conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

Similar documents
11-SDMS-03 REV. 02 SPECIFICATIONS FOR

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

REPORT OF PERFORMANCE TIC

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Technical Specification. for 1.1 KV Copper Control Cable

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE

Medium Voltage Power Cables

Date: / TECHNICAL SPECIFICATIONS FOR 11 KV XLPE INSULATED UNDERGROUND CABLES

SANS 1339:2010 Electric cables Cross-linked polyethylene (XLPE) insulated cables for rated voltages 3,8/6,6 kv to 19/33 kv

001: 2007 CEB STANDARD

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

SPECIFICATION FOR RUBBER INSULATING GLOVES FOR LOW VOLTAGE 500V

EDS KV SINGLE CORE XLPE CABLES

This Certificate consists of 75 pages in total.

MV water-proof and water tree retardant power cable

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

EDS KV TRIPLEX CABLE RATING

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

Specification for pvc-insulated cables for electricity supply

EDS LV WAVEFORM MAINS CABLE RATINGS

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Tratos High Voltage cables

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Plant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

Kerman & Kavian Cable Industries ( KCI )

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

TECHNICAL SPECIFICATION

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

CERTIFICATE OF CONFORMANCE

BBD7267 Version 1 PRIEVIEW COPY ONLY

P Low Voltage Catalogue Cables Australia Powering your Project

Cable Type 100. CAI Certification Specification

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

TPS 49 EDITION 2 JUNE 2009

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

SECTION MEDIUM-VOLTAGE CABLES

Cable Type 125. CAI Certification Specification

Testing Manual for Electrical Equipment

INTERNATIONAL OIML R 103 RECOMMENDATION

DNVGL-CP-0400 Edition December 2015

Notes 3 Explanatory Information 4-10

Reactor and inductor are names used interchangeably for this circuit device.

Tests on Extruded Cables

ELECTRICAL R&D LABORATORY SPECIFICATION FOR TESTS OF COMPRESSION AND MECHANICAL CONNECTORS AND TERMINAL LUGS FOR POWER CABLES WITH COPPER

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

NPS/002/003 Technical Specification for Protection Tile, Protection Tape, Cable Ducting and Route Markers

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

GLOBAL STANDARD Page 1 of 66 UNDERGROUND MEDIUM VOLTAGE CABLES UNDERGROUND MEDIUM VOLTAGE CABLES

CUSTOM DESIGN COAXIAL CABLES BY SICAB

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Fault location on power cables. Fault location on power cables

Signal converter for electromagnetic flowmeters

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

50-SDMS-01 SPECIFICATIONS FOR

ECP HV INSULATION TESTING

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

Electric cables. Cranes

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

CAT 5e UTP Cable: NETSET BOX [305m], indoor

United Nations Development Programme

a Nexans company Catalogue 2009

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

IEC Standard Caledonian Offshore & Marine Cables

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

COPPER + LWL RAW CABLES

SECTION - II BID DATA SHEET

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

EI HIGH VOLTAGE INSULATION TESTING POLICY

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

(R) Aerospace First Article Inspection Requirement FOREWORD

Substation HV Cables. Document Number: 1-11-FR-07

Transcription:

Israel Electric Corporation Ltd. - Customer Division - National Network Unit Issued date: February 2018 THE ISRAEL ELECTRIC CORPORATION LTD. National Network Unit Specification No. NPS - 361 for Single Core Aluminum and Copper conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv This issue supersedes specification NPS - 74, NPS-111, NPS-112 Haifa, Israel February, 2018

Page No. 1 of 25 Contents 1 - General 2 - The IECo. catalogue Numbers 3 - Documents to be supplied with the Proposal 4 - Standards 5 - Technical Requirements 6 - Tests 7 - Marking 8 - Packing 9 - Quality Requirements 10 - Prototype approval 11- Questionnaire Appendix A - Test requirements for cables manufactured according to I.E.C. Appendix B - Acceptance Test requirements Appendix "C" - Quality Requirements for Contracts Execution Appendix "D" - Schedule up to prototype approval APPENDIX "E" Statement of manufacturer experience Prepared by: A. Lavian (- signed ) Approved by: N. Grinberg (- signed )

