Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation

Similar documents
Fast Bunch Profile Monitoring with THz Spectroscopy of Coherent Radiation at FLASH.

FLASH Upgrade. Decrease wavelength and/or increase brilliance

Demonstration of exponential growth and saturation at VUV wavelengths at the TESLA Test Facility Free-Electron Laser. P. Castro for the TTF-FEL team

Spectral Phase Modulation and chirped pulse amplification in High Gain Harmonic Generation

FLASH 2. FEL seminar. Charge: 0.5 nc. Juliane Rönsch-Schulenburg Overview of FLASH 2 Hamburg,

Electro-Optic Longitudinal Bunch Profile Measurements at FLASH: Experiment, Simulation, and Validation

FLASH performance after the upgrade. Josef Feldhaus

Nonintercepting Diagnostics for Transverse Beam Properties: from Rings to ERLs

Photon Diagnostics. FLASH User Workshop 08.

Introduction to the Physics of Free-Electron Lasers

Development of a high-power coherent THz sources and THz-TDS system on the basis of a compact electron linac

On-line spectrometer for FEL radiation at

THz Pump Beam for LCLS. Henrik Loos. LCLS Hard X-Ray Upgrade Workshop July 29-31, 2009

FLASH: Status and upgrade

Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at DESY

Outline of the proposed JLAMP VUV/soft X-ray FEL and the challenges for the photon beamlines and optics

FLASH at DESY. FLASH. Free-Electron Laser in Hamburg. The first soft X-ray FEL operating two undulator beamlines simultaneously

Nuclear Instruments and Methods in Physics Research A

Advanced Beam Instrumentation and Diagnostics for FELs

Seeding, Controlling and Benefiting from Microbunching Instability

FLASH II. FLASH II: a second undulator line and future test bed for FEL development.

LCLS Injector Diagnostics. Henrik Loos. Diagnostics overview Transverse Beam Properties Longitudinal Beam Properties

Status of the Electron Beam Transverse Diagnostics with Optical Diffraction Radiation at FLASH

Coherent Synchrotron Radiation in the ANKA Storage Ring

Feedback Requirements for SASE FELS. Henrik Loos, SLAC IPAC 2010, Kyoto, Japan

Commissioning the Echo-Seeding Experiment ECHO-7 at NLCTA

Bioimaging of cells and tissues using accelerator-based sources

Electro-optic Spectral Decoding Measurements at FLASH

SUPPLEMENTARY INFORMATION

Attosecond Diagnostics of Muti GeV Electron Beams Using W Band Deflectors

BEAM DIAGNOSTICS AT THE VUV-FEL FACILITY

C. Addi'onal FEL topics

arxiv:physics/ v1 [physics.acc-ph] 18 Jul 2003

Instructions for the Experiment

Observational Astronomy

R&D Toward Brighter X-ray FELs

LUCX - THZ PROGRAM: OVERVIEW AND PROSPECTS

12/08/2003 H. Schlarb, DESY, Hamburg

3 General layout of the XFEL Facility

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

HIGHER ORDER MODES FOR BEAM DIAGNOSTICS IN THIRD HARMONIC 3.9 GHZ ACCELERATING MODULES *

Note on the LCLS Laser Heater Review Report

COTR Diagnostics and Sources of Microbunching. Alex Lumpkin, Fermilab Presented at Microbunching Instability Workshop College Park, MD April 13, 2012

SCS Optical Laser Delivery

Spectral characterization of the FERMI pulses in the presence of electron-beam phase-space modulations

Introduction Fundamentals of laser Types of lasers Semiconductor lasers

Progress of the TEO experiment at FLASH

Eliminating the microbunching-instabilityinduced sideband in a soft x-ray self-seeding free-electron laser

Shintake Monitor Nanometer Beam Size Measurement and Beam Tuning

THz Imaging by a Wide-band Compact FEL

FLASH II: an Overview

Wir schaffen Wissen heute für morgen

Photon Diagnostics for the VUV-FEL

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

Status of the Project

Review of Coherent SASE Schemes

OVERVIEW OF SEEDING METHODS FOR FELS

Extending the photon energy coverage of an x-ray self-seeding FEL. via the reverse taper enhanced harmonic generation technique

