Report No.: HZ c

Similar documents
Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Report No.: HZ d

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

LM Test. for LED. Cabinet

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Morris Products 53 Carey Road, Queensbury, NY 12804

Cat# LED Classic Large Wall-Pack

Report No.: EASZE Page 2 of 14

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Eternal Shine Technology Co.,Ltd. EST

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

REVOLUTION LIGHTING TECHNOLOGIES INC

Photometric Test Report

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE:

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

IESNA LM79: 2008 Photometric Test Report

IES LM MEASUREMENT AND TEST REPORT For

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE:

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

NVLAP LAB CODE:

NVLAP LAB CODE:

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730



LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Photometric Test Report

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.



REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

INDEPENDENT TEST LABORATORY REPORT No

NVLAP LAB CODE:

Photometric Test Report

VAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report

Calibration Due Date Chroma Programmable AC Source 61604

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Transcription:

Test Summary Model L13T8DF450-CG4 Luminous Efficacy (Lumens /Watt) 121.4 Total Luminous Flux (Lumens) 2038.0 Power (Watts)/2 16.79 Power Factor 0.9957 CCT (K) 4912 CRI 81.5 Stabilization Time (Light & Power) 60 mins Note 5000K, Frosted lens Table 1: Executive Data Summary Test specifications: Date of Receipt : May 24, 2016 Date of Test : May 27, 2016 Test item : Total Luminous Flux, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters Reference Standard : IESNA LM-79-2008 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Prepared by: Leading Testing Laboratories Page 2 of 9

TABLE OF CONTENT LM-79-08 Test Report... 1 Test Summary... 2 Sample Photo... 4 TEST RESULTS... 5 Spectral Power Distribution - Sphere Spectroradiometer Method... 6 Chromaticity Diagram - Sphere Spectroradiometer Method... 7 Nominal CCT Quadrangles Sphere Spectroradiometer Method... 8 EQUIPMENT LIST... 9 TEST METHODS... 9 Seasoning of SSL Product... 9 Sphere-Spectroradiometer Method- Photometric and Electrical Measurements... 9 Prepared by: Leading Testing Laboratories Page 3 of 9

Sample Photo Sample view Equipment Under Test (EUT) Name : LED TUBE Model : L13T8DF450-CG4 Electrical Ratings : AC120-277V, 50/60Hz Product Description : G13 base, 5000K, Frosted lens, 4 feet tube, fixed ends Manufacturer of light source: SAMSUNG ELECTRONICS CO., LTD Model of LED light source: SPMWHX228FXXXXXXXX LED TUBEs supplied by a high frequency fluoresent lamp ballast: QTP 2x32T8/UNV ISN-SC Manufacturer : Maxlite Inc. Address : 12 York Ave.,West Caldwell,NJ 07006 Prepared by: Leading Testing Laboratories Page 4 of 9

TEST RESULTS Test ambient temperature was 24.8. Test orientation was Horizontal. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 65 minutes. Sphere-Spectroradiometer Method Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 277.0 R1 79 Voltage frequency (Hz) 60 60 R2 86.2 Test Current (A) 0.281 0.126 R3 91.7 Power Factor 0.9957 0.9646 R4 80.8 Test Power (W)/2 16.79 16.87 R5 79.2 THD A% 5.69 11.97 R6 80.7 Luminous Efficacy (lm/w) 121.4 120.8 R7 87.7 Total Luminous Flux (lm) 2038.0 2037.0 R8 66.5 Color Rendering Index (CRI) 81.5 R9 3.7 R9 3.7 R10 67.3 Correlated Color Temperature (CCT)(K) 4912 R11 79.2 Chromaticity Chroma x 0.3484 R12 55.4 Chromaticity Chroma y 0.3622 R13 80.6 Chromaticity Chroma u 0.2096 R14 95.5 Chromaticity Chroma v 0.3268 Duv 0.0039 Chromaticity Chroma u 0.2096 Chromaticity Chroma v 0.4902 Table 2: Test data per Sphere-Spectroradiometer Method Note: According to CIE 1976 (u,v ) diagram, u = u = 4x/(-2x+12y+3), v = 3v/2 = 9y/(-2x+12y+3). Prepared by: Leading Testing Laboratories Page 5 of 9

