Help. Appendix A Camera Settings. IncuCount

Similar documents
Instruction Manual for the Revolutionary Science RS-IC-150 IncuCount

Instruction Manual for the Revolutionary Science RS-IC-100 IncuCount

eflex 75x/300x Digital Microscope with Flexible Neck User Guide

KoPa Scanner. User's Manual A99. Ver 1.0. SHENZHEN OSTEC OPTO-ELECTRONIC TECHNOLOGY CO.,LTD.

WELCOME WHAT S IN THE BOX

Smartphone RH/Temperature Probe Instruction Manual

INSTRUCTION MANUAL INF Fax: (503)

User Manual. This User Manual will guide you through the steps to set up your Spike and take measurements.

ONYX Deskset HD. Portable Video Magnifier User s Guide. Freedom Scientific, Inc Revision A

Motic Live Imaging Module. Windows OS User Manual

Micro-Image Capture 8 Installation Instructions & User Guide

Wireless Handy Scanner

1. Limited Warranty. 2. Limited Remedies

SKF TKTI. Thermal Camera Software. Instructions for use

Welcome to Polaroid PhotoMAX FUN!

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

Digital Portable Overhead Document Camera LV-1010

S100 Webcam. User s Manual

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

IR Flash USER GUIDE. Professional Thermal Image Analysis Software. Manual Version West Cardinal Drive Beaumont, Texas 77705

inphoto ID Canon camera control software Automatic ID photography User Guide

RAZER RAIJU TOURNAMENT EDITION

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide

CHROMACAL User Guide (v 1.1) User Guide

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

WiFi Photo & Document Scanner User Guide

S101v2 Webcam with adjustable focus

Manual. ios App. Ver2.2. v Mall Drive, Commack, NY (P) (F)

USER GUIDE Third Generation For Android and ios

Case Air Wireless TETHERING AND CAMERA CONTROL SYSTEM

Photoshop CC Editing Images

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

User Guide. High Performance Document Scanner FOR WINDOWS ENGLISH DEUTSCH FRANÇAIS ITALIANO ESPAÑOL PORTUGUÊS РУССКИЙ

FLIR Tools Mobile for Android

Flat Sample Holder Part Number

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide

Supplement. ScanMaker i280 features, scenarios, and information. Getting to Know Your ScanMaker i280

X-Mag. High-Magnification Workstation User s Guide Revision A

P3PC ENZ2. Basic Operation Guide (Mac OS)

Select your Image in Bridge. Make sure you are opening the RAW version of your image file!

23070 / Digital Camera Owner s Manual

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

Quick Start Overview. Related Information. In addition, the sensor includes integrated Help.

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS

MICRO SERIES MONITORS

Guidance on Using Scanning Software: Part 5. Epson Scan

RAZER GOLIATHUS CHROMA

Minolta Scanner Plugin

Apple Photos Quick Start Guide

INSTRUCTION MANUAL LKG

SPM-50 RF Spectrum Power Meter PC Software User Manual

Family HD Webcam F101

Third Generation For Android

ES-400/ES-500W/ES-500WR User's Guide

DM-46 Instruction Manual

USER MANUAL PFF-1010BLACK

PRORADAR X1PRO USER MANUAL

Skin Scanner. with Internal Camera. Operator & Owner s Manual Model #GP-DV-C

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

EQ-AMP60 60W Mixer Amplifier

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

F400 QUICK-START GUIDE

COPYRIGHT. Limited warranty. Limitation of liability. Note. Customer remedies. Introduction. Artwork 23-Aug-16 ii

Savant Lighting TrueImage App Setup Guide

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

Case Air Wireless TETHERING AND CAMERA CONTROL SYSTEM

ApexDesk Assembly Guide

ClearClick Photo2Digital 10 MP Photo, Slide, & Negative Scanner

Important Safety Information

TM Quick Start Guide

How does the Barbie Polaroid camera work? Check it Out!

