Lawrence A. Soltis, M. and Robert J. Ross, M. 1

Similar documents
DESIGN EQUATION FOR MULTIPLE- FASTENER WOOD CONNECTIONS

Anti-check bolts as means of repair for damaged split ring connections

Lawrence A. Soltis. James K. Little

Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory

EXAMPLE 1-4 EXAMPLE 1-5

Dowel connections in laminated strand lumber

Simplified analysis of timber rivet connections

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Space-frame connection for small-diameter round timber

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Improved Arcan Shear Test For Wood

Glued laminated timber beams repair.

ABSTRACT INTRODUCTION

Changes in the 2001 NDS for Wood Construction

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

Glulam Connection Details

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II)

B.L. Wills D.A. Bender S.G. Winistorfer 1

Connection and performance of two-way CLT plates

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

LRFD FOR ENGINEERED WOOD STRUCTURES- CONNECTION BEHAVIORAL EQUATIONS

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be

4-Bolt Wood-to-Steel Connections

Mechanical behavior of fiberglass reinforced timber joints

LRFD for Engineered Wood Structures - Connection Behavioral Equations

PERFORMANCE OF FASTENERS IN WOOD

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

AN IMPROVED SHEAR TEST FIXTURE USING THE IOSIPESCU SPECIMEN

Fasteners as Damage Indicators in Timber Structures

Timber Bridge Hardwood Glulam Deck Connector Evaluations under Static and Repetitive Loads

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

SCREW WITHDRAWAL RESISTANCE SHEET METAL SCREWS IN PARTICLEBOARD AND MEDIUM-DENSITY HARDBOARD

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

Connection Design Examples

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Double Shear Testing of Bolts

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

For information on publications, telephone direct: +44 (0) or

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding

LOAD DURATION AND SEASONING EFFECTS ON MORTISE AND TENON JOINTS

What happens to bolt tension in large joints?, Fasteners, Vol. 20, No. 3, 1965, Publication No. 286

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Connection and Tension Member Design

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng.

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

STRUCTURAL TIMBER DESIGN

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

Copyright. Michael Joseph Gilroy. May 1997

Aspen Art Museum Creating Innovative Wood Structure

EVALUATION OF METHODS OF ASSEMBLING PALLETS RESEARCH PAPER FPL U. S. DEPARTMENT OF AGRICULTURE FOREST SERVICE FOREST PRODUCTS LABORATORY

ICC-ES Evaluation Report

Development of Limit States Design Method for Joints with Dowel Type Fasteners Part 2: Comparison of Experimental Results with European Yield Model

Bolts and Set Screws Are they interchangeable?

Two basic types of single

ICC-ES Evaluation Report

Instruction Manual for installing

DESIGN CONSIDERATIONS FOR MORTISE AND TENON CONNECTIONS

TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES

Threaded Fasteners 2. Shigley s Mechanical Engineering Design

COOLING TECHNOLOGY INSTITUTE AN INVESTIGATION OF PIN BEARING

INTERNATIONAL COUNCIL FOR BUILDING RESEARCH STUDIES AND DOCUMENTATION WORKING COMMISSION W18- TIMBER STRUCTURES

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory Theoretical Development

Module 10 : Improvement of rock mass responses. Content

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

FAURICATION OF SMALL MAR. SPECIMENS Of -MEER MR STRENGTH TESTS. -Y1) No February In Cooperation with the University of Wisconsin

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Classic Connection Conundrums

Comparison of behaviour of laterally loaded round and squared timber bolted joints

WITHDRAWAL AND LATERAL STRENGTH OF THREADED NAILS

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS

THE EFFECT OF END DISTANCE AND NUMBER OF READY-TO- ASSEMBLE FURNITURE FASTENERS ON BENDING MOMENT RESISTANCE OF CORNER JOINTS.

Timber Rivet Connections Design Process for a Hanger Connection

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

Bending Properties of Reinforced and Unreinforced Spliced Nail-Laminated Posts David R. Bohnhoff Russell C. Moody Steve P. Verrill Leo F.

Listing Report: AB Reissue Date: 01/21/16 This report is subject to annual review

STABILITY. SECURITY. INTEGRITY.

