Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Similar documents
Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

Equipment Used Model No Stock No Calibration Due Date

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Calibration Due Date Chroma Programmable AC Source 61604

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Vista Professional Outdoor Lighting 1625 Surveyor Ave., Simi Valley CA Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE SANDRA STREET, FRANKLIN PARK, IL 60131

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement

U.S.T.E. dba Vista Professional Outdoor Lighting 1625 Surveyor Ave. Simi Valley CA Fixture is tested with no special conditions.

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506

Moon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506

EiKO Global, LLC W. 84th Street, Shawnee, KS 66227

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

No seasoning was performed in accordance with IESNA LM-79.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

ELATION LIGHTING 6122 S. EASTERN AVE, COMMERCE, CA Electrical and Photometric tests as required by the IESNA test standards.

MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards.

IES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED114DMV35.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : FHBC48-LED180DMV40.IES. DESCRIPTION INFORMATION (From Photometric File)

IESNA LM79: 2008 Photometric Test Report

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

NVLAP LAB CODE:

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

IESNA LM79: 2008 Photometric Test Report

IESNA LM79: 2008 Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

IESNA LM79: 2008 Photometric Test Report

Photometric Test Report

Photometric Test Report

IESNA LM79: 2008 Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

IESNA LM79: 2008 Photometric Test Report

Photometric Test Report

IESNA LM79: 2008 Photometric Test Report

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

REVOLUTION LIGHTING TECHNOLOGIES INC

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

Morris Products 53 Carey Road, Queensbury, NY 12804

Test Sample Description Catalog Number: Description:

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

NVLAP LAB CODE:

ApprovedMethod: Electricaland Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Photometric Test Report

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

Transcription:

Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063 Model Number: 202220-015 Test: Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is 202220-015. Received in working and undamaged condition. No modifications were necessary. Testing Condition: OSRAM SYLVANIA QHE 3X32T8/UNV ISN-SC driver was connected to three LED tubes from driver output. Photometric measurements were measured from a single LED tube while other two lamps were powered and covered with black velvet to prevent light pollution. Input power of single measured lamp is calculated from total power divided by three. Sample Arrival Date: Date of Tests: Seasoning of Sample: 11/13/15 11/17/15-11/18/15 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Model No Stock No Calibration Due Date Chroma Programmable AC Source 61604 PS-AC02 -- Yokogawa Digital Power Meter WT210 MT-EL06-S1 11/10/15 Xitron Power Analyzer 2801 MT-EL02-1 12/9/15 BK Precision DC Power Supply 1747 PSDC-04 01/08/16 Fluke Digital Thermometer 52k/J MT-TP02-GC 01/05/16 LLI Type C Goniophotometer System RMG-C-MKII CD-LL04-GC -- LLI 2M Sphere 2MR97 CD-SN03-S2 -- LLI Spectroradiometer SPR-3000 MT-SC01-S2 Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4

Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: 1323.40 Input Voltage (VAC/60Hz): 120.00 Input Current (Amp): 0.09 Input Power (W): 11.09 Input Power Factor: 1.00 Current ATHD @ 120V(%): 6% 202220-015 OSRAM SYLVANIA QHE 3X32T8/UNV ISN-SC Current ATHD @ 277V(%): 8% (0.04A, 11.19W, 0.97PF) Efficacy: 119 Color Rendering Index (CRI): 83 Correlated Color Temperature (K): 5110 Chromaticity Coordinate x: 0.3426 Chromaticity Coordinate y: 0.3562 Ambient Temperature ( o C): 25.0 Stabilization Time (Hours): 0:35 Total Operating Time (Hours): 1:10 Off State Power(W): 0.00 Revolution Lighting Technologies FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4

Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Percent Output 1.0 0.8 0.6 0.4 0.2 0.0 Spectral Power 380 430 480 530 580 630 680 730 780 Wavelength(nm) Wavelength W/m 2 nm 440 0.2811 510 0.4233 580 0.6246 650 0.2977 720 0.0428 380 0.0008 450 0.7784 520 0.4904 590 0.6171 660 0.2372 730 0.0318 390 0.0010 460 0.8473 530 0.5338 600 0.5921 670 0.1834 740 0.0235 400 0.0013 470 0.4851 540 0.5627 610 0.5558 680 0.1399 750 0.0174 410 0.0043 480 0.2858 550 0.5827 620 0.4909 690 0.1057 760 0.0130 420 0.0231 490 0.2600 560 0.6006 630 0.4256 700 0.0790 770 0.0098 430 0.0891 500 0.3276 570 0.6054 640 0.3611 710 0.0587 780 0.0074 CRI & CCT x 0.3426 y 0.3562 u' 0.2080 v' 0.4865 CRI 83.40 CCT 5110 Duv 0.00332 R Values R1 81.94 R2 90.05 R3 93.71 R4 80.85 R5 81.21 R6 84.43 R7 87.16 R8 67.88 R9 11.87 R10 74.54 R11 79.14 R12 57.75 R13 84.50 R14 96.50 Y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 510 500 490 520 480 530 470 460 440 430 380 CIE 1931 Chromaticity Diagram 540 550 560 570 0.3426, 0.3562 580 590 600 610 620 630 640 650 700 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4

Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(cct) and the color rendering index(cri) for each sample. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 10 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4

DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L111503505 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 11/18/2015 [MANUFAC] REVOLUTION LIGHTING TECHNOLOGIES [LUMCAT] 202220-015 [LUMINAIRE] 1"DIA. X 24"L. LED TUBE, DIFFUSED LENS [BALLASTCAT] OSRAM SYLVANIA QHE 3X32T8/UNV ISN-SC [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [_TEST CONDITION] OSRAM SYLVANIA QHE 3X32T8/UNV ISN-SC DRIVER WAS CONNECTED [MORE] TO THREE LED TUBES FROM DRIVER OUTPUT. [MORE] PHOTOMETRIC MEASUREMENTS WERE MEASURED FROM A [MORE] SINGLE LED TUBE WHILE OTHER TWO LAMPS WERE POWERED [MORE] AND COVERED WITH BLACK VELVET TO PREVENT LIGHT POLLUTION. [MORE] INPUT POWER OF SINGLE MEASURED LAMP IS CALCULATED FROM [MORE] TOTAL POWER DIVIDED BY THREE. [_INPUT] 120VAC, 11.09W [_TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp N.A. (absolute) Total Lamp Lumens N.A. (absolute) Luminaire Lumens 1323 Total Luminaire Efficiency N.A. Luminaire Efficacy Rating (LER) 119 Total Luminaire Watts 11.09 Ballast Factor 1.00 CIE Type Semi-Direct Spacing Criterion (0-180) 1.20 Spacing Criterion (90-270) 1.40 Spacing Criterion (Diagonal) 1.44 Basic Luminous Shape Rectangular w/sides Luminous Length (0-180) 1.69 ft Luminous Width (90-270) 0.08 ft Luminous Height 0.08 ft Page 1

LUMINANCE DATA (cd/sq.m) Angle In Average Average Average Degrees 0-Deg 45-Deg 90-Deg 45 17661 13027 13104 55 15772 11669 12181 65 13426 10593 11468 75 9959 9813 10946 85 3808 9498 10714 Page 2

