The Best Relaytion. Cradle Relay W Rev. B EC-JM ECOC: JM10 1. Aug. 04

Similar documents
The Best Relaytion. Cradle Relay S Rev. B EC-JM ECOC: JM10 1. Aug. 04

The Best Relaytion. Cradle Relay N Rev. B EC-JM ECOC: JM10 1. Aug. 04

HF3 Relay (Preliminary)

MT4 Relay. The Best Relaytion

W11 Relay. The Best Relaytion

AXICOM Telecom-, Signal and RF Relays. D2n V23105 Relay Nov. 07 Rev A ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. HF3 Relay Aug. 08 Rev. E ECOC: JM10

AXICOM Telecom-, Signal and RF Relays. FX2 Relay Nov. 07 Rev. E ECOC: JM10

IM Relay Sept 06 Rev. F ECOC: JM10

MT4 Relay. 4 pole telecom/signal relay Through Hole Type (THT) Non-polarized. non-latching 1 coil. Features. Typical applications

onlinecomponents.com IM Series Signal Relays

Relay Types. Reed V23100-V4 Relay. Typical applications. Features. DIP version (flat) DIP version (high) SIL version.

PCB relay for DC voltage, polarized, monostable or bistable

MINIATURE RELAY 2 POLES, 2A HIGH INSULATION/WIDE GAP FTR-C1 Series

2-POLES 2A (SLIM PROFILE SIGNAL RELAY) FTR-B4 Series

To be Discontinued FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

PRODUCT DATASHEET. is brought to you by. SOS electronic distribution of electronic components

DISCONTINUED (2002) 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR12 SERIES MINIATURE RELAY FEATURES ORDERING INFORMATION

NA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS Compliant FEATURES ORDERING INFORMATION SAFETY STANDARD AND FILE NUMBERS

POWER RELAY. FTR-K3-WS Series. 1 POLE - High Capacity 25A Type FTR-K1 SERIES FEATURES

RF Signal Relays AXICOM. HF3 S Relay

JY SERIES 1 POLE 3, 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

POWER RELAY. FTR-K3-WG Series. 1 POLE - 25A - 1.5mm contact gap FTR-K1 SERIES FEATURES

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Miniature Power Relay MSR

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

RF Signal Relays AXICOM. HF3 Relay

PRODUCT DATASHEET. is brought to you by. SOS electronic distribution of electronic components

05/09/2014

SPST-NO SPDT DPST-NO DPDT

FTR-B4 Series ULTRA MINIATURE RELAY SLIM SIGNAL RELAY. RoHS Compliant FEATURES ORDERING INFORMATION

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

JY SERIES 1 POLE 3, 5 A (MEDIUM LOAD CONTROL) POWER RELAY. Lead Free / RoHS compliant* FEATURES ORDERING INFORMATION

2 POLES 8 A LOW PROFILE TYPE

MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

SY SERIES 1 POLE 1 A (FOR SIGNAL SWITCHING) MINIATURE RELAY SY SERIES. RoHS compliant

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

FBR46 SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY FEATURES ORDERING INFORMATION

RF Signal Relays AXICOM. HF3 S Relay

38 Series - Relay Interface Modules A

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

KRPA, KRP, KA, KR series

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

05/09/2012

VE 12 H M S E K HV VD (a) ( * ) (b) (c) (d) (e) (f) (g) (h) (i)

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

2 POLES 5 A LOW PROFILE TYPE

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

DISCONTINUED (2008) 4 Pole (2 FORM C+ 2 FORM A) Signal Relay for Central Switching/ Data Transmission FTR-B2 SERIES. RoHS compliant FEATURES

Model Number Structure

OMRON MK-I / -S RELAY

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Classification Enclosure rating Contact form Contact material

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Safety Monitoring Relays

10. Mini Coax Connectors

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

ultra MINIature 2-POLes 2a (LOW PrOFILe signal relay) Ftr-B3 series rohs compliant Features

10. Mini Coax Connectors

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Instantaneous Overcurrent Relay

UNIQUELY DESIGNED RELAY FEATURES

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

JS SERIES 1 POLE 8 A (MEDIUM LOAD CONTROL) POWER RELAY. Lead Free FEATURES ORDERING INFORMATION

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Product Data Sheet 3252J/2H3PU

Relay interface modules A

COMPACT PC BOARD POWER RELAY

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

Safety Relay H-462. Dimensions LxWxH(in mm) Size 1: 57,8 x20,5 x48,6 Size 2: 67,4 x20,5 x48,6

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

SPECIFICATIONS Contact Form 2 Form C Maximum switching power 30 W (resistive) 62.5 VA (resistive) Contact Ratings Maximum switching voltage 220

Song Chuan / Relay Catalog 507

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Product Data Sheet RG160-28/18N/2TDPU-331

38 Series - Relay interface modules A. Features /

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

SPST-NO SPDT DPST-NO DPDT

02/11/2015

Transcription:

The Best Relaytion Cradle Relay W 08-9803 Rev. B EC-JM00-0009-03 ECOC: JM0. Aug. 0

