LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Similar documents
LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Eternal Shine Technology Co.,Ltd. EST

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Cat# 71440A LED Classic Large Wall-Pack

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Dimming: PWM/TIME/0-5V/0-10V. RoHS

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS QPL ID # PLC6V1PABNUJS

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

QPL ID # PLG2YNJ831VZ

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

Cat# 71146A 150W Trunion Mount

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

71352A QPL ID # PLT2P2L2UNWR. RoHS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

Morris Products 53 Carey Road, Queensbury, NY 12804

Cat# LED High Bay

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

Cat# LED Classic MINI Wall-PACK

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)



71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

Cat# LED Wall-PACK

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

LM Test Report

LM Test Report

LM Test Report

LM Test Report

LM Test Report

Photometric Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Photometric Test Report

Photometric Test Report

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Photometric Test Report

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Cat# LED Classic Large Wall-Pack

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Transcription:

LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model name(s): 57-80W-XXK-WPH08-S Remark: XXK in the model name refers to CCT as below: 40K=4000K,45K=4500K,50K=5000K,57K=5700K Representative (Tested) Model: 57-80W-40K-WPH08-S 57-80W-57K-WPH08-S Model Different: All construction and rating are the same, except CCT Test & Report By: Bill Luo Engineer: Bill Luo Date: Aug.24,2017 Update:Oct.24,2017 update model names Review By: Manager: Tommy Liang Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 11

1.1 Product Information: Organization Name Builders Pack Brand Name Builders Pack Model Number 57-80W-XXK-WPH08-S SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Rated Voltage / Frequency 100-277Vac, 60Hz Nominal Power 80W Rated Initial Lamp Lumen -- Declared CCT 4000K,4500K,5000K,5700K LED Manufacturer ShenZhen JuFei Optoelectronics Co., Ltd. LED Model 2835 9V 1W White SMD LED Sample Number GZE1708048-C1(4000K), C2(5700K) Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Photo 2 / 11

1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction Aug.07,201 Aug.18,2017 1. Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Electrical Parameters 1. IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products 2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid State Lighting Products 3. CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering Properties of Light Sources 4. CIE 15-2004 Technical Report Colorimetry 5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source 6. IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD25 1.3 Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Chromaticity Measurement Sphere-Spectroradiometer Method: Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral power distribution taken at 5 nm intervals over the range of 380 to 780 nm. 3) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25ºC ± 1ºC. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 3 / 11

2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2017-08-18 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number 57-80W-40K-WPH08-S Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE170804 120.0 60 0.6690 79.97 0.9962 4.82 8-C1 277.0 60 0.3037 79.11 0.9405 12.55 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 82 R9 15 Frequency (Hz) 60 R2 89 R10 73 CCT (K) 3932 R3 93 R11 81 Duv -0.0011 R4 82 R12 60 Chromaticity (x, y) x=0.3827 y=0.3759 R5 82 R13 84 Chromaticity (u, v ) u'=0.2270 v'=0.5015 R6 84 R14 96 Color Rendering Index (CRI) 83.2 R7 87 R15 77 R9 15 R8 67 -- -- Photometric Measurement Goniophotometer Method: Parameter Result DLC V4.2 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 -- Total Luminous (lm) 10339 10171 >=10000(-10%) Luminous Efficacy (lm/w) 129.29 128.57 -- Total Luminous (lm)( 0-90 zone) 8431.2 8290.0 -- Luminous Efficacy (lm/w) ( 0-90 zone) Most Worst Luminous/Highest Watts 103.66 Zonal lumens in the 80-90 zone (%) 12.20 ( 0-90 zone) 105.43 104.79 Standard: >= Premium: >= 100(-3%) 120(-3%) -- <= 10(+3) Beam Angle ( ) 95.1 -- -- Center Beam Candle Power (cd) 2482 -- -- 4 / 11

