Universal Protection System for Ac Industrial Motors

Similar documents
3 Phase Induction Motor Protection using Numerical Relay

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM

Monitoring the Transformer Oil Temperature and Load Sharing Using Gsm

OverLoad Protection using Microprocessor based OverVoltage Relay:Proteous Simulation

Circuit Breaker Based Feeder Pillar

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Power systems Protection course

Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT

SIMULATION OF TRANSFORMER PROTECTION USING MICROCONTROLLER BASED RELAY & MONITORING USING GSM

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC

Implementation Of Solid State Relays For Power System Protection

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Automatic Load Sharing of Transformers using Microcontroller

LOAD SHARING OF TRANSFORMERS BASED ON MICROCONTROLLER

WIRELESS PROTECTION OF INDUCTION MOTOR BY MICROCONTROLLER AND WI-FI TECHNOLOGY Harsha Jain 1, Surbhi Shrivastava 2

MOTOR PROTECTION RELAY

Simulation & Realization of Feeder Protection with Micro Controller

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

Generator in a power station requires different type of

DETECTION AND DIAGNOSIS OF STATOR INTER TURN SHORT CIRCUIT FAULT OF AN INDUCTION MACHINE

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION

International Journal of Advance Engineering and Research Development. Wireless Control of Dc Motor Using RF Communication

Real Time Monitoring of SF6 Gas Pressure for Optimization Point on Wave Switching of SF6 Circuit Breaker

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

CONTENTS. 1. Introduction Generating Stations 9 40

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

Design and Development of Protective Circuit against Voltage Disturbances

International Journal of Advance Engineering and Research Development PROTECTION OF TRANSFORMERS USING SENSORS

The Fan Company Microcontroller Fan. Prepared by. JMC Engineering

Unsymmetrical Fault Analysis & Protection Of The Existing Power System

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

# - - Internal * On Line Examination

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

PROTECTION of electricity distribution networks

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

Speed Control Of Transformer Cooler Control By Using PWM

A Single Phase Power Factor Correction Using Programmable Interface Circuit

ABB Power Products Service

WIRELESS THREE PHASE LINE FAULT MONITORING

Auto Selection of Any Available Phase in 3 Phase Supply System

VI 3 - i TABLE OF CONTENTS

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.

GUJARAT TECHNOLOGICAL UNIVERSITY, AHMEDABAD, GUJARAT COURSE CURRICULUM COURSE TITLE: SWITCHGEAR & PROTECTION (COURSE CODE: )

Relay Types and Applications Dr. Sasidharan Sreedharan

ADVANCED PROCESS CONTROL AND AUTOMATION USING SCADA

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3

International Journal of Advance Engineering and Research Development

Fault Detection in Three Phase Induction Motor

Application of Low-Impedance 7SS601 Busbar Differential Protection

A Review on Load Sharing of Transformer

Overcurrent and Overload Protection of AC Machines and Power Transformers

Digital Monitoring Cum Control of a Power Transformer with Efficiency Measuring Meter

Transformer Protection

Design and Construction of Synchronizing Check Relay

ARDUINO BASED POWER FACTOR CORRECTION

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Application of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

Embedded based Automation System for Industrial Process Parameters

Harmonic Distortion Impact On Electro-Mechanical And Digital Protection Relays

ISSN: (Online) Volume 2, Issue 1, January 2014 International Journal of Advance Research in Computer Science and Management Studies

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani

Accident prevention and detection using internet of Things (IOT)

Introduction To Temperature Controllers

New Invention in Converting Two Phase to Three Phase Employing an Induction Machine

Transformer Health Condition Monitoring Through GSM Technology

Power Line Communication Based Fault Monitoring And Control

GSM BASED TRANSFORMER HEALTH MONITORING SYSTEM

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

Cortex-M3 based Prepaid System with Electricity Theft Control

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

ENOSERV 2014 Relay & Protection Training Conference Course Descriptions

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

In the event of a failure, the inverter switches off and a fault code appears on the display.

ISSN Vol.05,Issue.01, January-2017, Pages:

Loss of Excitation protection of generator in R-X Scheme

Power Factor Correction in Digital World. Abstract. 1 Introduction. 3 Advantages of Digital PFC over traditional Analog PFC.

