Checked X.CAO

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Photometric Test Report

Photometric Test Report

Photometric Test Report

Test Sample Description Catalog Number: Description:

Equipment Used Model No Stock No Calibration Due Date

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Photometric Test Report

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Photometric Indoor Test Report

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

Photometric Test Report

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

QPL ID # PLG2YNJ831VZ

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

Photometric Test Report

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Calibration Due Date Chroma Programmable AC Source 61604

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

Eternal Shine Technology Co.,Ltd. EST

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

Morris Products 53 Carey Road, Queensbury, NY 12804

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

LM Test Report

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Photometric Test Report

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Dimming: PWM/TIME/0-5V/0-10V. RoHS

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS QPL ID # PLC6V1PABNUJS

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Lighting Sciences

Transcription:

REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER, FROSTED SIDE UP. LAMPS: ONE HUNDRED AND TWENTY WHITE LIGHT EMITTING DIODES (LEDS) VERTICAL BASE-UP POSITION. NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED. TOTAL INPUT WATTS = 29.171 W AT 277.0 VAC. *(SEE PAGE 2 FOR MORE INFORMATION)* CANDELA DISTRIBUTION FLUX 0.0 22.5 45.0 67.5 90.0 0 1181 1181 1181 1181 1181 5 1173 1172 1175 1179 1179 112 15 1129 1130 1135 1141 1144 320 25 1042 1045 1053 1063 1067 486 35 919 924 934 950 958 586 45 764 772 786 810 820 610 55 585 593 620 656 674 559 65 390 406 452 507 529 451 75 193 224 286 345 376 301 85 45 70 101 118 120 102 90 2 4 3 4 3 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0-30 918 26.0 0-40 1504 42.6 0-60 2673 75.8 0-90 3528 100.0 90-180 0 0.0 0-180 3528 100.0 TOTAL INPUT WATTS = 29.2 EFFICACY = 120.8 Lm/W CIE TYPE - DIRECT PLANE : 0-DEG 90-DEG SPACING CRITERIA : 1.2 1.3 PLANE : 0-DEG 90-DEG LUMINOUS LENGTH :23.000 23.000 LUMINANCE DATA IN CANDELA/SQ METER ANGLE AVERAGE AVERAGE AVERAGE IN DEG 0-DEG 45-DEG 90-DEG 45 3165. 3256. 3397. 55 2987. 3166. 3442. 65 2703. 3133. 3666. 75 2184. 3237. 4255. 85 1512. 3394. 4033. 400 800 1200 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: Checked Approved X.CAO D.WANG-MUNSON 90 75 60 45

REPORT NUMBER: RAB01842 PAGE: 2 OF 6 ADDITIONAL INFORMATION LED DRIVER: RDF25U7-32 TEST PROCEDURE: IESNA LM-79-08 ACCREDITED LABORATORY CODE 201058-0 TEST DISTANCE : 28.25 FEET NOTE: THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

REPORT NUMBER: RAB01842 PAGE: 3 OF 6 CANDELA DISTRIBUTION 0.0 22.5 45.0 67.5 90.0 0.0 1181 1181 1181 1181 1181 2.5 1177 1177 1179 1183 1184 5.0 1173 1172 1175 1179 1179 7.5 1166 1166 1170 1174 1174 10.0 1156 1157 1161 1167 1168 12.5 1144 1145 1150 1156 1158 15.0 1129 1130 1135 1141 1144 17.5 1110 1112 1117 1124 1127 20.0 1090 1091 1098 1106 1109 22.5 1067 1070 1076 1085 1090 25.0 1042 1045 1053 1063 1067 27.5 1016 1018 1028 1038 1044 30.0 986 989 999 1012 1018 32.5 955 958 969 983 989 35.0 919 924 934 950 958 37.5 884 888 902 918 925 40.0 846 852 865 883 892 42.5 806 812 828 847 856 45.0 764 772 786 810 820 47.5 723 731 746 772 782 50.0 678 686 704 733 747 52.5 632 641 661 695 710 55.0 585 593 620 656 674 57.5 537 547 578 620 641 60.0 487 500 535 583 605 62.5 437 452 492 545 568 65.0 390 406 452 507 529 67.5 339 361 412 465 487 70.0 289 314 373 422 445 72.5 240 270 330 384 408 75.0 193 224 286 345 376 77.5 149 183 243 307 333 80.0 109 143 204 256 278 82.5 74 105 157 195 208 85.0 45 70 101 118 120 87.5 22 33 36 36 32 90.0 2 4 3 4 3