Page No. 2 of 25 1 - General Scope This specification defines the technical requirements of power cables with single core copper and aluminum conductor, extruded solid cross-linked polyethylene insulation (XLPE) of rated voltage U 0 /U=12/20kV and U 0 /U=18/30kV (henceforth referred to as Cables ). The cables are designated to be installed in outdoor or underground networks as follows: a) In system with neutral point normally earthed via Peterson coil with the "Highest System Voltage" Um=24kV (IEC Publication 60183 clause 4.1 - category 2). b) In system with neutral point solidly grounded, with the "Highest System Voltage" Um=36kV (IEC Publication 60183, clause 4.1 category 1). 2 - The IECo. catalogue Numbers The IECo. catalogue numbers vs relevant conductor cross-section: Table 1 Type of Cable Conductor Cross Section (mm 2 ) Rated Voltage (kv) IEC Cat. No. N2XS (F) 2Y 50 Cu 18/30 39305 N2XS (F) 2Y 150 Cu 18/30 39339 N2XS (F) 2Y 300 Cu 18/30 39354 NA2XS (F)2Y 150 Al 18/30 4098950 NA2XS (F)2Y 300 Al 18/30 4098943 NA2XS (F)2Y 50 Al 12/20 4098984 NA2XS (F)2Y 240 Al 12/20 4098976 N2XS (F)2Y 300 Cu 12/20 4098968

Page No. 3 of 25 3 - Documents to be Supplied with the Proposal The Proposer shall submit all the following documents to the IECo. with the bid documents. 3.1 Complete and fill in Questionnaire ; 3.2 A complete Type Test Reports, according to Israeli standard IS 1516-2, issued within the last 7 years preceding the date of the bid, for the proposed cable or for a similar* cable. 3.3 Certificate issued by the Standards Institution of Israel (SII) or any agreed accredited institution, attesting that the Manufacturer meets the requirements of the Israeli Standard IS 1516-2 for MV power cables (identical to IEC standard 60502 part 2) 3.4 Cross-section drawings including dimensions; 3.5 Approval of conformance with ISO 9001 requirements shall be in a form of a certificate issued by a Certification Body (CB) which is accredited by an Accreditation Body (AB). The certificate should bare the logo of the CB and of its AB and/or the logo of the IAF. The certificate shall be valid on the date set for submission of the proposal. The certificate shall be valid for the scope of activities requested in the request for proposal. 3.6 Document approving experience: the manufacturer actively produced and supplied at least 150 km of the proposed cable or similar* cable during a period of at least 3 years during the last 7 years preceding the date of the bid. Additionally, The Proposer shall submit reference list indicating the quantities of the cables manufactured and sold during these years; * Similar cable: Same construction, same conductor cross-section or bigger, the conductor may be either copper or aluminum. ** All the above documents shall be in English.

Page No. 4 of 25 4 - Standards 4.1 Standards referenced in this specification, and in supplements to this specification, form an integral part of this specification. 4.2 All the standards referred to the most current issue, including all amendments, and supplements, as of the date of the bid. 4.3 The cables that are provided under this specification, shall be designed, manufactured inspected, tested and preserved in compliance with the standards as specified herein. 4.4 Relevant standards: 4.4.1 - Israeli Standard IS 65 (IEC Publication 60228) "Conductors of Insulated Cables"; 4.4.2 - IEC Publication 60230 "Impulse Test on Cables & their Accessories" 4.4.3 - Israeli Standard 1516-2 (IEC 60502-2) "Extruded Solid Dielectric Insulated Power Cable for Rated Voltages from 1kV up to 30kV" 4.4.4 - IEC Publication 60811-100 "Common Test Methods for Insulating and Sheathing of Electric Cables " 4.4.5 - IEC Publication 60885-3 "Test Methods for Partial discharge Measurements on Length of Extruded Power Cables" 4.4.6 - IEC Publication 60968 Guide to the Short Circuit Temperature limits of Electric Cables with a Rated Voltage from 1.8/3 kv to 18/30 kv 4.4.7 - HD 620 part 5-C "Cross-linked PE Insulated Cables" 4.4.8 - HD 605 part A1 "Additional Test Method" 4.4.9 - DIN 46391 Delivery Drums In case of differences between the present specification and the above standards, the present specification is mandatory.

