Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Similar documents
Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

RMV-122D, RMV-132D ANSI

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. Insulation monitor. Type SIM-Q

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

Automatic synchronising relay

DATA SHEET Selectable AC transducer TAS-311DG

Function. Adjustment. Extra functions included. Modes. Housing

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

TCM-2 Thyristor Control Module DATA SHEET

XN2 - Mains decoupling relay. Manual XN2 (Revision C)

XN2 - Mains decoupling relay

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

XUA1 - AC Voltage and phase balance relay

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Protection and safety SQZ3 phase and sequence relay

27/04/2015

PARAMETER LIST PARAMETER LIST

ENS31 Automatic Isolation Unit Product Description

Current monitor Type C 551

Multi Differential Relay, MDR-2 DESCRIPTION OF OPTIONS


DATA SHEET. Voltmeters and Ammeters,

ENS26 Automatic Isolation Unit Product Description

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

Electronic relays. Monitoring. Monitoring

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

XF2 Frequency Relay. Manual XF2 (Revision A)

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

Moeller Electric Corporation

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Connection of Embedded Generating Plant up to 5MW

DEIF A/S. Description of options. Option H1, CAN open communication Basic Gen-set Controller. Description of option. Functional description

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

SPAF 340 C Frequency Relay

XRN2 - Mains decoupling relay

Generator Protection GENERATOR CONTROL AND PROTECTION

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Installation / Monitoring Technique

Time over/underfrequency relay with protection assemblies

Switching power supplies CP range, Linear power supplies CP-L range. Content

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Supplemental Motor Protection Devices Specifications

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

WD series DIN Rail or Screw Mounted Protective Relays

Phase and neutral overcurrent protection

DATA SHEET. Switchboard instruments,

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

XRW1-4 Mains decoupling relay for wind power systems. Manual XRW1-4 (Revision A)

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

02/11/2015

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Electronic Measuring Relays for Current, Voltage and Overfrequency

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Monitoring Relay MR 50

Installation Instructions and Reference Handbook. Installation instructions

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Synchronisation meters for manual or semiautomatic synchronisation Synchronization Meters SQ0114/SQ0104 Synchronization Meters SQ0214/SQ0204

Voltage Monitors & Phase Monitors

XP2-R Power and Reverse Power Relay

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

Table 6.1 Fault Code List Code indication (Note 3)

Functional Safety Application Guide

22/10/2012

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

3-phase voltage monitoring relay EMR SU31D

Frequency- and voltage monitoring. Technical data G4PF21-1

V AC Meas. current (In): A. Frequency range: Hz. Measuring system:

Capacitor protection relay

Rotational speed controller

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Supplemental Motor Protection Devices Specifications

XD1-T - Transformer differential protection relay

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Single-phase Voltage Relay

Operating Instructions

Time relays. Monitoring relays /

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

Transcription:

Installation and start up instructions G59 Relay Package uni-line 4189340236C (UK) Detection of df/dt (rate of change of frequency R.O.C.O.F.) Detection of vector shift Detection of over- and underfrequency Detection of 3-phase over- and undervoltage Generator disconnection on mains failure Ensures no asynchronous reconnection DEIF A/S LED indication of fault condition LED indication for activated relay 35 mm DIN rail or base mounting DEIF A/S Tel: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com