REPORT NUMBER: RAB01842 PAGE: 4 OF 6 ZONAL LUMEN SUMMARY 0-5 28. 5-10 84. 10-15 136. 15-20 184. 20-25 226. 25-30 260. 30-35 285. 35-40 301. 40-45 307. 45-50 303. 50-55 290. 55-60 269. 60-65 242. 65-70 209. 70-75 171. 75-80 130. 80-85 80. 85-90 22.

REPORT NUMBER: RAB01842 PAGE: 5 OF 6 5-DEGREE 10-DEGREE ZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY 0-5 28 0-10 112 5-10 84 0-20 432 10-15 136 0-30 918 15-20 184 0-40 1504 20-25 226 0-50 2114 25-30 260 0-60 2673 30-35 285 0-70 3124 35-40 301 0-80 3425 40-45 307 0-90 3528 45-50 303 0-100 3528 50-55 290 0-110 3528 55-60 269 0-120 3528 60-65 242 0-130 3528 65-70 209 0-140 3528 70-75 171 0-150 3528 75-80 130 0-160 3528 80-85 80 0-170 3528 85-90 22 0-180 3528 90-95 0 95-100 0 100-105 0 105-110 0 110-115 0 115-120 0 120-125 0 125-130 0 130-135 0 135-140 0 140-145 0 145-150 0 150-155 0 155-160 0 160-165 0 165-170 0 170-175 0 175-180 0

REPORT NUMBER: RAB01842 PAGE: 6 OF 6 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119119119119 116116116116 111111111 106106106 102102102 100 1 108103 98 94 105101 96 93 96 93 90 92 90 87 89 86 84 82 2 98 89 82 76 95 87 81 75 84 78 73 80 76 72 77 73 70 68 3 89 78 69 63 86 76 68 62 73 67 61 70 65 60 68 63 59 57 4 81 69 60 53 79 68 59 52 65 58 52 63 56 51 60 55 50 48 5 75 61 52 45 73 60 52 45 58 50 45 56 49 44 54 48 44 41 6 69 55 46 39 67 54 46 39 52 45 39 51 44 39 49 43 38 36 7 64 50 41 35 62 49 41 35 48 40 34 46 39 34 45 39 34 32 8 59 46 37 31 58 45 37 31 44 36 31 42 35 30 41 35 30 28 9 56 42 34 28 54 41 33 28 40 33 28 39 32 27 38 32 27 25 10 52 39 31 25 51 38 30 25 37 30 25 36 30 25 35 29 25 23 ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS LUMINAIRE SAMPLE.