Page No. 5 of 25 5 - Technical Requirements 5.1 Operating Temperatures 5.1.1 Maximum rated conductor temperature: 90 C. 5.1.2 Short circuit maximum conductor temperature (for duration up to 5 sec): 250 C 5.1.3 The conductor temperature under emergency condition: 130 C for duration of 8 hours continuously. The total duration of such overloads may exceed 100 hours per annual. 5.2 Construction 5.2.1 Conductor 5.2.1.1 Material: The conductor shall consist of plain annealed copper / aluminum wires. 5.2.1.2 Form: The conductor shall be circular compacted stranded. 5.2.1.3 Dimensions: Table 2 hereafter sets out the cross-sectional areas and characteristics of the Table 2 Nominal Cross- Section (mm 2 ) conductors covered by this specification. Rated Voltage (kv) Diameter Range (mm) Minimum Number of Wires Max. DC Resistance at 20 0 C ( /km) 50 Cu 18/30 7.7 8.6 6 0.387 150 Cu 18/30 13.9 15.0 18 0.124 300 Cu 18/30 20.0 21.6 34 0.0601 150 Al 18/30 13.9 15.0 15 0.206 300 Al 18/30 20.0 21.6 30 0.100 50 Al 12/20 7.7 8.6 6 0.641 240 Al 12/20 17.8 19.2 30 0.125 300 Cu 12/20 20.0 21.6 34 0.0601

Page No. 6 of 25 5.2.2 Conductor Screen 5.2.2.1 The conductor screen shall consist of an extruded cross-linked semi-conducting compound layer (HD 620, part 5-c subclause 2.2). This inner-semiconducting layer shall not penetrate into the inner wire layers of the conductor and shall be easily removable during installation. The wall thickness of the inner-semiconducting layer shall be at least 0.3 mm. 5.2.2.2 The irregularities in the conductor screen, shall be of sizes specified in subclause 2.5 of the standard HD 620, part 5-c. 5.2.2.3 The Resistivity both before and after aging, shall not exceed 1000 m. 5.2.3 Insulation 5.2.3.1 The insulation shall be of extruded cross-linked polyethylene (XLPE). 5.2.3.2 The process of cross-linking or vulcanization may be achieved by any method except "Curing in Steam" process. 5.2.3.3 The nominal thickness, not including the thickness of any separator or semiconducting screen on the conductor and over the insulation, shall be 5.5 mm for cables with rated voltage U0/U = 12/20 kv and 8 mm for cables with rated voltage U0/U = 18/30 kv. 5.2.3.4 The average thickness of the insulation shall not be less than the specified nominal value. 5.2.3.5 The thickness at any place may however be less than the specified nominal value provided that the difference does not exceed 0.1 mm +10% of the specified nominal value (IEC 60502-02, sub-clause 17.5.2). 5.2.3.6 Wall thickness difference of the insulation between the lowest and the highest values in one measured plane shall not exceed 0.9 mm (HD 620-5c).