International Journal of Advance Engineering and Research Development

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

Electrical Motor Power Measurement & Analysis

Minimizing Plant Interruption Caused by Line Disturbances Using Active Voltage Conditioners

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

An Improved Method for Protection of Three Phase Induction Motor using Microcontroller

Electrical Protection System Design and Operation

IN MANY industrial applications, ac machines are preferable

Comparison of PWM Techniques and Inverter Performance

Application of Wavelet Transform in Power System Analysis and Protection

COURSE PLANNER. Subject: TESTING AND COMMISSIONING OF ELECTRICAL EQUIPMENTS ( ) B.E. Fourth Year (8 th Sem) Branch Electrical Engineering

A Case Study of Resonance in 11kV Network in the Presence of Series Current Limiting Reactors, VSDs and Power Factor Improvement Capacitors

Voltage Variation Compensation

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

Job Sheet 2 Servo Control

Motor Protective Relay

SECTION AUTOMATIC TRANSFER SWITCH

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM

AN ANN BASED FAULT DETECTION ON ALTERNATOR

A New Approach to Combined under Voltage and Directional Over Current Protection Scheme

Design and Implementation of AT Mega 328 microcontroller based firing control for a tri-phase thyristor control rectifier

Dynamic Model Of 400 Kv Line With Distance Relay. Director Research, The MRPC Company, Hyderabad, India 2

Automatic Locking Door Using Face Recognition

Transcription:

Universal Protection System for Ac Industrial Motors Mr. Ibrahim Rawat 1, Mr. Saurabh Patel 2, Mr. Akshil Chauhan 3, Mr. Nisargkumar Parmar 4, Mr. Sunil Malival 5 1234 B.E Students, ITM Universe, Vadodara 5 Asst. Professor, ITM Universe, Vadodara Institute of Technology & Management Universe, Vadodara, India Abstract: The purpose of designing this project is to protect alternating current motors from various faults such as over-voltage, over-current, under voltage, unbalanced current & over heating etc. Protection system for motors plays a vital role in industries such that production is not slow down owing to failure of any motor. The main idea for the development of this project is to offer safety to the AC industrial motors, pumps and very high speed motors. If any of the given phase gets damaged (due to fault) or if any over current or over voltage fault occurs motor stops immediately. If any of the phases is not available the respective transformer will stop supplying power to the circuit. Further the project can be expanded by using current sensors for over load protection and phase sequence sensor for protecting the motor from wrong phase sequence. We are using microcontroller which will compare the current data with the predefined data and if found faulty then it will command relay to trip and will protect the ac motors. Keywords: AC Motors, Protection, Microcontroller, Relay, Contactors I. Introduction Nowadays, due to the Modern power systems, the system requires high degree of reliability. A system during its operation may develop some trouble or may produce some abnormal condition of operation, which may cause damage to the equipment s. Among them some of the situations are unavoidable and beyond human control. Therefore, to detect such fault conditions and react quickly in order to minimize adverse impact, a realtime algorithm is required [1]. This monitoring function is efficiently managed by a smart electronic device, known as the protection relay, which continuously observes the grid parameters (such as voltages & currents) and switches the appropriate devices in faulty conditions. Most of the data processing happens in the digital system. So, these devices are called as Numerical or Digital Protection Relays. Electric motors are very important for any industrial plant, and often run critical processes. The motors which have ratings below 3.3kV are known as Low Tension (LT) Motors and those whose are ranging from 3.3kV to 11kV are called as High Tension (HT) Motors. Motors which are used in manufacturing sector like oil, gas and mining industries consumes electricity of around 90%. Thus, motors are a remarkable investment. But if we analyse the statistics, we can say that despite of having reliability of operation and simplicity of construction, annually the motor failure rate is around 3.5-5%. Downtime in a factory can be expensive and, can also exceed the cost of motor replacement. Hence, a proper motor protection is required to minimize the motor failure rate, prevent damage to equipment associated and to ensure production targets along with personnel safety [2].In industries many faults in motors occurs such as, Over Current Unbalanced current Over voltage Under voltage Symmetrical faults Single phasing Over load Temperature rise etc. So to avoid effects of such problems we will make universal protection system for ac motors which will protect our motor from above problems. And it will be user defined as per the ratings of motors (up to 25 amps). The basic idea for the development of this project is to provide safety to the industrial motor, pumps and very high speed motors i.e. spindle motor, Induction motors etc. In this system three single phase transformer are connected to three phase power supply. 45 Page