Spectral Power Distribution & Chromaticity Diagram Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens %Total Zone Lumens %Total 0-30 1,619.4 15.7% 0-40 2,616.5 25.3% 0-60 4,945.2 47.8% 60-90 3,486.0 33.7% 70-100 3,053.5 29.5% 90-120 1,693.9 16.4% 0-90 8,431.2 81.5% 90-180 1,910.3 18.5% 0-180 10,341.5 100% 0-10 221.0 2.1% 90-100 822.6 8% 10-20 582.5 5.6% 100-110 550.8 5.3% 20-30 815.9 7.9% 110-120 320.5 3.1% 30-40 997.0 9.6% 120-130 142.4 1.4% 40-50 1,116.4 10.8% 130-140 50.4 0.5% 50-60 1,212.4 11.7% 140-150 16.6 0.2% 60-70 1,255.0 12.1% 150-160 5.1 0% 70-80 1,202.2 11.6% 160-170 1.4 0% 80-90 1,028.8 9.9% 170-180 0.5 0% 5 / 11

Photometric Data 6 / 11

7 / 11

2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2017-08-18 Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number 57-80W-57K-WPH08-S Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE170804 120.0 60 0.6589 78.77 0.9963 4.95 8-C2 277.0 60 0.2994 78.05 0.9412 12.38 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 82 R9 10 Frequency (Hz) 60 R2 89 R10 72 CCT (K) 5498 R3 92 R11 81 Duv 0.0026 R4 83 R12 58 Chromaticity (x, y) x=0.3325 y=0.3462 R5 82 R13 84 Chromaticity (u, v ) x=0.3325 y=0.3462 R6 83 R14 96 Color Rendering Index (CRI) 83.4 R7 88 R15 77 R9 10 R8 69 -- -- Photometric Measurement Sphere-Spectroradiometer Method: Parameter Result DLC V4.2 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 -- Total Luminous (lm) 10442 10282 >=10000 (-10%) Luminous Efficacy (lm/w) 132.56 131.74 -- Total Luminous (lm)( 0-90 zone) 8533 8366 -- Luminous Efficacy (lm/w) ( 0-90 zone) Most Worst Luminous/Highest Watts 106.21 108.33 107.19 Standard: >= Premium: >= 100(-3%) 120(-3%) 8 / 11

Spectral Power Distribution & Chromaticity Diagram 9 / 11

2.3 Performance Assessment: Model name CCT(K) Total Luminous Luminous Power (W) (lm) Efficacy (lm/w) 57-80W-40K-WPH08-S 4000K 10339 79.97 129.29 57-80W-45K-WPH08-S 4500K 10373 *1 79.37 *2 130.69 *3 57-80W-50K-WPH08-S 5000K 10407 *1 79.37 *2 131.12 *3 57-80W-57K-WPH08-S 5700K 10442 78.77 132.56 *1: This value is calculated and the calculation formula is as below: 10373=(10442-10339)/3+10339 10407=(10442-10339)/3+10373 *2: This value is calculated and the calculation formula is as below: 79.37=(79.97+78.77)/2 *3: This value is calculated and the calculation formula is as below: 130.69=10373/79.37 131.12=10407/79.37 10 / 11

3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R-331 2 meter Integrating Sphere 2017-07-01 2018-06-30 ST-R-327 Spectral analysis system HAAS-2000 2017-07-01 2018-06-30 D204 Standard Lamp 2017-07-12 2018-07-11 PF2010 Power Meter for Integrating Sphere 2017-07-01 2018-06-30 GO-R5000 Goniophotometer system 2017-07-01 2018-06-30 D908S Standard Lamp 2017-07-12 2018-07-11 PF210 Power Meter for Goniophotometer 2017-07-07 2018-07-06 Expand Uncertainty: Photometric Measurement (Sphere):2.04%, k=2 Chromaticity Measurement(Sphere):28.8K, k=2 Photometric Measurement(Goniophotometer):2.36%, k=2 ****** END OF REPORT ****** 11 / 11