INSTRUCTIONS MODEL AVX-TFR-STUD TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

Similar documents
INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODEL AVX-S1-P0D-MS1A PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

INSTRUCTIONS AVX-FILT SERIES OF RISE TIME FILTERS FOR USE WITH AVR-EBF6-B TFR TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

AVTECH TECHNICAL BRIEF 15 (TB15) A COMPARISON OF REVERSE RECOVERY MEASUREMENT SYSTEMS

INSTRUCTIONS MODEL AV-1000-C ±10 VOLT / TTL / ECL GENERAL PURPOSE PULSE GENERATOR SERIAL NUMBER:

INSTRUCTIONS MODEL AVM-1-C. 5 VOLT, 25 MHz HIGH SPEED PULSE GENERATOR. WITH 100 ps RISE TIME SERIAL NUMBER:

PSC Power Paddle II Antenna

SCXI MHz Quad 8x1 50 Ω Multiplexer

3M Mini D Ribbon (MDR) Cable Assembly.050" High Speed Digital Camera Link Cable Right Angle 14H26-SZLX-XXX-0LC

1480nm Pump Laser Diode Module Component Specifications (with Isolator, RoHS6/6)

Operator s Manual. PP016 Passive Probe

PSC Power Paddle Antenna

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

TETRIS 1000 High Impedance Active Probe. Instruction Manual

NI PXI/PXIe-2540 Specifications

AM3089 Filter Bank. Description. Functional Diagram. Features. Characteristic Performance. Analog Tunable 2.0 to 18.0 GHz Bandpass

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

NI PXI-2557 Specifications

PKT 512A-RO High Impedance Passive Cable Divider

BROADBAND LINEAR AMPLIFIER Model P150

NI PXI-2555 Specifications

3M Shrunk Delta Ribbon (SDR) Cable Assembly.80 mm High Speed Digital Data Transmission, 26 position 1MG26-LFW0-00C-XXX

The SCX18.S provides dual high power regulators capable of supplying 3A to the connected servos from an external Li-Pol or

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

3M Mini D Ribbon (MDR) Cable Assembly.050 High-Flex Digital Camera Extension Cable 26 position 1WL26-TZ3B-XXX-04C

NI PXIe-5601 Specifications

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

PHV RO High Voltage Passive Probe. Instruction Manual

Operator s Manual. PP017 and PP018 Passive Probes

INSTRUCTIONS MODEL AVOZ-B3-B. 100 AMP, 100 V, 35 ns RISE TIME LASER DIODE DRIVER WITH IEEE AND RS-232 CONTROL SERIAL NUMBER:

3M Mini D Ribbon (MDR) Cable Assembly.050 Right-Angle High-Flex Digital Camera Cable 26 position 14H26-SZ3X-XXX-04C

400 MHz Passive High-Voltage Probe R&S RT-ZH

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Flashlink CWDM Add & Drop Module

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

Distance Measuring Sensor Unit Measuring distance : 4 to 30 cm Analog output type

Operator s Manual. PP022 Passive Probe

3M Shrunk Delta Ribbon (SDR) Cable Assembly.80 mm High Speed Digital Data Transmission, 26 position 1MF26-L5XX-00C-XXX

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

NI PXI-2521 Specifications 40-Channel DPST Relay Module

BROADBAND'LINEAR'AMPLIFIER WITH'A±B'INPUTS'AND'DC5OFFSET Model&A400X

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

Agilent 1GG Packaged 13.5 GHz GaAs Diode Limiter

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

Model 9305 Fast Preamplifier Operating and Service Manual

High Efficiency AC Input 12A 12V Laser Driver

TK 100 Probe Calibrator. Instruction Manual

NI PXI-2520 Specifications 80-Channel SPST Relay Module

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

100V GaN E-HEMT Half Bridge Evaluation Kit. Visit for the latest version of this user s guide.

Appendix A: Specifications

High Efficiency AC Input 8A 19V Laser Driver

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

SUBNANOSECOND PULSE GENERATOR PPG-2/1000 USER MANUAL

High Voltage, Input Rectifier Diode, 10 A

TETRIS User's Guide. High Impedance Active Probe DO177-1

NI PXI/PXIe-2529 Specifications

SAS-543 Biconical Antenna Operation Manual

Voltage Transient Emission Test

Part No. Data Rate Media type Distance

GL480E00000F. Infrared Emitting Diode GL480E00000F. Features. Agency Approvals/Compliance. Applications

