* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager

Similar documents
RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

LK Wireless Room Control Cq

TYXIA 253. Installation and use. France:

COD GB / 1.0 RBAND/UMS - RBAND/CSM

RX-100. Drahtloser Programmierbarber Thermostat Betriebs-, Reinigungsund Wartungsanleitung für den INSTALLATEUR und den BENUTZER

RADIOBAND V3 Programming & Installation Manual

Wireless multizone receiver RDE-MZ6

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

INSTAT 868 Radio Frequency Single-Room Controls

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

200 RTH OFF ON IN OUT ALARM RESET

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Self-learning Room Temperature Controller Receiver

Power Meter Series PM3200 Functions and characteristics

WIRELESS Energy Monitor - Smart Meter

V22 Thermostat N515/R00( )

Control solutions Biofloor

DDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

User Instructions For TopTronic RS-10

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

WIRELESS 433MHZ WEATHER STATION

Data sheet. Function description. Benefits

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Control module 2 circuits AD290. Installation and Service Manual

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

R PROFLAME Instruction Book Collection

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

REE series digital interpolators

Digital Electronic Thermostat With RF

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Motor 1- GENERAL DESCRIPTION

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

Wireless Control Systems

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

02/11/2015

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual

Operating Instructions

02/11/2015

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Seite 2 Standard-Empfänger. EN Operation Instructions

433 MHZ TEMPERATURE STATION Instruction Manual

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

433 MHZ REMOTE THERMO

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

S-Series Digital Thermostat

Wireless 900 MHz Receiver

ECM3 EARTH CONTINUITY RELAY

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

SPA WIRELESS SWITCHES AND RECEIVERS MANUAL

Wireless Color Weather Station

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

WIRELESS 868 MHz WEATHER STATION

domovea energy tebis

Astra-R Kit Wireless Alarm System Operation Manual

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

Synthesized Transmitter

2016 Motorized Shades Basic Programming

Installation Guide. ECL Comfort 310, application A Table of Contents

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

CONTROL MANUAL. Dry-Pic 09PE - 09VE

Product and Applications Description

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

OEM WIRELESS DIALLER INSTALLATION & USER MANUAL. (Product No )

Quik Bridge Two- Channel Receiver Document Number: Rev. C September 1999

RF Remote Control Unit SEAV

JUMO Wtrans Receiver with Wireless Data Transmission

PRO Professional Radio Control Series Applications

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

RF converter WTX660-E05060

Comfort Digisystem User Manual. SecureStream Technology. Microphone DM05. English

ALPTEC POWER FACTOR CONTROLLER

Modbus communication module for TCX2: AEX-MOD

Transcription:

GP8 Radio CPL Radio DRIVER Energy manager Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions of the R&TTE Directive 1999/5/EC The EC declaration of conformity for this equipment is available, on request, from: "Technical information" department DELTA DORE - Bonnemain - 35270 Combourg (France) E-mail : info.techniques@deltadore.com *2702980_Ver.1* Amp. 90 CE 5 75 7,5 63 10 60 15 50 20 45 40 35 30 25 OK RF GP8 RADIO CPL Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed.

Warning Carefully read these instructions prior to installation. The unit must be installed in compliance with current standards. Always switch off the mains before installing or servicing the unit. Do not attempt to repair the unit yourself. After-sales service is available. The diagrams provided are simplified for greater clarity. Protective devices and other accessories required by the standards are not illustrated. Standard UTE NF C15-100 and good practice must be complied with. Connected or nearby units must not generate excessive interference (Directive 2004/108/EC). The GP8 RADIO PLC only works with a RADIO DRIVER type of wireless programmer. Contents Description........................... 5 Positioning the GP8 RADIO PLC............ 5 Connecting the GP8 RADIO PLC............ 6 Commissioning the GP8 RADIO PLC........ 10 Mounting / Positioning the RADIO DRIVER.... 12 Quick association of the GP8 PLC to the Radio Driver and PLC receivers....... 14 Setting the time on the RADIO DRIVER...... 17 Configuration........................ 18 Basic configurations (menu 1)............ 19 Programming type selection................. 19 Programming increment selection............ 19 Pilot Wire type selection.................... 20 DHW status in absence mode............... 20 Advanced configurations (menu 2)......... 21 Modification authorisation................... 21 Temperature correction..................... 22 Pilot Wire order selection................... 22 Tariff reduction selection.................... 23

