Measurement of Shielding Effectiveness. Nikhil Jain

Similar documents
Regarding RF Isolation for small Enclosures

Test Centre Facilities Regulatory Test Lab

RADIOMETRICS Midwest Corporation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

32 AMP Single Phase Power Filter

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Accredited calibration of field strength meters

REPORT, RS132L24, MIL, EMC, 461F, RE102, IN HOUSE, , PASS. RS132L24 with KIT 00115

pel.com Microwave & RF, March 23 rd, 2016.

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

Valon Synthesizer RFI Test Report

CS114 + CS115 + CS116

EMC Near-field Probes + Wideband Amplifier

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3

Model: M /800 MHz Mobile Radio

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

Downloaded from 1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Test sites for EMC measurements

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Calibration and Validation for Automotive EMC

PCTEST ENGINEERING LABORATORY, INC B Dobbin Road, Columbia, MD USA Tel / Fax

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Page 2 of 20. Table of contents. Page

Model AS18071, M1, M2 AR System 10kHz 18GHz

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

Report Of. Shielding Effectiveness Test For. DefenderShield. Test Date(s): September 1 October 2, 2012

EXPANDED FREQUENCY ELECTROMAGNETIC INTERFERENCE (EMI) SHIELDING EFFECTIVENESS (SE) TESTING

Trees, vegetation, buildings etc.

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

Test and Measurement for EMC

This is a preview - click here to buy the full publication

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

Figure 1: Worst-Case Emissions *FCC Class B compliance not estimated 4 below 200 MHz due to lack of antenna calibration and chamber reflectivity

TDS-535 Tuned Dipole Set Operation Manual

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

EM-ISight Electromagnetic Scanning System. Since Page 1 of 6 Phone (613) Fax (613)

Normalized Site Attenuation Test Report

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

Specific Absorption Rate (SAR) Overview Presented by Mark Jenkins and Vina Kerai. TÜV SÜD Product Service GmbH

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TOKIN EMC ENGINEERING CO., LTD Hanashimashinden, Tsukuba-shi, Ibaraki Japan

Verification of Conformity On Behalf of

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

C E R T I F I C A T E OF C A L I B R A T I O N

Accredited Standards Committee C63 - EMC

SAS-563B Active Loop Antenna Operation Manual

FCC RADIO TEST REPORT

SAS-562B Active Loop Antenna Operation Manual

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

Deon Dai Engineer Reviewer

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Current Probe Fixture Instruction Manual

Test Plan for Hearing Aid Compatibility

EMC TEST REPORT - Addendum

We re In The Business Of Making Your Life Easier

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED EN V9.0.2 ( )

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

Appendix for the Report Dosimetric Assessment of the Portable Device Selex Elsag S.p.A. PUMA T3 plus (FCC ID: X5Y )

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

AS/NZS TEST REPORT. : Wireless IR Repeater System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Characteristics of Biconical Antennas Used for EMC Measurements

Application Note #38B Automotive 600V/m Radar Pulse Test Solution

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

AK-18G Antenna Kit Operation Manual

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

EMC TEST REPORT. according to

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

SAS-551 Passive Monopole Antenna Operation Manual

FCC Radio Test Report

FCC Part Transmitter Certification. Test Report

Radiated Spurious Emission Testing. Jari Vikstedt

EN 50371: 2002 TEST REPORT

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

Transcription:

Measurement of Shielding Effectiveness Nikhil Jain 1

Outline Introduction Scope Equipment Measurement Process Test Report Testing at DoT/TEC Other Activities Conclusion 2

About BNN Communication Engineers Offering Wireless Services since 1995 Network Planning & Optimization, EMF Measurement and Compliance, Interference Analysis, Spectrum scanning, Regulatory Liaison Services Setting up of turnkey SAR Laboratories (TEC, BNNSPEAG, TUV Rhineland, Intel) Shielded Chamber Testing (TEC and BNNSPEAG) Set up EMR Division as an independent Laboratory Offer Shielding Effectiveness Measurement Services 17025 accreditation applied to NABL, EDC Nov 2018 3

