Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Similar documents
Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Submersible pressure sensor For oils and fuels Model LF-1

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

High-quality pressure transmitter For general industrial applications Model S-10

Pressure transmitter For sanitary applications Model SA-11

Submersible pressure sensor For water and wastewater Model LW-1

Flush pressure transmitter For viscous and solids-containing media Model S-11

Pressure transmitter for general industrial applications Model A-10

Submersible pressure sensor For superior applications Model LF-1

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter For mobile working machines Model MH-3

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Field indicator for current loops with HART communication Models DIH50, DIH52

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

High-quality pressure transmitter For general industrial applications Model S-20

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

ED701 General Industry Pressure Transmitter

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Pressure transmitter For general industrial applications Model A-10

HART field temperature transmitter Models TIF50, TIF52, TIF62

In-Line Resistance Thermometers Model TR25

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Field indicator for current loops with HART communication Models DIH50, DIH52

Resistance thermometer Model TR30, compact design

Materials (other materials see WIKA diaphragm seal program) Model S-10

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Electronic temperature switch with display Model TSD-30

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital inductive conductivity transmitter

OEM radar transmitter, for aggressive media level measurement

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

In-line resistance thermometer Model TR25

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

OPTIFLUX 5000 Technical Datasheet

Miniature resistance thermometer Model TR33, thread-mounted

Pressure Transmitter SIL

OPTIFLUX 5000 Technical Datasheet

PAD - Heavy Duty Differential Pressure Trasmitter

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Pressure and level transmitter PASCAL CV LEVEL,

Field IT 2600T Series Pressure Transmitters

TRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters

SITRANS P. Transmitters for level. Introduction 1/42. Application

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

KFS. Flap-type flow meter. Design and range of application

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR31, miniature design

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

SATRON VB Pressure Transmitter

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Process display RIA 261

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Coriolis Massflowmeter

Design and applications

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

The transducer component converts the measured signal and displays the actual value.

SITRANS T measuring instruments for temperature

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Field IT 2600T Series Pressure Transmitters

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Flow Measurement SITRANS F M

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Resistance thermometer Model TR30, compact design

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

OPTIWAVE 1010 Technical Datasheet

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

prosonic T FMU230, FMU231

Resistance Thermometers Model Series TR7X0, Sheathed Design

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

SALES SERVICE +358 (0)

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Digital flow transmitter for continuous flow measurement

Ultrasonic level transmitter, non-contact

Product information. Guided Wave Radar. Level and interface measurement in liquids VEGAFLEX 81 VEGAFLEX 83 VEGAFLEX 86. Document ID: 46597

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Coriolis Massflowmeter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Positioner with HART Communication Type 3780

Transcription:

Electronic pressure measurement Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm WIKA data sheet PE 86.11 Applications Process engineering Pharmaceutical industry Food and beverage industry Special features Ex protection per ATEX and FM For applications to SIL-2 (SIL-3) Metallic and ceramic measuring cells available Seven different case variants Configuration via DTM (Device Type Manager) according to FDT concept (Field Device Tool), e.g. PACTware Fig. left: Model IPT-10, standard version Fig. right: Model IPT-11, flush diaphragm Description With its 4... 20 ma, HART, PROFIBUS PA or FOUNDATION Fieldbus output signals, combined with either intrinsic safety or flameproof enclosure (in accordance with ATEX and FM), the model IPT-1x is ideally suited to applications requiring these features. The electronics of all of these transmitters, even for the flameproof variant, are intrinsically safe. Thus it is possible to make adjustments on the instrument in EX areas while the instrument is live. Versatile in application As a result of the available measuring ranges of 0... 0.1 bar to 0... 4,000 bar and a freely selectable turndown, the instrument can be used in almost any application. The large number of process connections and the possibility of choosing between metallic and ceramic measuring cells enables the use of this transmitter in all industries. There are seven different case variants available, and thus, it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330, and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument is carried out using the optional display and operation module, which can be fitted in four positions. The operation menu has a simple and self-explanatory structure and has nine selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into a corresponding Distributed Control Systems. Page 1 of 13 Data sheets showing similar products: UniTrans, universal transmitter for various applications; models UT-10 and UT-11; see data sheet PE 86.01 Differential pressure transmitter; model DPT-10; see data sheet PE 86.21

