Atomic and Nuclear Physics

Similar documents
Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

Atomic and nuclear physics

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Solid-state physics. Bragg reflection: determining the lattice constants of monocrystals. LEYBOLD Physics Leaflets P

Scintillation Counters

e t Development of Low Cost γ - Ray Energy Spectrometer

ORTEC Experiment 3. Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required. Purpose. Gamma Emission

PHYSICS ADVANCED LABORATORY I COMPTON SCATTERING Spring 2002

Experiment 10. The Speed of Light c Introduction Apparatus

5. Scintillation counters

5. Scintillation counters

Characterisation of SiPM Index :

Gamma Spectrometer Initial Project Proposal

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

AN ABSTRACT ON THE THESIS OF. David C. Vasquez for the degree of Master of Science in Radiation Health Physics presented on February 26, 2010.

Positron Emission Tomography

Ph 3455 The Franck-Hertz Experiment

Victoreen , H, A Gamma Scintillation Detector

1 Purpose of This Lab Exercise:

K 223 Angular Correlation

NM Module Section 2 6 th Edition Christian, Ch. 3

ORTEC Experiment 13. Gamma-Gamma Coincidence with Angular Correlation. Equipment Required

Atomic and nuclear physics LD. Fine structure of the characteristic x-radiation of an iron anode. Physics

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering

Energy Measurements with a Si Surface Barrier Detector and a 5.5-MeV 241 Am α Source

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

SECONDARY ELECTRON DETECTION

Users Guide GDM 10 Version 1.1

High collection efficiency MCPs for photon counting detectors

Photon Counters SR430 5 ns multichannel scaler/averager

Electronic Instrumentation for Radiation Detection Systems

Experiment 6: Franck Hertz Experiment v1.3

Nuclear Experiment Phys 318/317 Room 208 Instructor Richard Lindgren Room 302 Ext

CHAPTER 3 BASIC OPERATING METHODS OF PHOTOMULTIPLIER TUBES

arxiv:hep-ex/ v1 19 Apr 2002

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT

Instruction sheet VideoCom Retroreflecting Foil Falling Body for VideoCom. 1 Safety notes

SECOND HARMONIC GENERATION AND Q-SWITCHING

PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5)

Spontaneous Fission Spectrum of Neutrons from 252 Cf with Kinetic Energies Less than 1 MeV. Suraj Bastola. A senior thesis submitted to the faculty of


Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer

Fast first practical help -- detailed instructions will follow- preliminary Experiment F80

The Speed of Light Laboratory Experiment 8. Introduction

Name Class Date. Brightness of Light

Components of Optical Instruments

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

Radiation Detection Instrumentation

Secondary Electron Detector

EXPERIMENT 5. SCINTILLATION COUNTING AND QUENCH CORRECTION.

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

ORTEC Experiment 19. Gamma-Ray Decay Scheme and Angular Correlation for 60 Co. Equipment Required. Purpose. Introduction

GSI Helmholtzzentrum für Schwerionenforschung. Station Coincidence

PMT Calibration in the XENON 1T Demonstrator. Abstract

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Measuring Atlas Radiation Backgrounds in the Muon System at Startup: A U.S. ATLAS Upgrade R&D Project

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Moderne Teilchendetektoren - Theorie und Praxis 2. Dr. Bernhard Ketzer Technische Universität München SS 2013

arxiv:hep-ex/ v1 8 Jul 1999

Cosmic Ray Detector Hardware

MWPC Gas Gain with Argon-CO 2 80:20 Gas Mixture

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

GAMMA-GAMMA CORRELATION Latest Revision: August 21, 2007

TB-5 User Manual. Products for Your Imagination

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

Multichannel Analyser, Extended Version

MEDE3500 Mini-project (Day1)

--- preliminary Experiment F80

DEVELOPMENT OF HIGH STABLE MONITOR FOR MEASURERING ENVIRONMENTAL RADIATION

LEP Optical pumping

and N(t) ~ exp(-t/ ),

Experiment 1: The Wave Model of light vs. the Quantum Model

Advanced Materials Research Vol

Learning Objectives. Understand how light is generated in a scintillator. Understand how light is transmitted to a PMT

PX4 Frequently Asked Questions (FAQ)

CR Basics and FAQ. Overview. Historical Perspective

Instruction sheet

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Acoustic Doppler Effect

Chemical Engineering 412

PCS-150 / PCI-200 High Speed Boxcar Modules

DIODE LASER SPECTROSCOPY (160309)

experiment no. 3.5 Anti-Compton Spectroscopy

Peculiarities of the Hamamatsu R photomultiplier tubes

Scintillators as an external trigger for cathode strip chambers

Gamex CR 2.0 Program description and operating manual

DOE FUNDAMENTALS HANDBOOK INSTRUMENTATION AND CONTROL Volume 2 of 2

EKA Laboratory Muon Lifetime Experiment Instructions. October 2006

ORTEC ORTEC. Modular Pulse- Processing Electronics. What s in this Catalog? Who Needs this Catalog?

