Lightplane 3.5 Recessed

Similar documents
5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

General Installation Instructions

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

EOS LED Surface Mounted Luminaire

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

EOS Linear LED Recessed Luminaires

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

SAVE THESE INSTALLATION INSTRUCTIONS

Installation Instructions For TruLine 1.6A 24VDC

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

INDIVIDUAL MOUNTING: T-Bar

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

General Installation Instructions LED

Linear LED Recessed Luminaires

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

GLASS GLOBE MOBILE LINEAR CHANDELIER

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

A524 ASSEMBLY & INSTALLATION INSTRUCTIONS BELLADONNA PENDANT CASTLETON, VERMONT USA SYNCHRONICITYLIGHTING.COM Rev A 1 OF 7

EOS Direct/Indirect LED Pendant Luminaire

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

SLOT INSTALLATION GUIDE Indoor IP20

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

ETC Installation Guide

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

a.k.a. casegoods instructions

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

HO4 Surface Mount Installation Instructions Overview

Important Safety Instructions

VERDERA T01-A INSTALLATION INSTRUCTIONS MIRRORED CABINET K-99003T-R/K-99003T-L K-99005T-R/K-99005T-L K-99009T

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

End Plate Alignment Pin 80-PIN Paint Mask 35-EXT Plexineon Mounted in Extrusion. Extrusion 75-EXT

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Cellular SlumberShade

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

NX7 SERIES 5-1/2 HANDRAIL

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Pleated Shades with Corded Top Down / Bottom Up Option

Installation Instructions

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

ADAPT. ABILITY. X 6.50" Example of a continuous row. Shown: hanging the fixture via threaded rods.

Installation Instruction

Assembly Instructions for model: VMPR1

Installation Instructions

MaxLite Linear Strip ECO Series

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

Modular & Hardwired Hub Assembly to "X" and "Y" Posts

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Cellular Shades CORD LOOP Standard Top Down - Bottom Up. Installation & Care Instructions

Pow-R-Feed Systems Service Manual

Height Adjustable Benching End Panel and Utility Pole

INSTALLATION INSTRUCTIONS

SERIES S76PF INSTALLATION INSTRUCTIONS

SLW 6 Channel Letter Brake. User Guide. Operation and Mounting Instructions

TASK: Replace Control Mechanism/Drive End for G71 Supervue/Everglide Vertical headrail

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

MM750 Installation Instructions

Luxe Linen Honeycomb Shades

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Installation Guide. SN-LM42 Brilliance Series Photoluminescent Area of Rescue Signs

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Installation Instructions

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

HONEYCOMB SHADES. Cordless INSIDE MOUNT. A few simple tools are required: STANDARD HARDWARE OPTIONAL HARDWARE

Figure A. Figure B. Figure C. Figure D

MESO X1 TBAR SEMI-RECESSED

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

Cosmopolitan Grand Hardware

ALWAYS TURN FIXTURE OFF/DISCONNECT POWER AND ALLOW TO COOL BEFORE PERFORMING ANY MAINTENANCE, INCLUDING RELAMPING AND CLEANING!

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

Installation Instructions

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

Studio Face Xtreme 6020 Installation Instructions (Nickel , Black )

Assembly Instructions

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.

Senior Swing. Caution

Transcription:

INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions before installing fixture. Always follow applicable building codes when installing any light fixture. Due to product variations and configurations, these instructions serve only as a general guide. Refer to factory provided submittals for details. This fixture is intended for installation in accordance with the National Electric Code and Local and State Codes and must be installed by a licensed electrical contractor. Do not install this fixture in damp locations. Do not install less than four (4) inches from the ceiling (not including ceiling mount). This fixture is for installation in non insulated ceilings only. To prevent electrical shock, turn off electricity at fuse box before installing the fixture.