Measuring ranges Relative pressure (bar) Measuring range 0... 0.4 0... 1.6 0... 6 0... 16 0... 0.1 0... 0.4 0... 1 0... 2.5 Overpressure limit 2 10 35 80 15 30 35 50 Burst pressure 2.4 12 42 96 15 30 35 50 Measuring range 0... 40 0... 100 0... 250 0... 600 0... 5 0... 10 0... 25 0... 60 Overpressure limit 80 200 500 1,200 65 90 130 200 Burst pressure 400 800 1,200 2,400 1) 65 90 130 200 Measuring range 0... 1,000 0... 1,600 0... 2,500 0... 4,000 Overpressure limit 1,500 2,000 3,000 4,400 Burst pressure 3,000 4,000 5,000 7,000 1) For model IPT-11: The value specified in the table applies only when sealing is made using a sealing ring below the hexagon. Otherwise max. 1,600 bar applies. Other measuring ranges can be set via turndown. For measuring ranges above 600 bar only the model IPT-10 is available. Measuring ranges in absolute pressure are available in the same increments as in relative pressure. s only up to 0 16 bar absolute and ceramic measuring cells up to 0... 60 bar absolute. Vacuum and +/- measuring range (bar) Measuring range -1... 0-1... +0.6-1... +3-1... +5-1... +1.5-1... +10-1... +25-1... +60 Overpressure limit 5 10 17 35 50 90 130 200 Burst pressure 6 12 20 41 50 90 130 200 Measuring range -1... +15-0.2... +0.2-0.1... +0.3-0.1... +0.1-0.05... +0.05 Overpressure limit 80 2 2 15 15 Burst pressure 96 3 3 15 15 Vacuum safety Yes 1) from measuring range 1 bar 1) Not for oxygen applications Accuracy Accuracy at room temperature 1) Measuring ranges < 1,600 bar: 0.1 % of span Measuring ranges 1,600 bar: 0.6 % of span 0.075 % of span Measuring range 0.1 bar abs.: 0.25 % of span Adjustability of zero point -5... +95 % -20... +95 % Non-linearity 0.05 % of span BFSL (IEC 61298-2) 0.05 % of span BFSL (IEC 61298-2) Non-repeatability 0.1 % of span 0.1 % of span Behaviour with turndown 2) 1:1... 5:1 with measuring range No change in accuracy No change in accuracy 0.4... 1,000 bar (metal) 0.1... 60 bar (ceramic) > 5:1 with measuring range < 0.02 % x turndown < 0.015 % x turndown 0.4... 1,000 bar (metal) 0.1... 60 bar (ceramic) 1:1... 2:1 with measuring range < 0.6 % - 1,600 bar 1:1... 5:1 with measuring range - < 0.25 % 0.1 bar absolute > 5:1 with measuring range - 0.05 % x turndown 0.1 bar absolute Long-term stability 3) (0.1 % x turndown) / year (0.1 % x turndown) / year Rated temperature range without display -40... 176 F (-40... +80 C) 32... 212 F (0... 100 C) with display 5... 158 F (-15... +70 C) 32... 158 F (0... 70 C) 1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). Calibrated in vertical mounting position with process connection facing downwards. 2) Measuring ranges 1,000 bar maximum recommended turndown 20:1 Measuring ranges > 1,000 bar maximum recommended turndown 2:1 3) At reference conditions Page 2 of 13

Thermal change zero point and span (reference temperature 68 F (20 C)) in compensated range 32... 212 F (0... 100 C) < 0.05 % / 10 K x turndown < 0.05 % + 0.1 % x turndown < 0.1 % + 0.1 % x turndown with 0.1 bar absolute outside compensated range typical < 0.05 % / 10 K x turndown < 0.05 % + 0.15 % x turndown typical 0.15 % + 0.15 % x turndown with 0.1 bar absolute Thermal change of the current output (reference temperature 68 F (20 C)) for 4... 20 ma output at -40... 176 F (-40... +80 C) < 0.05 % / 10 K, max. 0.15% < 0.05 % / 10 K, max. 0.15% Materials Wetted parts Stainless steel 316Ti 2) Hastelloy C4/C276 Elgiloy 2.4711 O-ring (only for model IPT-11) NBR FPM FKM / EPDM Stainless steel 316L 1) Hastelloy C4/C276 Titanium grade 2 PVDF Oxide ceramic Al 2 O 3 Glass solder EPDM FFKM / FKM FFKM FKM 1) Stainless steel 316L corresponds to 1.4404 or 1.4435 2) Stainless steel 316Ti corresponds to 1.4571 Case Single chamber case, plastic Single chamber case, aluminium Single chamber case, cast stainless steel Single chamber case, electropolished stainless steel, deep-drawn Double chamber case, plastic Double chamber case, aluminium Double chamber case, cast stainless steel Material PBT, polyester Aluminium Stainless steel 316L Stainless steel 316L PBT, polyester Aluminium Stainless steel 316L Page 3 of 13