Radiation Test Report Paul Scherer Institute Proton Irradiation Facility

Experimental Physics I & II "Junior Lab" Fall Spring 2008

SPECTROMETRIC DETECTION PROBE Model 310. Operator's manual

LUDLUM MODEL MODEL AND MODEL GAMMA SCINTILLATORS. June 2017

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Transcription:

Atomic and Nuclear Physics Nuclear physics -spectroscopy LEYBOLD Physics Leaflets Detecting radiation with a scintillation counter Objects of the experiments Studying the scintillator pulses with an oscilloscope Determining the pulse heights as a function of the voltage at the photomultiplier of the scintillation counter Analysing the pulse-height distribution that corresponds to the absorption of monoenergetic radiation using a multichannel analyser Identifying the total-absorption peak and determining the half-width Identifying the Compton distribution Identifying the backscatter peak Principles The energy of radiation can be determined by means of a scintillation counter. The radiation interacts with the scintillator crystal and thus gives rise to light pulses which are transformed into voltage pulses by a photomultiplier. The number of emitted photons and the pulse height are proportional to the energy. Pulse-height analysis is performed by means of a multichannel analyser (MCA) which is connected to a computer (PC). NaI(Tl) scintillators NaI(Tl) is a common material for the construction of scintillation counters. Doping with thallium (Tl) provides for luminous Fig. 1 Diagram of a scintillation counter centres. Due to the iodine content, the detection probability for radiation is very high. The detection mechanism is initiated by an energy transfer to electrons which are then slowed down in the scintillator crystal. Pairs of populated states in the conduction band and unpopulated states in the valence band are released. The number of these electron-hole pairs is proportional to the absorbed energy E S, since the formation of an electron-hole pair always requires the same energy. The thallium atoms integrated in the crystal are ionized by interaction with holes produced during the slowing down of the primary electron. After subsequent recombination with an electron, they emit photons with an energy between 2.9 and 3.1 e. The number N S of photons is thus proportional to the absorbed energy E S. 0209-Sel 1

