TB-2705 PXI TERMINAL BLOCK FOR ESERIES

Similar documents
SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

SCXI High-Voltage Terminal Block

SCXI High-Voltage Terminal Block

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

SCXI HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK

BNC-2121 Connector Accessory for 660X Devices

FP-DO-400 and cfp-do-400

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

TBX CHANNEL ISOTHERMAL TERMINAL BLOCKINSTALLATION GUIDE

SCC-FV01 Frequency Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

FP-SG-140 AND CFP-SG-140

FP-CTR-500 and cfp-ctr-500

FP-CTR-502 and cfp-ctr-502

FP-RTD-122 AND CFP-RTD-122. Features. FieldPoint Operating Instructions. Eight-Channel Three-Wire RTD and Resistance Input Modules

DAQ. PCI-6110/6111 User Manual. Multifunction I/O Devices for PCI Bus Computers. November 2000 Edition Part Number C-01

NI Channel, Universal Digital Input Module

FP-DO-401 and cfp-do-401

FP-RTD-122 and cfp-rtd-122

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

NI 6624 Calibration Procedure

TBX-1326 HIGH-VOLTAGE TERMINAL BLOCK

NI Channel SPST Electromechanical Relay Module

DAQ. SCC Series User Manual. SCC Series User Manual. December 1999 Edition Part Number D-01

SCC-ACC01 Accelerometer Input Module

FP-DO-403 and cfp-do-403

DAQ. NI 6013/6014 User Manual. NI 6013/6014 User Manual. Multifunction I/O Devices for PCI Bus Computers. October 2002 Edition Part Number A-01

NI Channel, TTL Digital Input/Output Module

SCC-DI01 Isolated Digital Input Module

OPERATING INSTRUCTIONS NI Port DeviceNet Module

NI 6143 Specifications

SCC-CO20 Isolated Current Output Module

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

DAQ. DAQPad -6020E User Manual. Multifunction I/O Devices for USB. DAQPad-6020E User Manual. September 1998 Edition Part Number A-01

NI sbrio-9632/9642 Verification Procedure

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

The SCB-68 is a shielded board with 68 screw terminals for easy connection to National Instruments 68-pin products.

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

NI 6013/6014 Family Specifications

Eight-Channel Thermocouple Input Module

INSTALLATION GUIDE BNC-2120 Connector Accessory for E/M/S Series Devices. Contents

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

Table 2. Differences Between the USB-6008 and USB Feature USB-6008 USB bits differential, 13 bits single-ended Maximum AI Sample Rate,

NI 6731/6733 Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, ±10 V, 16-Bit Simultaneous Analog Input Module. ni.com/manuals

NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

SC-2040 User Manual. Eight-Channel Simultaneous Sample-and-Hold Accessory. September 1994 Edition. Part Number A-01

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI 6023E/6024E/6025E Family Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

NI DAQPad -6020E Family Specifications

TBX-68S Isothermal Terminal Block

DAQ. DAQCard E Series User Manual. Multifunction I/O Cards for PCMCIA. March 1999 Edition Part Number C-01

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

NI PXI-2521 Specifications 40-Channel DPST Relay Module

Specifications for the NI PXI/PCI-6552/6551

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

NI PXI-2532 Specifications

Specifications. PCI Bus. Analog Input Input Characteristics

NI PXI-2520 Specifications 80-Channel SPST Relay Module

The following conventions apply to this document:

DAQ. PXI E Series User Manual. Multifunction I/O Boards for PXI and CompactPCI Bus Computers. January 1999 Edition Part Number C-01

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

KickStart Instrument Control Software Datasheet

SCXI MHz Quad 8x1 50 Ω Multiplexer

NI 6040E Family Specifications

NI PXI-2557 Specifications

Getting Started with the LabVIEW DSP Module

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

NI PXI Contents. About These Specifications DEVICE SPECIFICATIONS GHz Dual Transfer Switch 50 Ω Relay Module

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

30 A AC/DC Current Probe TCP0030A Datasheet

Analog Characteristics

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

NI SCXI Specifications

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

NI PXI/PXIe-2529 Specifications

NI PXI-2555 Specifications

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

NI PXI-4461 Specifications

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

1.5 GHz Active Probe TAP1500 Datasheet

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

NI PXI-2530 Specifications

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

OPERATING INSTRUCTIONS NI Channel, 24-Bit, Universal Analog Input Module

SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

PRODUCT DATA. Sound Intensity Calibrator Type 4297

NI PXI/PXIe-2540 Specifications

NI PXI/PXIe-2532 Specifications

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Transcription:

INSTALLATION GUIDE TB-2705 PXI TERMINAL BLOCK FOR ESERIES AND WAVEFORM GENERATION DEVICES Introduction This installation guide describes how to install and connect signals to the TB-2705 terminal block for use with PXI E Series and waveform generation devices. The TB-2705 is a terminal block assembly consisting of a printed circuit board, 62 screw terminals, and a plastic enclosure with a strain relief. The terminal block assembly connects directly to the front panel of National Instruments E Series and waveform generation devices, eliminating the need for an external cable. The TB-2705 allows you to easily connect analog input, analog output, counter-timer, and digital I/O signals to your National Instruments device. The 62 screw terminals allow access to every pin on the device with the exception of some digital ground signals that are common to one another. The TB-2705 also has a shielded strain-relief to secure your I/O wires and provide an adequate chassis-ground connection. What You Need to Get Started You need the following to set up and use your terminal block: TB-2705 Terminal Block Assembly TB-2705 PXI Terminal Block for E Series and Waveform Generation Devices Installation Guide One of the following: PXI E Series device waveform generation device with a 68-pin I/O connector PXI, National Instruments, and ni.com are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 322909A-01 Copyright 2000 National Instruments Corp. All rights reserved. November 2000

One of the following: PXI E Series User Manual waveform generation device user manual 0.10 in. slotted screwdriver Number 1 Phillips-head screwdriver Wire cutters Wire insulation stripper One of the following: E Series device overlay Waveform generation device overlay Conventions The following conventions are used in this guide: <> Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name for example, DBIO<3..0>. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. italic Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply. Safety Information Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. Do not operate damaged equipment. The safety protection features built into this device can become impaired if the device becomes damaged in any way. If the device is damaged, turn the device off and do not use it until service-trained personnel can check its safety. If necessary, return the device to National Instruments for service and repair to ensure that its safety is not compromised. TB-2705 PXI Terminal Block 2 ni.com

Do not operate this equipment in a manner that contradicts the information specified in this document. Misuse of this equipment could result in a shock hazard. Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised. You must insulate all of your signal connections to the highest voltage with which the TB-2705 can come in contact. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal ratings on the terminal block can create a shock or fire hazard, or can damage any or all of the boards connected to the host computer, and the terminal block. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. Clean the module and accessories by brushing off light dust with a soft non-metallic brush. Remove other contaminants with a stiff non-metallic brush. The unit must be completely dry and free from contaminants before returning it to service. Signal Descriptions Table 1 describes the E Series signals available on the TB-2705. Table 2 describes the waveform generation signals. Table 1. TB-2705 Terminal Block E Series Signal Descriptions Signal Name Reference Direction Description AIGND Analog Input Ground These terminals are the reference point for single-ended measurements in RSE configuration and the bias current return point for differential measurements. All three ground references AIGND,, and are connected together on your E Series device. ACH<0..15> AIGND Input Analog Input Channels 0 through 15 You can configure each channel pair, ACH<i, i+8> (i = 0..7), as either one differential input or two single-ended inputs. National Instruments Corporation 3 TB-2705 PXI Terminal Block

Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description AISENSE AIGND Input Analog Input Sense This terminal serves as the reference node for any of channels ACH <0..15> in NRSE configuration. DAC0OUT Analog Channel 0 This terminal supplies the voltage output of analog output channel 0. DAC1OUT Analog Channel 1 This terminal supplies the voltage output of analog output channel 1. EXTREF Input External Reference This terminal is the external reference input for the analog output circuitry. Analog Ground The analog output voltages are referenced to these terminals. All three ground references AIGND,, and are connected together on your E Series device. Digital Ground These pins supply the reference for the digital signals at the I/O connector as well as the +5 VDC supply. All three ground references AIGND,, and are connected together on your E Series device. DIO<0..7> Input or Digital I/O Signals DIO 6 and 7 can control the up/down signal of general-purpose counters 0 and 1, respectively. +5 V +5 VDC Source These terminals are fused for up to 1 A of +5 V supply. The fuse is self-resetting. TB-2705 PXI Terminal Block 4 ni.com

Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description SCANCLK Scan Clock This terminal pulses once for each A/D conversion in the scanning modes when enabled. The low-to-high edge indicates when you can remove the input signal from the input or switched to another signal. EXTSTROBE External Strobe This output is used for controlling SCXI modules. PFI0/TRIG1 Input PFI0/Trigger 1 As an input, this is either one of the programmable function inputs (PFIs) or the source for the hardware analog trigger. For more information on PFI signals, see the PXI E Series User Manual. As an output, this is the TRIG1 signal. In posttrigger data acquisition sequences, a low-to-high transition indicates the initiation of the acquisition sequence. In pretrigger applications, a low-to-high transition indicates the initiation of the pretrigger conversions. PFI1/TRIG2 Input PFI1/Trigger 2 As an input, this is one of the PFIs. As an output, this is the TRIG2 signal. In pretrigger applications, a low-to-high transition indicates the initiation of the posttrigger conversions. TRIG2 is not used in posttrigger applications. PFI2/CONVERT Input PFI2/Convert As an input, this is one of the PFIs. As an output, this is the CONVERT* signal. A high-to-low edge on CONVERT* indicates the start of an A/D conversion. National Instruments Corporation 5 TB-2705 PXI Terminal Block

PFI3/GPCTR1_ SOURCE Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description Input PFI3/Counter 1 Source As an input, As an output, this is the GPCTR1_SOURCE signal. This signal reflects the actual source connected to general-purpose counter 1. PFI4/GPCTR1_GATE Input PFI4/Counter 1 Gate As an input, As an output, this is the GPCTR1_GATE signal. This signal reflects the actual gate signal connected to the general-purpose counter 1. GPCTR1_OUT Counter 1 This is the general-purpose counter 1 output. PFI5/UPDATE Input PFI5/Update As an input, this is one of the PFIs. As an output, this is the UPDATE* signal. A high-to-low edge on UPDATE* indicates that the analog output primary group is updating. PFI6/WFTRIG Input PFI6/Waveform Trigger As an input, As an output, this is the WFTRIG signal. In timed analog output sequences, a low-to-high transition indicates the initiation of the waveform generation. PFI7/STARTSCAN Input PFI7/Start of Scan As an input, this is one of the PFIs. As an output, this is the STARTSCAN signal. This pin pulses once at the start of each analog input scan in the interval scan. A low-to-high transition indicates the start of the scan. TB-2705 PXI Terminal Block 6 ni.com

PFI8/GPCTR0_ SOURCE Table 1. TB-2705 Terminal Block E Series Signal Descriptions (Continued) Signal Name Reference Direction Description Input PFI8/Counter 0 Source As an input, As an output, this is the GPCTR0_SOURCE signal. This signal reflects the actual source connected to the general-purpose counter 0. PFI9/GPCTR0_GATE Input PFI9/Counter 0 Gate As an input, As an output, this is the GPCTR0_GATE signal. This signal reflects the actual gate signal connected to the general-purpose counter 0. GPCTR0_OUT Counter 0 This is the general-purpose counter 0 output. FREQ_OUT Frequency This output is from the frequency generator output. Table 2. TB-2705 Terminal Block Waveform Generation Signal Descriptions Signal Name Reference Direction Description Analog Ground The analog output voltages are referenced to this node. DAC<0..7>OUT Analog Channels 0 through 7 These pins supply the voltage output of the respective channel. Digital Ground This pin supplies the reference for the digital signals at the I/O connector as well as the reference for the +5 VDC supply. DIO<0..7> Input or Digital I/O Signals DIO6 and 7 can control the up/down signal of general-purpose counters 0 and 1, respectively. National Instruments Corporation 7 TB-2705 PXI Terminal Block

Table 2. TB-2705 Terminal Block Waveform Generation Signal Descriptions (Continued) Signal Name Reference Direction Description +5 V +5 VDC Source These pins are fused for up to 1 A of +5 V supply. The fuse is self-resetting. EXTREF Input External Reference This is the external reference input for the analog output circuitry. EXTSTROBE* External Strobe This output is used for controlling SCXI modules. PFI0 Input PFI0 As an input, this is one of the Programmable Function Inputs (PFIs). For more information on PFI signals, see the 6711/6713/6715 User Manual. You cannot use PFI0 as an output. PFI1 Input PFI1 As an input, this is one of the PFIs. You cannot use PFI1 as an output. PFI2 Input PFI2 As an input, this is one of the PFIs. You cannot use PFI2 as an output. PFI3/GPCTR1_SOURCE Input PFI3/Counter 1 Source As an input, As an output, this is the GPCTR1_SOURCE signal. This signal reflects the actual source connected to the general-purpose counter 1. PFI4/GPCTR1_GATE Input PFI4/Counter 1 Gate As an input, As an output, this is the GPCTR1_GATE signal. This signal reflects the actual gate signal connected to the general-purpose counter 1. GPCTR1_OUT Counter 1 This is the general-purpose counter 1 output. TB-2705 PXI Terminal Block 8 ni.com