Page No. 7 of 25 5.2.3.7 The diameter over the insulation cover shall fall within the limit values specified in Table 3: Nominal Cross- Section (mm 2 ) Table 3 Rated voltage (kv) Nominal Thickness (mm) Minimum Insulation Diameter (mm) Maximum Insulation Diameter (mm) 50 Cu 18/30 8 25.2 26.7 150 Cu 18/30 8 31.5 33.5 300 Cu 18/30 8 37.6 39.6 150 Al 18/30 8 31.5 33.5 300 Al 18/30 8 37.6 39.6 50 Al 12/20 5.5 20.2 21.7 240 Al 12/20 5.5 30.6 32.6 300 Cu 12/20 5.5 32.6 34.6 5.2.3.8 The irregularities (voids, impurities) in the insulation shall not exceed 0.2 mm as specified in subclause 3.3 of standard HD 620 part 5-C.

Page No. 8 of 25 5.2.4 Non-Metallic Insulation Screen 5.2.4.1 The semi-conducting screen shall be applied directly over the insulation and shall consist of an extruded cross linked polyethylene. The semi-conducting screen shall be non-peelable (bonded). 5.2.4.2 The maximum thickness of the semi-conducting screen shall be of 0.6 mm for all the cables covered by this specification. 5.2.4.3 The minimum thickness of the semi-conducting screen shall be of 0.3 mm for all the cables covered by this specification. 5.2.4.4 The diameter difference over the non-metallic insulation screen between the lowest and the highest value shall be maximum 0.5 mm. 5.2.4.5 The inner and the outer semi-conducting layers shall not present any surface roughness, it shall be smooth, and shall adhere perfectly to the insulation all along its periphery. 5.2.4.6 The electric Resistivity of the layers, both before and after aging, shall not exceed 500 m at 20 0 C. 5.2.4.7 Conductor screen, insulation and insulation screen shall be laid by triple extrusion process. 5.2.5 Semi-conductive Bedding Tape A swelling semi-conductive bedding tape shall be applied (lapped) all over the non-metallic insulation screen. 5.2.6 Metallic Screen 5.2.6.1 A metallic screen shall be applied helical over the bedding semi-conductive tape. The screen shall consist of a concentric layer made of copper wires, bounded together with one or two copper tapes, having thickness of at least 0.1mm and a minimum cross-sectional area of l mm 2. The copper tape shall be applied helical so that the helix lay will not be greater than the cable diameter underneath the concentric layer of copper wires times 4.

Page No. 9 of 25 5.2.6.2 The metallic screen dimensions and characteristics for each conductor shall be as specified in Table 4 hereafter of this specification. Table 4 conductor Cross- Sectional area [mm 2 ] Rated Voltage (Kv) Total Cross- Sectional Area of the Screen Wires [mm 2 ] Wires Minimum Diameter [mm] Max DC Resistance of the Screen at 20 0 C [ /km] 50 Cu 18/30 16 0.5 1.150 150 Cu 18/30 25 0.5 0.727 300 Cu 18/30 25 0.5 0.727 150 Al 18/30 25 0.5 0.727 300 Al 18/30 25 0.5 0.727 50 Al 12/20 16 0.5 1.15 240 Al 12/20 25 0.5 0.727 300 Cu 12/20 25 0.5 0.727 5.2.7 Watertight Measures 5.2.7.1 The cables shall be longitudinally watertight protected on the screen area. 5.2.7.2 The watertight layer shall be made of special swelling tape. 5.2.8 Oversheath 5.2.8.1 The oversheath shall be made of HDPE polyethylene compound, ST7 type (IEC publication 60502-2 table 4). 5.2.8.2 The color of the oversheath shall be black 5.2.8.3 The nominal thickness shall be 2.5 mm and the minimum thickness shall be not less than 2.03 mm for all the cables covered by this specification.