Operating conditions Temperatures Permissible temperature ranges Ambient with display -20... +70 C without display -40... +80 C Medium 1) Oxygen applications -20... +60 C Aseptic connections -20... +150 C Storage -40... +80 C 1) Oxygen application only possible with metallic measuring cell. Vibration resistance 4 g (5... 100 Hz) per GL characteristic curve 2 Does not apply to double chamber case from stainless steel. Shock resistance 100 g (6 ms) per IEC 60068-2-27 Instrument safety Ingress protection: IP 66/67 Electrical safety: Overvoltage category III Protection class II Explosion protection see "Approvals, directives and certificates" The operating conditions and safety-relevant data in the approval documents must observed. Process limits dependent upon the sealing material without sealing -40... 221 F (-40... +105 C) - FKM -4...221 F (-20... +105 C) (option: -20... +150 C) -40... 302 F (-40... +150 C) EPDM -40... 221 F (-40... +105 C) (option: -40... +150 C) -40... 302 F (-40... +150 C) NBR -4... 221 F (-20... +105 C) - FFKM - -22... 302 F (-30... +150 C) FFKM / FKM - -4... 302 F (-20... +150 C) Display LC display with backlighting. Background grey with black digits. Generally each instrument can be ordered with or without digital indicator. The mounting position of the display depends on the case. Single chamber case: Top Double chamber case: Top or lateral For double chamber cases with Ex d approval only a top mounting position is possible. The different cases can be found under "Dimensions in mm". Page 4 of 13

Output signal Signal type 4... 20 ma 4... 20 ma (2-wire with a superimposed communication signal HART ) FOUNDATION Fieldbus PROFIBUS PA Load in Ω (U B - U Bmin) / 0.023 A U B = applied power supply (s. table "Power supply") U Bmin = Minimum power supply (s. table "Power supply") Damping 0... 999 s, adjustable After the set damping time the instrument outputs 63 % of the applied pressure as output signal. Example: A pressure impulse increases from 0 to 10 bar with a damping of 2 seconds. After the 2 seconds a pressure of 6.3 bar is displayed. Settling time 250 ms Voltage supply Power supply Signal type without Ex Ex ia Ex d 4... 20 ma DC 12... 36 V DC 14... 30 V DC 20... 36 V 4... 20 ma (2-wire with a superimposed communication signal HART ) DC 14... 36 V DC 14... 30 V DC 20... 36 V FOUNDATION Fieldbus DC 9... 32 V DC 9... 24 V DC 12... 32 V PROFIBUS PA DC 9... 32 V DC 9... 24 V DC 12... 32 V While the backlighting of the display is active, the following voltage ranges apply: Signal type without Ex Ex ia Ex d 4... 20 ma DC 22.5... 36 V DC 22.5... 30 V DC 22.5... 36 V 4... 20 ma (2-wire with a superimposed communication signal HART ) DC 22.5... 36 V DC 22.5... 30 V DC 22.5... 36 V FOUNDATION Fieldbus DC 12... 32 V DC 12... 24 V DC 12... 32 V PROFIBUS PA DC 12... 32 V DC 12... 24 V DC 12... 32 V Reference conditions (per IEC 61298-1) Temperature: 18... 30 C (64... 86 F) Atmospheric pressure: 860... 1,060 mbar (86... 106 kpa, 12.5... 15.4 psig) Humidity: 45... 75 % relative Characteristic curve determination: Terminal method per IEC 61298-2 Curve characteristics: linear Reference mounting position: vertical, diaphragm points downward Page 5 of 13