Table 2. TB-2705 Terminal Block Waveform Generation Signal Descriptions (Continued) Signal Name Reference Direction Description PFI5/UPDATE* Input PFI5/Update As an input, this is one of the PFIs. As an output, this is the UPDATE* signal. A high-to-low edge on UPDATE* indicates that the analog output waveform generation group is being updated. PFI6/WFTRIG Input PFI6/Waveform Trigger As an input, As an output, this is the WFTRIG signal. In timed analog output sequences, a low-to-high transition indicates the initiation of the waveform generation. PFI7 Input PFI7 As an input, this is one of the PFIs. You cannot use PFI7 as an output. PFI8/GPCTR0_SOURCE Input PFI8/Counter 0 Source As an input, As an output, this is the GPCTR0_SOURCE signal. This signal reflects the actual source connected to the general-purpose counter 0. PFI9/GPCTR0_GATE Input PFI9/Counter 0 Gate As an input, As an output, this is the GPCTR0_GATE signal. This signal reflects the actual gate signal connected to the general-purpose counter 0. GPCTR0_OUT Counter 0 This is the general-purpose counter 0 output. FREQ_OUT Frequency This is the frequency generator output. National Instruments Corporation 9 TB-2705 PXI Terminal Block

Connecting the Signals See your PXI E Series User Manual or waveform generation device user manual for examples of how to connect your signals. Refer to Figure 1 as you perform the following steps to connect signals to your terminal block. 1 3 2 4 5 6 7 8 4 9 1 Cover 2 Cover Screws (Captive) 3 Strain-Relief Bar 4 Chassis Connection Screws 5 Ground Lug Screw 6 Ground Lug 7 Chassis Ground Tab 8 Connection to PXI Module 9 Strain-Relief Screws Figure 1. TB-2705 Parts Locator Diagram TB-2705 PXI Terminal Block 10 ni.com

1. Remove the terminal block cover by unscrewing the two cover screws using the 0.10 in. slotted screwdriver. Note Your kit contains overlays for both E Series and waveform generation devices. Use the appropriate overlay for your application. PIN# SIGNAL PIN# SIGNAL 30 63 67 60 26 64 32 19 52 17 53 9 51 49 47 45 10 14 40 38 3 36 ACH3 ACH11 AIGND ACH5 ACH13 AIGND AIGND DIO4 DIO0 DIO1 DIO5 DIO2 DIO3 EXTSTROBE PFI1/TRIG2 +5V GPCTR1_OUT PFI7/STARTSCAN PFI9/GPCTR0_GATE PIN# 28 61 59 62 25 58 27 21 20 55 16 48 35 11 43 41 6 4 SIGNAL ACH4 ACH12 AIGND AISENSE ACH6 ACH14 AIGND DAC1OUT EXTREF DIO6 DIO7 PFI0/TRIG1 PFI2/CONVERT PFI4/GPCTR1_GATE PFI5/UPDATE 68 34 29 33 66 24 65 31 56 57 23 22 54 8 46 50 42 18 5 37 2 1 ACH0 ACH8 AIGND ACH1 ACH9 AIGND ACH2 ACH10 AIGND ACH7 ACH15 DAC0OUT +5V SCANCLK PFI3/GPCTR1_SOURCE PFI6/WFTRIG PFI8/GPCTR0_SOURCE GPCTR0_OUT FREQ_OUT Figure 2. E Series Device Overlay National Instruments Corporation 11 TB-2705 PXI Terminal Block

30 68 NC 63 34 67 28 29 60 61 33 NC 26 59 66 64 62 NC 24 32 25 65 19 58 31 52 27 56 17 21 57 53 20 23 9 55 22 51 16 54 49 48 8 47 35 46 NC 45 11 50 10 43 42 14 41 18 40 6 5 38 4 37 3 2 36 1 PIN# SIGNAL PIN# SIGNAL 30 63 67 60 26 64 32 19 52 17 53 9 51 49 47 45 10 14 40 38 3 36 DAC6 OUT DAC4OUT DIO4 DIO0 DIO1 DIO5 DIO2 DIO3 EXTSTROBE PFI1 +5V GPCTR1_OUT PFI7 PFI9 PIN# 28 61 59 62 25 58 27 21 20 55 16 48 35 11 43 41 6 4 SIGNAL DAC5OUT AO GND AO GND NC DAC3OUT DAC1OUT EXTREF DIO6 DIO7 PFI0 PFI2 PFI4 PFI5 68 34 29 33 66 24 65 31 56 57 23 22 54 8 46 50 42 18 5 37 2 1 NC AO GND AO GND NC DAC7OUT DAC2OUT DAC0OUT +5V NC PFI3 PFI6 PFI8 GPCTR0_OUT FREQ_OUT Figure 3. Waveform Generation Device Overlay 2. Apply the label to the inside of the top cover as shown in Figure 4. This label is a pin number to signal name reference. Each overlay has an adhesive backing for adhering the overlay to the top cover. PIN# SIGNAL PIN# SIGNAL DAC6 OUT PIN# SIGNAL AO GND DAC5OUT AO GND DAC4OUT AO GND AO GND DAC3OUT DAC7OUT DIO4 DIO0 DIO1 DAC1OUT DAC2OUT EXTREF DAC0OUT DIO5 DIO6 DIO2 DIO7 +5V DIO3 EXTSTROBE PFI0 PFI1 PFI2 +5V PFI4 GPCTR1_OUT PFI5 PFI6 PFI7 PFI9 GPCTR0_OUT FREQ_OUT PFI3 PFI8 Figure 4. Applying the Overlay TB-2705 PXI Terminal Block 12 ni.com

