Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Similar documents
INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

BEFORE STARTING INSTALLATION

Installation Instructions

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

INSTALLATION INSTRUCTIONS CRL JACKSON

MORTISE LOCK INSTALLATION INSTRUCTIONS

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

7130(F) Series Mortise Exit Devices Installation Instructions

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

1530(F) Mortise Exit Devices Installation Instructions

Installation Instructions

Entry Mortise Lock Set Lever to Lever

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

WD WD7000 Series

98/ Customer Service # Dogging Key (use to lock down pushbar)

ED5200(A) Series Rim Exit Devices

Installation Instructions for 45H & 47H Mortise Locks

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

Entry Mortise Handleset

Installation Instructions

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

Passage Mortise Lock Set Lever to Lever

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Installation Instructions. Installation Type

Installation Instructions. Installation Type

This is a printable pdf document. For Smartphone-friendly version, tap or click here.

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

* * 9875/ Customer Service #10-24 # Dogging Key (use to lock down pushbar)

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

316R Series Installation Instructions

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

How To Measure Your Finished Opening

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

Installation Instructions For Profile Series v.g1 Exit Device

Installation Instructions FE6800 Series Multi-Point Lock

Exit Device 5820 SERIES GRADE 1 PUSH BAR SPECIFICATIONS HEAD COVER OPTIONS STRIKES APPLICATION.

Installing Your Electronic Deadbolt

3000 Series Exit Devices Premier Product

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

ED5200(A) Series Rim Exit Devices

DC3210. Recommended Closer Size

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

1500(F) Rim Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

Senior Swing. Caution

MORTISE LOCKS LA1Tx7 //DATASHEET

OUTSIDE STRIKE INSIDE. TEMPLATE-S6100 Devices covered by this template: Panic Rim Device and Fire Rim Device. FINISHED FLOOR

Important: Read this first!

Shetland Stalls Installation Instructions

Installation Instructions For The 8850FL Series Mortise eboss

Tools Required. * When installing on a fire door, please see instructions below. *

INSTALLATION INSTRUCTIONS FOR ARCHITECTURAL VALUE SERIES ELECTRIC DOGGING / ELECTRIC LATCH RETRACTION AND "H" MODELS (HURRICANE) Endcap P/N:

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

(Wood Door and Frame)

Installation Instructions II-2/4/5K-0608

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Rim-Lock Door Set Installation Instructions

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

CL4500 Installation Instructions

Assembly Instructions 10 X 10 Aluminum Frame Building

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

3 wide x 3 deep Video Wall Display Installation Guide

ED3000 Series. Exit Device Parts Manual

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

Jenny Legs Assembly Instructions

TABLE OF CONTENTS REQUIRED TOOLS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

F-150 Structural Holding System

Exit Devices 10 SERIES 1200 SERIES 20 SERIES

Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Transcription:

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com These instructions are presented a in step by step sequence. Please read it through before installation. Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters. P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 1

DESIGNATION OF PARTS End Cap Bracket Mortise Strike Face Plate Mortise Lockcase Chassis End Cap A Chassis Cover Dogging Device (Fire Exit Hardware is not equipped with this device) Push Bar Chassis BEFORE INSTALLING THIS EXIT DEVICE : 1. Check device to be sure the type is correct for the application 2. Check device for the correct length, finish and outside trim to be used. NOTE: This model device has 3 different lengths: For use on 3' wide door device = approx. 33" For use on 3-1/2 wide door device = approx. 40" For use on 4' wide door device = approx 44" The lengths of devices are precut for 36", 42" and 48" wide door use, no additional cutting is necessary. If narrow door installation is required, cut device at A portion to door width minus 4" to fit properly. P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 2

1. MARK DOOR FOR DEVICE AND LOCK 1/4 31/32 6-17/32 8-1/32 LC of Mortise Lock LC of Device 40" to Finished Floor LC of Device 4-23/32 Fig 1-1 Fig 1-2 1. If door is already cut out for lock (mortised), check for proper clearance (Fig 1-1). 2. Mark the center line of device by drawing a line across the door 40" above finished floor (Fig 1-2). 3. Tape template to door and frame then mark mounting holes for device chassis and strike. 4. Cut-out and drill holes as marked on door and frame. 2. INSTALL STRIKE TO FRAME OR INACTIVE DOOR 1. Install strike to drilled position on frame or inactive door and secure in place with supplied screws (Fig 2-1 & 2-2). 2. Be sure auxiliary latch of lock does not enter strike opening. 4-7/8 Fig 2-1 To frame on single door 1-5/16 3/8 1/8 DEEP 1/8 DEEP 1/8 DEEP 4.7 DIA DRILL #12-24 TAP LC of Strike P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 3 LC of Mortise Lock 4-7/8 Fig 2-2 To door edge of inactive door 1-5/16 3-3/8 1/8 DEEP 1/8 DEEP

