ONE-LOK Series SLC/SLCE Restraint for AWWA Use the SIGMA ONE-LOK Series SLC/SLCE restraint for AWWA pipe at mechanical or push-on joint ductile iron fittings. The ONE-LOK Restraint Systems can successfully be used for the restraint of Molecular Oriented PVC s manufactured in accordance with AWWA. Rated pressure of the restraint is limited to the rated pressure of the PVC pipe. Sample Specification for Restraint: Restraint for standard mechanical joint fittings shall be incorporated in the design of the follower gland and shall utilize multiple wedge segments that act against the pipe, increasing their resistance as the line pressure increases. The assembled joint shall maintain the maximum flexibility and deflection of all nominal pipe sizes after burial. Restraining gland, wedge segments, and actuating bolts shall be manufactured of high strength ductile iron conforming to the requirements of ASTM A536, Grade 65-45- 12. Dimensions shall be compatible with standardized mechanical joints conforming to the requirements AWWA C111/ANSI A21.11 and AWWA C153/ANSI 21.53 through 24 (latest revision). Breakaway tops shall be incorporated in the design of the actuating bolts to visually ensure proper torque. The manufacturing of the actuating bolt must incorporate a quality control procedure that is deemed acceptable by the specifier and positively assures precise and consistent operating torque of the breakaway top. The mechanical joint restraining devices shall have a working pressure rating of 200psi minimum and provide no less than a safety factor of 2:1. Restraint shall be FM approved in applicable sizes. Restraining device shall be SIGMA ONE-LOK or approved equal. SIGMA Corporation 700 Goldman Drive Cream Ridge, NJ 08514 800 999 2550 p www.sigmaco.com 609 758 1163 f crm-sales@sigmaco.com SIGMA Corporation www.sigmaco.com 1
ONE-LOK Series SLC/SLCE Restraint for AWWA The SIGMA ONE-LOK Series SLC detail for Dimensions in Inches, Weight in Pounds Weight (lbs) DI OD IPS OD Dimensions (in) Wedge Bolt Pressure Rating BC D T No Length (in) Torque PC100 PC150 PC200 3 SLC3 9 3.5 6.19 7.69 0.62 4 7/8 1.5 45-55 100 150 200 4 SLC4 11 4.8 4.5 7.5 9.12 0.75 4 7/8 2.86 45-55 100 150 200 6 SLC6 12 6.9 6.625 9.5 11.12 0.88 6 7/8 2.86 45-55 100 150 200 8 SLC8 19 9.0 8.625 11.75 13.37 1.00 6 7/8 2.86 45-55 100 150 200 10 SL10 25 11.1 10.75 14 15.62 1.00 8 7/8 2.86 45-55 100 150 200 12 SLC12 30 13.2 12.75 16.25 17.88 1.00 8 7/8 2.86 45-55 100 150 200 The SIGMA ONE-LOK Series SLCE detail for Dimensions in Inches, Weight in Pounds Weight (lbs) DI OD IPS OD Dimensions Bolts and Inserts Pressure Rating C F K2 T P P* X J No Torque PC100 PC150 PC200 3 SLCE3 D-SLCE3 6.21 3.50 4.76 3.60 7.18 0.60 9.42 8.50 0.750 6.14 2 7/8 45-55 100 100 100 4 SLCE4 D-SLCE4 6.78 4.80 4.50 5.92 4.90 7.92 0.60 10.22 9.30 0.875 7.50 2 7/8 50-60 100 100 100 6 SLCE6 D-SLCE6 10.28 6.90 6.63 8.01 7.00 10.00 0.60 12.87 11.95 0.875 9.50 3 7/8 50-60 100 100 100 8 SLCE8 D-SLCE8 14.48 9.05 8.63 10.17 9.15 12.18 0.75 14.37 13.45 0.875 11.75 4 7/8 50-60 100 100 100 10 SLCE10 D-SLCE10 21.40 11.10 10.75 12.22 11.20 14.60 0.85 16.68 15.76 0.875 14.00 6 7/8 50-60 100 100 100 12 SLCE12 D-SLCE12 26.96 13.20 12.75 14.32 13.30 16.64 0.85 18.58 17.66 0.875 16.25 8 7/8 50-60 100 100 100 Note: These products offer 2:1 safety rating for rated pressure Installation Instructions for ONE-LOK SCL/SLCE on 1. Clean the fitting socket and pipe end. Lubricate gasket and pipe end with soapy water (or approved pipe lubricant meeting AWWA C111). Install ONE-LOK restrainer on the pipe with the lip extension facing the pipe end, followed by the proper mechanical joint gasket, tapered side toward pipe end. Insert pipe into the fitting outlet and seat the gasket firmly and evenly into the gasket cavity. Maintain a straight joint during assembly. 