Switch Mode Power Supply

Similar documents
Switch Mode Power Supply

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Fluoro plastic housing for highest chemical and detergent resistance

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Model Number Structure

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

CSM_G7S-_-E_DS_E_7_1

Sensing method Sensing distance Model

E8EB-N0C2B E8EB-N0B2B

MY-GS CSM_MY-GS_DS_E_2_1

E3X-DRT21/SRT21/CIF11

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Phase-sequence Phase-loss Relay

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Model Number Structure

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Model Number Structure

Single-phase Current Relay

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Single-phase Voltage Relay

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Model Number Structure

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Alternate Operation Relay 61F-AN/-APN2

NEW. Better Productivity by Standstill and Low-speed Monitoring

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

S8V-NF (Single-phase 250 V 3 A / 6 A Type)

E6F-CWZ5C (1000P/R) 2M

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Phase-sequence Phase-loss Relay

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

20 Series Power Relays

Model Number Structure

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

LED Displacement Sensor

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

Single-phase Current Relay

Features. 2-Dimensional Code Reader (Fixed Type) V530-R150E-3, EP-3

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Multipoint Temperature Controller

F210 Vision Sensor Flow Menus and Macro Capability

E6F-CWZ5C (1000P/R) 2M

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Specifications 2016-V AC-DC Switching Mode Power Supply NK-200 Series, 200W

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

3. Contact Form A: SPST-NO

Specifications 2019-V AC-DC Switching Mode Power Supply NK-100 Series, 100W

CS Series. Compact, Cost-effective, High Reliability Switching Power Supply. TDK-Lambda Introduces CS series

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

American Power Design, Inc.

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Output configuration Resolution (pulses/rotation) Model. 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600 E6C2-CWZ6C (resolution) 2M

American Power Design, Inc.

Relays with Forcibly Guided Contacts G7SA

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

A 2 W A 2 W Model Number Structure A2W. Model Number Structure Slave button.

American Power Design, Inc.

Precautions in Using the product:

American Power Design, Inc.

E3JM/E3JK. Two Models Contribute to Overall Cost Reduction. Built-in Power Supply Photoelectric Sensor. Ordering Information

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Power Supplies 3. SDN-C Compact DIN Rail Series

Solid-state Timer H3DE

Auto Focus Multi Code Reader

American Power Design, Inc.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Ordering Information. Ratchet Relay G4Q. Model Number Legend

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

STRIDER ESSENTIAL SERIES SST-ST50F-ES230 Power for everything you need

TLP281, TLP281-4 TLP281,TLP281-4 PROGRAMMABLE CONTROLLERS AC/DC-INPUT MODULE PC CARD MODEM(PCMCIA) Pin Configuration (top view)

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Transcription:

New Product Switch Mode Power Supply SJC-ZS SJC-ZS, newly released Power Supply with CE marking. SJC-ZS is our best standard power supply for material cost reduction time saving for installation by DIN-rail mounting CE marking EN 5017 Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. SJC-ZS@@@@@@@-@@@ 1 2 3 4 5 1. Power Ratings 015: 15 W 035: 35 W 050: 50 W 100: 100 W 150: 150 W 350: 350 W 2. Output Voltage 05: 5 V 12: 12 V 24: 24 V 3. Configuration C: Covered 4. Configuration/mounting None: -mounting D: DIN Rail-mounting 5. Input Voltage AC2: 200 to 240 VAC Line-up & Feature SJC-ZS series (15/35/50/100/150/350-W s) Power ratings Voltage 15 W 35 W 50 W 100 W 150 W 350 W 5 V 12 V For More reliability! Conformed to CE marking Expanded operating temperature: 20 C to +70 C Improved Dielectric strength 24 V 1