NI PXI/PXIe-2532 Specifications

Opus 21 s80 Integrated Amplifier Owner's Manual

Model 113 Scintillation Preamplifier Operating and Service Manual

NI PXI-2530 Specifications

NI SCXI Specifications

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

PI-10 Broadband Power Indicator

4. Absolute Maximum Ratings (Note) (Unless otherwise specified, T a = 25 ) Symbol V RRM I F(DC) I FP. I 2 t. T j T stg TOR

Features. Block Diagram

CIRCUIT-TEST ELECTRONICS

DUAL%CHANNEL%LINEAR%AMPLIFIER %WITH%PHASE%INVERTER Model&A400DI

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

INSTRUCTIONS MODEL AV-1010-B. ±100 VOLTS, 2 AMP, 1 MHz GENERAL PURPOSE LAB PULSE GENERATOR AND LASER DIODE DRIVER WITH IEEE AND RS-232 CONTROL

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

3M Mini Serial Attached SCSI (minisas) Cable Assembly

Materials Declaration

Operation and Service Manual. 350 MHz Preamplifier SIM914. Stanford Research Systems

INSTRUCTIONS MODEL AVRZ-5A-B MODEL AVRZ-5W-B. 500 VOLTS INTO 50 Ω, 6 ns RISE TIME PULSE GENERATOR WITH IEEE AND RS-232 CONTROL SERIAL NUMBER:

Broadband Current Probe Series Operation Manual

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

MODULATION LIGHT SOURCE FOR DWDM APPLICATIONS

PML 711A-RO High impedance passive probe Features:

Materials Declaration

Preliminary. LED Driver. Xitanium SR 75W A 54V SR XI075C200V054VPT1

GL4800E0000F. Infrared Emitting Diode GL4800E0000F. Features. Agency Approvals/Compliance. Applications

Technical Documentation

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

PXIe Contents SPECIFICATIONS. RF Preselector Module

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Standard Recovery Diodes (Stud Version), 70 A

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Transcription:

AVTECH ELECTROSYSTEMS N A N O S E C O N D P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 W A V E F O R M E L E C T R O NI C S S I N C E 1 9 7 5 TEL: 888-670-8729 (USA & Canada) or +1-613-686-6675 (Intl) FAX: 800-561-1970 (USA & Canada) or +1-613-686-6679 (Intl) info@avtechpulse.com - LTD. http://www.avtechpulse.com/ INSTRUCTIONS MODEL AVX-TFR-STUD TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER: X BOX 5120, LCD MERIVALE OTTAWA, ONTARIO CANADA K2C 3H4

2 WARRANTY Avtech Electrosystems Ltd. warrants products of its manufacture to be free from defects in material and workmanship under conditions of normal use. If, within one year after delivery to the original owner, and after prepaid return by the original owner, this Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item. This warranty does not apply to units which have been dissembled, modified or subjected to conditions exceeding the applicable specifications or ratings. This warranty is the extent of the obligation assumed by Avtech with respect to this product and no other warranty or guarantee is either expressed or implied. TECHNICAL SUPPORT Phone: 888-670-8729 (USA & Canada) or +1-613-686-6675 (International) Fax: 800-561-1970 (USA & Canada) or +1-613-686-6679 (International) E-mail: info@avtechpulse.com World Wide Web: http://www.avtechpulse.com

3 TABLE OF CONTENTS WARRANTY...2 TECHNICAL SUPPORT...2 TABLE OF CONTENTS...3 INTRODUCTION...4 REGULATORY NOTES...5 FCC PART 18... 5 EC DECLARATION OF CONFORMITY...5 DIRECTIVE 2011/65/EU (RoHS)...6 DIRECTIVE 2002/96/EC (WEEE)...6 BASIC AMPLITUDE CONTROL...8 SETTING THE AMPLITUDE LEVELS...9 AMPLITUDE ACCURACY...10 INCORRECT ORIENTATION...10 CABLE LENGTHS...10 ACCESSIBLE VOLTAGES...10 TEST JIG MECHANICAL ASPECTS...11 SAFETY INTERLOCK...14 WIRING DIAGRAM...15 Manual Reference: /fileserver2/officefiles/instructword/avx-tfr/avx-tfr-stud,ed1.odt. Last modified November 9, 2017. Copyright 2017 Avtech Electrosystems Ltd, All Rights Reserved.

4 INTRODUCTION The AVX-TFR-STUD test jig is designed for use with the AVR-EBF6-B series of forward recovery time test systems, and it is designed to accept DO-4 and DO-5 standard and reverse-polarity stud packages. This test jig can be used as a replacement or an alternative for the test jigs originally supplied with the Avtech AVR-EBF6-B units.