REPORT NUMBER: RAB01845 Page 1 of 4 DATE: 4/13/2016 CATALOG NUMBER: SWISH2X2-29YN/D10 ADDRESS: 170 LUDLOW AVE, NORTHVALE, NJ 07647 LUMINAIRE: LAMP: DRIVER: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER, FROSTED SIDE UP. ONE HUNDRED AND TWENTY WHITE LIGHT EMITTING DIODES (LEDS) VERTICAL BASE-UP POSITION. RDF25U7-32 OBJECT OF TEST: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT THE RATED INPUT VOLTAGES (277.0 AND 120.0 VAC, 60Hz) TO THE TEST SAMPLE. Calibration Due: INSTRUMENTS: GWINSTEK PROGRAMMABLE AC POWER SOURCE APS-7100 N/A CHROMA PROGRAMMABLE DIGITAL POWER METER MODEL 66202 2/26/17 OCEAN OPTICS QE65PRO Spectroradiometer 4/4/17 RAB 2.0 meter Diameter Integrating Sphere, 4PI Geometry 4/4/17 OBJECT OF TEST: PROCEDURE: *NOTE: RESULTS: Measure the Absolute Flux in lumens*, Total Radiant Flux*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14), Chromaticity Coordinates (x,y; u v ), ANSI C78.377 Duv, and electrical data including ANSI C82.77-2002 Power Factor (PF), and Total Harmonic Distortion (THD) to the test sample. Measure electrical data including Total Harmonic Distortion (THD) at maximum nominal rated input voltage. Report Off-State Power. The test sample was mounted inside the integrating sphere, energized, and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 60 HZ input in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM-79-08. Electrical data was also recorded at maximum nominal rated input voltage (120.0 VAC). All data are traceable to the National Institute of Standards and Technology. Off-State Power was reported with no voltage applied to the sample. Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results. (continued subsequent pages) Checked Approved X.CAO D.WANG-MUNSON Lighting Engineer THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: RAB01845 Page 2 of 4 DATE: 4/13/2016 CATALOG NUMBER: SWISH2X2-29YN/D10 RESULTS: PHOTOMETRIC Total Integrated Flux (lumens) SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u Chromaticity Ordinate v Correlated Color Temp CCT (K) ANSI C78.377-2008 Duv Total Radiant Flux (milliwatts) ELECTRICAL Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%) 3528 * CIE 1931 2 degree 0.4010 0.3840 CIE 1976 2 degree 0.2357 0.5078 3540-0.002 10941 * 277.0 0.114 29.2 92.1 12.4 0.2 COLOR RENDERING INDICES Ra (Average 1-8) R1 Light greyish red R2 Dark greyish yellow R3 Strong yellowish green R4 Moderate yellowish green R5 Light bluish green R6 Light blue R7 Light violet R8 Light reddish purple R9 Strong red R10 Strong yellow R11 Strong green R12 Strong blue R13 Light yellowish pink (skin) R14 Moderate olive green (leaf) CRI 85 84 91 96 84 84 88 86 66 19 79 84 71 85 98 EFFICACY (Lumens/Watt) 120.8 ELECTRICAL AT MAX NONIMAL INPUT Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%) 120.0 0.242 28.7 99.0 13.3 0.2 Off-State Power (Watts) 0.0 *NOTE: Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: RAB01845 Page 3 of 4 DATE: 4/13/2016 CATALOG NUMBER: SWISH2X2-29YN/D10 RESULTS: Wavelength mw per nm Wavelength mw per nm Wavelength mw per nm 380 0.251 515 35.546 650 37.969 385 0.268 520 36.984 655 34.168 390 0.258 525 38.378 660 30.570 395 0.288 530 39.875 665 27.080 400 0.345 535 41.502 670 23.877 405 0.428 540 43.211 675 20.898 410 0.676 545 45.027 680 18.183 415 1.354 550 47.137 685 15.787 420 2.810 555 49.332 690 13.616 425 5.592 560 51.279 695 11.736 430 10.253 565 53.420 700 10.053 435 17.796 570 55.483 705 8.621 440 29.524 575 57.518 710 7.383 445 47.520 580 59.479 715 6.322 450 59.698 585 61.345 720 5.397 455 45.350 590 63.093 725 4.602 460 29.516 595 64.104 730 3.923 465 24.064 600 64.425 735 3.343 470 18.942 605 64.377 740 2.854 475 15.516 610 63.562 745 2.445 480 16.212 615 61.951 750 2.101 485 18.576 620 59.574 755 1.786 490 21.672 625 56.716 760 1.534 495 25.356 630 53.153 765 1.317 500 28.991 635 49.403 770 1.128 505 31.765 640 45.634 775 0.972 510 33.904 645 41.801 780 0.148 67.5 Output vs. Wavelength 54.0 Output (mw/nm) 40.5 27.0 13.5 0.0 380.0 420.0 460.0 500.0 540.0 580.0 620.0 660.0 700.0 740.0 780.0 Wavelength (nm) THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: RAB01845 Page 4 of 4 DATE: 4/13/2016 CATALOG NUMBER: SWISH2X2-29YN/D10 CIE Chromaticity Diagram THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.