Ordering Information List of Models in SJC-ZS Series Note: For details on normal stock s, contact your nearest OMRON representative. Comformed standard CE (EN5017) Covered Power Supplies Configuration Input voltage Power ratings Output voltage Output current Models -mounting DIN Railmounting 200 to 240 VAC 15 W 35 W 50 W 100 W 150 W 350 W 15 W 35 W 50 W 100 W 150 W 350 W 5 VDC 3.0 A SJC-ZS01505C-AC2 12 VDC 1.3 A SJC-ZS01512C-AC2 24 VDC 0.7 A SJC-ZS01524C-AC2 5 VDC 7.0 A SJC-ZS03505C-AC2 12 VDC 3.0 A SJC-ZS03512C-AC2 24 VDC 1.5 A SJC-ZS03524C-AC2 5 VDC 10.0 A SJC-ZS05005C-AC2 12 VDC 4.2 A SJC-ZS05012C-AC2 24 VDC 2.1 A SJC-ZS05024C-AC2 5 VDC 20.0 A SJC-ZS10005C-AC2 12 VDC.5 A SJC-ZS10012C-AC2 24 VDC 4.5 A SJC-ZS10024C-AC2 5 VDC 30.0 A SJC-ZS15005C-AC2 12 VDC 12.5 A SJC-ZS15012C-AC2 24 VDC 6.5 A SJC-ZS15024C-AC2 5 VDC 60.0 A SJC-ZS35005C-AC2 12 VDC 29.0 A SJC-ZS35012C-AC2 24 VDC 14.6 A SJC-ZS35024C-AC2 5 VDC 3.0 A SJC-ZS01505CD-AC2 12 VDC 1.3 A SJC-ZS01512CD-AC2 24 VDC 0.7 A SJC-ZS01524CD-AC2 5 VDC 7.0 A SJC-ZS03505CD-AC2 12 VDC 3.0 A SJC-ZS03512CD-AC2 24 VDC 1.5 A SJC-ZS03524CD-AC2 5 VDC 10.0 A SJC-ZS05005CD-AC2 12 VDC 4.2 A SJC-ZS05012CD-AC2 24 VDC 2.1 A SJC-ZS05024CD-AC2 5 VDC 20.0 A SJC-ZS10005CD-AC2 12 VDC.5 A SJC-ZS10012CD-AC2 24 VDC 4.5 A SJC-ZS10024CD-AC2 5 VDC 30.0 A SJC-ZS15005CD-AC2 12 VDC 12.5 A SJC-ZS15012CD-AC2 24 VDC 6.5 A SJC-ZS15024CD-AC2 5 VDC 60.0 A SJC-ZS35005CD-AC2 12 VDC 29.0 A SJC-ZS35012CD-AC2 24 VDC 14.6 A SJC-ZS35024CD-AC2 2

Ratings, Characteristics, and Functions 15-/35-W Models Power ratings 15 W 35 W Item Series name SJC-ZS SJC-ZS Certification CE (EN 5017) CE (EN 5017) Output voltage (VDC) 5 V 12 V 24 V 5 V 12 V 24 V Output current 3.0 A 1.3 A 0.7 A 7.0 A 3.0 A 1.5 A Output Voltage adjustment range (typical) 10% to 10% 10% to 10% Ripple (typical) 70 mv 60 mv 50 mv 40 mv 100 mv 100 mv Startup time (typical) 260 ms 270 ms 300 ms 240 ms 260 ms 300 ms Hold time (typical) 50 ms 65 ms 50 ms 30 ms 35 ms 40 ms Efficiency (typical) 76% 0% 76% 3% 4% Voltage 200 to 240 VAC (15 to 264 VAC) 200 to 240 VAC (15 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) 50/60 Hz (47 to 64 Hz) 50/60 Hz (47 to 64 Hz) Input Additional functions Other Current (typical) 0.22 A 0.5 A Leakage current 1 ma max. 1 ma max. Inrush current (for a cold start at 25 C) (typical) Overload protection 40 A 40 A 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Yes Yes Parallel operation No No Series operation No No Ambient operating temperature *Refer to the derating curve in Engineering Data Dielectric strength ( current: 20 ma) all inputs and outputs all inputs and PE terminals all outputs and PE terminals Vibration resistance * 20 C to 70 C 105% of rated load current, voltage drop, intermittent, automatic reset * 20 C to 70 C 3 kvac for 1 min. 3 kvac for 1 min. 2 kvac for 1 min. 2 kvac for 1 min. 1 kvac for 1 min. 1 kvac for 1 min. 10 to 55 Hz, 0.26-mm single amplitude for 2 h each in X, Y, and Z directions 10 to 55 Hz, 0.26-mm single amplitude for 2 h each in X, Y, and Z directions MTBF 135,000 hrs 135,000 hrs Output indicator Yes (Color: Green) Yes (Color: Green) mounting 36 97 0 mm 3 9 129 mm Dimensions (W H D) DIN Railmounting 46 97 105 mm 46 9 154 mm (See note 3.) mounting 200 g 20 g Weight (typical) DIN Railmounting 370 g 450 g Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25 C. 2. Ripple and noise are measured at a bandwidth of 20 MHz. 3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products). 3

