Multipoint Temperature Controller

Similar documents
Multi-point Temperature Controller

Model Number Structure

CompoBus/D-type Digital Controller

Model Number Structure

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC


Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Fluoro plastic housing for highest chemical and detergent resistance

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Model Number Structure

Phase-sequence Phase-loss Relay

E8EB-N0C2B E8EB-N0B2B

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Model Number Structure

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Switch Mode Power Supply

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Single-phase Voltage Relay

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

LED Displacement Sensor

CSM_G7S-_-E_DS_E_7_1

E3X-DRT21/SRT21/CIF11

Model Number Structure

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Temperature Controllers E5 J

Single-phase Current Relay

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Sensing method Sensing distance Model

MY-GS CSM_MY-GS_DS_E_2_1

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

New Product News. Programmable Digital Controller E5AR-T/E5ER-T. One Digital Controller with Up To 32 Programs

Switch Mode Power Supply

Safety Relay Unit. OFF-delay time

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

E6F-CWZ5C (1000P/R) 2M

Fuzzy Temperature Controllers E5AF

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Description Model Specification Base Unit E5CK-AA1 AC Base Unit. Description Model Specification Output Unit E53-R4R4 Relay/Relay

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

Model Number Structure

NEW. Better Productivity by Standstill and Low-speed Monitoring

Inductive Proximity Sensor

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

NPN PNP NPN PNP NPN PNP

APPENDIX APPENDIX A 1

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Page H x 96 W x 69.5 D mm (1.89 x 3.78 x 2.74 in)

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

FA Wireless SS Terminals

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

SPST-NO SPDT DPST-NO DPDT

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Features. 2-Dimensional Code Reader (Fixed Type) V530-R150E-3, EP-3

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Alternate Operation Relay 61F-AN/-APN2

3. Contact Form A: SPST-NO

Instruction Manual Inductive Gauging Sensor

Distance-setting Photoelectric Sensor

E6F-CWZ5C (1000P/R) 2M

Self-powered Counter

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Fuzzy Temperature Controllers E5EF

Digital Controller E5CK

Digital Amplifier Ultrasonic Sensor E4C-UDA Series

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

F210 Vision Sensor Flow Menus and Macro Capability

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Distance-setting Photoelectric Sensor

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

E5CN-H (48 x 48 mm) CSM_E5CN-H_DS_E_4_7

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Correction Reissue. Product Discontinuation Notices

Transcription:

Multipoint Temperature Controller E5ZE-8@D1@B-V2 Multipoint Temperature Controller Connects to the Programmable Controller with Ease Conforms to DeviceNet requirements with remote I/O and FINS message communications, thus connecting to a CompoBus/D Master without programs for remote I/O communications and to OMRON s Programmable Controller with ease for explicit message communications. High-speed input sampling of only 0.2 s at the maximum of eight temperature inputs. Model Number Structure Model Number Legend E5ZE-8@@@D1@B-V2 1 2 3 4 5 6 7 8 1. Number of Control Points 8: 8 channels 2. Control Method A: Standard (heating or cooling) V: Heating and cooling 3. Control Output (Heating Side) Q: Voltage output (for driving SSR) C: Current output 4. Heater Burnout and SSR Failure Detection (See note 1.) H: Available A: Not available 5. Communications Function D1: DeviceNet 6. Input TC: Thermocouple P: Platinum resistance thermometer 7. Case B: Provided (Models with case) 8. Version V2: Supports explicit messages Note: 1. Heater burnout and SSR failure detection are not available when the control output on the heating side is current output. 2. Refer to the List of Models for combinations of functions. Multipoint Temperature Controller E5ZE-8@D1@B-V2 1