Process connections Model IPT-10 Standard process connections for model IPT-10 Sizes EN 837 ANSI / ASME B1.20.1 G 1/2 B 1/2 NPT 1/2 NPT female Standard high-pressure connections for model IPT-10 from 1,600 bar Sizes - M16 x 1.5 female 9/16-18 UNF female Model IPT-11 Standard process connections for model IPT-11 Sizes Flush G 1/2 B G 1 B G 1 1/2 B G 1 hygienic Diaphragm seals The model IPT-10 process transmitter can be adapted to the harshest conditions in the process industry by using diaphragm or diaphragm in-line seals. Thus, the transmitter can be used at extreme temperatures, and with aggressive, corrosive, heterogeneous, abrasive, highly viscous or toxic media. As a result of the wide variety of aseptic connections (such as clamp, threaded pipe or DIN 11864 aseptic connections) measuring assemblies meet the high demands of sterile process engineering. Special connections Sizes Tri-clamp 1 1/2" 2" 2 1/2" 1) VARIVENT Form F Form N Grooved union nut DIN 11851 NEUMO BioContol 2) Clamp connection DIN 11864-3 DN 25 DN 40 DN 50 Size 50 Size 65 DN 40 DN 50 1) only available for ceramic measuring cell 2) BioControl is a registered trademark of Neumo. Pressure transmission medium Model IPT-10 Measuring range < 16 bar Measuring range > 16 bar Synthetic oil, halocarbon oil Dry measuring cell Dry measuring cell Dry measuring cell Model IPT-11 Synthetic oil, halocarbon oil Dry measuring cell Halocarbon oil generally with oxygen applications, not with vacuum and absolute pressure < 1 bar abs. Optionally FDA-listed media for the food industry are available. Page 6 of 13

Approvals, directives and certificates Approvals Directive ATEX Category II 1G, 1/2 G, 2G Ex ia IIC T6 Category II 1/2 G, 2 G Ex d ia IIC T6 Category II 1/2 D, 2 D IP 66/67 T* FM Intrinsically safe div. 1 class I, II, III groups A, B, C, D, E, F and G and class I, zone 0, group IIC Explosion proof - intrinsically safe div. 1 class I groups A, B, C, D und class I, zone 1, group IIC SIL-2 up to 1,000 bar, only for 4... 20 ma HART with one-channel architecture (1oo1D) per IEC 61508 / IEC 61511 SIL-3 up to 1,000 bar, only for 4... 20 ma HART with two-channel, diversely redundant architecture (1oo2D) per IEC 61508 / IEC 61511 The operating conditions and safety-relevant data in the approval documents must be observed. CE conformity EMC 2004/108/EC interference emission and interference immunity per EN 61326-1 (industrial application), interference emission limit class B ATEX directive 94/9/EG Pressure equipment directive 97/23/EG Electrical connections Connection Spring-loaded terminals for lines up to 2.5 mm 2 (AWG 14) Electrical safety Reverse polarity protection is ensured Connection diagrams Not Ex area Ex area + - Display I 2 C Voltage supply 1 2 5 6 7 8 Load Not Ex area Ex area + - Display I 2 C PLC 1 2 5 6 7 8 Segment coupler Power hub Page 7 of 13

Dimensions in mm Standard process connections for model IPT-10 G 1/2 B EN 837 max. 1,600 bar 1/2 NPT ANSI/ASME B1.20.1 max. 1,000 bar 1/2 NPT female ANSI/ASME B1.20.1 max. 1,000 bar Standard process connections for model IPT-11 G 1/2 B, flush with O-ring G 1 B, flush with O-ring G 1 1/2 B, flush without O-ring G 1 hygienic, flush up to 150 C Sealing ring 18.5 x 23.9 x 1.5 O-Ring 15 x 2 Sealing ring 18.5 x 23.9 x 1.5 O-Ring 15 x 2 O-ring 21.82 x 3.53 Standard high-pressure connections for model IPT-10 9/16-18 UNF female F 250-C from 1,600 bar M16 x 1.5 female with sealing cone ab 1,600 bar Page 8 of 13

Special connections for model IPT-11 DRD Clamp Dimensions in mm ØD Ød Tri-clamp 1 1/2" 50 43.5 2" 64 56.6 2 1/2" 77.5 70.5 VARIVENT VARIVENT Form F 50 Form N 68 Dimensions in mm ØD Grooved union nut DIN 11851 with conical coupling, for pipes per DIN 11850 Dimensions in mm G Ød 3 DIN 11851 DN 25 Rd 52 x 1/6 44 DN 40 Rd 65 x 1/6 48 DN 50 Rd 78 x 1/6 61 NEUMO BioControl Dimensions in mm Ød Ød 2 ØD Øk h H BioControl Size 50 50 4x9 90 70 17 27 Size 65 68 4x11 120 95 17 27 Clamp connection DIN 11864-3 Clamp connection with notch for pipe dimensions per DIN 11850 and 11866 row A Dimensions in mm Ød 10 Ød 11 DIN 11864-3 DN 40 64 53.7 DN 50 77.5 65.7 Page 9 of 13