Design of Bolted Connections per the 2015 NDS

Subject Index. Bearing damage, in bolted, composite-metal

Transcription:

REPAIR OF WHITE OAK GLUED-LAMINATED BEAMS Lawrence A. Soltis, M. and Robert J. Ross, M. 1 Abstract Connections between steel side plates and white oak glued-laminated beams subjected to tension perpendicular-to-grain stresses were tested to failure. The beams were then repaired with five different configurations using two sizes of lag screws, with and without steel reinforcing plates. The repaired beams were re-tested to failure. Results indicate that in all cases the repaired beams had greater ultimate loads than did the original beams. Results also indicate that lag screws without the reinforcing plate are sufficient for repair. Introduction This paper is a report on tests conducted on bolted joints that connected steel side plates to white oak glued-laminated beams and were subjected to tension perpendicular-to-grain forces. The joints are representative of a proprietary connection that had experienced service failure. Objectives were to first determine the failure modes and maximum loads and secondly to determine a repair procedure. Five repair configurations were tested because little information exists on repairing glued-laminated members with tension perpendicular-to-grain failures. Experimental Procedure Eight 254- by 406-mm (10- by 16-in.) glued-laminated (22 laminations) white oak beams, 1.98 m (6.5 ft) long, were tested in bending with a center-point load on a 1.67-m (5.5-ft) span. This is a modification of the standard test procedure described in ASTM D-1761 (ASTM 1988) to determine the strength of a connection loaded perpendicular-to-grain. ASTM D-1761 is essentially a midpoint loaded short deep beam with the load applied through a single bolt. We modified this standard procedure to have the load applied through steel side plates with five 25-mm- (1-in.-) diameter bolts. ASTM D-1761 defines the beam span to be a minimum of three 1 USDA Forest Service, Forest Products Laboratory, One Gifford Pinchot Drive, Madison, WI 53705 116

MATERIALS AND CONSTRUCTION 117 times the beam depth. We modified the span dimension such that we would have three times the beam depth dimension outside of the five-bolt connection area. The tests were conducted in a non-controlled temperature and humidity environment. The moisture content of the beams prior to testing was 7% to 9%, found by a moisture probe meter. Load was applied at a rate of 2.3 mm (0.09 in.) per minute, resulting in failure being achieved in about 5 minutes. The test setup is shown in Figure 1. Relative deformation between the steel side plates and the glued-laminated beam was measured at the bottom row of bolts. Two plots of load versus deflection were recorded for each test. One plot corresponded to relative deformation at the threaded end of the bolt; the other corresponded to the shank end. This was done because there was 13 mm (1/2 in.) of thread bearing on the wood beam. All tests were continued until failure, which is defined as the maximum load the beam could resist. Figure 1. Test setup.

118 MATERIALS AND CONSTRUCTION The eight beams were then repaired and re-tested using the same procedure as for the original tests. Figures 2-6 show schematically the five repair methods. The repair configurations are based on equating the strength of the lag screw (assumed yield stress of 248,200 kpa (36,000 lb/in 2 )) to the wood strength of ultimate tension perpendicular-to-grain stress (5,500 kpa, 800 lb/in 2 ) times a contributary area of a 254-mm (10-in.) beam width by the lag screw spacing. This results in two 25-mm- (1 -in.-) diameter lag screws at about 102-mm (4-in.) spacing. The extent of spacing the lag screws is an unknown, dependent on the length of the tension perpendicularto-grain fracture propagation, so a trial and error approach was used. Repair method 1 consisted of sixteen 25-mm- (1-in.-) diameter by 305-mm- (12-in.-) long lag screws, with two steel reinforcing plates 241 by 6 by 406 mm (9-1/2 by 1/4 by 4 in.). Lead holes were 19 mm (3/4 in.) for the threaded portion and 25 mm (1 in.) for the shank portion of the lag screw. Each plate supported eight lag screws. Repair method 2 used the same lag screws and lead holes as did method 1. However, the steel reinforcing consisted of eight plates 241 by 6 by 102 mm (9-1/2 by 1/4 by 4 in.). Each plate supported two lag screws. This configuration was chosen to enable a repair in a confined space using a number of smaller plates rather than one larger plate. Repair method 3 used 13-mm- (1/2-in.-) diameter lag screws but otherwise had the same configuration as did method 1. Even though recommended-sized lead holes were used during fabrication, 3 of the 16 lag screws in one specimen sheared off. This configuration was chosen to find what beam capacity could be achieved with smaller lag screws. Repair method 4 consisted of eight 25-mm- (1-in.-) diameter by 305-mm- (12- in.-) long lag screws with two steel reinforcing plates 241 by 6 by 203 mm (9-1/2 by 1/4 by 8 in.). This configuration was part of the trial and error process related to the extent of the fracture. It consisted of half the number of lag screws compared with method 1. Repair method 5 had the same lag screw configuration as did method 1 but eliminated the steel reinforcing plate. This configuration was chosen to see if there would be any bearing failures under the head of the lag screw. Results and Discussion For the original and repaired beams, the ultimate center-point loads are given in Table 1. The failures for the original beams were tension perpendicular-to-grain

