SAS-551 Passive Monopole Antenna Operation Manual

Similar documents
SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

TDS-535 Tuned Dipole Set Operation Manual

SAS-543 Biconical Antenna Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

SAS Log Periodic Antenna Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

Current Probe Fixture Instruction Manual

AK-18G Antenna Kit Operation Manual

Bulk Current Injection Probe Test Procedure

Broadband Current Probe Series Operation Manual

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

Broadband Current Probe Series Operation Manual

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

Model 3106 Double-Ridged Waveguide Horn

Model 3148 & Log-Periodic Dipole Array Antenna

Model 3110B Biconical Antenna

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Advanced Test Equipment Rentals ATEC (2832)

Model 3116 Double-Ridged Waveguide Horn

TETRIS 1000 High Impedance Active Probe. Instruction Manual

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

MODEL 3810/2 Line Impedance Stabilization Network

Instruction Manual Model M Switch, DPDT, Manual Select

Model BiConiLog Antenna. User Manual

Log Periodic Dipole Array Antenna

Model 3142B BiConiLog Antenna

1523, 1524 Thermometer Readout User s Guide

TETRIS User's Guide. High Impedance Active Probe DO177-1

Copyright Teletronics International, Inc. Patent Pending

Instruction Manual Model Upconverter

SureCall TM CM800 65dB

Instruction Manual Model Upconverter

Model 3140B BiConiLog Antenna User Manual

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

SPM-50 RF Spectrum Power Meter PC Software User Manual

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Operator s Manual. PP016 Passive Probe

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

PHV RO High Voltage Passive Probe. Instruction Manual

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

PKT 512A-RO High Impedance Passive Cable Divider

o-ring grease can be used to hold the o-ring in the groove during installation.

Model 3180B Mini-Bicon Antenna User Manual

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Instruction Manual CT-6 High Frequency AC Current Probe

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Glass Electrode Meter

Log Periodic Antenna

860 DSP & 860 DSPi Multifunction Interactive Cable Analyzer. Section VI: Appendix

Model Biconical Antenna. User Manual

Model 1791 VHF Radio User's Manual

MANUAL. PCD - Precision Conical Dipole Antenna

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

PI-10 Broadband Power Indicator

AMP-13 OPERATOR S MANUAL

o-ring grease can be used to hold the o-ring in the groove during installation.

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

Microwave Meter. Instruction Manual

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

Instruction Manual Bandpass Cavity Filters 6 5/8 and 10 Diameter

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

2045 PAB700-FM-A1. Efficiency: 65% Temperature Range: -20 to 70 C Max VSWR: 2.5 :1. Class: Supply Voltage:

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Model 44L1/L1P BROADBAND RF WATT METER OPERATION MANUAL

VT1586A Rack Mount Terminal Panel Installation and User s Manual

TA MHz oscilloscope probe TA MHz oscilloscope probe

HydroLynx Systems, Inc.

Model 44A/AP BROADBAND RF WATT METER OPERATION MANUAL

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Model Biconical Antenna. User Manual

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

Double-Ridged Waveguide Horn Model 3115 User Manual

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Current Probes. User Manual

PI-150 Broadband Power Indicator

Soil Moisture Smart Sensors (S-SMx-M005)

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

Copyright Teletronics International, Inc. Patent Pending

LUDLUM MODEL 182 RADON FLASK COUNTER. June 2011 Serial Number PR and Succeeding Serial Numbers

Model 3104C. Biconical Antenna. User Manual

INSTALLATION AND OPERATING MANUAL

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

Instruction Manual Series-Notch Cavity Filters 6 5/8 and 10 Diameter

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

PCO-7114 Laser Diode Driver Module Operation Manual

50 Ohm Components Brochure

Transcription:

SAS-551 Passive Monopole Antenna Operation Manual 1

TABLE OF CONTENTS INTRODUCTION 3 SPECIFICATIONS 5 OPERATING INSTRUCTIONS 6 ANTENNA FORMULAS 8 CALIBRATION 10 MAINTENANCE 11 WARRANTY 12 2

INTRODUCTION Frequency Part Model Range Number Description SAS-551 9 khz 40 MHz 2348 Passive Monopole Antenna 3

INTENDED PURPOSES This equipment is intended for general laboratory use in a wide variety of industrial and scientific applications and designed to be used in the process of generating, controlling and measuring high levels of electromagnetic Radio Frequency (RF) energy. It is the responsibility of the user to assure that the device is operated in a location which will control the radiated energy such that it will not cause injury and will not violate regulatory levels of electromagnetic interference. RANGE OF ENVIRONMENTAL CONDITIONS This equipment is designed to be safe under the following environmental conditions: Indoor use Altitude: up to 2 km Temperature: 5 C to 40 C Maximum relative humidity: 80% for temperatures up to 31 C. Decreasing linearly to 50% at 40 C Pollution degree 2: Normally non-conductive with occasional condensation. While the equipment will not cause hazardous condition over this environmental range, performance may vary. 4