General Description The G59 package consists of the G59 and RMV-112D protection relays and forms part of a complete DEIF series (the uni-line) of relays for protection and control of generators. The G59 package is applied to protect synchronous generators running in parallel with a high-voltage network (the mains) against damages caused by automatic reconnection to the network and against frequency and voltage fluctuations. 1. G59 Relay 1.1 Description The G59 relay will detect a mains failure, provided that a disconnection at an arbitrary point of the network results in a swift change of the generator frequency (vector shift) and/or a changing frequency overtime, df/dt (R.O.C.O.F). The G59 relay vector shift detects the sudden change of the load angle of the generator, arising the moment the external mains circuit breaker is opened momentarily on mains failure, thus disconnecting the generator. Basically a momentary 5% change of the load results in a 4.5 electr. degr. change of the load angle of the generator. If the vector shift potentiometer of the G59 relay is set to 4 electr. degr., the relay will thus open its mains circuit breaker, ensuring that the generator remains disconnected, until the mains has been restored, and the generator has been resynchronised. The G59 relay df/dt detects a change of frequency over time. If the frequency keeps changing for four periods in a row, exceeding the set-point, the output is activated. The G59 relay over-/underfrequency detects a frequency rising above the selected setpoint. When the limit is exceeded, the relay and LED is activated. 1.2 G59 Label The relay is provided with a label with the following data: Type designation Input voltage DEIF s order ack. No. To be stated when contacting DEIF Mounted voltage module Supply voltage Special calibration (if non-standard calibration is applied) Relay coupling Shown is relay B as a normally de-energised relay, relay C as a normally energised relay. Highest voltage in relation to earth Installation category Note: Latch function is not possible. Distributor s ID No. Filled in by distributor when customizing the unit. Page 2 of 8 Tel. (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com

Installation and start up instructions G59 Package Note: The relay is provided with a 200 ms power-up delay, ensuring correct function of the relay on connection of the auxiliary voltage. Normally energised contacts ( NE ) are not activated (contact does not open/close) until 200 ms after connection of the auxiliary voltage. 1.3 Mounting instructions The G59 is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of two 4-mm screws. Weight: Approx. 0.650 kg. The design of the relay makes mounting of it close to other uni-line units possible, however make sure there are min. 50 mm between the top and bottom of this relay and other relays/units. The DIN rail must always be placed horizontally when several relays are mounted on the same rail. 1.4 Connection diagram A 2A fuse may protect all voltage inputs. The relay is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the relay is not necessary. The G59 may be connected between 2 phases or between 1 phase and neutral. The G59 is to be configured so that the input of the relay corresponds to the connected voltage. 4189340236C (UK)

1.5 Start up instructions 1.5.1 Setting and indication Setting of Vector shift: (2 20 electr. degr.) R.O.C.O.F.: 0 5 Hz/s Overfrequency: (100 110% of f n ) Underfrequency (90 100% of f n ) LED/relay Red LED MAINS FAIL is lit during fault condition. Red LED MAINS FAIL is lit during fault condition. Yellow LED f>, f< is lit during fault condition. Yellow LED f>, f< is lit during fault condition. The delay timer is started, when the contacts connected to the RES input open. It is fixed to 5 s; however, a longer delay is selected if unwanted disconnections occur immediately upon synchronisation of the generator to the mains. During start up, the following setting procedure is recommended: a. Generators operating as emergency generators (much of their power is used locally, and simulating change of generator load is possible): 1. Remove connections to RES 2. Adjust potentiometer marked vector shift / df/dt, so that an opening signal is transmitted to the mains circuit breaker at a load variation of 5 10%. b. Generators of a co-generation plant, supplying all their power to the mains (change of generator load is only with difficulty simulated) 1. Set potentiometer marked vector shift / df/dt to 5/1.5 2. If necessary, adjust this on the basis of practical experience. 1.6 Technical specifications Overload, voltages: 1.2 x Un, continuously 2 x Un for 10 s Load: Frequency range: RESET inputs: Relay contacts: Contact ratings: Contact voltage: Response time: Galv. separation: 2k /V 40 45 65 70Hz Input voltage: 18 250V AC/DC for activated condition Input impedance: 100k 2 change-over switches 250V-8A-2000A (AC), 24V-8A-200W (DC) Max. 250V (AC). Max 150V (DC) <30 ms, vector shift <100 ms, R.O.C.O.F. and frequency Between inputs and outputs: 3250V-50Hz-1 min. Page 4 of 8 Tel. (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com