2. Push the ONE-LOK gland toward the fitting and center it around the pipe with the lip evenly pressed against the gasket. Insert the T-bolts and hand tighten in an alternating manner maintaining an even gap between the gland and the fitting face at all points around the socket. Continue tightening until all the T-bolts are within the suggested torque per AWWA C111, latest revision. Use of a torque wrench is recommended. Following proper assembly of the mechanical joint, hand tighten all actuating bolts until complete contact of the wedge segments is made with the pipe. Caution: Overtighting T-bolts may compromise integrity of joint. 3. Tighten each actuating bolt clockwise, ALTERNATING BETWEEN BOLTS (star pattern) until all the breakaway tops have been removed. Never tighten an actuating bolt more than 180 degrees before moving to the next bolt. If removal is necessary use the remaining 5/8 hex heads. In the absence of the breakaway tops, tighten all actuating bolts using the residual hex shank until the metal bolt collars bottom out in the gland housing. If the SLCE is removed from the pipe, be sure all of the bolts and wedge segments are in place before the SLCE restrainer is reassembled. 2 SIGMA Corporation www.sigmaco.com
PV-LOK Series PVM/PWM Restraint for AWWA The PV-LOK Restraint Systems can successfully be used for the restraint of Molecular Oriented PVC s manufactured in accordance with AWWA. Rated pressure of the restraint is limited to the rated pressure of the PVC pipe. Sample Specification for Restraint: Use the SIGMA PV-LOK Series PV-LOK restraint for AWWA pipe at mechanical or pipe bell and spigot joints. Restraint devices for joining plain end PVC pipe to either mechanical joint or push-on joint shall consist of a split retainer ring that incorporates a series of machined serrations (not as cast ) that provide positive restraint, exact fit and full support of the pipe wall. The restraint device shall provide the necessary bolts and nuts to complete the watermain fitting assembly. Devices shall carry a minimum 2:1 safety factor and meet or exceed the recognized testing for restrained joints on PVC pressure pipe and offer factory certification and independent test results. Restraint devices for securing PVC pipe to mechanical joint/push-on joint watermain fittings shall be SIGMA PV-LOK Series PVM/PVP/PVPF/PWM/PWP/PWPF or approved equal. Material: Clamping ring is manufactured of high strength ductile iron in accordance with ASTM A536, grade 65-45-12. Side clamping bolt and hex nuts are high strength steel in accordance with ASTM A449 and zinc plated to B633, Type III Sc.1 for corrosion resistance. Extra long T-head bolts and nuts are high strength, low alloy steel in accordance with AWWA/ANSI C111/A21.11. Restraining rods and heavy hex nuts are of high strength, low alloy steel in accordance with AWWA/ANSI C111/A21.11. T-head bolts and restraining rods provide minimum 45,000 psi yield and 60,000 psi tensile strength. SIGMA Corporation www.sigmaco.com 3
PV-LOK Series PVM/PWM Restraint for AWWA PVM SERIES (for to Mechanical Joints) details w/ D.I. w/steel Restraining Nuts for Restraining Clamping A B C No x Length No Bolts & Nuts O.D. O.D. (max) (Each Clamp) Torque 2 N/A PVM-S2 2.375 1 1/4 6 1/4 4.0 2 5/8x5 4 5/8 2 5/8x4 85 3 N/A PVM-S3 3.50 1 1/4 7 11/16 4.0 2 5/8x5 4 5/8 2 5/8x4 85 4 PVM-C4 4.80 PVM-S4 4.500 1 1/4 9 1/8 6.00 2 3/4x7 4 3/4 2 5/8x4 100 6 PVM-C6 6.90 PVM-S6 6.625 1 1/4 11 3/4 6.00 2 3/4x7 4 3/4 2 5/8x4 100 8 PVM-C8 9.05 PVM-S8 8.625 1 1/2 14 1/8 6.00 2 3/4x7 4 3/4 2 3/4x4 1/2 100 10 PVM-C10 11.10 PVM-S10 10.750 1 3/4 16 7/8 8.00 4 3/4x9 8 3/4 2 7/8x5 125 12 PVM-C12 13.20 PVM-S12 12.750 1 3/4 19 1/4 8.00 4 3/4x9 8 3/4 2 7/8x5 125 PVP SERIES (for Bell & Spigot Joints) details w/d.i. w/steel Restraining Nuts for Restraining Clamping A B C No x Length No Bolts & Nuts O.D. O.D. (max) (Each Clamp) Torque 2 N/A PVP-S2 2.375 1 1/4 6 1/4 10.0 2 5/8x12 4 5/8 4 5/8x4 85 3 N/A PVP-S3 3.500 1 1/4 7 11/16 10.0 2 5/8x12 4 5/8 4 5/8x4 85 4 PVP-C4 4.80 PVP-S4 4.500 1 1/4 9 1/8 13.0 