Page No. 10 of 25 5.2.8.4 The external diameter of the oversheath shall fall within the limits specified in Table 5 hereafter: Table 5 Conductor Cross-Sectional area [mm 2 ] Rated Voltage (kv) Min. Oversheath Diameter [mm] Max. Oversheath Diameter [mm] 50 Cu 18/30 33 39 150 Cu 18/30 39 45 300 Cu 18/30 46 52 150 Al 18/30 39 44 300 Al 18/30 43 48 50 Al 12/20 28 33 240 Al 12/20 39 44 300 Cu 12/20 41 46

Page No. 11 of 25 6 - Tests 6.1 General Tests shall be performed in accordance with the requirements of Annex A of this specification and will meet the latest published recommendations of the standards prescribed under clause 4 of this specification, by and at the expense of the Contractor. In case that the Proposer has a type test of one of the said standards, he will complete the tests according to Annex A. 6.2 Type Tests 6.1 Type Test Within 3 months after from the date on which a binding contractual obligation has been created, the Contractor shall submit type test report that was performed on the first manufactured batch of the cable to be supply to the IECo. The type test shall be performed according to Annex "A" in an independent authorized laboratory (ISO/IEC 17025 or EN 45011 approved). The IECo. reserves the right to attend during the performance of the Type Test Exemption: If the Contractor had supplied identical cable to the IECo. during the last 7 years preceding the date of the present bid, and if the manufacturing method was not changed, the Contractor can introduce type test report if it was approved by the IECo. in the former supply. 6.2 Routine Tests The Contractor shall perform and submit test reports for all routine tests for each cable that is wrapped on each drum. The Contractor shall submit to IE Co. the routine test reports for approval prior to delivery of the cable The cable shall be delivered only after approval of the routine test report of the cable.

Page No. 12 of 25 6.3 Acceptance Test Acceptance tests shall be performed according to the standards in para. 3 and shall include tests required in Appendix "B" In case that the cable under test will not fulfill all requirements specified in Appendix "B" the IECo. has the right to reject the consignment. 6.4 The tests shall be performed by and at the expense of the Contractor. The contractor shall make all the necessary arrangements to enable the IECo. s inspectors to be present at the tests. 6.5 The following data shall be indicated on each test certificate: Manufacturer's name; Name and address of the testing laboratory; Serial number of the test certificate; The certificate issue date; Test report of special test shall specify the pertained batch number of the cables; A signature of the person responsible for tests and his position. 6.6 The test certificate should contain results for each test according to the test requirements with reference to appropriate Clauses and Sub-clauses of standards and this specification.

Page No. 13 of 25 7 - Marking 7.1 Throughout whole cable length, at intervals not exceeding 100 cm, the following identification marks shall be indelibly imprinted in white color, embossed or by reproduction in relief on the outer sheath. a) Manufacturer s name or trade mark (logo) b) The structure: " N2XS (F) 2Y - l x (cross-sectional area in mm 2 ), 18/30 kv " c) Year of production d) "Property of the Israel Electric Corp." e) Running length (in meters) No. marked on each one of the cable ends (the first and the last No.) 7.2 The following data shall be printed legibly on a tag strongly attached onto each drum: f) Manufacturer's Name g) Manufacturer's Plant address h) The IECo. Order No. i) Drum Serial No. j) Manufacturing Date k) Cable Type l) Cross Sectional Area in mm2 m) Cable Length n) Gross Weight o) Cable Standard p) The IECo. Catalog No. q) The IECo. Specification No. (NPS-361)