Installing the Terminal Block 3. Loosen or remove the strain-relief bar by loosening the two strain-relief screws. 4. Use wire cutters and wire insulation strippers to strip no more than 7 mm of insulation from the wire ends. 5. Loosen the screws in the screw terminals with the 0.10 in. slotted screwdriver. 6. Insert the stripped wires into the screw terminals. Tighten the screws with the 0.10 in. slotted screwdriver. No bare wire should extend past the screw terminal. Exposed wire increases the risk of short circuits and failures. 7. Tighten or replace the strain-relief screws. 8. Replace the terminal block cover and tighten the cover screws. Refer to Figure 5 as you perform the following steps to connect the terminal block to the PXI module I/O connector. Caution The connectors of both the PXI module and the terminal block are polarized. You can attach them in only one way. Do not force the terminal block when inserting it into or removing it from the PXI module I/O connector. 1. Install the PXI module into the chassis and tighten the two module screws. You must install the TB-2705 terminal block on the PXI module after the module is installed in the chassis. 2. Guide the terminal block onto the switch module connector. 3. Tighten the two terminal block mounting screws. National Instruments Corporation 13 TB-2705 PXI Terminal Block

2 3 1 2 3 4 5 6 1 7 8 1 Terminal Block Mounting Screws 2 PXI Chassis 3 PXI Module Connector Figure 5. Connecting the TB-2705 to an E Series or Waveform Generation Device Caution The TB-2705 is not designed for input voltages greater than 42 V, even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 42 V can damage the TB-2705, any device connected to it, and the host computer. Overvoltage can also cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse. TB-2705 PXI Terminal Block 14 ni.com

Specifications This section lists the specifications of the TB-2705. These specifications are typical at 25 C unless otherwise specified. Input/ Physical See the documentation of your E Series or waveform generation device to determine the input/output specifications for your application. Dimensions... 8.4 by 10.7 by 2.0 cm (7.5 by 4.125 by 1.38 in.) I/O connector... One 68-position female connector Environment Operating temperature... 0 to 50 C Storage temperature... 20 to 70 C Relative humidity... 10 to 90% noncondensing Safety Designed in accordance with IEC61010-01, EN 61010-1, UL 3111-1, and CAN/CSA C22.2 No.1010.1 for electrical measuring and testing equipment. For use at altitudes up to 2000 meters. Installation Category II Pollution Degree 2 Electromagnetic Compatibility EMC/EMI... CE, C-Tick and FCC Part 15 (Class A) Compliant Electrical emissions... EN 55011 Class A @ 10 meters FCC Part 15A above 1 GHz Electrical immunity... Evaluated to EN 61326:1998, Table 1 Note To ensure full EMC and EMI compliance only operate equipment under test (EUT) with shielded cabling. See the Declaration of Conformity for this product for any additional regulatory compliance information. National Instruments Corporation 15 TB-2705 PXI Terminal Block

Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com Worldwide Support National Instruments has offices located around the world to help address your support needs. You can access our branch office Web sites from the Worldwide Offices section of ni.com. Branch office Web sites provide up-to-date contact information, support phone numbers, e-mail addresses, and current events. If you have searched the technical support resources on our Web site and still cannot find the answers you need, contact your local office or National Instruments corporate. For telephone support in the United States, dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, China 0755 3904939, Denmark 45 76 26 00, Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 30 1 42 96 427, Hong Kong 2645 3186, India 91805275406, Israel 03 6120092, Italy 02 413091, Japan 03 5472 2970, Korea 02 596 7456, Mexico (D.F.) 5 280 7625, Mexico (Monterrey) 8 357 7695, Netherlands 0348 433466, New Zealand 09 914 0488, Norway 32 27 73 00, Poland 0 22 528 94 06, Portugal 351 1 726 9011, Singapore 2265886, Spain 91 640 0085, Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545