WARNING Instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this product must be instaed in accordance to Nationa Eectric Code in the US or Canadian Eectrica Code (CSA22.1) in Canada. Channe Letter modues are ony to be used with the 12VDC power suppies isted in this guide. INSTALLATION INSTRUCTIONS 1. Lay out the modues ike neon, ony without doube-backs, approximatey 2-4 per foot, depending on the modue type (see Figure 1 for spacing modues center-center). Be sure to test your first etter to make sure you are satisfied before proceeding. Figure : Modue spacing Approximate Modue Series Center - Center Right Light - 2 Up Right Light - Up Tadpoe Tadpoe 4 4 - - 2 Modue Series Point Saver Quasar Approximate Center - Center 2. For power suppy oading, see Page or foow this ink: www.used.com/channe_etter_oading.htm.. Insta ength of product in etters by fastening mounting cips with VHB tape (suppied) or mechanicay through hoes in the cip, or both. Add siicone for additiona security if desired (see Figure 2). Figure 2: Exampe ayout 4. Connect separate runs of product within a etter using Quick Connect jumper wires with pre-crimped connectors. These wires come in pairs of Bue (negative) and Red (positive). Simpy connect one negative tab at the end of any modue on one run to a negative tab at the end of any modue on the second run. Then repeat process connecting a positive tab on one run to a positive tab on the other (Figures and 4). See Wiring Diagram on Page for further detais. Figure : Exampe power jump Figure 4: Connecting modues with Quck Connect Jumper Wires Page 2 Updated 0.1.11 07 PORTWEST DR HOUSTON, TX 77024 T 72 11 F 71 72 info@used.com www.used.com
INSTALLATION INSTRUCTIONS (cont). The Quick Connect jumper wires with cass 2 wire shoud be used to connect modues from etter to etter, whie the -Foot Whip is to be used to connect a run of modues to a power suppy (See Wiring Diagram on Page ). Athough jumps can be made from etter to etter and then from the fina etter to the power suppy, the preferred method is to run each etter to the power suppy. The secondary wires on the power suppies are coor coordinated to match (Bue for negative and Red for positive or Back for negative and Yeow for positive on oder products). A runs through a wa must either be in a conduit or pass-thru or be made with cass 2 wire. See Figure for an exampe instaation. Figure : Exampe ayout Limit the tota number of modues per run to 1/ of the tota power suppy oad. This wi increase your oad baance and ight uniformity. For exampe: using the Quasar (QZR--12-W) on a 0W power suppy, you woud imit the tota number of modues on each run to 2 (or 1 feet) and connect at the midpoint.. Repair and sea any unused openings in the rain encosure. Openings greater than 1/2 inch diameter require a meta patch secured by screws or rivets and cauked with non-hardening cauk. Smaer openings may be seaed with non-hardening cauk. 7. Attach channe etter face(s).. Energize sign. Page Updated 0.1.11 07 PORTWEST DR HOUSTON, TX 77024 T 72 11 F 71 72 info@used.com www.used.com
POWER SUPPLY LOADS Right Light Series PS-2-12-RX PS--12-RX RL-2-12-RX RL--12-RX RL-2-12-B RL-2-12-G RLS-2-12-O RLS--12-O RLS-2-12-Y SV--12-W SV--12-W0 PT--12-W PT--12-W0 PT--12-W40. 4..2 4. 4. 12 17. Feet / 0W 14. 0 0 4 0 0 0 0 4 4 0 0 0 Tadpoe Series TP-2-12-R TP-2-12-G TP-2-12-B TP-2-12-W TP-2-12-W TP-2-12-W40 TP-2-12-W40 2. 2 2 4 Feet / 0W 4. 27 0 0 0 20 0 20 MegaWhite Series QZR--12-W 2 Feet / 0W 7 41 WIRING DIAGRAM Page 4 Updated 0.1.11 07 PORTWEST DR HOUSTON, TX 77024 T 72 11 F 71 72 info@used.com www.used.com
TROUBLESHOOTING Symptom Possibe Cause Soution A singe modue not ighting Mafunction on modue Leave mafunctioning modue in pace. Mount repacement modue aongside and using jumper wires, connect the positive tab to the positive tab of any modue on the run. Do ikewise with the negative tab. LEDs ficker Entire product run is not ighting A. Underoaded or overoaded B. Mafunctioning power source A. Bad wire connections B. If ony one run of product on power source, mafunctioning power source C. Short D. Overoad A. Adjust oads on power sources to be within recommended imits. B. Repace power source. A. Restore connection. B. Check power source and repace if appropriate. C. Search wiring for a short circuit between the red and bue wires. Repace bad wiring or use eectrica tape to insuate the bad wire(s). D. Adjust oads on power sources to be within recommended imits. Page Updated 0.1.11 07 PORTWEST DR HOUSTON, TX 77024 T 72 11 F 71 72 info@used.com www.used.com