INSTALLATION A GRID WALLBOARD A1. Turn the power off at the fuse box before installing the fixture. A2. A2. Support the unit to the structure via an all-thread stud, using a coupling nut or blocking (by others). Threaded Stud using Coupling nut A3. If joining multiple fixtures together remove endcaps where fixtures are joined together and loosen set screws on joining bar hardware. Extend joining bars from end of fixture and secure. Connect the wires between the fixtures. Attach the white, black and green wire connectors using the provided connectors. Push the excess wire into the fixture. Do not pinch wires between the parts. Join the segments together and secure the fixtures with the joining bar set screw hardware. A4. While protecting finished parts and supporting the fixture, pull the building wires through the knockout and attach the conduit hardware to the fixture. Secure the fixture to the ceiling with brackets (provided) or by using fasteners to secure the fixture to blocking or the building structure (by others). A5. While supporting the reflector assembly, attach the building wire to fixture using disconnect (provided) or by using a U.L. approved wire connector. Connect the luminary neutral wire (white) to the supply neutral, then connect the luminary line wire (black) to the supply line wire. Fasten ground wire (green) to ground wire. A3. A7. Joining bar A6. Turn on the power. Suction Cup A7. Use Suction cup to remove / install lens during maintenance. Use Suction cup to remove / install lens during maintenance Pg 2 of 5

INSTALLATION B TRIMLESS B1. Turn the power off at the fuse box before installing the fixture. B2. B2. Support the unit to the structure via an all-thread stud, using a coupling nut or blocking (by others). Threaded Stud using Coupling nut B3. If joining multiple fixtures together remove endcaps where fixtures are joined together and loosen set screws on joining bar hardware. Extend joining bars from end of fixture and secure. Connect the wires between the fixtures. Attach the white, black and green wire connectors using the provided connectors. Push the excess wire into the fixture. Do not pinch wires between the parts. Join the segments together and secure the fixtures with the joining bar set screw hardware. B4. Pull the building wires through the knockout and attach conduit hardware to fixture. Secure fixture to ceiling with screws (by others) or using fasteners to secure the fixture to the blocking or the building structure (by others) as needed. B5. Insert the fixture into the opening and align the opening to be flush with the surface. Do not force the fixture into opening or bend the wire-body. Expand the opening in the surface as needed to fit the fixture through. Bending the wire-body will cause the lens to not fit securely and will damage the fixture. Secure the extrusion with screws by attaching the fins to the drywall and-or blocking. Putty in the gap between the opening and the wirebody and finish the area until smooth. B6. While supporting the reflector assembly, attach the building wire to fixture using disconnect (provided) or by using a U.L. approved wire connector. Connect the luminary neutral wire (white) to the supply neutral, then connect the luminary line wire (black) to the supply line wire. Fasten ground wire (green) to ground wire. Then push the wires into wire-body, do not pinch the wires between the parts. B7. Turn on the power. B3. B4. 6.375" 4.0" 3.875" B5. Joining bar 3.75" lens 4.0" Rough Opening Feathering compound or tape Pg 3 of 5

INSTALLATION C PERIMETER GYPSUM C1. Install the blocking before installing the fixture according to the dimensions (see C3-5 diagram). C2. Rotate the fixture into the installed blocking, be careful not to damage the fixture. C3. Fastened the fixture to the blocking. C2. Rotate the fixture into the space C4. Attach the electrical to the rear knockouts. Attach the electrical to the rear knockouts. C5. Install the ceiling surfaces last and then patch and paint the ceiling. For Hard ceilings, blocking installed before installing the fixture C3-5. 1/2" electrical fitting to rear hole (by others) 4.625" lens 7.50" Min Block Height Hanger threaded rod by others Housing affixed to blocking 3.063" 4.25" INSTALLATION D PERIMETER GRID D1. Install the blocking before installing the fixture according to the dimensions (see right). D2. Move the fixture into place, be careful not to damage the fixture. D3. Fastened the fixture to the blocking. D4. Attach the electrical to the rear knockouts. Attach the electrical to the rear knockouts. D1-5. Ceiling / Surface installed after fixture 1/2" electrical fitting to rear hole (by others) Hanger wire by others Blocking installed before fixture installation - fixture flange fastened to blocking D5. Install the ceiling tiles last. 4.19" Ceiling tiles installed after fixture Pg 4 of 5

INSTALLATION D LENS SECURITY CLIP D1. Secure the clip to the white reflector with the 2x self drilling / self tapping sheet metal screws (provided). D2. Install the 2x lens security clips 1/3 of the length of the aluminum extrusion. Avoid installing lens clips in the center of the lens. D3. Remove the reflector to attach the lens clip and prevent damages to the electrical components. The reflector must fully be seated in the fixture and align to the second slot. D4. The lens security clip should apply pressure to the lens at this location. The clip can be adjusted to support the lens as needed. D1-4. Lens Lamps Screws Clips Reflector SAFETY WARNING! Turn OFF all power at the circuit breaker before lens security clip installation. Do NOT install clips on an energized fixture. Pg 5 of 5