Seeding at LCLS FEL. J. Welch, (SLAC) J. Welch (SLAC), Joint DESY and University of Hamburg Accelerator Physics Seminar, Feb. 5, 2013, DESY Hamburg

Zhirong Huang. May 12, 2011

The Potential for the Development of the X-Ray Free Electron Laser

2 TTF/FLASH in the XFEL context

arxiv: v1 [physics.acc-ph] 6 Apr 2016

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

Outline. Motivation Experimental Set-Up Theory behind the set-up Results Acknowledgements

A Narrow-Band Tunable Diode Laser System with Grating Feedback

NIST EUVL Metrology Programs

Undulator K-Parameter Measurements at LCLS

Wisconsin FEL Initiative

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

FLASH Operation at DESY From a Test Accelerator to a User Facility

Review of Coherent SASE Schemes

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

R. J. Jones Optical Sciences OPTI 511L Fall 2017

ELECTRON BEAM INSTRUMENTATION TECHNIQUES USING COHERENT RADIATION

Terahertz spectroscopy measurements

BEAM ECHO EFFECT FOR GENERATION OF SHORT-WAVELENGTH RADIATION

Order Overlap. A single wavelength constructively interferes in several directions A given direction can receive multiple wavelengths.

LCLS-II-HE Instrumentation

Detection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

PhysicsAndMathsTutor.com 1

Characterization of Chirped volume bragg grating (CVBG)

Optical coherence tomography

A new picosecond Laser pulse generation method.

DCS laser for Thomson scattering diagnostic applications

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Performance Evaluation of the Upgraded BAMs at FLASH

1-Å FEL Oscillator with ERL Beams

Far field intensity distributions of an OMEGA laser beam were measured with

membrane sample EUV characterization

Optimization of TW XFELs. C. Emma Physics and applications of high efficiency free electron lasers workshop April 11 UCLA

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Investigations towards an optical transmission line for longitudinal phase space measurements at PITZ

Vertical External Cavity Surface Emitting Laser

Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS

Performance of the SASE3 monochromator equipped with a provisional short grating. Variable line spacing grating specifications

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

High Energy Non - Collinear OPA

Sub-ps (and sub-micrometer) developments at ELETTRA

Transcription:

Infrared Single Shot Diagnostics for the Longitudinal Profile of the Electron Bunches at FLASH Disputation Hossein Delsim-Hashemi Tuesday 22 July 2008

7/23/2008 2/ 35 Introduction m eb c 2 3 2 γ ω = + + = 2 2 2 2 2 1 2 θ γ γ λ λ K u l + = 2 1 2 2 2 K u l γ λ λ 1 N 2 I I N = Free electron laser

Introduction 7/23/2008 3/ 35 Very large number of electrons to be confined very close together Hard to achieve in sub-micrometer wavelengths Modulating a relatively long electron beam into equally spaced bunch-lets automatically inside the undulator. UV and X-ray range High gain FEL FEL Special version starting from noise: Self-Amplified Spontaneous Emission (SASE) Seeding the electron bunches by an external laser inside undulator which is tuned to the seed laser wavelength.

How it works? λ u K λ ph = 1 2 + 2γ 2 2 electron beam photon beam Undulator Undula tor beam dump log( radiation power ) distance Power saturation distance 7/23/2008 4/ 35

SASE FEL challenges 7/23/2008 5/ 35 Electron beam parameters needed: Gain Length: L g = 1 3 3 2 2mcγ σ r λu 2 ˆ μ0ek I 1 3 Beam transverse size σ 50μm r Peak current inside bunch Î> 1 ka

Bunch compression 7/23/2008 6/ 35

Courtesy: Martin Dohlus t [ fs 7/23/2008 7/ 35 ]