Amp. CE OK 90 5 75 7, 5 63 10 60 15 50 45 40 35 30 2520 RF Contents Wireless/PLC association (menu R)......... 25 Accessing the wireless association menu....... 25 Home automation functions in the installation... 26 Consumption meter function................. 27 Access to PLC configuration................. 28 Associating a radio transmitter............... 29 Associating PLC transmitters................ 33 Associating PLC receivers.................. 34 Allocation of receivers on a three-phase system. 34 Re-associating PLC receivers................ 37 Associating a PLC receiver for DHW control.... 37 Configuration of the consumption indication function (Menu 3)............. 38 Consumption meter functions................ 38 Cost per kwh (inclusive of tax)............... 39 Deleting wireless associations............ 41 Restore factory settings................. 42 Wireless test......................... 43 Summary table of configurations........... 44 Load shedding....................... 46 Technical characteristics................. 47 Help............................... 49 Description Antenna Wireless LED Meter calibre adjustment PLC LED Amp. 90 CE 5 75 7,5 63 10 60 15 50 20 45 40 35 30 25 OK RF Load shedding LED GP8 RADIO CPL Load shedding type DHW LED Positioning the GP8 RADIO PLC GP8 RADIO CPL Electronic meter LED On = OK Flashing = Fault Off = Mechanical meter PLC removal button Wireless association button The modular unit is mounted on a DIN rail in the electrical cabinet. The antenna must be installed vertically and away from any metallic mass. - 5 -

Connecting the GP8 RADIO PLC Installation with an electronic meter Note: Please use at least a 10 A circuit breaker to protect the power supply of the GP8 RADIO PLC. 230 V supplied between terminals 3 and 4. The powerline carrier signals are received and transmitted through these terminals. Electronic meter Heating power supply Phase CT Current transformers The CT wire length can be extended by up to 1.5 m (for wire type H03VV-F or H05V-K). The CT does not have a connection polarity. It is possible to pass several conductors from the same phase through a single CT (maximum interior Ø10 mm). For an installation with a single-phase electronic meter, the CT option (ref. 6330004) is used for the consumption indication function of the heating and DHW consumption types. CT input 3 is not used. For an installation with an electromechanical meter, the CT option is only used for measuring excess consumption for load shedding. Single-phase: 1 CT Three-phase: 1 CT per phase (see section on load shedding) No consumption meter. The continuity wire must be earthed. 10A remote info 230 V power supply OP Day/night contact switch DHW DHW power supply Phase CT Domestic Hot Water - 6 - - 7 -

Connecting the GP8 RADIO PLC Three-phase connection Installation with an electromechanical meter L1 L2 L3 The phase connected to the meter's Off-Peak contact must be the same as the GP8 RADIO PLC power supply phase. T.I. Meter off-peak contact remote info 230 V power supply OP DHW Meter off-peak contact remote info 230 V power supply OP DHW 10A Domestic Hot Water 10A Domestic Hot Water Day/night contact switch Day/night contact switch Phase coupler 1 2 3 L1 L2 L3-8 - - 9 -

Commissioning the GP8 RADIO PLC Calibre selection If your installation is equipped with a conventional meter, select one of the calibres available (from 5A to 90A) depending on your specific EDF subscription. If your installation is equipped with an electronic meter, set the switch to CE (electronic meter). The calibre that is used is directly programmed on the meter. For a three-phase installation, the calibre chosen is that of the current available for each phase (and not for the 3 phases). e.g. Subscribed power kva Circuit breaker calibre CE 75 90 5 7,5 63 10 60 15 50 20 45 40 35 30 Amp. 25 (in amperes or in kva) Electronic meter display Configuring the load shedding Load shedding is configured using switches located on the upper connection terminal of the GP8 RADIO PLC. 1 2 3 4 Switch 1: Single-phase or threephase. For a three-phase installation with electromechanical meter, you must have 3 CTs (current transformers). Switch 2: Load shedding delay. The load shedding delay (about - Delayed 3 seconds) is used for applications - Immediate featuring a heat pump. 1 2 3 4 1 2 3 4 1 2 3 4 Switch 4: Load shedding test. Enables a rapid test of the load shedding when the system is installed (load restoration every 3 seconds). Must be reset to NORMAL after the test. (Load shedding time 1 to 2 minutes). To perform the load shedding test, the system must be put into power overload. - 3~ - 1~ - Cascade - Cascade-cyclic - Test - Normal Switch 3: Cascade or cascadecyclic load shedding. See load shedding section. - 10 - - 11 -

