Non-contact Forehead IR Thermometer

Similar documents
High Temperature InfraRed Thermometer with Laser Pointer

Non-contact Forehead IR Thermometer

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

User s Guide. Combination Photo-Tachometer Stroboscope Model

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

TERMOMETRO A DISTANZA A INFRAROSSI INFRARED NON-CONTACT THERMOMETER THERMOMÈTRE À INFRAROUGES SANS CONTACT TERMÓMETRO INFRARROJO SIN CONTACTO

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

User s Guide. Digital AC/DC Clamp Meter Model 38394

True RMS AC / DC Power Clamp Meter Model

USER GUIDE. IR Thermal Scanner. Model IRT500

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Manual. Ground Resistance Clamp On Tester MODEL

200Amp AC Clamp Meter + NCV Model MA250

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Heavy Duty Meter Model

Model Digital Light Meter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Passive Component LCR Meter

User's Manual. Model f/1f Power Clamp-on Meter

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

Passive Component LCR Meter

Pen Multimeter. Model

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Pen Multimeter. Model

INSTRUCTION MANUAL INF Fax: (503)

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

User's Manual. Clamp-on Power Datalogger. Model

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Autoranging Multimeter Extech EX503

16mm. inch. Sensor Beam

RF EMF Strength Meter

IR-829 Infrared Thermometer User Manual

OPERATION MANUAL INFRARED THERMOMETER FIRT 500

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

Wireless AC Circuit Identifier

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Non-Contact Infrared Thermometers. 8818H/8819H/8828H series. Operation Manual

Micro-Ohmmeter Model UM200

Non-Contact Infrared Thermometers Operating Manual

PIN/PINLESS DEEP SENSING MOISTURE METER WITH SPHERICAL SENSOR AND REMOTE PROBE

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

Handheld Infrared Thermometers

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

Dawson DSM150. Digital Light Meter User s Manual

Visit us at

SAFE USE &OPERATIONS MANUAL

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

MICROSCANNER TM D-Series

GSIR 6816 Series Infrared Thermometer

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

User Manual ARC Devices Ltd.

4-in-1 Humidity, Temperature Airflow and Light Meter

User Guide. EasyView Digital Light Meter. Model EA31

INSTRUCTION MANUAL UTL260

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

INDEX OPERATING PRINCIPLE... 3 Power Supply... 4 Replacing the Batteries... 4 GENERAL PHOTOMETER OPERATION... 4 Operating Modes... 4 SYSTEM MODE...

Revision 1.8 II WARANTY

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

WSA 8 BOX RELE Installation Manual

2 IN 1 DIGITAL COATING THICKNESS GAUGE MODEL - KM 118A OPERATION MANUAL LIST OF PRODUCTS

User's Guide. Heavy Duty CFM Thermo-Anemometer. Model Washington Street Melrose, MA Phone Toll Free

Combination Photo-Tachometer Stroboscope Model

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Pocket Weatheradio with Tone and Vibrating Alert

Temp / RH / CO 2 Hand-Held Meter

User Manual 4 wire Earth Resistance Tester Model GRT300

Revision 1.4 II. Warranty

User Guide. AC/DC Mini Clamp Meter. Model

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

Dawson DDM190. Digital Multimeter User s Manual

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Geotagger N3. User Manual (V1.0) Revised by Geosolve.be (Pol F. Gillard) with personal updates and help. Solmeta Technology Co.

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Frequency Calibrator with Totalizer

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

DM-46 Instruction Manual

User Manual Digital Wireless Rain Gauge

Thermometer model 02059

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

Using the USB Output Port to Charge a Device

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

05MM-RE03. Remote Control Extender User s Manual

05MM-RE03. Remote Control Extender User s Manual

Transcription:

User s Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Non-contact Forehead IR Thermometer Model IR200

Introduction Congratulations on your purchase of the Model IR200 IR Thermometer. This thermometer is intended for scanning groups of individuals or monitoring an individual for elevated temperatures. It is not a substitute for a clinical thermometer. Always use a clinical thermometer when high accuracy body temperature measurements are required. Considerations and Warnings Read all instructions before using this product. For the most accurate results, make reading with an ambient (room) temperature of 73 to 82 F (23 to 27 C) Make sure the skin is dry and that no hair interferes with the measurement. Do not immerse the meter in water. Avoid touching and/or scratching the infrared sensor lens. Always use a clinical thermometer to verify any abnormal temperature measurements. Clean the lens area by gently blowing with compressed air and use a damp swab to wipe the lens. Do not use any solvents to clean the lens. Measurement Notes 1. If the meter has been stored in a cold or hot environment, allow it at least 20 minutes to acclimate to room temperature before making measurements. 2. To prevent transmission of disease, avoid direct contact with the skin. 3. After heavy exercise always wait at least 10 minutes before taking forehead temperature readings. Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. 2