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

PROGRESSIVE JACKPOT MARQUEE

RUSH G1 MECHANICAL KEYBOARD PRODUCT MANUAL V.14

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

Virtual Painter 4 Getting Started Guide

ScanGear CS-U 5.6. for CanoScan FB1210U Color Scanner. User s Guide

Quick Start Guide. Setup and Scanning. Try the Additional Features. English

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

FTA SI-640 High Speed Camera Installation and Use

EPSON Stylus Color 480SXU

Tribometrics. Version 2.11

Google Geo Education Tutorial. Ricoh Theta-S & Street View App

P3PC ENZ2. Basic Operation Guide (Mac OS)

2500 Series All-In-One

Desktop Compact Film Scanner

EVOS M5000 Imaging System

lighting your creativity HONEY BADGER 320Ws Digital Flash Instruction Manual

ID Photo Processor. Batch photo processing. User Guide

stored on the micro SD card supplied with the product and accessed when you come back to your computer.

GlassSpection User Guide

Digital Photo Guide. Version 8

600A Clamp Meters w/tightsight Display

HTC VIVE Installation Guide

Mini Photo Printer User Manual

Installation & User Manual Micro-Image Capture 7

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

MedRx Avant Polar HIT AH-I-MPHITS-5 Effective 11/07/11

Transcription:

Help The help menu has three items: About - will give company name and model information User Guide - will open up this document. Contact information - for Revolutionary Science's Technical support. Email: support@revsci.com Telephone contact: 651-674-3112 www.revsci.com Appendix A Camera Settings Focus Adjust focus for better clarity Brightness Adjusting Brightness lightens or darkens the image. Contrast Adjusting contrast heightens or lessens the difference between light and dark areas in the image. 25

Antibiotic Reactions, Measurement of Inhibition Zones Tap on Light Colonies or Dark Colonies on the top menu bar. If disks on the screen appear light in color then tap on Antibiotic (Light). If disks on the screen appear dark in color then tap on Antibiotic (Dark). Then tap on the Count button in the lower right side of the screen. The software will identify the disks with green inhibition zones. Then tap on Manual and then on Add Well. This will allow the user to manually adjust each the diameter of each green zone. Manually Add or Delete Inhibition Zones To manually add a well tap on the Manual tab at the top and then on Add Well. Then tap on the image where you want to add a new well. The new well will show up as a green dot. Note: added wells will show up in the notes section on the right side of the screen. To manually remove a well tap on the Manual tab at the top and then on Remove Well. Then tap on the well you want to remove. Instruction Manual for the Revolutionary Science REVOLUTIONARY SCIENCE Making Science Simple! Table of Contents Introduction 2 Parts Checklist, Notes, Service Record 3 Warranty 4 Safeguards and Cautions, Limitations of Use 5 Intended Use 7 Specifications, Contact Information 8 Hardware Installation (Model RS-IC-150) 9 Quick Start 10 Step-By-Step Comprehensive Setup 10 Wi-Fi Setup 12 Automatic Updates 13 Colony Profile Setup 13 Saving a Colony Profile 14 Calibration Image 14 Setup Lighting, Focusing, Brightness and Contrast Controls 16 Live Video Feed 18 Capturing Images 18 Colony Counting 19 Count Sensitivity 20 Count Region 20 Colony Size 21 Colony Shape (Morphology) 21 Zoom 22 Adding/Removing colonies from count 22 Exclusion Zone 22 Selecting Previous Image 23 Saving Data 23 Export to PDF 23 Antibiotic Reactions Measurement of Inhibition Zones 24 Help 25 Appendix A-Camera Settings 25 24 17319 Lake Blvd. Shafer, MN 55074 Toll Free: (800) 775-7942 Fax: (775) 218-7015 E-mail: support@revsci.com Website: www.revsci.com 1

Introduction Dear Valued Customer, Thank you for purchasing the Revolutionary Science. We are confident that our will provide years of reliable service. We have made every effort to use high quality, durable parts to deliver the performance expected of instruments costing 2 to 3 times as much. You may enjoy visiting our web site at www.revsci.com. Please let us know what you think of our products, positive or negative, so we can continue to enhance and improve our products in the future. Selecting a Previous Image/Data Tap on File and then tap on Load Image. The Load Image list of previous images will appear. Select desired image and confirm. Saving Data Tap on File and then tap on Capture Image. This brings up a Saved As menu. Type in desired name for the file and tap enter. Sincerely yours, REVOLUTIONARY SCIENCE Export to PDF Tap on File in the top menu and tap on Save PDF. This brings up a Saved As menu. Type in desired name for the file and tap enter. NOTE: This manual contains important information, safeguards and operating instructions for the operation of the REVOLUTIONARY SCIENCE by Alternative Pioneering Research & Development, Inc. (APR&D, Inc.) 2 23