5 REGULATORY NOTES FCC PART 18 This device complies with part 18 of the FCC rules for non-consumer industrial, scientific and medical (ISM) equipment. This instrument is enclosed in a rugged metal chassis and uses a filtered power entry module (where applicable). The main output signal is provided on a shielded connector that is intended to be used with shielded coaxial cabling and a shielded load. Under these conditions, the interference potential of this instrument is low. If interference is observed, check that appropriate well-shielded cabling is used on the output connectors. Contact Avtech (info@avtechpulse.com) for advice if you are unsure of the most appropriate cabling. Also, check that your load is adequately shielded. It may be necessary to enclose the load in a metal enclosure. If any of the connectors on the instrument are unused, they should be covered with shielded metal dust caps to reduce the interference potential. This instrument does not normally require regular maintenance to minimize interference potential. However, if loose hardware or connectors are noted, they should be tightened. Contact Avtech (info@avtechpulse.com) if you require assistance. EC DECLARATION OF CONFORMITY We Avtech Electrosystems Ltd. P.O. Box 5120, LCD Merivale Ottawa, Ontario Canada K2C 3H5 declare that this pulse generator meets the intent of Directive 2004/108/EG for Electromagnetic Compatibility. Compliance pertains to the following specifications as listed in the official Journal of the European Communities: EN 50081-1 Emission EN 50082-1 Immunity

6 and that this pulse generator meets the intent of the Low Voltage Directive 2006/95/EC. Compliance pertains to the following specifications as listed in the official Journal of the European Communities: EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use DIRECTIVE 2011/65/EU (RoHS) We Avtech Electrosystems Ltd. P.O. Box 5120, LCD Merivale Ottawa, Ontario Canada K2C 3H5 declare that, to the best of our knowledge, all electrical and electronic equipment (EEE) sold by the company are in compliance with Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (also known as RoHS Recast ). In addition, this declaration of conformity is issued under the sole responsibility of Avtech Electrosystems Ltd. Specifically, products manufactured do not contain the substances listed in the table below in concentrations greater than the listed maximum value. Material/Substance Threshold level Lead (Pb) < 1000 ppm (0.1% by mass) Mercury (Hg) < 1000 ppm (0.1% by mass) Hexavalent Chromium (Cr6+) < 1000 ppm (0.1% by mass) Polybrominated Biphenyls (PBB) < 1000 ppm (0.1% by mass) Polybrominated Diphenyl ethers (PBDE) < 1000 ppm (0.1% by mass) Cadmium (Cd) < 100 ppm (0.01% by mass) DIRECTIVE 2002/96/EC (WEEE) European customers who have purchased this equipment directly from Avtech will have completed a WEEE Responsibility Agreement form, accepting responsibility for WEEE compliance (as mandated in Directive 2002/96/EC of the European Union and local laws) on behalf of the customer, as provided for under Article 9 of Directive 2002/96/EC. Customers who have purchased Avtech equipment through local representatives should consult with the representative to determine who has responsibility for WEEE

7 compliance. Normally, such responsibilities with lie with the representative, unless other arrangements (under Article 9) have been made. Requirements for WEEE compliance may include registration of products with local governments, reporting of recycling activities to local governments, and financing of recycling activities.

8 BASIC AMPLITUDE CONTROL The AVX-TFR-STUD is intended for use with an Avtech AVR-EBF6-B forward recovery test system, ordered separately. Please refer to the manual supplied with the AVREBF6-B instrument for detailed usage instructions. An example configuration suitable for use with the AVR-EBF6-B is shown in the figure below. VOLTAGE PULSE INPUT (VIN) DIODE VOLTAGE (VDUT) +50V max. VFM 0V 0.7 V typ. 0V tfr 8, 10, or 12 ns (10%-90%) rise time filter* VOUT = VDUT / 10 AVTECH AVR-EBF6-B MAINFRAME OSCILLOSCOPE (BW > 400 MHz) RS1, 50Ω RS2, 50Ω IN Up to +100V + VDUT RB, DUT 450Ω OUT RC, 50Ω - CONTROL SYNC CONNECTOR TEST JIG RM, 450Ω MON RN, 50Ω DB-9 cable* TRIG 60 cm BNC-to-SMA coaxial cable* 30 cm coaxial cable* Coaxial cable (not supplied) 60 cm coaxial cables* * These items are supplied with the AVR-EBF6-B. They are not supplied with separately-ordered AVX-TFR test jigs. The mainframe connects to the rise time filter using a 60 cm length of coaxial cable. The output of the filter connects to the test jig using a 30 cm length of coaxial cable.