Schematic diagram of sealing concept, ceramic measuring cell Double sealing for increased safety Application: All process connections except for G 1 flush Absolutely flush form seal Application: VARIVENT Measuring cell Sealing Case variants Single chamber case, plastic Single chamber case, aluminium Single chamber case, cast stainless steel Single chamber case, electropolished stainless steel, deep-drawn Double chamber case, plastic Double chamber case, aluminium Double chamber case, cast stainless steel Page 10 of 13

Display and operating module Display and menu item number LC display Operating keys Menu languages: German English French Spanish Polish Italian Dutch Japanese Chinese 5-digit measured value display, optionally with bar graph display User interface DTM For HART output signals, Profibus PA and FF, a DTM is available in accordance with the FDT standard. The DTM provides a self-explanatory and clear user interface for all setup and control processes of the transmitter. For testing purposes, it is also possible to simulate process values and archive the parameter data. Recording of the measured values is available for diagnostic purposes. Tank volume calculation The additional tank volume calculation of the DTM function can be used to reproduce any optional tank geometry. The corresponding linearisation table is generated automatically. The linearisation table can be transferred directly to the transmitter. Page 11 of 13

Accessories Model Description Order no. DIH52-F Display module DIH52-F 5-digit display, 20-segment bargraph, without separate power supply, with additional HART functionality. Automatic adjustment of measuring range and span. Secondary-master functionality: Setting the measuring range and unit of the connected transmitter using HART standard commands possible. Optionally explosion protection per ATEX on request Model 010031 HART modem for USB-interface 11025166 Model 010001 HART modem for RS-232 interface 7957522 Model 010041 HART modem for Bluetooth interface [EEx ia] IIC 11364254 FC475HR1EKL9 HART protocol, Li-Ion battery, voltage supply AC 100... 240 V coloured display with backlighting, Bluetooth and infrared interface ATEX, FM, CSA and IECEx(i) (including FISCO, if available) FC475HR1EKLU HART protocol, NIMH battery, voltage supply AC 90... 240 V with EASY UPGRADE, ATEX II 2G (1GD) EEx ia IIC T4 on request on request MFC5150 HART protocol, universal voltage supply, cable set with 250 Ω resistance, with explosion protection on request Welding socket for process connection G ½ flush 1192299 Welding socket for process connection G 1 flush 1192264 Welding socket for process connection G 1 ½ flush 2158982 Welding socket for process connection G 1 hygienic flush 2166011 Welding socket for process connection G 1 flush-ceramic 13305441 Welding socket for process connection G 1 ½ flush-ceramic 13318366 Mounting bracket for wall or pipe mounting, stainless steel 11495210 Overvoltage limit for transmitters, 4... 20 ma, 1/2 NPT, series connection 14013656 Overvoltage limit for transmitters, 4... 20 ma, M12 x 1.5, series connection 14002489 Overvoltage limit for transmitters, FF / Profibus, 1/2 NPT, series connection 14013658 Overvoltage limit for transmitters 4... 20 ma, M20 x 1.5, Ex d with flameproof enclosure 12140503 Display and operation module, case cover aluminium with window 12298884 Display and operation module, case cover cast stainless steel with window 12298906 Display and operation module, case cover plastic with window 13315277 Display and operation module, case cover electropolished stainless steel 13315269 with window External display and operation module, aluminium case, ATEX Ex ia 12298825 External display and operation module, cast stainless steel case, ATEX Ex ia 12298850 External display and operation module, aluminium case 12354954 External display and operation module, cast stainless steel case 12355101 External display and operation module, electropolished stainless steel case 14031516 Page 12 of 13

Ordering information Model / Measuring range / Output signal / Accuracy / Process connection / Sealing / Electrical connection / Digital indicator / Case version / Approval 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 13 of 13 04/2015 EN WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043-5868 Tel: 888-WIKA-USA 770-513-8200 Fax: 770-338-5118 E-Mail: info@wika.com www.wika.com