50-/100-W Models Power ratings 50 W 100 W Item Series name SJC-ZS SJC-ZS Certification CE (EN 5017) CE (EN 5017) Output Output voltage (VDC) 5 V 12 V 24 V 5 V 12 V 24 V Output current 10 A 4.2 A 2.1 A 20 A.5 A 4.5 A Voltage adjustment range (typical) 10% to 10% 10% to 10% Ripple (typical) 0 mv 60 mv 50 mv 160 mv 140 mv 150 mv Startup time (typical) 240 ms 260 ms 300 ms 250 ms 270 ms 300 ms Hold time (typical) 35 ms 40 ms 30 ms 50 ms 55 ms 50 ms Efficiency (typical) 75% 3% 77% 1% 7% Input Additional functions Other Voltage 200 to 240 VAC (15 to 264 VAC) 200 to 240 VAC (15 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) 50/60 Hz (47 to 64 Hz) 50/60 Hz (47 to 64 Hz) Current (typical) 0.65 A 1.4 A Leakage current 1 ma max. 1 ma max. Inrush current (for a cold start at 25 C) (typical) Overload protection 40 A 40 A 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Yes Yes Parallel operation No No Series operation No No Ambient operating temperature *Refer to the derating curve in Engineering Data Dielectric strength ( current: 20 ma) all inputs and outputs all inputs and PE terminals all outputs and PE terminals Vibration resistance * 20 C to 70 C 105% of rated load current, voltage drop, intermittent, automatic reset * 20 C to 70 C 3 kvac for 1 min. 3 kvac for 1 min. 2 kvac for 1 min. 2 kvac for 1 min. 1 kvac for 1 min. 1 kvac for 1 min. 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z directions MTBF 135,000 hrs 135,000 hrs Output indicator Yes (Color: Green) Yes (Color: Green) Dimensions (W H D) Weight (typical) mounting DIN Railmounting (See note 3.) mounting DIN Railmounting 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z directions 3 9 129 mm 50 9 159 mm 3 9 159 mm 46 9 154 mm 52 9 16 mm 46 9 16 mm 20 g 440 g 30 g 370 g 450 g 620 g 550 g 540 g Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25 C. 2. Ripple and noise are measured at a bandwidth of 20 MHz. 3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products). 4

150-/350-W Models Power ratings 150 W 350 W Item Series name SJC-ZS SJC-ZS Certification CE (EN 5017) CE (EN 5017) Output Output voltage (VDC) 5 V 12 V 24 V 5 V 12 V 24 V Output current 30 A 12.5 A 4.5 A 60 A 29 A 14.6 A Voltage adjustment range (typical) 10% to 10% 10% to 10% Ripple (typical) 210 mv 210 mv 200 mv 300 mv 240 mv 200 mv Startup time (typical) 250 ms 750 ms 300 ms 700 ms 700 ms 300 ms Hold time (typical) 50 ms 70 ms 60 ms 25 ms Efficiency (typical) 79% 5% 7% 75% 7% 4% Input Additional functions Other Voltage 200 to 240 VAC (15 to 264 VAC) 200 to 240 VAC (15 to 264 VAC) Frequency 50/60 Hz (47 to 63 Hz) 50/60 Hz (47 to 64 Hz) 40/60 Hz (47 to 64 Hz) Current (typical) 2.0 A 4.2 A Leakage current 1 ma max. 1 ma max. Inrush current (for a cold start at 25 C) (typical) Overload protection 40 A 40 A 105% of rated load current, voltage drop, intermittent, automatic reset Overvoltage protection Yes Yes Parallel operation No No Series operation No No Ambient operating temperature *Refer to the derating curve in Engineering Data Dielectric strength ( current: 20 ma) all inputs and outputs all inputs and PE terminals all outputs and PE terminals Vibration resistance * 20 C to 70 C 105% of rated load current, voltage drop, intermittent, automatic reset * 20 C to 70 C 3 kvac for 1 min. 3 kvac for 1 min. 2 kvac for 1 min. 2 kvac for 1 min. 1 kvac for 1 min. 1 kvac for 1 min. 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z directions MTBF 135,000 hrs 135,000 hrs Output indicator Yes (Color: Green) Yes (Color: Green) Dimensions (W H D) Weight (typical) mounting DIN Railmounting (See note 3.) mounting DIN Railmounting 43 9 199 mm 50 9 159 mm 50 115 195 mm 46 9 226 mm 52 9 16 mm 52 115 221 mm 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z directions 560 g 530 g 450 g 7 g 00 g 774 g 750 g 700 g 620 g 946 g 95 g 932 g Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25 C. 2. Ripple and noise are measured at a bandwidth of 20 MHz. 3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products). 5