SPECIFICATIONS GENERAL DESCRIPTION The A.H. Systems passive monopole antenna is a general-purpose transmitting antenna which cover the 10 KHz 40 MHz frequency range. Each unit comes with a telescoping rod and ground plane. Review this manual and become familiar with all safety markings and instructions. ANTENNA SPECIFICATIONS SAS-551 Monopole Antenna specifications: Frequency Range...9 khz 40 MHz Maximum Continuos Power...1000 Watts Input Connector Type...BNC(f) Mounting Base...1/4-20 Tread(f) Weight...3.5 lbs. Size (W x H x D)...18" x 18" x 41" 46 cm x 46 cm x 104 cm 5

OPERATING INSTRUCTIONS ASSEMBLY INSTRUCTIONS To prepare the antenna for operation, attach the telescoping rod antenna element to the top of the ground plane box. Connect the rod antenna by pushing straight down on the female connector on top of the amplifier. Do not apply excessive sideways force, as this can cause the antenna center-pin to break. SETUP INSTRUCTIONS The ground plane can be mounted to any tripod with a 1/4-20 attaching stud. Extend the rod antenna to 41" (104 cm) above the ground plane. Connect the output BNC connector on the side of the antenna to the output of a 50 generator or amplifier. Establish a ground connection to the ground plane if required by the test specification. GENERAL USE INSTRUCTIONS The SAS-551 Monopole antenna is a passive antenna designed to transmit high electric fields This antenna may also be used as a passive receive antenna for testing in areas with high fields. Each antenna is individually calibrated per ANSI C63.5 (ECSM) and comes with a calibration certificate references the NIST traceable test equipment. The calibration tables shown provide a listing of the frequency of operation and its antenna factor in db/m. The field strength is the receiver voltage in db V plus the antenna factor (refer to the antenna factor calibration) plus any cable loss. When making a measurement, mount the antenna on an appropriate mast or tripod. 6

OPTIONAL EQUIPMENT The following is a recommend accessory list for the SAS-551 Passive Monopole Antenna: ECF-10 The ECF-10 is an equivalent capacitance fixture constructed per IEEE 291 and ARP 958. This is an indispensable tool used for gain adjustment and calibration of the active monopole antennas. The ECF-10 is used as a signal substitution source when calibrating the active monopole antennas. Refer to the calibration procedures below. SAC-210 Standard 3 meter BNC(m) to BNC(m) RF cable made with RG-58. Optional ferrite loading and custom lengths can be made to your specifications. Other cable types available upon request. Adapters Need an Adapter? We stock those as well. 7

CALCULATIONS EMISSIONS TESTING Individual calibration data for the passive monopole antenna is supplied to comply with various emissions test requirements. For emissions measurements, add antenna factor plus cable loss to receiver reading in db V to convert to field strength in db V/meter. Field Strength(dBuV/m) = SA(dBuV) + AF(dB/m) + cable loss (db) SA = Spectrum Analyzer or Receiver voltage reading AF = Antenna Correction Factor CL = Cable Loss in db IMMUNITY TESTING For Immunity measurements, the generated electric field strength can be calculated by: FS = Approximate Field Strength in (V/m) P = Power in watts g = Numeric Gain d = Distance in meters 8