Hand solder and plug-in relay, for AC operation, non-polarized, non-latching Features highly reliable great variety of contact arrangements and materials to meet specific applications Contacts for signal loads and currents up to 5 A Sockets for easy and quick mounting of relays (see data sheet Accessories) Typical applications Versions Size I or II, depending on height of the contact set Various contact arrangements available: max.. changeover contacts, 2 break contacts or 2 make contacts Single or bifurcated contacts Hand solder terminals, for plug-and-socket connection, screw fixing Dust-protected Operation of the coil with alternating voltage Machine controls European Directive conformance: Cradle W relay product conformance according to: - Directive 2000/53/EC: ELV (End of Life of Vehicles) - Directive 2002/95/EC: ROHS (Restrictions of the use of certain hazardous substances in electrical and electronic equipment) Compliance is evidenced by written declaration from all raw material suppliers. Tyco Electronics AXICOM only has responsibility for the proper processing of these materials. Confirmation is valid for date codes 050 Page 2 (9) 08-9803 Rev. B

Version -A0xxx Size I and -B0xxx Size II With hand solder terminals, silver-plated Also for plug-and-socket connection plus screw fixing With earth terminal Dust-protected Dimension drawing (in mm) Size I Size II Page 3 (9) 08-9803 Rev. B

Contact Data B0/B0 B60/B60 C0/C0 C0/C0 F0... F07 Type of contact Contact assembly Contact material Max. switching voltage Max. switching current Max. switching capacity Max. continuous current at max. ambient temperature max. changeover contacts, 2 break contacts or 2 make contacts bifurcated contacts silver, gold F silver, gold F silver, gold-flashed gold-flashed gold-flashed 50 Vdc 36 Vdc 50 Vdc 36 Vdc 250 Vdc 25 Vac 30 Vac 25 Vac 30 Vac 250 Vac 2 A 0.2 A 2 A 0.2 A 5 A 35 to 70 W 5 W 35 to 70 W 5 W 50 to 0 W see load limit 5 VA see load limit 5 VA see load limit curve page 5 curve page 5 curve page 5 50 VA 50 VA 500 VA 2 A 5 A Contact sets Size I Number of contacts and type Symbols with base conncections 2 changeover contacts 2 make contacts 2 break contacts break make contact Contact assembly Contact material silver, gold-flashed Contact material gold F single contacts B0 B60 bifurcated contacts C0 C0 F05 F07 F06 Size II Number of contacts and type Symbols with base conncections changeover contacts 2 changeover contacts Contact assembly Contact material silver, gold-flashed Contact material gold F B0 B60 bifurcated contacts C0 C 0 F 0 Page (9) 08-9803 Rev. B

Coil Data Nominal voltage Typical nominal power consumption, at 20 C Class of the operative range acc to EN 680- / IEC 680- and VDE 035 Part 20 Operating voltage (according to the coil type) from 6 Vac to 220 Vac.5 W max. 80% of the nominal voltage Coil version Nominal voltage U nom Vac DC resistance at 20 C Terminals Coil number Ordering code block 2 (50 Hz / 60 Hz) W Start End 6 2 2 8 60 0 220 8 ± 0.8 0 ±.0 70 ± 7 620 ± 62 000 ± 00 3200 ± 80 000 ± 200 05 07 00 09 008 007 00 At 70 C ambient temperature the operating voltage is permitted to deviate from the rated values by + 0% and - 20%. Load limit curve Safe breaking, no stationary arc Contact material silver, gold-flashed Contact sets Bxx and Cxx Contact sets Fxx Page (9) 08-9803 Rev. B

General data Maximum switching rate without load Ambient temperature range acc. to EN 680- / IEC 680- and VDE 035 part 20 Thermal resistance Maximum temperature Continious thermal load Degree of protection acc. to EN 60529 / IEC 60529 / VDE 070 part Mechanical endurance Mounting position Weight Size I Size II Bxx B6xx Cxx Cxx Fxx 20 operations/s -0 C... +70 C 35 K/VA 00 C 2.2 VA dust-protected IP 0 approx. 0 7 operations approx. 0 8 operations any approx. 35 g approx. 0 g Insulation Test voltage ( min) winding / frame contact / contact contact / frame Bxx B6xx Cxx Cxx Fxx 500 Vac rms at nominal voltages 60 V 500 Vac rms at nominal voltages > 60 V 500 Vac rms 000 Vac rms 000 Vac rms 000 Vac rms Page 6 (9) 08-9803 Rev. B

Ordering Code Digit Block Block 2 Block 3 2 3 5 6 7 8 9 0 2 3 5 V 2 3 0 0 5 Basic type number of cradle relay W Relay type A0 = Size I B0 = Size II Coil number Versions see page 5 Contact set / type of contact see page Ordering example: -B00-F0 Cradle relay W, size II, coil 220 Vac, 2 changeover contact set,, contact material silver, gold-flashed Note: The ordering scheme enables a multitude of variations. However, not all variations are defined as construction specifications (ordering code) and thus in the current delivery program. Special design can be carried out to customer specifications. Please contact your local representative. Ordering Information Relay Code Tyco Part Number A B0 0-39386- B B0 2-39386-2 B F0 2-39386-8 B 7B0 3-39386-0 B 0B0-39386-0 B 0F0-39386-3 Page 7 (9) 08-9803 Rev. B