Block Diagrams AC (L) INPUT AC (N) Fuse Inrush current protection Noise filter Rectifier Smoothing Rectifier/ Smoothing DC OUTPUT Drive control Circuit Overcurrent Overvoltage Voltage Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W SJC-ZS 5 V 12 V 24 V AC (L) INPUT AC (N) Fuse Inrush current protection Noise filter Rectifier Smoothing Rectifier/ Smoothing DC OUTPUT Drive control Circuit Overcurrent Photocoupler Voltage Overvoltage Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W SJC-ZS 5 V 12 V 24 V AC (L) INPUT AC (N) Fuse Inrush current protection Noise filter Rectifier Smoothing Rectifier/ Smoothing DC OUTPUT Drive control Circuit Overcurrent Photocoupler Voltage Overvoltage Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W SJC-ZS 5 V 12 V 24 V AC (L) INPUT AC (N) Fuse Noise filter Inrush current protection Rectifier Smoothing Drive Rectifier/ Smoothing DC OUTPUT Control Circuit Overcurrent Overheat protection Photocoupler Voltage Overvoltage Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W 5 V SJC-ZS 12 V 24 V 6

Engineering Data Derating Curves for SJC-ZS Load rate (%) 120 100 0 A 60 40 20 0-20 -10 0 10 20 30 40 50 60 70 Ambient Temperature ( C) Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the area shown by shading A in the above graph). 2. If there is a derating problem, use forced air-cooling. Terminal Arrangement 15-/35-/50-W Models 100-/150-/350(24 V)-W Models 350(5 V, 12 V)-W Models AC(L) AC(N) AC(L) AC(N) AC(L) AC(N) Note: The SJC-S05024C is shown above. Terminal Cover Fitting Note: 1. The SJC-S10024C is shown above. 2. The rated current for output terminals is 25 A per terminal. Be sure to use multiple terminals simultaneously for current that exceeds the terminal rating. When applying a current of 25 A or more, use at east two terminals each for the positive and negative wires. Note: The SJC-S35005C is shown above. SJC-ZS@@@@@C Models Removing SJC-ZS@@@@@C Models Fitting a a b b (1) (2) (4) In (1) case, please push scratched parts (a, b) on the cover following the arrow In (2) case, please remove the cover following the arrow In case, please remove the cover following the arrow In (4) case, please push scratched parts (a, b) on the cover following the arrow 7

Dimensions -mounting Models (Unit: mm) SJC-ZS015@@C-AC2 (15 W) 3.5 3.5 dia. 5.5 45.5 65±0.5 97±1 36±1 20.5 4.25 4.5 4 dia. 35±0.5 70.5±0.5 7±1 30.5 17.5 4 1 54±0.5 (Depth 2 mm max.) 75±1 24 5±0.5 70.5±0.5 70.5±0.5 6.5±0.5 Note: The screws must not protrude more than 2 mm inside the Power Supply when screw holes provided on the chassis are used. If the dimensions are not correct, the Power Supply may be damaged. SJC-ZS035@@C-AC2 (35 W) SJC-ZS050@@C-AC2 (50 W) 129±1 4 dia. 5.5 33±0.5 34 9.3±1 3±1 4.5 4 dia. 7 32 77±0.5 6.5 29 1 (Depth 2 mm max.) 1±0.5 10.5 15.5 13 5.5±0.5 122.5±0.5 13±0.5 120±0.5