Zoom The software uses what is typically known as pinch and zoom method. To zoom in on a spot simply touch the screen with two fingers together and then slide them apart. To zoom out on an area touch the screen with two fingers apart and then slide them together. Parts Checklist Carrying case _ Light aperture ring _ Tablet CPU _ Tablet CPU Stand _ USB Belkin Hub _ Power OTG cable _ Detachable power supply w/ barrel connector _ Detachable power supply w/ USB connector _ Manual Zoom in Zoom out Manually add colonies Tap on the Manual tab at the top and then on Add Colonies. Then tap on the image where you want to add a new counted colony. The new counted colonies will show up as a white dots. Note: added colonies will show up as a positive figure under Colonies added in the notes section on the right side of the screen. Notes & Service Record For your own future reference and to expedite answers to your questions, please complete the following information: Date Purchased Manually remove colonies Tap on the Manual tab at the top and then on Remove Colonies. Then tap on a green counted colony to remove it. This will now show a red mark. Note: removed colonies will show up as a negative figure under Colonies added in the notes section on the right side of the screen. Exclusion zone To exclude an area from counting, tap on Manual on the top menu and then tap on Exclusion Zone. Then tap around the region you want to exclude (four separate taps). The highlighted exclusion zone area will then appear. To remove an existing exclusion zone double tap inside of the zone. Serial Number Model Number Purchased From Your Notes: 22 3

Warranty Warranty Registration Please complete out this page, or a copy of it, and send it to the address below to validate your warranty. Warranty Registration Card for the REVOLUTIONARY SCI- ENCE. (Please Print) Date Purchased: Serial Number: Purchased From: (Please check one) Company School Individual Name of Department or Institution: Adjusting Colony Size Parameters Tap on the Manual tab at the top and then on Set Colony Size option. You will then see the sliding Max/Min scale to the right side of the screen. To increase the minimum allowable colony size slide up. To decrease the minimum colony size slide down. To change the maximum allowable size, adjust the Max slider. Adjusting Colony Shape Parameters (morphology) To include long skinny objects as colonies, adjust the L to W Ratio (Length/Width) slider up. To exclude long skinny objects from the count, adjust the slider down. Address: Intended use: Where did you hear of our product? Comments: Warranty Policy Your REVOLUTIONARY SCIENCE is warranted to be free from defects of material or workmanship under normal use for a period of two years from date of purchase. If your proves to be defective within this warranty period, APR&D, Inc. will repair or replace your unit at our option. This warranty will be void if malfunction is caused by accident, misuse, or negligence, including tampering, abuse, or damage in transit. This warranty excludes any relief for incidental or consequential damages. 4 21

Adjusting the Count Sensitivity Locate the blue vertical sensitivity bar (located between the image and notes section). To increase sensitivity, slide the bar up. To decrease the counting sensitivity slide blue vertical sensitivity bar down. A sensitivity of 0 means the average background color will be counted. Note: Higher sensitivity is usually needed more with lighter colored colonies and lower sensitivity is usually needed more with darker colored colonies. Adjusting the Counting Region To adjust the counting region tap Set Counting Region under the manual tab. To recenter, tap Center in the dialog that appears. To adjust size, by one unit, tap the + or - buttons. Tap the '+5x' or '-5x' to increase/decrease the size by 5 units. (A unit is.125mm.) Safeguards & Cautions To maximize the use of the, please follow the recommendations in this short list before using: 1. Examine carton and contents for possible damage to the product caused during shipping. If damage is present contact carrier at once. Failure to do so immediately may release the carrier from any liability of damage. 2. Fill out the checklist (page of instruction manual). If something is missing please contact us. 3. Carefully read this instruction manual before operating the. 4. Fill out warranty registration card and mail it to APR&D, Inc. Limitations of Use *Revolutionary Science is not responsible for misuse of the 1. ALWAYS pre-clean the light panel of residue after use with a damp cloth and appropriate mild detergent solution. Never clean with organic solvents like thinner or benzene. It will damage the surfaces. CAUTION: This is the only recommended method of cleaning. 2. Never attempt to dismantle or modify the. 3. Never operate the with a damaged USB cord or after the appliance malfunctions or has been damaged in any manner. 4. Accessory attachments not recommended by Revolutionary Science may damage the or tablet cpu. 5. Never place the or any part of the in an environment that exceeds 65 degrees Celsius or below 5 degrees Celsius. Humidity should be at or below 65%. 6. Never use for any purpose other than the intended use. 20 5