Ordering Information List of Models No. of control points Note: 1. Cooling control is possible by making a change in output operation. 2. Models without the heater burnout/ssr failure detection function are also available. 3. Cooling control output is an open collector output (NPN). Accessories (Order Separately) Setting Display Unit Note: Not all the functions of the E5ZE can be set, which should be taken into consideration when designing the system. For details, refer to the E5ZD-SDL Setting Display Unit Datasheet (H061). Current Transformers (CT) Special Cables Control method Control output Heater burnout and SSR failure detection Recommended Power Supplies Input type Thermocouple Platinum resistance thermometer 8 Standard Voltage Available (see note 2) E5ZE-8AQHD1TCB-V2 E5ZE-8AQHD1PB-V2 (see note 1) Current Not available E5ZE-8ACAD1TCB-V2 E5ZE-8ACAD1PB-V2 Heating and cooling Voltage Available (see note 2) E5ZE-8VQHD1TCB-V2 E5ZE-8VQHD1PB-V2 Current (see note 3) Not available E5ZE-8VCAD1TCB-V2 E5ZE-8VCAD1PB-V2 Connecting model Connecting part Power supply Model RS-232C Connector 100 to 240 VAC E5ZD-SDL1 24 VDC Hole diameter 5.8 mm 12.0 mm Model E54-CT1 E54-CT3 Model E5ZE-CBL200 ES100-CT021-202 (25-pin) ES100-CT023-202 (9-pin) S82J S82K Series 2 Multipoint Temperature Controller E5ZE-8@D1@B-V2

Specifications Ratings Supply voltage 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 15 W + 20% max. at rated supply voltage Input Input type Thermocouple: K, J, R, S, T, E, B, N, L, U, W, PL-II Platinum resistance thermometer: Pt100, JPt100 Input impedance Thermocouple: 1 MΩ min. Rated platinum resistance 1 ma thermometer current Control Standard (Heating side) Voltage output (with short-circuit protecting function) outputs ON: 12 ± 1.2 VDC OFF: 0.5 VDC max. Max. load current: 30 ma DC per point Current output Rated output range: 4 to 20 ma DC Current output range: 0 to 22 ma DC With an output value of 0%: 4 +0 / 0.6 ma DC With an output value of 100%: 20 +2 / 0 ma DC Max. load resistance: 600 Ω per point Cooling side Open collector output (NPN) Max. applied voltage: 30 VDC Max. load current: 50 ma DC per point ON residual voltage: 2 VDC max. OFF leakage current: 1 ma DC max. Alarm outputs Temperature alarm: The total output of all control points (alarm 1 NPN open collector output and alarm 2 NPN open collector output) HB alarm (heater burnout detection): Total output of all control points (1-point NPN open collector output) HS alarm (SSR failure detection): Total output of all control points (1-point NPN open collector output) Temperature controller error output (memory, set value, or hardware error): 1-point NPN open collector output Max. applied voltage: 30 VDC Max. load current: 50 ma DC per point No. of input control points 8 input and 8 control points Setting method Via communication Control modes ON/OFF control Hybrid of advanced PID control and fuzzy control Manual operation Memory bank input No. of points: 8 for each control point Designation method: Through communication or memory bank designation input Memory bank designation inputs With contact signal input ON short-circuit resistance: 1 kω max. OFF open resistance: 100 kω min. With no-contact signal input ON residual voltage: 2 VDC max. OFF leakage current: 1 ma DC max. Multipoint Temperature Controller E5ZE-8@D1@B-V2 3