Mounting/Positioning the RADIO DRIVER For ease of use, the RADIO DRIVER can be installed: - on the wall, at a height of about 1.5 m, with screws/plugs, - on a base, placed on a piece of furniture or on a shelf. Attachment with screws Attach the base unit using screws and plugs suitable for the mounting surface or to a flush-mounting box, then close and lock the unit. Separate the unit from its base by unlocking it. Starting up Remove the protective tab from the batteries. The first time you activate the unit, you must set the clock. Fitting the unit to its base Position the unit on its base and lock it. 1 Position the thermostat 2 Lock the thermostat on its base - 12 - - 13 -

OK RF Amp. 90 CE 5 75 7,5 63 10 60 15 50 45 40 Quick association of the GP8 PLC to the Radio Driver and PLC receivers Load shedding channels For each receiver, you must specify the programming zone with which it is to be associated as well as its load shedding channel (from d1 to d8, d0 = no load shedding). Turn the dial to Press and hold the button for 5 seconds Press Configuration example PLC zone 1 PLC zone 2 PLC zone 3 Your configuration PLC zone 1 PLC zone 2 PLC zone 3 d0 Kitchen d0 Press 35 30 2520 Press GP8 RADIO CPL Press and hold for 3 seconds twice RF The RF LED flashes Press Press Press Press until the following screen appears Load shedding channel selection (see section on load shedding channels) N.B.: For three-phase systems, you must allocate to the load shedding channels: - d1 and d2, components powered by phase 1, - d3 and d4, components powered by phase 2, - d5, d6, d7 and d8, components powered by phase 3. - 14 - - 15 - d1 d2 d3 d4 d5 d6 d7 d8 Lounge Living room Living room 1 Corridor 1 Corridor 2 Bedroom 1 Bedroom 2 Bathroom 1 Bathroom 2 d1 d2 d3 d4 d5 d6 d7 d8

Put the receiver in association mode (see documentation) Validate on the receiver Press to configure zone 2 Setting the time on the RADIO DRIVER Days (1: Monday to 7: Sunday) Hours Minutes 1 Load shedding channel selection for zone 2 to configure zone 3 2 Validate on 2 Validate on the receiver the receiver Repeat steps 1 and 2 for each receiver in the zone. 1 Load shedding channel selection for zone 3 Turn the selector dial to. The days flash. Press + or - to set the day, then OK to confirm and go to the next setting. Repeat these steps to set the hours and minutes. To exit the time setting mode, turn the selector dial. To exit the configuration menu, turn the dial. - 16 - - 17 -

Configuration To enter the configuration menus, turn the dial to, then press and hold the i button for 5 seconds. 5 seconds Basic configurations (menu 1) Press the 1 button. The unit will offer a choice of 4 configurations: Unit reference (example: RADIO DRIVER 630) Basic configurations (Menu 1) To modify the various settings, press the + or - buttons, then press the OK button to confirm and go to the next setting. Information about unit version Configuration mode Advanced configurations (Menu 2) Consumption meter configuration (Menu 3)* Wireless association *Menu 3 is only accessible if the RADIO DRIVER is associated with a RADIO TYWATT or the consumption meter function of a GP8 RADIO PLC (see menu R). Programming type selection Programming increment selection Weekly (default) Daily 1 hour (default) 30 minutes 15 minutes - 18 - - 19 -