CANDELA TABULATION 0.0 22.5 45.0 67.5 90.0 0 276.62 276.62 276.62 276.62 276.62 5 275.58 275.66 275.62 275.19 274.81 10 270.61 271.25 272.41 273.14 273.35 15 262.21 264.01 267.18 269.79 270.69 20 251.41 253.73 259.64 265.08 266.84 25 237.79 241.56 250.68 259.12 262.30 30 221.42 227.25 240.02 251.76 256.55 35 203.60 211.48 228.11 243.66 249.78 40 184.83 193.74 214.99 234.62 241.73 45 164.44 175.92 201.58 224.51 232.99 50 142.76 157.41 187.53 213.54 223.82 55 121.42 138.52 173.14 202.48 213.28 60 100.51 120.31 159.13 191.04 202.66 65 78.58 102.87 145.67 179.01 191.60 70 57.33 86.50 132.39 167.01 180.12 75 38.13 71.72 120.18 155.70 168.55 80 20.39 58.83 108.61 144.09 156.73 85 6.43 48.50 98.50 132.86 145.93 90 0.60 40.92 89.29 122.62 135.13 95 0.00 35.43 80.93 112.98 124.34 100 0.00 31.88 73.91 103.60 114.40 105 0.00 29.82 67.74 94.94 105.31 110 0.00 28.83 62.51 87.28 96.57 115 0.00 27.76 57.41 80.25 88.26 120 0.00 26.86 53.77 73.65 80.21 125 0.00 26.22 50.64 67.57 74.38 130 0.00 25.02 46.83 62.51 67.44 135 0.00 22.24 42.55 57.67 62.64 140 0.00 19.28 39.33 50.81 56.13 145 0.00 16.02 35.65 45.46 47.64 150 0.00 12.73 29.82 40.66 43.02 155 0.00 9.73 22.32 34.15 37.45 160 0.00 7.37 15.72 24.34 28.54 165 0.00 5.66 10.80 15.94 19.45 170 0.00 4.37 7.03 9.00 9.25 175 0.00 3.34 4.37 4.37 2.06 180 0.00 0.00 0.00 0.00 0.00 Page 3

ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 101.54 N.A. 7.70 0-30 216.99 N.A. 16.40 0-40 359.44 N.A. 27.20 0-60 666.78 N.A. 50.40 0-80 925.71 N.A. 69.90 0-90 1023.4 N.A. 77.30 10-90 997.21 N.A. 75.40 20-40 257.91 N.A. 19.50 20-50 412.55 N.A. 31.20 40-70 446.89 N.A. 33.80 60-80 258.93 N.A. 19.60 70-80 119.37 N.A. 9.00 80-90 97.69 N.A. 7.40 90-110 144.90 N.A. 10.90 90-120 197.08 N.A. 14.90 90-130 237.81 N.A. 18.00 90-150 286.64 N.A. 21.70 90-180 300.00 N.A. 22.70 110-180 155.10 N.A. 11.70 0-180 1323.4 N.A. 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 26.19 10-20 75.35 20-30 115.45 30-40 142.45 40-50 154.64 50-60 152.69 60-70 139.56 70-80 119.37 80-90 97.69 90-100 79.82 100-110 65.08 110-120 52.18 120-130 40.74 130-140 29.74 140-150 19.09 150-160 9.84 160-170 3.13 170-180 0.38 Page 4

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 114 114 114 114 108 108 108 108 99 99 99 90 90 90 81 81 81 77 1 101 95 89 85 95 90 85 81 82 78 74 74 71 68 67 64 62 58 2 90 81 73 67 86 77 70 64 70 64 59 63 59 55 57 53 50 47 3 82 70 61 54 77 67 59 52 61 54 49 55 50 45 50 45 41 38 4 75 62 53 45 70 59 50 44 54 46 41 49 43 38 44 39 35 32 5 68 55 46 39 65 52 44 37 48 40 35 43 37 32 39 34 30 27 6 63 49 40 33 59 47 38 32 43 36 30 39 33 28 35 30 26 24 7 58 44 35 29 55 42 34 28 39 32 26 35 29 25 32 27 23 21 8 54 40 32 26 51 39 31 25 35 28 23 32 26 22 30 24 21 18 9 50 37 29 23 48 35 28 22 32 26 21 30 24 20 27 22 18 16 10 47 34 26 21 45 33 25 20 30 23 19 28 22 18 25 20 17 15 Page 5

POLAR GRAPH 277 207 138 3 69 1 2 Maximum Candela = 276.62 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0-180) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (90-270) # 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) Page 6