Spectral Power Distribution - Sphere Spectroradiometer Method Chart 1: Spectral Power Distribution Spectral Distribution over Visible Wavelength WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) 380 3.65E-04 485 1.24E-02 590 3.19E-02 695 4.60E-03 385 3.84E-04 490 1.40E-02 595 3.14E-02 700 3.96E-03 390 4.19E-04 495 1.63E-02 600 3.06E-02 705 3.41E-03 395 4.47E-04 500 1.90E-02 605 2.96E-02 710 2.94E-03 400 5.08E-04 505 2.14E-02 610 2.86E-02 715 2.52E-03 405 6.51E-04 510 2.35E-02 615 2.73E-02 720 2.17E-03 410 9.25E-04 515 2.52E-02 620 2.56E-02 725 1.85E-03 415 1.45E-03 520 2.63E-02 625 2.40E-02 730 1.60E-03 420 2.53E-03 525 2.72E-02 630 2.22E-02 735 1.37E-03 425 4.48E-03 530 2.81E-02 635 2.04E-02 740 1.18E-03 430 7.90E-03 535 2.86E-02 640 1.86E-02 745 1.01E-03 435 1.33E-02 540 2.94E-02 645 1.68E-02 750 8.62E-04 440 2.32E-02 545 2.99E-02 650 1.51E-02 755 7.44E-04 445 4.14E-02 550 3.02E-02 655 1.35E-02 760 6.36E-04 450 5.12E-02 555 3.09E-02 660 1.20E-02 765 5.52E-04 455 3.79E-02 560 3.13E-02 665 1.06E-02 770 4.80E-04 460 2.71E-02 565 3.18E-02 670 9.27E-03 775 4.14E-04 465 2.18E-02 570 3.19E-02 675 8.11E-03 780 3.58E-04 470 1.58E-02 575 3.21E-02 680 7.07E-03 475 1.24E-02 580 3.21E-02 685 6.15E-03 480 1.19E-02 585 3.22E-02 690 5.34E-03 Table 3: Spectral Power Distribution Numerical Data per Sphere - Spectroradiometer Method Prepared by: Leading Testing Laboratories Page 6 of 9

Chromaticity Diagram - Sphere Spectroradiometer Method Tristimulus values(x, y) : (0.3484, 0.3622) Chart 2: Chromaticity Diagram per Sphere - Spectroradiometer Method Note: The location on the diagram of the tristimulus coordinates are indicated by the blue diamond. Prepared by: Leading Testing Laboratories Page 7 of 9

Nominal CCT Quadrangles Sphere Spectroradiometer Method Chart 3: Plot of Lamp x/y coordinates on CIE 1931 Chromaticity Diagram Prepared by: Leading Testing Laboratories Page 8 of 9

EQUIPMENT LIST Test Equipment Model Equipment No. Calibration Date Calibration Due date Integrate Sphere system 2M HZTE015-01 Jul. 27, 2016 Jul. 26, 2017 Digital Power Meter WT210 HZTE008-01 Jul. 27, 2016 Jul. 26, 2017 AC Power Supply PCR 500L HZTE001-07 Jul. 27, 2016 Jul. 26, 2017 DC Power Supply 6154 HZTE004-04 Jul. 27, 2016 Jul. 26, 2017 Temperature and humidity recorder JR900 HZTE018-01 Jul. 27, 2016 Jul. 26, 2017 Standard source SCL-1400 HZTE012-02 Jul. 27, 2016 Jul. 26, 2017 TEST METHODS Table 4: Test Equipment List Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed. Sphere-Spectroradiometer Method- Photometric and Electrical Measurements A Labsphere Model CDS 2100 Spectroradiometer and Two Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. The coating reflectance of each sphere is 98%. The measure geometry is 4π. Self-absorption correction is conducted in testing. Bandwidth of spectroradiometer is 350nm-1050nm. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The standard reference of the integrated sphere system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Standards and Technology. The uncertainty of integrating sphere system reported in this document is expended uncertainty is 1.06% with a coverage factor k=2. *** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report shall not be copied except in full and published as advertisement. Prepared by: Leading Testing Laboratories Page 9 of 9