BNNEMR - Scope Measuring / testing of Electromagnetic Shielding between frequency range 9 KHz 40 GHz Electromagnetic Shielding Enclosures - IEEE 299: 2006. Enclosures and boxes (0.75m to 2m) - IEEE 299.1: 2013. Ground based C4I facilities for protection against High Altitude Electromagnetic Pulse (HEMP) - MIL Std. 188-125.2: 3 Mar 1999. 4

Equipment Signal Generator, Keysight N5173B 9 khz to 40 GHz Spectrum Analyser, Keysight FireFox N5173B Integrated VNA and SA 9 khz to 44 GHz Amplifiers/Preamplifiers Amp (DC 200MHz MiniCircuits) Pre-Amp (20MHz 2GHz) AH systems, USA 5

Equipment Antennae (AH Systems, USA) 9KHz 16 MHz Loop Antennae 20MHz 100MHz Bi Conical Antennae 100MHz 1GHz Dipole Antenna Horn Antennae (Aaronia, Germany) 4GHz 40GHz 6

Equipment Horn Antennae (Miscellaneous) 1.12GHz 1.7GHz 1.7GHz 2.6GHz 2.6GHz 3.95GHz 3.95GHz-5.85GHz 5.85GHz-8.2GHz 8.2GHz 12.4GHz 12.4GHz-18GHz 18GHz-26.5GHz 26.5GHz-40GHz Accessories Attenuators DC-40GHZ (Pasternack) 40GHz Connecting Cables Adapters 7

Measurement Method/Process Described in IEEE 299:2006 Start User Input - Chamber Data (Dimensions, door-vent-feed thru numbers and locations, drawings, space around) - Test Frequencies, Pass/Fail Criterion Prior moving equipment to site Preparation of Test Plan and Test Log Format - Test Locations as per Standard & Chamber drawings - Equipment List based on test frequencies and Pass/Fail criterion LF (9KHz 16 MHZ) -DR Measurement -14-16 MHz (Linearity) - Measure/Record in Test Log - Loop Antennae RESONANT (20MHz-300MHz) -DR Measurement - Measure/Record in Test Log - 20-100MHz : Bi-conical - 100-300MHz : Dipole HF (300MHz-40GHz) -DR Measurement - Measure/Record in Test Log - 300-1000MHz : Dipole - 1-40GHz : Horn Preparation of Test Report - Collect information from Test Log - Prepare Report 8

Test Report : Contents 9

Testing at DoT/TEC 1 0

Testing at DoT/TEC 1 1

Other Activities : BNNSPEAG Laboratory Electric Field Calibration (ISO 17025) : Electric Field (V/m) Calibration of EMF / EMC Probes & Sensors RF Calibration (17025 accreditation A/F, EDC Nov 2018) Spectrum Analyzers (R&S, Anritsu, Tektronix, Sitemaster) Multi-Band scanners, receivers, test mobile phones Signal Generators, Attenuators RF Conformance Testing RF measurements for GSM, EGPRS, WCDMA, HASPA, LTE(FDD0/TDD) Lab equipped with CMW500 BTS Simulator from R&S EM Field Measurements From electronic/electrical equipment DASY52 NEO Robot scanning system SAR Measurements (ISO 17025 compliant) Head and Body SAR Measurements for Mobile Phones, PDA's, Laptops Equipped with cdasy6 and csar3d Fast SAR system Primarily used for research / testing / development of the SAR measurement systems (cdasy6 / csar3d / DAK-TL etc.) 12

Conclusion Offering wireless services since 1995 Setup several SAR Labs both in India and abroad Set up EMR Division Offers Shielding Effectiveness Measurement Services 17025 accreditation applied to NABL, EDC Nov 2018 Has all necessary equipment to undertake Testing/Measurements upto 40GHz Has an established for testing/measurement and preparation of report in accordance with IEEE 299:2006 Offers several services including calibration of EMC probes, RF instruments etc 1 3