IM Relays th generation slim line low profile polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with coil. Nominal voltage range from.5... 2 V, coil power consumption of 0... 200 mw, latching relays with coil 00 mw. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 089 (2,5 kv 2 / 0 µs) and FCC part 68 (,5 kv 0 / 60 µs). The IM relay is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL950. Dimensions approx. 0 x 6 mm board space and 5.65 mm height. P2 Relays 3 rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with or 2 coils. Nominal voltage range from 3... 2 V, coil power consumption 0 mw, latching relays with coil 70 mw. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Bellcore requirements according GR 089 (2,5 kv 2 / 0 µs) and FCC part 68 (,5 kv 0 / 60 µs). Dimensions approx. 5 x 7,5 mm board space and 0 mm height. FX Relays 3 rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with coil. Nominal voltage range from 3... 8 V, coil power consumption of 80... 260 mw for the high sensitive version, 0... 300 mw for the standard version, latching relays with coil 00 mw. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 089 (2,5 kv 2 / 0 µs) and FCC part 68 (,5 kv 0 / 60 µs). The FX2 is CECC/ IECQ approved and certified in accordance with IEC/EN 60950 and UL950. Dimensions approx. 5 x 7,5 mm board space and 0,7 mm height. FT2 / FU2 Relays 3 rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3... 8 V, coil power consumption 200... 300 mw. Most sensitive 8 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Bellcore requirements according GR 089 (2,5 kv 2 / 0 µs) and FCC part 68 (,5 kv 0 / 60 µs). The FT2/FU2 is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL950. Dimensions approx. 5 x 7,5 mm board space and 0 mm height. FP2 Relays 3 rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with or 2 coils. Nominal voltage range from 3... 8 V, coil power consumption of 80... 260 mw for the high sensitive version, 0... 300 mw for the standard version, latching relays with coil 00 mw.. The FP2 Relay is available as through hole type and capable to switch loads up to 30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (,5 kv 0 / 60 µs). The FP2 is CECC/IECQ approved. Dimensions approx. x 9 mm board space and 5 mm height. MT2 / MT 2 nd generation non polarized, non latching 2 c/o and c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from.5... 8 V, coil power consumption 50/200/300/00 and 550 mw, and 300 mw (MT). Dielectric strength fulfills the requirements according FCC part 68 (,5 kv 0 / 60 µs) for both and the Bellcore requirements according GR 089 (2,5 kv 2 / 0 µs) the MT only. Dimensions MT2 approx. 20 x 0 mm board space and mm height, MT approx. 20 x5 mm board space and mm height. D2n Relays 2 nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3... 8 V, coil power consumption from 50... 500 mw. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (,5 kv 0 / 60 µs). Dimensions approx. 20 x0 mm board space and,5 mm height. P Relays Extremely sensitive, polarized c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with or 2 coils. Nominal voltage range from 3... 2 V, coil power consumption 65 mw, latching relays with coil 30 mw. The P relay is available as through hole or surface mount type and capable to switch currents up to A. Dielectric strength fulfills the requirements according FCC part 68 (,5 kv 0 / 60 µs). Dimensions approx. 3 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. W Relays Low cost, non polarized c/o relay for various applications. Nominal voltage range from 3... 2 V, coil power consumption 50 mw, sensitive versions 200 mw. The W relay is capable to switch currents up to 3 A. Dielectric strength 000 Vrms. Dimensions approx. 5,6 x 0,6 mm board space and,5 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with n/o, 2 n/o or c/o contacts. Nominal voltage range from 5... 2 V, coil power consumption 50...280 mw for n/o and 25... 280 mw for 2 n/o or c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 500 Vdc. Dimensions approx. 9,3 x 7 mm board space and 5... 7,5 mm height for DIP or 9,8 x 5 mm board space and 7,8 mm height for SIL version. Cradle Relays Extremely reliable and mature relay family of st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 9 x 2 to 9x35 mm board space and 30 mm height. Other Relays We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 / V2303 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063... V23067 and V2363... V2367 series). Accessories like sockets, hold down springs, etc. optional. HF3 Relay High performance low cost RF relay with excellent RF characteristics. Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small size, excellent RF performance and SMD solderability. Available as non latching or latching relay with or 2 coils and a nominal coil voltage range from 3... 2 V, coil power consumption 0 mw, latching relays with coil 70 mw. Dimensions.6 x 7.3 x 0 mm. Page 8 (9) 08-9803 Rev. B

Tyco Electronics AXICOM Ltd. Seestrasse 295 - P.O. Box 220 CH-880 Au-Wädenswil / Switzerland Phone + 782 9 Fax + 782 9080 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-3629 Berlin / Germany Phone +9 30 386 38573 Fax +9 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 82 CZ-5 0 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com Tyco Electronics Corporation POB 3608, Harrisburg, PA 705, USA Phone +00 800-522-6752 Page 9 (9) 08-9803 Rev. B