35 dbm INPUTS/OUTPUTS Input/Output 50 Ω typical Maximum Input Level 30 W, 1 min on, 2 min off VSWR 10 to 300 MHz <1.3:1 >300 to 400 MHz <1.35:1 Maximum Input Level SWR Connector Maximum Reverse Power VSWR Input/Output 50 Ω typical 0.5 W Output 50 Ω typical +25 dbm 10 to 300 MHz <1.3:1 >300 to 400 MHz <1.35:1 AUX Connector Maximum Input Level TIMEBASE (TCXO) Temperature Stability Aging BATTERY Duration INPUT POWER (TEST SET) Input Power Consumption 55 W maximum Input/Output 800 Ω typical 5 Vp-p maximum, 3 VDC maximum ±1 ppm ±1 ppm per year ±1 ppm when Auto Cal is performed Li Ion 16 W nominal at 18 VDC with charged battery Fuse Requirements 5 A, 32 VDC, type F >8 hrs continuous operation 11 VDC to 32 VDC INPUT POWER (SUPPLED EXTERNAL AC TO DC CONVERTER) Input 100 to 250 VAC, 1.5 A maximum, 47-63 Hz Main Supply Voltage Fluctuations 10% of the nominal voltage Transient Over-voltages According to installation category II March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 4

Environmental (Test Set) Use Pollution degree 2 Altitude 4800 meters Operating Temperature (NOTE 3) -20 C to 55 C Storage Temperature (NOTE 4) -30 C to 70 C Relative Humidity 80% from 5 C to <10 C 95% from 10 C to <31 C 75% from 31 C to <40 C 45% from 40 C to 50 C Environmental (Supplied External AC to DC Converter) Use Altitude Indoors 3,000 meters Temperature 5 C to 40 C Physical Characteristics Dimensions: Height Width Depth Weight (Test Set Only) Supplemental Information 11.2 in (28.5 cm) 9.1 in (23.1 cm) 2.7 in (6.9 cm) <8 lbs. (3.6 kg) Audio distortion characteristics are measured in a 20 Hz to 15 khz post detection bandwidth. All DDM measurements are made on RF output signal. Transit Drop MIL-PRF-28800F Class 2 Safety Compliance EMC EN 61326 UL-61010B-1 EN 61010-1 CSA 22.2 No 61010-1 External AC-DC Converter Certifications Safety Compliance EMI/RFI Compliance UL 1950 DS CSA 22.2 No. 234 VDE EN 60 950 EMC EN 61326 Transit Case Certifications FCC Docket 20780 Curve B Drop Test FED-STD-101C Method 5007.1 Paragraph 6.3, Procedure A, Level A Falling Dart Impact ATA 300 Category I Vibration, Loose Cargo FED-STD-101C Method 5019 Vibration, Sweep ATA 300 Category I Simulated Rainfall MIL-STD-810F Method 506.4 Procedure II of 4.1.2 FED-STD-101C Method 5009.1 Sec 6.7.1 Immersion MIL-STD-810F Method 512.4 Test Set Certifications Altitude, operating MIL-PRF-28800F Class 2 Altitude, not operating MIL-PRF-28800F Class 2 Bench Handling MIL-PRF-28800F Class 2 Blowing Dust MIL-STD-810F Method 510.4, Procedure 1 Drip-proof MIL-PRF-28800F Class 2 Explosive Atmosphere MIL-STD-810F Method 511.4, Procedure 1 Relative Humidity MIL-PRF-28800F Class 2 Shock, Functional MIL-PRF-28800F Class 2 Vibration Limits MIL-PRF-28800F Class 2 Temp, operating NOTE 5 MIL-PRF-28800F Class 2 Temp, not operating NOTE 6 MIL-PRF-28800F Class 2 NOTES Note 1 - External attenuator required for input power greater than 30 W Note 2 - specification excluding external attenuator Note 3 - Battery charging temperature range: 5 to 40 C (controlled by internal charger) Note 4 - Li Ion battery must be removed below -20 C and above 60 C Note 5 - Temperature range extended to -20 C to 55 C. Note 6 - Temperature range reduced to -30 C to 71 C. March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 5

Versions, Options and Accessories Order Number Description 72418 IFR 4000 Nav/Comm Ramp Test Set IFR 4000AR (U.S Military version w/ protective cover) 83402 4000OPT1 ELT (121.5/243 MHz beacon and 406 MHz COSPAS/SARSAT beacon test) Standard Accessories 9140 Antenna, 75 MHz NSN Information: 6625-01-516-4656 (IFR 4000) 6625-01-559-2384 (IFR 4000AR) 6625-01-553-1956 (IFR 4000 with ELT option installed) 9137 Antenna, telescoping 10238 Transit case 6081 Operation Manual (CD) 6087 Getting Started Manual 67366 AC/DC power supply 62302 Power cord, 110 V 64020 Power cord set, 220 V 62398 TNC (male) to TNC (male) coaxial cable 24140 TNC (female) shorting cap 56080 Spare fuse 24141 50 Ω load 63958 Flip cover (IFR 4000AR only) Optional Accessories 63656 Desk top stand 62400 RS-232 cable 6083 Maintenance Manual (CD) Extended Standard Warranties with Calibration for 4000 84354 Extended standard warranty 36 months with scheduled calibration 84356 Extended standard warranty 60 months with scheduled calibration For further information please contact: 10200 West York Street Wichita, KS 67215-8935 [USA] Phone: (316) 522-4981 Fax: (316) 524-2623 E: info-test@aeroflex.com or contact your sales office March 2015 IFR 4000 Portable Nav/Comm Test Set pg. 6