Page No. 14 of 25 8 - Packaging 8.1 The cables shall be furnished in lengths of 500 (±5) meters wound on seaworthy metal drums. The cable on the drum shall be protected against damage by a suitable cover easy to remove, mounted around the drum flanges, so that the drum shall be closed from all sides. 8.2 The supplied drums shall be according to DIN 46391 with max. flange diameter 2240 mm and max. overall width 1200 mm. 8.3 The cable's ends shall be supplied with hermetically sealed with watertight caps that shall prevent the ingress of humidity and fine dust into the cable's ends. 8.4 COT attesting the purity and composition of the conductor raw material shall be attached to each consignment. 8.5 The loosed cable end shall be fastened to the drum's flange, with a proper steel band. 8.6 In order to install an electronic drum-locator device, a niche of 130 mm X 65 mm with depth of 20 mm should be carved out on the side of one of the wooden flanges (if relevant). 9- Quality Requirements For quality system and other specific quality requirements, see Appendix A: Q-APP-02. Bidder shall submit with his proposal the following (In English): Quality system Certificate; Quality manual; Certificates that demonstrate the Bidder's compliance with the requirements specified or implied in this specification; Example of an inspection & test plan and/or Quality plan which pertain to the cable to be supplied; Formal confirmation that he will conform to the requirements of Q-APP-02.

Page No. 15 of 25 10 PROTOTYPE APPROVAL 10.1 Prototype approval for new suppliers. New supplier Supplier that didn t supply the ordered item to the IECorp. in the last five (5) years. 10.1.1 In a period of max three (3) months from the date on which a binding contractual obligation has been created, and before production for IEC of all ordered items, the Contractor shall perform Prototype Approval 10.1.2 For purposes of the Prototype approval, the manufacturer shall perform the complete type tests as required in this specification. 10.1.3 The contractor shall be responsible to conduct successfully all the necessary tests, and to deliver to the Israel Electric Corp. all the necessary required reports, in a manner, which will not interfere with or delay any of the time schedules, pertaining to any action or undertaking, required of the winning bidder, including, but not limited to delivery schedule. Such responsibility shall include proper and reasonable advance notifications to the Israel Electric Corp., prior to any action, required of it. If type and special tests have already been conducted with reference to the identical cable which is offered by the proposed and the Israel Electric Corp. approves the reports, pertaining to such tests, the Israel Electric Corp. shall have a right (but not a duty) to waive all or part of the required tests. 10.1.4 The Israel Electric Corp. reserves the right to cancel the order for the supply of equipment if the prototype will not be approved by the Israel Electric Corp. In any case, the contractor shall not resume manufacture of the rest of the ordered equipment before receiving the Israel Electric final approval of the prototype. 10.1.5 Required schedule up to prototype approval (after notification of award) is attached in APPENDIX: "D".

Page No. 16 of 25 10.2 Prototype approval for existing suppliers. Existing supplier Supplier who supplied the ordered item to the IECorp. in the last five (5) years. 10.2.1 Existing supplier is exempted from prototype if in the technical bid the supplier will provide to IE Corp. a letter with the following data: - The period and type of the ordered item supplied to IECorp. - A statement that was no any changes in the production line.

Page No. 17 of 25 11 Questionnaire Tender No.: Subject Name of Proposer : Insert all data in this column Manufacturer s name and address: Specify the standards that the cable will comply with: 1 Cable 1.1 Coding 1.2 Rating voltage (U0/U) (kv) 1.3 Current rating (in soil having 1 km/w at 30 0 C at a load factor of 1.0 laying depth 0.7 m) (A) 1.4 Short circuit rating current for 1 sec duration (A) 1.5 Corona level (pc/kv) 1.6 Inductive resistance at 50 Hz (Ω /km) 1.7 AC effective resistance at 90 0 C (Ω /km) 1.8 Capacitance ( F/km) 2 Conductor 2.1 Material 2.2 Nominal cross-sectional area (mm 2 ) 2.3 Number and nominal diameter of wires (mm) 2.4 Designed diameter (mm) 2.5 Max DC resistance at 20 0 C (Ω/km)