9 A DB-9 control cable connects the mainframe to the test jig, to control the safety interlocks. The test jig main output is fed into the 50 Ohm input of an oscilloscope by a 60 cm length of coaxial cable, as is the monitor output. The SYNC output of the mainframe should be used to trigger the oscilloscope. A 50 Ohm resistance (RC in the diagram above) must be connected to ground on the output. This can be a discrete resistor, a feed-through terminator, or the input impedance of an oscilloscope (the latter method is shown in the diagram). If a highspeed sampling oscilloscope is used, the input should be protected by adding attenuator on the input. The 450 Ohm resistance in series with the test jig output and the 50 Ohm input impedance of the oscilloscope form a 10:1 voltage, so the measured voltage is: VOUT = VDUT / 10 The monitor output is similarly divided by a factor of 10, so that: VMON = VIN / 10 The monitor output is provided so that the user may determine the starting point of the transient. SETTING THE AMPLITUDE LEVELS The amplitude pulse may be set from the front panel of the instrument, or by computer command. This amplitude is expressed in terms of the voltage present on the test jig input. The amplitude is related to the forward diode current by: IF (VIN - VDUT) / 50Ω where VDUT is the forward voltage drop of the diode (typically 0.7V for the classic silicon PN junction diode, and usually somewhat lower for a Schottky diode). For instance, if the desired forward current amplitude is 500 ma, the amplitude should be set at 25.7V, so that (25.7V 0.7V) / 50Ω = 500 ma. It may be necessary to adjust the amplitude iteratively to obtain the desired I F, since VDUT may not be known in advance.

10 AMPLITUDE ACCURACY Due to the variations in VF as a function of operating conditions, the amplitude settings should not be relied upon for any degree of accuracy. Instead the voltage at the OUT terminal on the test jig should be monitored with a calibrated oscilloscope. RB can be measured directly on the test jig (with the test jig disconnected) to determine calibrated relationships, if desired. RC is provided by the user, and can be calibrated as required. INCORRECT ORIENTATION The instrument and the DUT will not be damaged if the diode is installed with the incorrect orientation (i.e., with the anode and cathode reversed). However, incorrect waveforms will be generated, CABLE LENGTHS The cable lengths are not critical. They may be increased or decreased as desired. The cables connecting the OUT and MON signals to the oscilloscope should have identical lengths, to avoid introducing timing skews. ACCESSIBLE VOLTAGES The mainframe provides pulsed voltages of up to 100V to the test jig. For this reason, the output is automatically disabled when the test jig lid is open. The lid must be closed to obtain measurements. Shielded cabling should be used for all connections to the "IN" and "OUT" terminals on the test jig, and the "OUT" connector on the mainframe. When used properly (with RC = 50 Ohms), the maximum voltage on the OUT terminal will be < 1V, approximately. However, if R C is not connected and the DUT is not installed, the maximum voltage will at the OUT terminal may be as high as 100V. You may need to consider whether this scenario would damage your oscilloscope, and take appropriate precautions.

11 TEST JIG MECHANICAL ASPECTS The AVX-TRR-STUD accepts DO-4 and DO-5 standard and reverse-polarity stud packages. The test jig is shown below: The photo below shows a reverse-polarity DO-4 diode (the Ruttonsha 12FLR60/F05) installed between the four spring-loaded contacts (two for the anode end, and two for the cathode end):

12 To install the diode, spread apart one pair of spring pins with your fingers or tweezers, and insert one end of the diode. Repeat on the other end. The photo below shows a normal-polarity DO-5 diode (the Ruttonsha 40HF80) installed between the four spring-loaded contacts (two for the anode end, and two for the cathode end):

13 The IN, OUT, MON, and CONTROL connectors are on the rear of the jig, below the hinges:

14 SAFETY INTERLOCK The AVX-TFR-STUD contains safety interlock devices, for use with the AVR-EBF6-B mainframe. The DB-9 female CONTROL connector should be connected to the corresponding connector on the AVR-EBF6-B mainframe using the straight-through DB-9 cable supplied with the AVR-EBF6-B. The DB9 CONTROL connector pinout is as follows: Pin 1 - To test jig switch 1. Pin 2 - To test jig switch 2. Pin 5 - Ground. Pin 6 - To test jig switch 1. Pin 7 - To test jig switch 2. Pin 9 - Safety sensor power supply (+15V through 680 Ohms). When the test jig lid is safely closed, Pin 1 is shorted to Pin 6, and Pin 2 is shorted to Pin 7. Switch 1 is a passive mechanical switch. Switch 2 is an active photosensor, which requires power from Pin 9.

WIRING DIAGRAM