Input Ranges Thermocouple Input (switch selectable) K (CA) Chromel vs. alumel (see note 1) Range C 200 to 1,300 F 300 to 2,300 J (IC) Iron vs. constantan 100 to 850 100 to 1500 R Platinum vs. Platinum rhodium 13% S Platinum vs. Platinum rhodium 10% T (CC)/U Copper vs. constantan 0 to 1,700 0 to 1,700 200 to 400 0 to 3,000 0 to 3,000 300 to 700 E (CRC) Chromel vs. constantan B Platinum rhodium 30% vs. platinum rhodium 6% 0 to 600 100 to 1,800 0 to 1100 300 to 3,000 N Nichrosil vs. nisil L Iron vs. constantan 0 to 1,300 100 to 850 0 to 2,300 100 to 1,500 U Copper vs. constantan 200 to 400 300 to 700 W (see note 2) PL-II (Platinum) 0 to 2,300 0 to 1,300 32 to 4,100 0 to 2,300 Setting no. 0 1 2 3 4 5 6 7 8 9 A B Min. setting 1 C or 0.1 C unit Platinum Resistance Thermometer Input (switch selectable) Pt 100 (see note 1) JPt 100 Range C 100.0 to 500.0 100.0 to 500.0 F 100.0 to 900.0 100.0 to 900.0 Setting no. 0 1 Min. setting unit 1 C or 0.1 C Note: 1. A temperature range is factory-set to a range of 200 to 1,300 C (for K(CA)) or 100.0 to 500.0 C (for Pt 100). 2. Thermocouple W is W/Re5-26 (tungsten rhenium 5, tungsten rhenium 26). Characteristics Measurement accuracy (see note) Thermocouple: (±0.3% of the process value or ±2 C, whichever greater) ±1 digit max. (±0.3% of the process value or ±3.6 F, whichever greater) ±1 digit max. Platinum resistance thermometer: (±0.3% of the process value or ±0.8 C, whichever greater) ±1 digit max. (±0.3% of the process value or ±1.5 F, whichever greater) ±1 digit max. Hysteresis 0.0 to 99.9 C/ F for ON/OFF control only (in units of 0.1 C/ F) Cooling coefficient 0.0 to 10.0 (in units of 0.1) Proportional band 0.0 to 999.9 C/ F (in units of 0.1 C/ F) Cooling side: Cooling coefficient Proportional band Integral (reset) time 0 to 3,999 s (in units of 1 s) (for both heating and cooling) Derivative (rate) time 0 to 3,999 s (in units of 1 s) (for both heating and cooling) Control period Heating side: 1 to 99 s (in units of 1 s) Cooling side: 1 to 99 s (in units of 1 s) Sampling period 200 ms for 8 control points Dead band/overlap band 999 to 999 C/ F (in units of 1 C/ F) Alarm output setting range 999 to 9999 C/ F, 0 to 9999 C/ F (upper- and lower-limit alarm) (in units of 1 C/ F) 999.9 to 9999.9 C/ F, 0.0 to 9999.9 C/ F (upper- and lower-limit alarm) (in units of 0.1 C/ F) (see note 3) Fuzzy strength 0% to 99% (in units of 1%) Fuzzy scale 1 0.2 to 999.9 C/ F (in units of 0.1 C/ F) Fuzzy scale 2 0.02 to 99.99 C/s or F/s (in units of 0.01 C/s or F/s) Set value backup Lithium battery Set value backup period 10 years min. provided that the ambient temperature is within the room temperature Insulation resistance 20 MΩ min. between the FG terminal and all analog input terminals (at 500 VDC) Dielectric strength A leakage current of 1 ma AC max. with 500 VAC for 1 minutes between the FG terminal and all analog input terminals Vibration resistance Malfunction: 10 to 55 Hz, 15 m/s 2 for 8 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 20 m/s 2 for 8 min each in X, Y, and Z directions Shock resistance Malfunction: 150 m/s 2, 3 times each in 6 directions Destruction: 200 m/s 2, 3 times each in 6 directions Ambient temperature Operating: 0 to 55 C (with no icing or condensation) Storage: 25 to 65 C (with no icing or condensation) Ambient humidity Operating: 35% to 85% Storage: 35% to 95% 4 Multipoint Temperature Controller E5ZE-8@D1@B-V2