Installation and start up instructions G59 Package Consumption: Status output: 2. RMV-112D (Aux. supply) 4VA/3.5W Open (fault): 10 30V DC Closed (OK): max. 5mA 2.1 Description This combined undervoltage and overvoltage relay type RMV-112D forms part of a complete DEIF series (the uni-line) of relays for protection and control of generators. 2.2 Label The relay is provided with a label with the following data: Measuring voltage 1 corresp. to 100% on scale Type designation DEIF s order ack. No. To be stated when contacting DEIF Mounted voltage module Supply voltage Coupling 1 (set by DEIF) Relay coupling Shown is relay B as a normally de-energised relay, relay C as a normally energised relay with latch circuit Highest voltage in relation to earth. Installation category (E.g. time delay(s), special calibration) Contact remains locked in alarm position even though the input returns to normal. Latch circuit is reset by disconnecting the supply voltage. Distributor s ID No. Filled in by distributor when customizing the unit. Note 1: Example of a label for an RMV-112D for delta coupling: MEAS VOLTAGE 400/230V MODULE 400V COUPLING DELTA Note : The relay is provided with a 200 ms power-up relay, ensuring correct function of the relay on connection of the auxiliary voltage. Normally energised contacts ( NE ) are not activated (contact does not open/close) until 200 ms after connection of the auxiliary voltage. Likewise, the relay is provided with a 200 ms power-down circuit, ensuring supervision and maintenance of any set point exceeding for 200 ms after disconnection of the auxiliary voltage. 4189340236C (UK)

2.3 Mounting instructions The RMV-112D is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of 2 off 4 mm screws. Weight: ca. 0.650 kg The design of the relay makes mounting of it close to other uni-line units possible, however make sure there are min. 50 mm between the top and bottom of this relay and other relays/units. The DIN rail must always be placed horizontally when several relays are mounted on the same rail. 2.4 Connection diagram Star coupling Delta coupling Please note the difference between relays for delta coupling and for star coupling. The coupling is stated on the label. A 2A fuse may protect all voltage inputs. The relay is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the relay is not necessary. Page 6 of 8 Tel. (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com

Installation and start up instructions G59 Package 2.5 Start up instructions 2.5.1 Setting and indication Setting of Undervoltage set point: (80 100%) of U n Overvoltage set point: (100 120%) of U n Time delay: 0 10 s Hysteresis: (1 10%) of Un LED/relay U< Yellow LED is lit when the input voltage exceeds the set point, but the output contact has not yet been activated. U> Yellow LED is lit when the input voltage exceeds the set point, but the output contact has not yet been activated. The contact is activated and the red LED is lit after the timer has expired. Relay contact is reset when fault voltage equals or is less than the preset hysteresis. The built-in relays of the RMV-112D are activated when the input voltage drops below or exceeds the set points preset on the front of the unit. A suitable hysteresis is selected in relation to the preset set points, e.g. to ensure, that the relay contacts are not reset, until the input voltage is within its nominal range. Example: Nominal voltage range: 95 105V Undervoltage set point: 90% of Un (90V) Overvoltage set point: 110% of U n (110V) Hysteresis: 5% of U n (5V) The relay will now be activated at an undervoltage of 90V and at an overvoltage of 110V, and will be deactivated again when the input voltage is within the range 95 105V. Note: Hysteresis setting is common to undervoltage and overvoltage contacts. When setting the set points on the front of the RMV-112D an accuracy of 10% of the scaling, corresponding to 2% of Un, may normally be obtained. If a higher accuracy is required, the unit (the generator) connected to the relay must be regulated until the required set point value is reached. When the input voltage drops below/exceeds the set point, the relevant yellow LED of the RMV-112D is lit. 4189340236C (UK)

2.6 Technical specifications Frequency range: 40 45 65 70Hz Max. input voltage: 1.2 x U n, continuously, 2 x U n for 10 s Load: Relay contacts: Contact ratings: Contact voltage: Response time: Galv. separation: Consumption: 2k /V 1 changeover switch per relay 250V-8A-2000A (AC), 24V-8A-200W (DC) Max. 250V (AC). Max. 150V (DC). <100 ms Between inputs and outputs: 3250V-50Hz-1 min. (Aux. supply) 3.5VA/2W Page 8 of 8 Tel. (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com