7. When used in higher temperatures, the may be uncomfortable to the touch. When removing the from the incubator, it is recommended to use temperature resistant gloves or turn off the incubator and allow the to cool to a comfortable temperature before removing it. 8. Never attempt to modify the plugs or cords. This may cause damage to the or tablet cpu. 9. Never immerse the, cord, or plug in water or operate on wet surfaces. 10. Never allow the cords to contact hot surfaces beyond 65 C. Any slack in the cord should be wrapped up and held together with a band. Colony Counting To count an image, tap the COUNT button on the lower right side of screen. The results will appear in the notes box on the right side of the screen. In the image, colonies will be colored green, while those too large or small appear as red(see Sensitivity and Colony Size sections on pages 16 and 17). The can differentiate colonies based on color. To turn on this feature, select the color checkboxes that most closely match the colony color. For example, to count purple vs. blue colonies, select the purple and blue checkboxes and click 'Count'. The count of each colony type will appear next to the selected colored checkboxes. If no checkbox is checked, the count will default to the green color. Note: Before counting, you may need to adjust the sensitivity and/or the counting region. 6 19

Live Video Feed (Preview) Intended Use When Preview is shown on top menu bar image displayed is live. When Pause is shown on top menu bar image displayed is fixed. The Pause mode is setting which all counting occurs Capturing Images To capture an image for counting or measuring an inhibition zone, tap the CAPTURE button under the File dropdown menu. Note: Before capturing, you may need to adjust the focus and lighting. The Revolutionary Science can be used for the following purposes: 1. Colony Counting: Count colonies on Petri dishes Multi color colony recognition 2. Measure the inhibition zones of antibiotic samples Manual Automatic 3. Monitor inside an incubated environment Count colonies as they grow in real time Measure inhibition zones as anti-biotic reactions occur in real time Email images 18 7

Specifications Power requirements: Net weight: Dimensions: Lights: Camera: CPU: Petri dish size capacity: Certifications: Warranty: 100-240 VAC 60 HZ 1.5 amps 5 lb. (shipping weight 14 lb.) 7.25 inches tall x 6.50 inches diameter High intensity LED lights, top and bottom High-resolution digital camera, Carl Zeiss Optics Android based operating system Compatible with USB flash drive Up to 100 mm in size, including 3M Petri Film UL approved LED lights, power supply, & camera Compatible with FDA 21 CFR part 11, export as PDF 2 year, repair or replacement Camera Controls Focusing, Exposure, Brightness and Contrast Controls Make sure camera mode is in preview (will show as 3rd tab on top menu bar). To adjust the image focus, exposure, brightness or contrast tap on Camera Controls and then tap on Manual controls. The controls will then appear on the right side of the screen. Simply slide up or down for adjustment. Contact Information Revolutionary Science 17319 Lake Blvd Shafer, Minnesota 55074, USA Customer Service: (800) 775-7942 Technical Assistance: (651) 674-3112 Fax: (775) 218-7015 Web site: www.revsci.com E-mail: support@revsci.com 8 17

Setup Lighting, Focusing, Brightness and Contrast Controls Hardware Installation Install hardware as shown in diagram below. (Model RS-IC-150) Light Control The comes equipped with an upper and a lower bank of LED lights. To increase or decrease the intensity of these lights, turn knob located in the back of the unit. The left knob controls the lower bank of lights and the right knob operates the upper bank. We recommend using the lower lights on a setting of two for most samples. Light Aperture Place the light aperture (black ring) into the unit on the light box. Note: The purpose of this important mechanism is two fold. 1. Centers the Petri dish in the camera's field of view 2. Blocks out excess light around the Petri dish, providing the best possible view of the sample. 16 9