Dimensions Enclosure rating Weight With casing: 173.5 x 253 x 65 mm max. IP00 With casing:1,700 g max. Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400 C or 750 F max. is not guaranteed. The following measurement accuracy values are applied to the E5ZE. K and T at 100 C max. and U: ±3 C ±1 digit max. K and T at 100 F max. and U: ±5.4 F ±1 digit max. R, S, and W at 200 C max., and B at 1,000 C max.: ±4 C ±1 digit max. R, S, and W at 400 F max., and B at 1,800 F max.: ±7.2 F ±1 digit max. 2. The measurement accuracy of the E5ZE used with any thermocouple is 1 C/ F. The thermocouple can be used under the following temperature ranges to increase the measurement accuracy to as high as 0.1 C/ F. K thermocouple: 0.0 C to 1,300.0 C, 0.0 F to 2,300.0 F T or U thermocouple: 0.0 C to 400.0 C, 0.0 F to 700.0 F N thermocouple: 400.0 C to 1,300.0 C, 700.0 F to 2,300.0 F J, E, L, or PLII thermocouple: Any temperature 3. Upper limit is 3000.0 C/ F when set from CompoBus/D. Communications Specifications Conforming to DeviceNet Communications Protocol For details, refer to the CompoBus/D (DeviceNet) Operation Manual (W267) and the E5ZE-8 Communication Manual (H114). Connection method Multi-drop or T-branching (see note 1) Baud rate 500/250/125 kbps Communications media Dedicated 5-wire cable (with 2 communications wires, 2 power wires, and 1 shield wire) Communications distance Baud rate Maximum network length (see note 2) Branch line length Total branch line length 500 kbps 100 m max. (see note 3) 6 m max. 39 m max. 250 kbps 250 m max. (see note 3) 6 m max. 78 m max. 125 kbps 500 m max. (see note 3) 6 m max. 156 m max. Remote I/O points IN: 14 / OUT: 9 Error control CRC error and node address duplication check Note: 1. An external terminator must be attached. 2. Indicates the distance between nodes farthest from each other. 3. The maximum network length is 100 m if a thin dedicated cable is applied to the trunk line.!notice This product has been tested by ODVA s authorized Independent Test Lab and found to comply with ODVA Conformance Test Software Version A-13. For the specifications of objects in details, refer to the E5ZE-8 Communication Manual (H114). DeviceNet Communications Items Remote I/O communications IN: PV (process value) (8 points), Alarms 1 and 2 status, AT status, HB alarm status, HS alarm status, and error status OUT: RUN/STOP and SP (set point) (8 points) Explicit message communications All read and write parameters (See note.) Note: Items for the OUT side of remote I/O are not included. Multipoint Temperature Controller E5ZE-8@D1@B-V2 5

System Configuration E5ZE-8@D1@B-V2 ES100-CT021-202 or ES100-CT023-202 E5ZD-SDL1 Setting Display Unit Note: Do not use the RS-232C auxiliary jack for permanent connection when the E5ZE is mounted to equipment. Power supply input Regulated DC power supply Host Unit Compatible with Explicit Message Communications OMRON's C200HW-DRM21-EV1, CVM1-DRM21-EV1 and CS1W-DRM21 Temperature sensor input Thermocouple E5ZE-CBL200 E5ZE-CBL200 XW2D-20G6 Connector Terminal Conversion Unit Note: When replacing with an E5ZE- 8@D1@B, part of the ladder program must be changed. Platinum resistance thermometer E5ZE-CBL200 XW2D-20G6 Connector Terminal Conversion Unit G7TC-OC08/G7TC-OC16 I/O Block G70D-V@O@16 Relay terminal!caution Be sure to use the above Units, which save wiring effort, and connection cables for the prevention of malfunctions or accidents that may be caused by mistakes in wiring. Dimensions Note: All units are in millimeters unless otherwise indicated. E5ZE-8@D1-@B-V2 Mounting bracket Mounting Holes Four, M4 Mounting bracket 6 Multipoint Temperature Controller E5ZE-8@D1@B-V2

Precautions Mounting the Controllers Side-by-side, Close Mounting Saves space and improves wiring efficiency. Control panel Up General Mounting Precautions The side of the E5ZE with the terminal block and connectors must not face up, otherwise operating errors may result. Prepare four M4 screws to mount the E5ZE to control panels. Use flat washers and spring washers with screws to mount the E5ZE to control panels so that the screws will not loosen. The mounting brackets must be attached to the E5ZE with the four M3 6 screws provided with the E5ZE and each of the screws should be tightened to a torque of 0.43 to 0.58 N m, or 4.4 to 5.9 kgf cm. Do not mount as shown in the following diagram. Incorrect Wall Mounting Can be mounted to places with limited depth. Control panel Control panel Up Multipoint Temperature Controller E5ZE-8@D1@B-V2 7

Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products. Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. H103-E1-02 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Industrial Devices and Components Division H.Q. Measuring Components Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7080/Fax: (81)75-344-7189 Printed in Japan 0703-0.3M (1098) (A) 8