Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Similar documents
Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 2 Series 9470/33

Analog Universal Module HART for Zone 2 Series 9468/33

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Fieldbus Isolating Repeater Series 9185/11

Isolators A3/1.

Binary Output without Power Supply Series 9176

Binary Output Series 9175

Remote I/O. 74 Remote I/O. Remote I/O System

Isolators A3/1. Vibration Transducer Supply Unit Series

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Digital I/O Coupler (4-wire) Series 9413/21

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolating Repeater Input Series 9163

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Single-Channel Safety Barriers Series 9001

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Head mounted Temperature Transmitter TF02/TF02-Ex

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Inductive sensor slot-type SI2-K08-AP7

onlinecomponents.com

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature transmitter itemp PCP DIN rail TMT 121

Field indicator for current loops with HART communication Models DIH50, DIH52

Technical Data. General specifications. Rated operating distance s n 3 mm

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Safety Instructions Nivotester FTC625, FTC325

Assembly. Front view. Switch Power Rail

Rail mounted Temperature Transmitter TH102/TH102-Ex

Technical Information Barrier RB223

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

A6500-UM Universal Measurement Card

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Preset counters, electronic

Assembly. Front view. Switch Power Rail

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Temperature Transmitter itemp RTD DIN rail TMT 127

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SALES SERVICE +358 (0)

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Positioner with HART Communication Type 3780

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Signal Beacon - LED Series 6162

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SINEAX TI 807 Passive DC signal isolator

Technical Information itemp TMT180

0 2 1 â Ó. itemp HART TMT182. Technical Information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature transmitter itemp RTD DIN rail TMT 127

Type Nominal voltage (V) Code HSV V

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Motor Protection Circuit Breaker Series 8146/5-V27

Certificate of Compliance

Pressure transmitter AKS 32 and AKS 33

Railbus isolator. Railbus isolator 8922-RB-IS

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

PRetrans Table of contents

Power supply. Calibration. Surface finishing. Seal. Process connection

RMA42. Technical Information

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Assembly. Front view. Power Rail

Field indicator for current loops with HART communication Models DIH50, DIH52

Type CP-S, CP-C & CP-A Switch mode

SISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Transcription:

> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels can be used as frequency inputs or counters up to 20 khz > Module can be replaced in operation (hot swap) www.stahl.de 04652E00 The Digital Input Module 24 V is used for the connection of up to 16 contacts with active 24 V signals. The inputs are passive voltage inputs for 0 / 24 V signals. All 16 channels have a common earth (0 V). Channels 14 and 15 are equipped with a fast comparator and can also be used for frequency measurement or as pulse counters up to 20 khz. Intrinsically safe power supply of the module via BusRail. The interface of the Digital Input Module with the internal data bus of the BusRail is designed with redundancy. ATEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex interface x x Ex interface x x Ex interface x x x Installation in x x *) Installation in x x *) Installation in x x *) x *) *) Restrictions see table explosion protection WebCode 9471A Remote I/O /1

Selection Table Version Description Order number Weight kg Digital Input Module 24 V Note 16 channels for active 0 / 24 V signals 9471/15-16-12 0.263 Please order terminal separately - see Accessories Explosion Protection Europe (ATEX) Gas and dust USA (UL) Gas Certifications and certificates Certificates Other approvals Safety data Maximum values KEMA 06 ATEX 0291 X E II 3 (2) GD Ex na [nl] [ib] IIC T4 3007532 (FM) NI/I/2/ABCD/T4 Ta = 65 C, I/2/IIC/T4 Ta = 65 C ATEX, Canada (CSA), Kazakhstan (TR), Russia (TR), Serbia (IZP), USA (FM), Belarus (TR) BV, ClassNK, DNV-GL, LR, RIVA, RS max. voltage U o 12.6 V max. current I o max. power P o 2.6 ma 8 mw or for connection to energy-limited Ex nl circuits with max. U i / V max = 32 V Cable parameters (ATEX) (for inductive or capacitive circuits) max. capacitance C o (IIC/IIB) max. inductance L o (IIC/IIB) 0.72 mf / 3.2 mf 20 mh / 50 mh or for connection to energy-limited Ex nl circuits with max. C i = 2.6 nf und L i = 0 mh Further information see respective certificate Digital inputs Number of channels 16 Voltage for ON / OFF > 13 V / < 5 V Max. voltage 32V Switching threshold approx. 8... 10 V Hysteresis approx. 2 V Internal resistance approx. 6 ko Minimum pulse width Channels 0-15 as digital inputs of the input signal If channels 14 or 15 are used as frequency input or counter approx. 1 ms approx. 2 ms Galvanic separation between power supply and system components between two input / output modules between inputs and system components The inputs of an I/O module have a common negative conductor. /2 Remote I/O