II. Literature Survey Over a hundred years ago, since the beginning of system protection, the protective relaying in industrial and utility power systems has tremendously evolved. Electromechanical relays were the defective protection devices without the use of microcontrollers. These were more preferable for simple protective functions of individual loads, but not preferable for complex system [c][d]. Around 1970s, solid-state static relays replaced the EM relays with a slight change in protection scheme. The design consisted of analog circuits for detection of current/voltage value, instead of coils and magnets. After the detection of input signal, a comparator circuit determined the overload condition. But, for designing the statics relay there were certain problem which were arising adding to its limitations [c][d]. The first generation microprocessor based numerical relays then brought innovations in developing new algorithms and the beginning of combining several protection functions in one multifunction relay package. Major difference in analog circuits here was the use of analog to digital converter [3][4]. These relays have built-in test routines, it is also called as a watchdog, that signals an alarm output, & the operators know when the relay fails. A report on Large Motor Reliability Survey of Industrial and Commercial Installations, published by the IEEE Motor Reliability Working Group gives results of IEEE surveys on motor reliability and major causes of motor failure[5]. A summary of these results is shown in Table 1:- Table 1 Failure Contributor Percentage Overload 30% Insulation damage 20% Phase failure 14% Bearing damage 13% Ageing 10% Rotor damage 5% Others 8% The various limitations found in presently available relays are [6]: Error in Phase angle while detection. Analog input range is not accurate. Noise problems while operating. Capability of communication is very less. Low precision in calculation of analog inputs. Response time is slow. Data storage is constant. Less facility of disturbance record. III. Block Diagram Fig 1 shows the block diagram of the protection system. Here the three single phase transformer are connected to three phase supply. Three CT,s and three PT,s are connected to three phase supply. AC supply is converted to DC supply using converter circuit and it is fed to ADC. Further, the digital pulses are given to microcontroller from ADC. 5v external supply is to be given to operate microcontroller where display is given so that we can continuously check parameters such as voltage, current, temp, etc. Microcontroller will not directly drive the relay when fault occurs, so we require relay driver circuit. We are using ULN 2003 relay driver IC which can drive total 8 relay from the range of 5v to 12v. We are also using the contractor for tripping the circuit. Basically contactor is an electrically controlled switch used for switching an electrical power circuit 46 Page

IV. Flow Chart In the starting our system will show our system s name MOTOR PROTECTION UNIT then it will start showing normal operating data of voltages, currents and temperature of every single phase. Now it will compare this data of every phase step by step with pre-set values. And this information will be sent to microcontroller. Now when error or fault is found or detected at that time fault will be displayed on LCD and again loop will be restarted. We can set our data as per the rating of the motor at every restart. 47 Page

V. Simulation Results VI. Hardware Circuit 48 Page

VII. Results & Discussions We have manually made faults on every phase and made the system to trip the circuit. When R phase s voltage become more than rated value, our system identified the fault and tripped the circuit. And at that time LCD was showing R PHASE OVER VOLTAGE. We have manually made faults on every phase and made the system to trip the circuit. When Y phase s voltage become more than rated value, our system identified the fault and tripped the circuit. And at that time LCD was showing Y PHASE OVER VOLTAGE. We have manually made faults on every phase and made the system to trip the circuit. When R phase s voltage become more than rated value, our system identified the fault and tripped the circuit. And at that time LCD was showing B PHASE OVER VOLTAGE. We have manually made faults on every phase and made the system to trip the circuit. When phase s current become more than rated value, our system identified the fault and tripped the circuit. And at that time LCD was showing OVER CURRENT. We have set the temperature limit to 40 0 C and we have continuously ran the motor at full load until temperature increased beyond 40 0 C and when system s temperature is above critical limit circuit will trip and system will show OVER TEMP on LCD screen. 49 Page

VIII. Acknowledgement A research work of this magnitude has been a journey with various ups and downs. We would like to extend our sincere & heartfelt obligation towards all the personages who have helped us in this endeavour. Without their active guidance, help, co-operation & encouragement, we would not have made headway in the research paper preparation. With a deep sense of reverence, we acknowledge our gratitude towards the sponsors for our research work, Shreeji Pesticides a unit of willowood Private Ltd. Also, we are ineffably indebted to Sunil Malival, Assistant Professor, ITM Universe, for his conscientious guidance and encouragement to accomplish this work. Last but not the least; we would like to thank Department of Electrical Engineering of our institute and all our colleagues who have been our moral support in the completion of our work. IX. Conclusion Providing protection using digital relay techniques is a critical aspect is field of power system. These relays should employ high-speed and high-accuracy electronics in order to avoid catastrophic failures. Motor protection system requires different techniques and input or output capabilities. Based on this systematic study we have design this protection system that can protect motor from as many faults as it can cover. Our system is capable of applying logic and comparing and then analyzing whether the relay will trip or not based on values of current, voltage & temperature. References [1]. Pero Ostojic, Arijit Banerjee, Dhaval C. Patel, Wrichik Basu, Shahid Ali, Advanced Motor Monitoring and Diagnostics, IEEE Transactions On Industry Applications, Vol. 50, No. 5, September/October 2014 [2]. B.Venkataraman, B.Godsey, W. Premerlani, E.Shulman, M.Thakur, R.Midence, Fundamentals of a Motor Thermal Model and its Applications in Motor Protection, IEEE Magazine on Motor Thermal Model Protection Applications [3]. B. Ram, D. Vishwakarma, Power System Protection & Switchgear, TMH Publication, 2014 [4]. S.S. Rao, Switchgear Protection & Power System, Khanna Publishers, 2013 [5]. Motor Reliability Working Group, Report Of Large Motor Reliability Survey Of Industrial And Commercial Installations, Part I. IEEE Trans. Ind. Appl., vol. IA-21, July/Aug. 1995. [6]. VAMP 50/51, & Rho 3 Over current, Earth fault, and Motor Protection Relay Technical Manual 50 Page