START COUNTING From out of the box to counting colonies Tap Save in the Profile controls menu and give the image a name. This image is saved in a calibration folder for future use. Quick 1) Setup device (as seen on page 9) and turn on. 2) Adjust lighting by use of the rotary switches in back. 3) Click count. Comprehensive 1) Connect the base to the Android tablet as shown on page 9. Make sure all components (USB hub, tablet, base, USB OTG cable, power supply) are all connected correctly. 2) Turn on the Android tablet by holding in the power button for until the boot screen (Google) appears. The device should boot up straight into the Software. 3) Check the optics by placing a blank Petri dish into the stage of the base. A view of the Petri dish should appear on the screen. 4) Change the lighting by adjusting the Lighting knobs (p.16). We recommend using the lower lights on the second setting for most plates. 5) Auto focus and exposure are enabled by default. For manual camera adjustments, tap on Camera Controls in the menu bar, then select Manual Controls. Adjust the focus, brightness and contrast by moving the slider bars in the dialog that opened up until the desired contrast and brightness is reached (See Camera Controls, p.17). 6) Pause the image by tapping Preview in the menu the selecting pause. This will freeze the current frame in the camera for counting. 7) Adjust the counting region by tapping Manual in the menu bar then selecting Set Counting Region. Tap Center in the dialog that opens up and + or to resize the counting area. The counting area will be shaded in green. Centering works best with a blank or no Petri plate in the viewing area. 8) Place your sample Petri plate in the. Make sure Preview is selected. 9) Move the Sensitivity Slider up or down until the best count is reached. Colonies outlined in green are counted. Those Colonies outlined in red are either to big or too small (See Adjusting Colony Size, p.21) 10) Limit the size of detected colonies by Tapping Manual in the menu and selecting Set Colony Size. Adjust colony size by moving the min and max size sliders to desired parameters. Colonies outside of parameters will be outlined in red. Applying the Calibration Image To apply the calibration image, check the apply checkbox. The image will appear with the light gradient filtered out. Uncheck the box and the calibration image will be removed. 10 15

Saving a Colony Profile To save the profile, give the profile a name and click the enter button. Any type a change is made to the profile, it needs to be saved. 11)Save the desired parameters by tapping Save. This will save a profile that will be automatically loaded the next time the app is used. 12) Tap the count button to count the sample and view the details of the count. 13) If a PDF copy is desired, Tap File then select Save PDF. 14) To save a copy of the image, tap File then select Capture Image. Give the image a name and it will be saved to the _images directory on the tablet. 15) To save the count data, tap File then Save Data. 16) To perform a new count, Tap the > button to the right of Count. A new image will be taken and counted with the previous saved parameters. If the camera needs adjusting again, Tap Pause then select Preview. Making a Control Calibration Image If the lighting isn't even throughout the agar plate, it may be necessary to make a calibration or control image to help filter out an unwanted light gradient. To do this, place a blank agar plate of the same type being counted into the. Make sure preview is on and adjust the camera and light settings to give the best image. 17) To receive automatic updates, turn on WI-FI (see p.12). 14 11

Wi-Fi Setup To enable Wi-Fi (to receive automatic updates to the software), swipe down on the wifi icon (below) in the upper right corner of the tablet screen. Select the Wi -FI option. Automatic updates The engineers at Revolutionary Science are striving to make the feel and accuracy of the software better and better. To this end we release updates from time to time. As updates become available, they can be installed seamlessly by swiping the notification bar (upper left hand corner of the screen) and clicking Update Available option. The update will then download onto the tablet. Install the update when download is complete. Select your network and type in your network key and press Connect. When connected to the internet through wi-fi, the tablet can receive updates as they become available. Colony Profile Setup Many of the settings can be programmed in and saved for each agar/colony type being counted. To make a colony profile, simply adjust the camera settings (p15), sensitivity settings (p.18) and click Save Profile. 12 13