Page No. 18 of 25 2.6 Max permissible continuous temp. ( 0 C) 2.7 Max permissible Short circuit temp. ( 0 C) 3 - Conductor Screen 3.1 Material 3.2 Min thickness (mm) 3.3 Max electrical resistivity at operating temp. (Ohm/km) 3.4 The irregularities sizes (mm) 4 - Insulation 4.1 Material 4.2 Nominal thickness (mm) 4.3 Nominal diameter (mm) 4.4 Difference between lowest and highest value of wall thickness in one measured plain (mm) 4.5 Dielectric permeability 5 - Non-Metallic Insulation Screen 5.1 Material 5.2 Extruded layer peelable / non-peelable 5.3 Thickness (min max) (mm) 5.4 Max electrical resistivity at operating temp. (Ohm/km) 5.5 Difference between lowest and highest value of wall thickness in one measured plane (mm) 6 - Bedding semi-conductive tape is applied on the nonmetallic insulation screen (yes/no) 7 - Metallic Screen 7.1 Number and diameter of wires (mm) 7.2 Number, thickness and width of tapes (mm) 7.3 Nominal cross-sectional area (mm 2 ) 7.4 Electrical resistance at 20 0 C (Ω /km)

Page No. 19 of 25 8 - A swelling tape shall be applied over the metallic screen (yes/no) 9 - Outer Sheath 9.1 Material 9.2 Nominal thickness (mm) 9.3 Nominal diameter (mm) 9.4 Difference between lowest and highest value of wall thickness in one measured plane (mm) 9.5 Color 9.6 Marking embossed according subclause 7 10 - General Data 10.1 Cable weight (kg/m) 10.2 Permissible bending radius (m) 10.3 Permissible pulling force (kg) 11 - Drum 11.1 Type 11.2 Material 11.3 Weight of empty drum (kg) 11.4 Flange diameter (cm) 11.5 Barrel diameter (cm) 11.6 Overall Width (cm) 11.7 Gross weight (drum with cable) (kg) 11.8 Length of cable per drum (m) 12- Packing 12.1 A tag with all details as required in subclause 8.1 shall be attached (Yes/No) 12.2 The cable shall have sealing caps (Yes/No) 12.3 The drum shall be protected as required in clause 8.2 (Yes/No)

Page No. 20 of 25 13 - Attached Documents 13.1 Valid ISO 9001 certificate (Yes / No) 13.2 Catalogue (Yes / No) 13.3 Cable drawing (Yes / No) 13.4 Certificate issued by the Standards Institution of Israel (Yes /No) Proposer s address: Email address: Contact : Tel. No. : Cellular : Fax. No. : Date: Signature:

Page No. 21 of 25 Annex "A" TEST REQUIREMENTS for MEDIUM VOLTAGE CABLES

Page No. 22 of 25 Annex "B" SPECIFICATION for ACCEPTANCE TESTS of MEDIUM VOLTAGE CABLES Haifa - Israel

Page No. 23 of 25 ANNEX "C" ORGANIZATION, QUALITY AND SAFETY DIVISION QUALITY CONTROL UNIT APPENDIX FOR CONTRACTS / ORDERS REV. 4 Volume 03/ 2011 Spec. No. Q - APP - 02 QUALITY REQUIREMENTS

Page No. 24 of 25 Appendix. D Schedule for prototype approval

Page No. 25 of 25 APPENDIX "E" - STATEMENT OF MANUFACTURING EXPERIENCE I, (Enter name), do hereby state the following: 1. I am a position holder at ("The factory") occupying the position of (Enter job title and description, i.e. partner, production manager, sales manager, etc.) 2. I have been occupying this position since (Enter date). 3. I give this statement in regards to I.E.C Tender number ("The Tender"). 4. The facts/details given in this statement have been checked and verified by me. 5. (The factory) has actively produced and supplied at least 150 km of the proposed cable or similar* cable during a period of at least 3 years during the last 7 years prior to submission. * Similar cable: Same construction, same conductor cross-section or bigger, the conductor may be either copper or aluminum. 6. I hereby undertake to provide, upon IEC's request and at its sole discretion, any other documents (reference list, quantity,dates of supply, letter of recommendations etc ) or other information requested for this Tender for purposes of proving said experience. Signature Date