LOG -> LINEAR VOLTAGE TYPICAL CONVERSION FORMULAS FIELD STRENGTH & POWER DENSITY db V to Volts V = 10 ((db V 120) / 20) db V/m to V/m V/m = 10 (((db V/m) -120) / 20) Volts to db V db V = 20 log(v) + 120 V/m to db V/m db V/m = 20 log(v/m) + 120 dbv to Volts V = 10 (dbv / 20) db V/m to dbmw/m 2 dbmw/m 2 = db V/m 115.8 Volts to dbv dbv = 20log(V) dbmw/m 2 to db V/m db V/m = dbmw/m 2 + 115.8 dbv to db V db V = dbv +120 db V/m to db A/m db A/m = db V/m 51.5 db V to dbv dbv = db V - 120 db A/m to db V/m db V/m = db A + 51.5 LOG -> LINEAR CURRENT db A/m to dbpt DBpT = db A/m + 2 db A to ua A = 10 (db A / 20) dbpt to db A/m db A/m = dbpt 2 A to db A db A = 20 log( A) W/m 2 to V/m V/m = SQRT(W/m 2 * 377) dba to A A = 10 (dba / 20) V/m to W/m 2 W/m 2 = (V/m) 2 / 377 A to dba dba = 20log(A) T to A/m A/m = T / 1.25 dba to db A db A = dba + 120 A/m to T T = 1.25 * A/m db A to dba dba = db A -120 E-FIELD ANTENNAS LOG -> LINEAR POWER Correction Factor db V/m = db V + AF dbm to Watts W = 10 ((dbm 30)/10) Field Strength V/m = 30 * watts * Gain numeric meters Watts to dbm dbm = 10log(W) + 30 Required Power Watts = (V/m * meters) 2 30 * Gain numeric dbw to Watts W = 10 (dbw / 10) LOOP ANTENNAS Watts to dbw dbw = 10log(W) Correction Factors db A/m = db V + AF dbw to dbm dbm = dbw + 30 Assumed E-field for db V/m = db A/m + 51.5 shielded loops dbm to dbw dbw = dbm - 30 dbpt = db V + dbpt/ V TERM CONVERSIONS dbm to db V db V = dbm + 107 (50 ) db V = dbm + 10log(Z) + 90 db V to dbm dbm = db V 107 (50 ) dbm = db V 10log(Z) 90 dbm to db A db A = dbm 73 (50 ) db A = dbm 10log(Z) + 90 db A to dbm dbm = db A + 73 (50 ) dbm = db A + 10log(Z) 90 db A to db V db V = db A + 34 (50 ) db V = db A + 20log(Z) db V to db A db A = db V 34 (50 ) db A = db V 20log(Z) Correction Factor CURRENT PROBES db A = db V db (ohm) Power needed for injection probe given voltage(v) into 50 load and Probe Insertion Loss (I L) Watts = 10 ((I L + 10log(V 2 /50))/10) 9

CALIBRATION Monopole Calibration The antenna factor for the rod antenna shall be determined by measuring the signal transfer characteristics of the matching device and assuming that the antenna is a short monopole with an infinite ground plane. Set up the monopole to be calibrated and the test equipment per Figure 3. Allow all equipment to warm up for 15 minutes. NOTES Figure 3 * Also referred to as a Dummy Antenna. If the VSWR of the receiver or signal generator is low, pads may not be needed or reduced to 6 db or 3 db. With the equipment connected as shown and a 50 termination on the T-connector (A), measure the received signal voltage V L in db V at the signal output port (B). Leaving the RF output of the signal generator unchanged, transfer the 50 termination to the signal output port (B) and transfer the receiver input cable to the T-connector (A). Measure the drive signal voltage V D in db V. Subtract V L from V D and add 6 db to obtain the antenna factor (in db) of the antenna. Records providing evidence that the required final inspection and tests are carried out shall be maintained and shall be available for review by the customer and third party inspectors. Such records include signed off ITPs, job cards, nonconformance reports, test reports and inspection reports, if any. NOTE The signal generator does not need to be calibrated, but it shall be stable. The 50 termination shall have low VSWR. The spectrum analyzer shall be calibrated and have low VSWR. 10

MAINTENANCE To ensure reliable and repeatable long-term performance, annual re-calibration of your active monopole preamplifier by A.H. Systems experienced technicians is recommended. Our staff can recalibrate almost any type or brand of antenna. For more information about our calibration services or to place an order for antenna calibration, visit our website at www.ahsystems.com or call (818) 998-0223. 11

WARRANTY INFORMATION A.H. Systems Inc., warrants that our Antennas, Sensors and Probes will be free from defects in materials and workmanship for a period of three (3) years. All other products delivered under contract will be warranted for a period of two (2) years. Damage caused by excessive signals at the product's input is not covered under the warranty. A.H. Systems' obligation under this warranty shall be limited to repairing or replacing, F.O.B. Chatsworth, California, each part of the product which is defective, provided that the buyer gives A.H. Systems notice of such defect within the warranty period commencing with the delivery of the product by A.H. Systems. The remedy set forth herein shall be the only remedy available to the buyer, and in no event shall A.H. Systems be liable for direct, indirect, incidental or consequential damages. This warranty shall not apply to any part of the product which, without fault of A.H. Systems has been subject to alteration, failure caused by a part not supplied by A.H. Systems, accident, fire or other casualty, negligence, misuse or normal wear of materials. Except for the warranty set forth above, there are no other warranties, expressed or implied, with respect to the condition of the product or it's suitability for the use intended for them by the buyer. For prompt service, please contact our service department for a Return Material Authorization Number before shipping equipment back to us. 12