Meter Description 1. IR sensor 2. Body Surface switch 3. button 4. button 5. MODE button 6. Measurement trigger 7. LCD display 8. Battery compartment 1 2 3 4 5 6 7 8 DISPLAY 1. Surface mode 2. Body mode 3. Temperature display 4. Memory location 5. Alarm active 6. Temperature units 7. Low battery icon 8. Memory temperature display 1 2 3 4 5 6 7 8 3

Operating Instructions Body Temperature Measurements 1. Set the Body-Surface- switch for Body for accurate measurements in the range of.86.0 to 109 F (30 to 43 C). 2. Hold the meter by its handle and point it toward the surface to be measured. Measurement distance should be 2 to 6 (5 to 15cm). 3. Press the trigger to turn the meter on and take a temperature reading. The temperature reading appears in the large display and the logged data number and value appear in the smaller display. 4. Release the Trigger and the reading will hold for approximately 7 seconds after which the meter will automatically shut off. Trigger presses can occur up to a rate of one a second to quickly log samples. 5. If the temperature goes above 109 F or 43 C, Hi will appear in the display. If the temperature goes below 86 F or 30 C, Lo will appear in the display. Body Temperature Mode settings 1. With the meter OFF, press the MODE button once to set the C/F temperature units. The temperature units will flash. Press the or buttons to change the units. 2. Press the MODE button a second time to set the alarm temperature limit. Press the or buttons to change the value. 3. Press the MODE button a third time to enter the long term calibration drift correction mode. On entering the mode, the previous temperature correction factor will appear on the display. To make a correction, measure a known, fixed temperature source. Enter the correction mode and press the or buttons to change the correction value and minimize the difference in readings. Repeat and adjust the correction value as needed until the measurement on the IR200 matches the known temperature. 4. Press the MODE button a fourth time to set the alarm buzzer status. Press the or buttons to switch from ON to OFF. Surface Temperature Measurements 1. Set the Body-Surface- switch for Surface for wide range surface measurements of most materials. 2. Hold the meter by its handle and point it toward the surface to be measured. 3. Press the trigger to turn the meter on and take a temperature reading. The temperature reading appears in the large display and the logged data number and value appear in the smaller display. 4. Release the Trigger and the reading will hold for approximately 7 seconds after which the meter will automatically shut off. Trigger presses can occur up to a rate of one a second to quickly log samples. 5. If the temperature goes above 140 F or 60 C, Hi will appear in the display. If the temperature goes below 32 F or 0 C, Lo will appear in the display. 4

SurfaceTemperature Mode settings 1. With the meter OFF, press the MODE button once to set the C/F temperature units. The temperature units will flash. Press the or buttons to change the units. 2. Press the MODE button a second time to set the alarm temperature limit. Press the or buttons to change the value. 3. Press the MODE button a third time to set the alarm buzzer status. Press the or buttons to switch from ON to OFF. Data memory To review the logged data points, press both the and buttons while the unit is OFF. Use the or buttons to scroll through the memory locations. To clear logged data, select the 0 memory location and press the MODE button. The unit will beep twice to indicate memory has been cleared. Field of View The meter s field of view is 8:1. For example, if the meter is 8 (20cm) from the target (spot), the diameter of the target must greater than 1 (2.5cm). Other distances are shown in the field of view diagram. Measurements should normally be made as close as possible to the device under test. The meter can measure from greater distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 6 Battery Replacement When the low battery symbol appears on the display, replace the meter s battery. The battery compartment is located on the bottom of the handle. Open the compartment by removing one screw and sliding the cover off. Replace the (2) AA batteries and close the battery compartment cover. 5

IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements through transparent surfaces such as glass may not be accurate. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. Specifications Range Accuracy Body Temp 86.0 to 109 F (30 to 43 C) ±0.5 F/0.3 C Surface Temp 32.0 to 140 F (0 to 60 C) ±1.5 F/0.8 C Emissivity 0.95 fixed Field of View D/S = Approx. 8:1 ratio (D = distance; S = spot or target) IR Spectral response 6 to 14 μm (wavelength) Display Backlit LCD display with function indicators Response time 500ms Over range indication Hi or Lo Operating Temperature 32 o F to 122 o F (0 o C to 50 o C) Operating Humidity 10% to 90%RH operating, <80%RH storage. Storage Temperature -4 to 140 o F (-20 to 60 o C) Power Supply (2) AA Batteries Automatic Power Off 7 seconds (approx.), Weight 6.24oz. (177g) Dimensions 6.3 x 3.2 x 1.7 (160 x 82 x 42mm) Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. 6

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Copyright 2009 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 7

8