Has to be diagnosed. How? 7/23/2008 8/ 35 An ideal longitudinal diagnostics tool should be single shot (to monitor shot to shot fluctuations) broad-band, and with high resolution Additional requirements would be: easy to operate and maintain compact and easy to incorporate in different parts of the machine operating independent of machine parameter changes Coherent radiation diagnostics

Coherent Radiation 7/23/2008 9/ 35 F ( ω) = ~ ρ( t)exp( iωt) dt long bunch normalized line-charge density dun dω = N 2 F long 2 du ( ω) 1 d ω ( ω, γ, source) spectral energy density (only coherent term)

Transition Radiation 7/23/2008 10 / 35 Ginzburg-Frank spatial distribution for the backward transition radiation by a single electron (far-field and infinite screen). The angle against backward direction is shown by θ. 1 At = the maximum intensity appears. θ γ

7/23/2008 11 / 35 Transition Radiation (finite screen size) (Transition radiation of an electron bunch is described based on : TESLA report 2005-15, S. Casalbuoni et al.) TR energy per frequency interval f = 1 GHz that is emitted by an electron with γ = 1000 is plotted as a function of the TR screen radius a. 2 e (lnγ + ln 2 0.5) 2 π ε c 2 0

7/23/2008 12 / 35 FLASH layout and infrared radiation beam-lines Terahertz and Optical SYnchrotron radiation LABoratory CTR140 TOSYLAB Circular diffraction radiator Slit diffraction radiator full screen transition radiation Off-axis screen transition radiation (kicked bunch) Bunch compressors IR Undulator

THz-Transport and THz-Beamline (CTR140) 7/23/2008 13 / 35

Transverse profile 7/23/2008 14 / 35 Horizontal pol. 50 µm wavelength

What type of spectrometer? Why grating spectrometers? Why not commercial grating-spectrometers? Three grating turret 7/23/2008 15 / 35

Reflectance gratings 7/23/2008 16 / 35

Efficiencies and distribution 7/23/2008 17 / 35 S pol.

Proof of principle experiment 7/23/2008 18 / 35

Staging 7/23/2008 19 / 35

Collecting optics 7/23/2008 20 / 35

7/23/2008 21 / 35

Next achievements 7/23/2008 22 / 35 Courtesy: B. Schmidt 1- Ring-mirror 2- Collecting cones 3- Flat mirror holders

Two-stage multi-channel spectrometer 7/23/2008 23 / 35 1- THz-filters (remote controlled) 2- Polarizer (remote controlled) 3- Reflectance grating stage 4- Transmission grating stage 5- Reflectance gratings holder and remote controlled mover 6- Transmission gratings holder and remote controlled mover 7- Pyro-camera 8- Parabolic mirror and its linear mover

ACC1 phase scan 7/23/2008 24 / 35

ACC1 phase scan 7/23/2008 25 / 35

ACC1 phase scan 7/23/2008 26 / 35

MCP-CTR spectrum correlation 7/23/2008 27 / 35

GMD-CTR spectrum correlation More? 7/23/2008 28 / 35

Pyro-electric detector response 7/23/2008 29 / 35

Combined broad-band spectrum 7/23/2008 30 / 35

Bunch profile determination 7/23/2008 31 / 35

Bunch profile determination (~700 MeV) 7/23/2008 32 / 35

Bunch profile determination (~500 MeV) 7/23/2008 33 / 35

Summary and outlook Compact two-stage single-shot spectrometer has been designed, constructed and used successfully. Single shot spectroscopy shows shot to shot fluctuations. Characteristics of the longitudinal bunch profile has been determined by Fourier transform methods. Unique profile reconstruction is impossible. Different wavelength ranges of the coherent transition radiation spectra correlate or anti-correlate to the SASE intensity. Structures much shorter than the characteristics length of spike have been observed that may correspond to effects like micro-bunching instability. Lots of useful information are contained in the spectra. The entire spectrometer has to be calibrated to obtain a measured transfer function. The ongoing efforts to setup a multi-stage device composed of more compact detection units could provide a wider wavelength range coverage in a single-shot mode. 7/23/2008 34 / 35

Thank you very much for your attention!