Pilot Wire type selection 6-order Pilot Wire (default) 4-order Pilot Wire Advanced configurations (menu 2) Press the 2 button. DHW status in absence mode DHW off (default) DHW in automatic After defining the settings for menu 1, the unit goes back to the list of menus. If you want to exit configuration, turn the selector dial to the right. To modify the various settings, press the + or - buttons, then press the OK button to confirm and go to the next setting. Change permission for user Programme changes allowed Programme changes not allowed - 20 - - 21 -

If there is a difference between the actual temperature (taken with a thermometer) and the temperature measured and displayed by the unit, function 2-02 can be used to compensate for the difference by changing the way the sensor takes measurements. Correction of temperature measured Correction possible by 5 C either way in increments of 0.1 C. Press the + or - buttons to change and press OK to confirm. Advanced configurations (menu 2) With the tempo rate Specific to and compatible only with the French electronic meter Tariff programming is used to select a lower temperature (reduced rate) in periods when electricity is most expensive (e.g. peak hours, red day). Example: if the temperature displayed by the unit is 19 C and the actual temperature is 20 C, adjust by +1 C and press OK to confirm. Tariff reduction selection in Comfort mode. Economy (default) Modérato (Comfort -2 C) Médio (Comfort -1 C) Comfort (no reduction) Specific to and compatible only with the French electronic meter Pilot Wire* order selection in Economy mode. Economy (default) Modérato (Comfort -2 C) Médio (Comfort -1 C) The electronic meter informs the GP8 RADIO PLC of the current price using the remote info line. Periods of tariff reduction can be programmed on your electronic meter (refer to the meter s instructions). *only for 6-order Pilot Wire Whatever the choice, the screen will display the symbol. - 22 - - 23 -

In the 2-06 configuration, the tariff reduction mode can never be lower than parameter 2.03 (see table): Tariff reduction Temporal Eco Economy (Configuration 2-06 = 0) Economy (Configuration 2-03 = 0) Economy Comfort - 2 C (Configuration 2-03 = 1) Comfort - 1 C (Configuration 2-03 = 21) Comfort - 2 C Comfort - 1 C Wireless/PLC association (menu R) This menu lets you associate all the installation s wireless products (transmitters and receivers) with the RADIO DRIVER. Enter the wireless association menu Comfort - 2 C (Configuration 2-06 = 1) Comfort - 2 C Comfort - 2 C Comfort - 1 C Comfort - 1 C (Configuration 2-06 = 2) Comfort - 1 C Comfort - 1 C Comfort - 1 C Comfort (Configuration 2-06 = 3) Comfort Comfort Comfort After defining the settings for menu 2, the unit goes back to the list of menus. If you want to exit configuration, turn the selector dial to the right. Press button R. - 24 - - 25 -

Home automation functions in the installation Up to 7 home automation products (alarm control unit, remote controls, etc.) can be associated for each of the heating zones + 7 products to act on all the heating zones (telephone transmitter, outdoor probe, etc.). Wireless/PLC association (menu R) Consumption meter function If the GP8 RADIO PLC is connected to the electronic meter, you have access to consumption indication. Menu r-01 can be used to declare these home automation functions. Compatibility with transmitters from the TYXAL, TYXIA Home automation functions on the installation No home automation functions Home automation functions associated with the RADIO DRIVER and TYDOM ranges (Delta Dore). Press + or to make your choice. Press OK to confirm and go to the next mode. Press + or to make your choice. Press OK to confirm and go to the next menu. Consumption meter function No consumption indication Consumption meter - 26 - - 27 -

Access to PLC configuration Access to PLC configuration No PLC configuration Access to PLC configuration The GP8 RADIO PLC controls PLC receivers. Press + or to make your choice. Press OK to confirm and go to the next menu. Wireless/PLC association (menu R) Associating a radio transmitter Step 1: Associate the GP8 RADIO PLC with the RADIO DRIVER. Press the button on the GP8 RADIO PLC for 3 seconds until the RF LED flashes slowly. Press and release the i button on the RADIO DRIVER. The screen displays 1. The GP8 RADIO PLC is associated with the RADIO DRIVER. If you do not have any home automation products, press the OK button until PLC is displayed and associate the PLC products. - 28 - - 29 -