LEYBOLD Physics Leaflets Apparatus 1 set of radioactive preparations....... 559 83 1 scintillation counter............. 559 901 1 high voltage power supply 1.5 k..... 521 68 1 MCA-CASSY................ 529 780 1 MS-DOS-Connector L........... 524 001 or from..................... 524 007 1 stand rod, 47 cm.............. 300 42 1 Leybold multiclamp............. 301 01 1 universal clamp S.............. 666 555 additionally required: 1 PC with MS-DOS > 3.0 additionally recommended: 1 two-channel oscilloscope 303....... 575 211 1 BNC cable, 1 m long............ 501 02 The NaI crystal is transparent for the emission photons. In addition, the absorption of these photons by other thallium atoms is very unlikely as the concentration of thallium atoms is low. Moreover, the crystal is sealed against light in a housing made from strongly reflecting material. So a large part of the emitted photons reaches the attached photocathode of the photomultiplier. The emitted photons knock out electrons in the photocathode. Subsequently, the electron current is amplified in an avalanche-like manner through production of secondary electrons in a number of series-connected dynodes (see Fig. 1). The amplification factor for one dynode depends, among other things, on the potential difference between the dynodes and on the dynode material. The dynode potentials are tapped at a voltage divider that is fed with the heat and long-term stable high voltage. An amount of charge Q S proportional to N S reaches the anode. The corresponding anode current through a load resistor R A generates a voltage signal U S. U S is proportional to Q S if the decay time constant of the primary pulse is considerably larger than the time constant of the light emission by the excited thallium atoms ( = 0.23 s). Altogether, the pulse amplitude U S is thus proportional to the absorbed radiation energy E S. Multichannel pulse-height analysis The scintillator signals are then processed in a multichannel analyser, the central component of which is an analog-digital converter. The analog-digital converter measures the pulse height U S and converts the measuring value into a proportional digital value k S. More precisely, k S corresponds to a pulseheight interval, the width of which depends on the resolution of the analog-digital converter. The computer allocates a storage location for every digital value and counts the events at every storage location. The result is a histogram representing the pulse-height distribution. The histogram can be displayed graphically on the computer screen or in the form of a table. An energy calibration is required for a quantitative evaluation because the coefficients of the proportionalities E S N S Q S U S k S are at first unknown. Interaction of radiation with matter In the -energy range from 50 to 2000 ke two interaction processes of the radiation with the scintillator crystal play a predominant role. 1. Photoeffect: The quantum transfers its total energy E to an atom of the crystal knocking out a bound electron. Apart from the amount that corresponds to the binding energy, the energy turns into kinetic energy of the electron. This kinetic energy is transferred to the scintillator crystal by inelastic scattering. The ionized atom emits roentgen quanta or Auger electrons, the energy of which is, as a rule, also completely absorbed within the detector. This means that the total of the absorbed energy E S is equal to the energy E. In this case, the radiation is registered in the total-absorption peak (see Fig. 2). Safety notes Country-specific regulations must be observed, such as the Radiation Protection Regulation (StrSch) in Germany, when radioactive preparations are handled. The radioactive substances used in this experiment are approved for teaching purposes at schools in accordance with the StrSch. Since they produce ionizing radiation, the following safety rules must nevertheless be complied with: Prevent access to the preparation by unauthorized persons. Before using the preparation make certain that it is intact. With the object of shielding, keep the preparation in its safety vessel. To ensure minimum exposure time and minimum activity, take the preparation out of the guard vessel only as long as is necessary in order to perform the experiment. To ensure maximum distance, take hold of the preparation only at the upper end of the metal holder. Fig. 2 Histogram of a simplified pulse-height distribution corresponding to the absorption of monoenergetic radiation a Compton-distribution b total-absorption peak 2

LEYBOLD Physics Leaflets 2. Compton effect: In an elastic collision with an electron, a part of the energy turns into kinetic energy of the electron. The rest of the energy remains with the scattered quantum which, with a certain probability, leaves the crystal without further interaction. The energy E S absorbed in the detector then lies between 0 ke (forward scattering of the quantum) and a maximum value E C (backward scattering of the quantum), which is smaller than E. The primary quantum is registered in the Compton distribution (see Fig. 2). A large part of the scattered quanta is absorbed by the scintillator crystal in a second process through the photo effect. In this case, the energy E S absorbed by the detector is equal to E. The primary quantum is registered in the total-absorption peak. Setup The experimental setup is illustrated in Fig. 3. Mechanical setup: Clamp the stand rod with the Leybold multiclamp and the universal clamp on the back of the MCA-CASSY. Plug the connections of the photomultiplier into the detector base socket of the MCA-CASSY. Connection of the MCA-CASSY: Connect the MCA-CASSY with a high-voltage cable to the high voltage power supply and to the MS-DOS-Connector L with a flat line. Switch the MCA-CASSY on to activate the amplifier stage. Connection of the oscilloscope (if available): Connect the BNC socket EXTERN of the MCA-CASSY to channel I of the oscilloscope. Use the light shield of the oscilloscope or darken the room. Fig. 3 Experimental setup for the detection of radiation with a scintillation counter Carrying out the experiment a) Studying the scintillator pulses with an oscilloscope (if available): Clamp the set of radioactive preparations in the universal clamp with the outlet directed downward and align it so that the preparation is centred above the aperture of the scintillation counter at a distance of about 1 cm. Slowly increase the voltage of the high voltage power supply from 0 to 500 700 and study the voltage pulses with the following oscilloscope settings: time base: ca. 0.2 s/di. Y scan: 0.2 0.5 OLT/DI. coupling: DC zero line: upper edge of the screen trigger: (negative flank) ary the voltage, determine the height U S of the bright signal on the oscilloscope screen and record it. b) Studying the scintillator pulses with a multichannel analyser: Get the program MCA started. Choose Define settings in the main menu: resolution = 8 bit (256 channels) line diagram (confirm with <CR>) measuring time = 60 s Choose Record measurement in the main menu: choose spectrum = spectrum 1 Get the measurement started in the measurement screen with F1. Slowly increase the voltage of the high voltage power supply from 0 until pulses are counted around the middle of the screen. 3