3. SET LOCK HANDING A) Set the lock for proper handing to match door hand. 1) Change latch bolt handing: If the handing of the latch bolt doesn t match door hand, remove fixing screw and pull latch bolt out from lock case. Turn complete latch bolt unit around to match door handing. Reinstall latch bolt and fasten it in place (Fig 3-1 & 3-2). Remove screw Pull out and turn Fig 3-1 Fig 3-2 2) Set outside hand of lock case: There are two catch screws of lock hand on both sides of chassis. Take catch screw out from one side of chassis which is going to face outside of door (Fig 3-3). Another catch screw must always be on inside of chassis. For RH and RHRB, the catch screw will be on the lock case side. For LH and LHRB, the catch screw will be on the lock case cover side. Take a catch screw out from one side of the chassis which is going to be installed with a trim on the outside face of the door Fig 3-3 P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev B 02-17 Page 4

Check that the hub of the lock is seated in the correct position before proceeding to the next step. Insert spindle into hub of the lock case and turn until latch bolt is retracted (Fig 3-4). On the side of the lock case that is attaching to the trim, check that turning the spindle retracts the latch bolt before installing the lock case into the mortise cut-out. Fig 3-4 4. INSTALL LOCK CASE IN DOOR Insert lock case into mortise cut-out and fasten to door with two flat head screws (Fig 4) Fig 4 P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 5

5. INSTALL DEVICE: 1. Remove chassis cover from chassis assembly and end cap from end cap bracket. 2. Insert the Pull Finger beneath device chassis into the A hole in lock case (Fig 5-1) then mount device horizontally to the drilled position with 6 supplied screws to door (Fig 5-2). 3. Place end cap bracket as a template, mark and drill holes then screw it to secure the device. 4. Check device for correct operation: A. Depress Push Bar, latch bolt should retract to flush position. B. Release Push Bar, latch bolt is fully extended. 5. Tighten all screws and bolts. A Fig 5-1 Fig 5-2 P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 6

6. INSTALL OUTSIDE TRIM AND CYLINDER NOTE: Follow this step only if SDC s Entry Lever trim is used. If other trim is used with this device, please refer to the original manufacturers instructions. 1. Check the direction of the outside lever to be installed, then place the reversible spring cage into ferrules with the arrow pointing in the direction of the lever rotation and fasten with screws supplied (Fig 6-1). 2. Insert spindle into hub of spring cage on outside trim (Fig 6-2). Ferrule Mounting post Reversible spring cage Fig 6-1 Fig 6-2 3. Install outside trim with mounting posts through door and position spindle into hub of lock case (Fig 6-3) 4. Mount two long screws through device chassis into the mounting posts of outside trim. 5. Screw cylinder into threaded hole of lock case (Fig 6-4). 6. Tighten the set screw counter-clockwise against cylinder as shown. Fig 6-3 Fig 6-4 7. Install face plate onto lock case front and fasten with supplied screws (Fig 6-5). Fig 6-5 P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 7

7. TEST OPERATION AND INSTALL COVERS 1. Test push bar and dogging operation before installing covers: A. NO TRIM: Latch bolt is retracted by depressing push bar inside. B. WITH TRIM: Latch bolt is retracted by push bar inside, and; a) When outside key locks the lever/knob, the lever/knob will be made inoperative. b) When outside key unlocks the lever/knob, the lever/knob can retract the latch bolt. C. DOGGING: See dogging description and chart below. 2. Check and secure latch bolt engagement. Adjust strike if necessary. 3. Install chassis cover on chassis assembly. 4. Install end cap on end cap bracket. DOOR HANDING OUTSIDE OF DOOR Use this diagram to determine the handing of the door. RHR LHR MULLION INSIDE OF DOOR NOTE: For extending the life of this device, it is recommended utilizing the Dogging feature during high traffic periods of the day (Panic device only). Dogging: Depress push bar, insert dogging wrench and turn clockwise 15. Depress push bar Release Dogging: Depress push bar, insert dogging wrench and turn counter-clockwise 15. Depress push bar Dogging wrench (Allen key) The push bar will remain pressed and the latches will keep retracted. The push bar will return to the up position and the latches will project to lock the door. P:\INSTALLATION INST\Mechanical Hardware\INST-S6300.vsd Rev C 02-17 Page 8