SJC-ZS10005C-AC2 (100 W) Seven, M3 screws Four, M3 screws 50±1 4 dia. 6 4.5 22 120±0.5.7 0±0.5 9 159±1 4 dia. 7 14±0.5 43.5 29 (Depth 2 mm max.) 22 125±0.5 20 13 17.5 26±0.5 4±0.5 152±0.5 26±0.5 14±0.5 SJC-ZS10012C-AC2 (100 W) SJC-ZS10024C-AC2 (100 W) 0±0.5 97.6±1 3±1 4 dia. 6 4.5 22 120±0.5 159±1 4 dia. 7 14±0.5.7 31.5 22 22 125±0.5 (Depth 2 mm max.) 13 13±0.5 16.5 15±0.5 4±0.5 152±0.5 14±0.5 15±0.5 9

SJC-ZS15005C-AC2 (150 W) 62 120±0.5 3.5 43.5 5 4.5 3.5 dia. 6.5 33.5 24.5 3.5 dia. 192.5±0.5 199 190±0.5 3.5 1±0.5 15 0±0.5 33.5 5.5±0.5 9 22 157±0.5 (Depth 2 mm max.) 5.5±0.5 192.5±0.5 190±0.5 SJC-ZS15012C-AC2 (150 W) SJC-ZS15024C-AC2 (150 W) Seven, M3 screws Four, M3 screws 50±1 4 dia. 6 4.5 22 120±0.5.7 0±0.5 9 159±1 4 dia. 7 14±0.5 43.5 29 (Depth 2 mm max.) 22 125±0.5 20 13 17.5 26±0.5 4±0.5 152±0.5 26±0.5 14±0.5 10

SJC-ZS35005C-AC2 (350 W) SJC-ZS35012C-AC2 (350 W) 193.6 Four, M3 145±0.5 Four, M3 0±0.5 115 1.2 0±0.5 50 32. 145±0.5 30 150±0.5 Four, M4 (Depth 2 mm max.) 25±0.5 13 150±0.5 Four, M4 25±0.5 SJC-ZS35024C-AC2 (350 W) 145±0.5 Four, M3 0±0.5 115 0±0.5 17.2 50±1 32. 145±0.5 194. 30 150±0.5 Four, M4 (Depth 2 mm max.) 25±0.5 13 150±0.5 Four, M4 25±0.5 11

DIN Rail-mounting Models SJC-ZS01524CD-AC2 (15 W) 7. 97 46 (10) 7 (15.6) 5.5 mm max. SJC-ZS035@@CD-AC2 (35 W) SJC-ZS050@@CD-AC2 (50 W) 7. 9.3 46 (10) 129 15 5 mm max. SJC-ZS10005CD-AC2 (100 W) 7. 97.5 51.5 (10) 159 (16) 5 mm max. SJC-ZS10012CD-AC2 (100 W) SJC-ZS10024CD-AC2 (100 W) 46 7. (10) 159 (16.1) 5 97.6 mm max. 12

SJC-ZS15005CD-AC2 (150W) W) 7. 9 46 (10) 199 (16) (5) mm max. SJC-ZS15012CD-AC2 (150 W) SJC-ZS15024CD-AC2 (150 W) 7. 97.5 51.5 (10) 159 (16) 5 mm max. SJC-ZS35005CD-AC2 (350 W) SJC-ZS35012CD-AC2 (350 W) 7.5 6. 115 51.5 (12) 193.6 (17.2) SJC-ZS35024CD-AC2 (350 W) 7. 115 51.5 (10) 194. (16) 5 9 mm max. 13

Safety Precautions Refer to Safety Precautions for All Power Supplies. Precautions for Safe Use Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. Connect the ground completely. Electric shock or malfunction may occur if the ground is not connected completely. The service life of the fan is approximately 35,000 hours (at 25 C). The service life varies, however, depending on the ambient temperature or other surrounding environmental conditions such as dust. As a guide, replace the product within two years if it is used at an ambient temperature of 40 C. (For 350-W Models only.) The screws must not protrude more than 2 mm inside the Power Supply when screw holes provided on the chassis are used. Avoid places where the product is subjected to penetration of liquid, foreign substance, or corrosive gas (in particular, sulfide gas or ammonia gas). The rated current for output terminals is 25 A per terminal. Be sure to use multiple terminals simultaneously for current that exceeds the terminal rating. When applying a current of 25 A or more, use at east two terminals each for the positive and negative wires. 14

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. Cat. No. T011-EN-01 In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 56 13 00 Fax: +31 23 56 13 www.industrial.omron.eu