LEYBOLD Physics Leaflets Erase the old measuring values with <Ctrl + C> and start a new measurement with <F1>. After finishing the measurement, change to Evaluate in graph in the main menu, switch the graphic cursor on with <F9>, determine and record the following form parameters of the total-absorption peak which are explained in Fig. 4: peak position peak height N max, half-width k 1/2 (accuracy ±0.1) integrated counting rate (area) N int. Repeat the measurement at other voltages (see Table 2). Table 1: The pulse height U S of the total-absorption peak as a function of the voltage at the photomultiplier U S 510 0.04 540 0.06 570 0.1 600 0.14 630 0.20 660 0.29 690 0.40 720 0.56 750 0.78 Fig. 4 Form parameters of the total absorption peak c) Recording a histogram: Select Define settings in the main menu: measuring time = 300 s Select the voltage so that the position of the total-absorption peak is at about k S = 220. Erase the old measuring values with <Ctrl + C>, and start a new measurement with <F1>. Fig. 6 The pulse height U S of the total-absorption peak signals Measuring example and evaluation a) Studying the scintillator pulses with an oscilloscope: Fig. 5 shows the pulse-height distribution on an oscilloscope screen. The signals with high counting rates correspond to the total-absorption peak of the monoenergetic radiation of Cs 137 (see Fig. 9). The dependence on the voltage can be seen from Table 1 and Fig. 6. b) Studying the scintillator pulses with a multichannel analyser: Table 2: Parameters characterising the total-absorption peak as functions of the voltage N max k 1/2 N int k1 2 Fig. 5 Oscilloscope presentation of th pulse-height distribution of the monoenergetic radiation of Cs-137 510 11.5 540 18 29000 3.8 118700 21.1 % 570 29 21100 4.1 103700 14.1 % 600 45.5 17300 5.5 100500 12.1 % 630 66 14000 6.4 97700 9.7 % 660 95 11500 7.7 95500 8.1 % 690 131.5 9100 9.5 93200 7.2 % 720 178 6600 13.3 93300 7.5 % 750 232 4400 19.7 92300 8.5 % 4

LEYBOLD Physics Leaflets In Table 2, the form parameters of the total-absorption peak are listed as functions of the voltage. Fig. 7 shows that if the voltage increases with the other measuring conditions being the same, then the peak height drops and the width broadens, whereas the area under the peak remains approximately constant. Thus the peak area is the only useful measure for the intensity of the registered radiation. Fig. 8 shows the dependence of the relative width k1 2 on the voltage. 100000 10000 1000 100 10 Fig. 9 Graph of the pulse height spectrum of radiation of Cs 137 1 500 600 700 c2) Compton distribution The energy of a quantum Compton scattered under the angle is Fig. 7 Fig. 8 The integrated number of counts N int (circles), the height N max (boxes) and the width k 1/2 as functions of the voltage K 1/2 K max 20% 10% 0% 500 600 700 The relative width k1 2 of the total-absorption peak as a function of the voltage E E = (I) E 1 + (1 cos ) m 0 c2 E : energy of the incoming quantum, E : energy of the scattered quantum, m 0 c 2 = 511 ke: rest energy of the electron For the Compton edge of the Cs 137 radiation one obtains E C = E E ( = 180 ) = 477 ke. This value corresponds to k = 159 in the histogram. The edge is smeared out in the histogram because the scintillation counter has a finite resolution and because events in the range between E c and E are also registered. c3) Backscatter peak There are also events in the histogram that go back to Compton scattering of quanta in the preparation. The scattered quantum is then absorbed in the scintillation counter. In the Compton scattering of the Cs 137 radiation at least the energy E B = E ( = 180 ) = 184 ke is transferred. This energy corresponds to k = 63. c) Recording a histogram: c1) Energy calibration For the energy calibration of the histogram shown in Fig. 9, a two-point calibration has to be made because the zero of the analog-digital converter cannot be precisely adjusted. The adjustment is made with the 662-ke radiation of the Cs 137 isotope (E = 662 ke, = 219) and the 60-ke radiation of the Am 241 isotope (E = 60 ke, = 21.7) which is admixed with the preparation. This results in E = 3.05 ke k 6.7 ke LEYBOLD DIDACTIC GMBH Leyboldstrasse 1 D-50354 Hürth Phone (02233) 604-0 Telefax (02233) 604-222 Telex 17 223 332 LHPCGN D by Leybold Didactic GmbH Printed in the Federal Republic of Germany Technical alterations reserved