1 2 3 4 5 6 7 8 9 0 # Step 2: Associating the home automation products. All zones Wireless/PLC association (menu R) Transmitter Door/window opening detector Window open: heating in Frost Protection mode Association To be associated zone by zone or for all zones (rad) Press the button. Number of associated transmitters The following menus are used to associate one or more transmitters, either with all zones (rad) or with one zone (zone rad 1, zone rad 2 or zone rad 3). Select the zone to associate by pressing OK. Telephone transmitter Remote control of the installation TYXAL control unit To be associated with all zones (rad) Enter the first 4 numbers of the access code (1234 by default), then press the button for 5 seconds. Zone 1 Number of associated transmitters - 30 - On the transmitter, confirm the association as indicated in the table or refer to the user guide. Each newly associated transmitter is displayed on the screen (number of transmitters). Monitoring alarm on: heating in Economy mode* Monitoring alarm off: heating in Comfort mode* *: until the next program change To be associated zone by zone Simultaneously press and hold the ON and OFF buttons of the unit s control device for 5 seconds to switch to maintenance mode. Open up the control unit and press test. Close the control unit. - 31 -

Transmitter Home automation remote control Comfort or Economy override TYXIA remote control Comfort or Economy override Outdoor sensor Indication of the outdoor temperature Association Press the domain button until the remote control emits a beep and the symbol flashes. Associate buttons and zone by zone. Press one of the tactile keys or. Associate buttons and for all zones (rad) Press one of the tactile keys or. To exit the association mode, press another domain button (e.g. ) To be associated zone by zone Simultaneously press and hold the buttons for 5 seconds. The LED comes on, goes off and then comes back on. Then release the buttons. To be associated with all zones (rad) Open the sensor s casing. Press the association button. The red LED will switch on then off. Close the sensor s casing. Wireless/PLC association (menu R) Associating PLC transmitters In PLC association, the OK LED of the GP8 RADIO PLC flashes. After a few seconds, the screen displays GE (GP8 RADIO PLC present). Associated PLC Typhone GP8 RADIO PLC present To associate a TYPHONE PLC, please consult its instructions. The association is indicated on the tlge screen. Press OK to move on to associating PLC receivers. To remove the association with a TYPHONE PLC, press init. Once the radio associations are made, press the OK button to confirm and go on to the next mode. - 32 - In this menu, no action is needed on the GP8 RADIO PLC. - 33 -

Associating PLC receivers (e.g. TC 51089) Programming zone Load shedding channel For each receiver, you must specify the programming zone with which it is to be associated as well as its load shedding channel (from d1 to d8, d0 = no load shedding). Allocation of receivers on a three-phase system - 34 - Load shedding channel selection Programming zone selection In three-phase installations, you must assign: - the components powered by phase 1 to load shedding channels d1 and d2, - the components powered by phase 2 to load shedding channels d3 and d4, - the components powered by phase 3 to load shedding channels d5, d6, d7 and d8. As a priority, the GP8 RADIO PLC resets the phases not affected by load shedding. Wireless/PLC association (menu R) If more than one receiver is associated with the same programming zone, it is recommended that they each be given a separate load shedding channel to prevent simultaneous load shedding (see section on load shedding). Press OK to select the programming zone (PLC zone 1, PLC zone 2 or PLC zone 3). Press + or - to select the load shedding channel. To exit configuration mode, turn the selector dial to the right. Example: Receivers A and B are associated with PLC zone 1. Receiver A: load shedding channel 1 Receiver B: load shedding channel 2-35 -