Frequency and counter inputs Number of channels 2 (channels 14 and 15) Maximum switching 20 khz, only with push-pull sensor *) frequency (the line length must be reduced for frequencies > 1 khz, e.g. at 5 khz to approx. 75 m) *) The inputs must be switched to + 24 V and 0 V. Schematic representation: 09272E00 Minimum pulse width Frequency input 25 ms Measuring range 1 Hz... 1 khz 1 Hz... 20 khz Resolution 0.05 Hz 1 Hz Accuracy 0.02 % 0.02 % adjustable parameters for each channel Counter input Control signal for Start, Stop, Reset counter Counter range 0...65535 Characteristic values Maximum signal delay from digital inputs to internal bus from frequency inputs to internal bus from counter inputs to internal bus channels 0-15 as digital inputs approx. 1 ms channels 14 or 15 as frequency input or approx. 2 ms counter measuring range 1 Hz... 1 khz for measurement frequency f = 1... 35 Hz 2 ms + 1/f measuring range 1 Hz... 1 khz for 34 ms + 1/f measurement frequency f = 35 Hz... 1 khz measuring range 1 Hz... 20 khz gate time 50 ms approx. 50 ms 200 ms approx. 200 ms 1 s approx. 1 s approx. 2 ms Settings Input Digital input (0... 15), frequency input (14 +15), counter input (14 + 15) Invert input value ON, OFF (all channels) Adjustable pulse width 0 s, 0.6 s, 1.2 s, 2.4 s (for channel groups) Gate time for 50 ms, 200 ms, 1 s (channels 14 and 15) frequency measuring range 1 Hz... 20 khz Active edge for counter (channels 14 and 15) Diagnostics Retrievable parameters Module faults Signal fault positive (voltage ) negative (voltage ) Manufacturer, type, version, serial number Internal primary bus faults Internal redundant bus faults No response Module does not correspond to configuration Hardware fault None Remote I/O /3

Operator interface Operation Fault Auxiliary power Maximum power consumption Maximum power dissipation Electrical connection Ex n field signals Connection diagram LED green "RUN" LED red "ERR" 1.4 W 1.4 W Plug-in terminals 16-pole with catch, 2.5 mm 2, screw or spring type X2 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Voltage signal 0/24 V 0 1 2 3... 15 +24 V 0V Ambient conditions Ambient temperature -20... +65 C Storage temperature -40... +70 C Maximum relative 95 % (no condensation) humidity Sinusoidal vibration (IEC EN 60068-2-6) Semi-sinusoidal shock (IEC EN 60068-2-27) Electromagnetic compatibility Mechanical data Module enclosure Fire resistance (UL 94) Degree of protection (IEC 60529) Modules Connections Mounting / Installation 1 g in frequency range between 10... 500 Hz 2 g in frequency range 45... 100 Hz 15 g (3 shocks per axis and direction) Tested according to the following standards and regulations: EN 61326-1, EN 61000-4-1...6, NAMUR NE 21 Polyamide 6GF V2 IP30 IP20 Installation conditions Mounting type on 35 mm DIN rail NS 35/15 Mounting orientation horizontal and vertical Engineering notes Combination of Zone 1 / Division 1 and Zone 2 / Division 2 modules on same BusRail is allowed. A partition (162740) is required to separate intrinsically safe and non-intrinsically safe circuits () 50 mm / 2 in). 05685E02 /4 Remote I/O

Accessories and Spare Parts Designation Figure Description Art. no. Plug-in terminal 09898E00 2.5 mm 2 with catch, 16-pole, screw connection, black, for connecting Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470, 9471 and 9480. 2.5 mm 2 with catch, 16-pole, screw connection, black, for connecting 162688 162714 09898E00 09899E00 2.5 mm 2 with catch, 16-pole, spring connection, black, for connecting including test jacks Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470, 9471 and 9480. 162700 2.5 mm 2 with catch, 16-pole, spring connection, black, for connecting including test jacks 162717 09899E00 Labelling strips "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 05869E00 DIN sheet For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 09900E00 Partition For assembly between intrinsically safe and non-intrinsically safe connectors of the I/O modules, in order to adhere to the required 50 mm distance 162740 * 02078E00 Remote I/O /5