MATERIALS AND CONSTRUCTION 119 fractures, which initiated at a line of bolts and propagated laterally. The crack propagation stopped prior to reaching the ends of the beams. The crack theoretically should initiate at the line of bolts nearest the loaded edge of the beam. This occurred in some beams while fabrication effects resulted in crack initiation at the other line of bolts in other specimens. We do not believe the initiation location related to the two lines of bolts to be significant. The bolt threads bearing partially on the wood. (considered bad practice) had negligible effect on the strength of the joint. We determined this by comparing deformations on both ends of the bolt. The failure of the original beams was tension perpendicular-to-grain stress. which is found by dividing the ultimate center-point load by some effective area. If the effective area is assumed to be the 254-mm (10-in.) width of the beam times the 279-mm (11-in.) length of the side plates, the resulting tension perpendicular-tograin stress will approximate the published value of 5,500 kpa (800 lb/in 2 ) (Forest Products Laboratory 1987). The failure of the repaired beams was tension yielding of the lag screws used in the repair. The ultimate center-point load for all the repair methods was greater for the repaired beams than for the original joint tests (Table 1). Results indicate no advantage to (1) increasing the number of lag screws from 8 to 16 or (2) using steel reinforcing plates regardless of their size. It appears that increasing the diameter of the lag screw from 13 mm (1/2 in.) to 25 mm (1 in.) is not advantageous. Recall that three of the smaller lag screws sheared off during installation. It was difficult to screw the smaller lags using recommended-sized lead holes into the beams, thus we do not recommend the 13-mm (1/2-in.) diameter. Perhaps a compromise recommendation is to use a 19-mm- (3/4in.-) diameter lag screw, but this is not verified by this study. Table 1. Ultimate center point load for original and repaired beams. Original beam Repaired beam Beam ultimate load Repair ultimate load number (kn) (lb) method (kn) (lb)

120 MATERIALS AND CONSTRUCTION The relative deformation between the steel side plates and the gluedlaminated beams was approximately 3 mm (0.1 in.) for all beams and for both the thread and shank ends. The effect of the 13-mm (1/2-in.) thread length bearing on the wood was negligible. Concluding Remarks This study presents the failure modes and ultimate center-point loads for joints consisting of steel side plates bolted to white oak glued-laminated beams. All failures observed in the original beams were caused by tension perpendicular-tograin stresses. Cracks initiated at one line of bolts and propagated along the grain. Our ultimate loads divided by an assumed effective area compare reasonably well with the published tension perpendicular-to-grain strength for white oak. The original beams were repaired by various combinations of lag screws and reinforcing plates. All repair methods resulted in ultimate center-point loads that exceeded the original beam strength Results indicate that four 25-mm- (1-in.-) diameter lag screws on each side of the joint without a steel reinforcing plate is sufficient for repair. References ASTM. 1988. Test Methods for Mechanical Fasteners in Wood. ASTM D-1761. American Society for Testing and Materials, Philadelphia, PA. Forest Products Laboratory. 1987, Wood Handbook: Wood as an Engineering Material. Ag. Handb. 72. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, rev.

MATERIALS AND CONSTRUCTION 121

122 MATERIALS AND CONSTRUCTION

MATERIALS AND CONSTRUCTION 123

MATERIALS AND CONSTRUCTION Exploring the Connection PROCEEDINGS OF THE FIFTH ASCE MATERIALS ENGINEERING CONGRESS May 10-12, 1999 Cincinnati, Ohio EDITED BY Lawrence C. Bank American Society of Civil Engineers 1801 ALEXANDER BELL DRIVE RESTON, VIRGlNlA 20191 4400