Associating receiver A. Programming zone selected: PLC 1. Press + or - to select the load shedding channel: d=1. On the receiver, the OK LED flashes slowly. Press and release the button. The green LED stops flashing. Receiver A is associated with PLC zone 1 and load shedding channel d1. Associating receiver B. Programming zone selected: PLC 1. Press + or - to select the load shedding channel: d=2 On the receiver, the OK LED flashes slowly. Press and release the button. The green LED stops flashing. Receiver B is associated with PLC zone 1 and load shedding channel d2. - 36 - Wireless/PLC association (menu R) Re-associating a PLC receiver For example, to modify its load shedding channel. Set the transmitter to PLC association mode (zone + load shedding channel). Press and hold the button on the receiver for 5 seconds until the OK LED begins to flash slowly. Press and release button on the receiver. The OK LED comes on steady. The receiver is associated. Associating a PLC receiver for DHW control To control the hot water tank using a suitable PLC receiver (e.g. TC 51098). From the PLC DHW screen. On the receiver, the OK LED flashes slowly. Press and release the button. The green LED stops flashing. The receiver is associated with the system. To exit configuration mode, turn the selector dial to the right. - 37 -

Configuration of the consumption meter function (Menu 3) Only if the GP8 RADIO PLC is connected to an electronic meter. Menus 3-12 to 3-18 are only available if you have declared the consumption meter function in menu R (r-02). Consumption meter function To display consumptions for heating, DHW and other uses, you must declare the number of CTs (current transformers, ref. 6330004) associated with the GP8 RADIO PLC option. Configuration of the consumption meter function (Menu 3) 3-13 to 3-18 kwh cost (incl. tax) The price displayed is the price per kwh (exclusive of subscription) expressed in euros including tax (price including city and local taxes and VAT (30% on average)). Number of CTs No partial consumption indication 1 CT (Heating) 2 CTs (Heating + DHW) Not used 0.11 (incl. tax) For more information, contact your electricity supplier. It is modified in increments of 1 euro cent. We recommend rounding to the nearest cent. For example: Euro 0.1085 is rounded to Euro 0.11. - 38 - - 39 -

Specific to and compatible only with the French electronic meter Configurations 3-13 to 3-18 allow you to modify the costs according to your subscription. Deleting wireless associations To cancel all wireless associations, turn the selector dial to, then hold down the i button for 5 seconds. Subscription option Base Double tariff tempo EJP Base HC Blue day OP Normal time - HP Blue day P Peak time - - White day OP - - - White day P - - - Red day OP - - - Red day P - Press and hold the R button for 5 seconds. P: peak time, OP: off-peak time After defining the settings for menu 3, the unit goes back to the list of menus. If you want to exit configuration, turn the selector dial to the right. IMPORTANT: the consumption displayed on your unit is for information only and is not binding. It does not replace the consumption displayed on your bill. Then press OK to confirm the reset. Turn the dial to the right to exit the reset. All the LEDs on the GP8 RADIO PLC flash. or - 40 - - 41 -

Restore factory settings The factory settings may be restored for each of the menus. Turn the dial to, then press and hold the i button for 5 seconds. Press and hold the button for the menu you want to reset for 5 seconds (example shown here for menu 1) Wireless test Turn the selector dial to, then hold down the 2 nd button from the top for 5 seconds until test is displayed. The RF LED of the GP8 RADIO PLC must flash each 5 seconds Then press OK to confirm the reset. or Turn the dial to the right to exit the reset. time a signal is received. If this is the case, radio transmission is occurring properly. Turn the selector dial or press OK to exit test mode. Otherwise, move your transmitter. Repeat these steps for the other menus. To exit the mode, turn the selector dial to the right. - 42 - - 43 -

Summary table of configurations 1-01 1-02 1-03 1-05 2-01 2-02 2-03 2-06 Type of program 0 = weekly 1 = daily No programming 0 = 1 hour 1 = 30 minutes 2 = 15 minutes Pilot Wire type selection 0 = 6 orders 1 = 4 orders DHW status in absence mode 0 = off 1 = automatic Change permission 0 = program changes allowed 1 = program changes not allowed Correction of temperature measured by 5 C either way in increments of 0.1 C. Pilot wire order during an Economy period 0 = Economy 1 = Modérato 2 = Médio Tariff reduction with tempo tariff 0 = Economy 1 = Modérato 2 = Médio 3 = No tariff reduction Consumption meter function 3-12 3-13 to 3-18 Number of CTs 0 = no consumption indication 1 = 1 CT (Heating) 2 = 2 CTs (Heating + DHW) 3 = 3 CTs (Not used) Cost per kwh according to subscription - 44 - Summary table of configurations Wireless and PLC association (Menu R) r-01 r-02 r-03 rad rad 1 to rad 3 PLC PLC1 to PLC3 DHW PLC Home automation functions 0 = No 1 = Yes Consumption indicators 0 = No 1 = Yes Access to PLC configuration 0 = No 1 = Yes Wireless association for all zones Wireless association for each zone Associating a PLC transmitter (e.g. TYPHONE PLC) Associating PLC receivers with the different zones and load shedding channels Associating a PLC receiver for DHW control - 45-

Load shedding Load shedding is used to reduce the contractual demand of the mains supply and to avoid tripping in the event of strong current draws. Load shedding starts as soon as the total current draw attempts to exceed the subscribed value. Load shedding is cascade or cascade-cyclic (cascadocyclique - registered trademark of DELTA DORE). In the event of overpower, GP8 RADIO PLC sheds load on all the channels then gradually brings them back into operation. Cascade load shedding According to the power overload, the unit restores load to the channels in a set order: Channel 1 Then channel 1 + channel 2, Then channel 1 + channel 2 + channel 3, etc. DHW (hot water tank) load is shed as a last resort, when excess demand makes it necessary. Cascade-cyclic (cascadocyclique ) load shedding (registered trademark of Delta Dore) Load shedding is performed by rotation on the 8 channels (cyclic) and adjusts the number of channels on which to shed load depending on the overpower (cascade). Cascade-cyclic (cascadocyclique ) load shedding enables better load shedding distribution. - 46 - Technical characteristics Wireless range: 100 to 300 metres outside, variable depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment) Radio frequency 868 MHz, class I (standard EN 300 220) Wireless remote control device Storage temperature: -10 C to +70 C Operating temperature: 0 C to +40 C Installation in an environment with normal pollution levels RADIO DRIVER room unit Power supplied by two LR03 or AAA alkaline batteries (supplied) Class III insulation Clock backup when replacing the batteries: 30 seconds Dimensions: LxHxD = 80 x 104 x 37 mm Protection rating: IP 30 Attachment with screws or on a base - 47 -

GP8 RADIO PLC modular unit 230 V +/-10%, 50 Hz power supply Consumption: 4 VA Class II insulation DHW output: 2A/230V Load shedding on up to 8 channels Circuit breaker calibres (conventional meter) from 5 A to 90 A PLC transmission frequency: 132.5 khz, FSK modulation Transmission power conforms to the CENELEC NF 50065 standard, class 122 1 remote information bus input (output from the electronic meter) Link with the meter: 6/10 single twisted pair cable with continuity wire, max. length. 100 m 1 off-peak contact phase input (conventional meter) Dimensions: 4 modules, h = 53 mm Relay contact break type: type 1.C brownout according to EN 60730-1 Current Transformer (ref. 6330004) Maximum permissible current: 100A No particular direction of assembly or polarity Connection: cable with minimum cross-section 0.75 mm 2, max. length 2 m (see Connecting the GP8 RADIO PLC section). - 48 - Help Nothing is displayed on the room unit screen. There is no power supply. Check the batteries. The i symbol flashes. A fault is detected on the installation. Press the button to view the fault(s). The unit displays: def7. Communication fault with the electronic meter. Check the connection with the meter. The unit displays: def8. Fault with the TYPHONE PLC. The receiver does not accept commands from the GP8 RADIO PLC. Check the transmission by performing a wireless test. Move your transmitter if necessary. Repeat the wireless association of the GP8 RADIO PLC with the RADIO DRIVER. The icon appears. The batteries are low. Change the batteries, making sure they are the right way round. You cannot associate a PLC receiver with the GP8 RADIO PLC. - Check that the RADIO DRIVER is in PLC mode, - Check that the OK LED of the GP8 RADIO PLC is flashing, - The receiver has already been associated. - 49 -

You wish to associate a home automation feature and the screen displays. You have reached the maximum number of functions to associate. The four LEDs (OK, RF, and are flashing. The GP8 RADIO PLC has not been configured. The unit displays the time and the temperature. The RADIO DRIVER is in standby mode. Press a button to wake it up. - 50 - - 51 -