2 3/4x15 4 3/4 4 5/8x4 100 6 PVP-C6 6.90 PVP-S6 6.625 1 1/4 11 3/4 13.0 2 3/4x15 4 3/4 4 5/8x4 100 8 PVP-C8 9.05 PVP-S8 8.625 1 1/2 14 1/8 13.0 2 3/4x15 4 3/4 4 3/4x4 1/2 100 10 PVP-C10 11.10 PVP-S10 10.750 1 3/4 16 7/8 16.0 4 3/4x18 8 3/4 4 7/8x5 125 12 PVP-C12 13.20 PVP-S12 12.750 1 3/4 19 1/4 22.0 4 3/4x24 8 3/4 4 7/8x5 125 PVPF Series (for joining to PVC Pressure Fittings) details w/d.i. w/steel Restraining Nuts for Restraining Clamping A B C No x Length No Bolts & Nuts O.D. O.D. (max) (Each Clamp) Torque 2 N/A PVPF-S2 2.375 1 1/4 6 1/4 10.0 2 5/8x12 4 5/8 4 5/8x4 85 3 N/A PVPF-S3 3.500 1 1/4 7 11/16 10.0 2 5/8x12 4 5/8 4 5/8x4 85 4 PVPF-C4 4.80 PVPF-S4 4.500 1 1/4 9 1/8 13.0 2 3/4x15 4 3/4 4 5/8x4 100 6 PVPF-C6 6.90 PVPF-S6 6.625 1 1/4 11 3/4 13.0 2 3/4x15 4 3/4 4 5/8x4 100 8 PVPF-C8 9.05 PVPF-S8 8.625 1 1/2 14 1/8 13.0 2 3/4x15 4 3/4 4 3/4x4 1/2 100 10 PVPF-C10 11.10 PVPF-S10 10.750 1 3/4 16 7/8 16.0 4 3/4x18 8 3/4 4 7/8x5 125 12 PVPF-C12 13.20 PVPF-S12 12.750 1 3/4 19 1/4 22.0 4 3/4x24 8 3/4 4 7/8x5 125 *All Dimensions in Inches, Weight in Pounds 4 SIGMA Corporation www.sigmaco.com
PWM Series (for to Mechanical Joint) details PVC w/d.i. A B C (max) Nuts for Res Restraining Clamping Bolts No. No. No. Min Torque 4 PWM-C4 4.80 1.20 9.00 6.00 2 3/4x7 4 3/4 2 5/8x3 3/8 85 7.48 6 PWM-C6 6.90 1.20 11.52 6.00 2 3/4x7 4 3/4 2 5/8x3 3/8 85 8.62 8 PWM-C8 9.05 1.75 12.81 6.00 2 3/4x7 4 3/4 2 3/4x3 7/8 100 13.90 10 PWM-C10 11.10 1.75 16.88 8.00 4 3/4x9 8 3/4 2 7/8x4 3/8 125 21.83 12 PWM-C12 13.20 1.75 19.12 8.00 4 3/4x9 8 3/4 2 7/8x4 3/8 125 24.95 Weight (lb) PWP Series (for Bell & Spigot Joints) details PVC w/d.i. A B C (max) Restraining Nuts for Res Clamping Bolts No. No. No. Min Torque Weight (lb) 4 PWP-C4 4.80 1.20 9.00 13.00 2 3/4x15 4 3/4 4 5/8x3 3/8 85 14.36 6 PWP-C6 6.90 1.20 11.52 13.00 2 3/4x15 4 3/4 4 5/8x3 3/8 85 16.44 8 PWP-C8 9.05 1.75 12.81 13.00 2 3/4x15 4 3/4 4 3/4x3 7/8 100 27.00 10 PWP-C10 11.10 1.75 16.88 16.00 4 3/4x18 8 3/4 4 7/8x4 3/8 125 44.40 12 PWP-C12 13.20 1.75 19.12 22.00 4 3/4x24 8 3/4 4 7/8x4 3/8 125 50.64 Note: These products offer 2:1 safety rating for rated pressure Pressure Rating Chart Pressure Rating PC100 PC150 PC200 3 4 6 8 10 12 *All Dimensions in Inches, Weight in Pounds SIGMA Corporation www.sigmaco.com 5
PV-LOK Series PVM/PWM Restraint for AWWA Installation Instructions for PV-LOK PVM/PWM on 1. Install plain-end PVC pipe into the mechanical joint bell. Insert one of the extra-long T-bolts provided with Series PWM through one of the bolt holes, marking a reference line on the pipe approximately 1 to 2 inches from the end of the bolt. 2. Assemble the MJ gland, gasket and bolts to AWWA standards. Assemble PWM clamping ring on the pipe at the reference line. Tighten the side clamping bolts to recommended torque. The protrusions on the restrainer ears must face the fitting to insure proper direction of the angled serrations. Line up the ears with the corresponding MJ bolt holes. 3. Insert the extra-long T-bolts and install one nut each between the gland and the clamping ring. Tighten the nuts against the MJ gland to AWWA standards to complete the gasketed assembly. Caution: Overtighting T-bolts may compromise integrity of joint. 4. Snug the retaining nuts behind the restrainer ears (against the flat surface). Do not over-tighten retaining nuts, approximately one turn with a wrench. Installation Instructions for PV-LOK PVP/PWP on 1. Assemble plain-end PVC pipe into bell according to pipe manufacturer s recommendations. 2. Assemble the Series PVP clamping rings on the spigot pipe (approx. 2 inches behind the insertion mark on the pipe) and immediately behind the pipe bell end, making sure the protrusions on the restrainer ears face toward each other to insure proper direction of the angled serrations. Tighten the side clamping bolts to recommended torque. 3. Insert the restrainer rods provided and snug the retaining nuts against the restrainer ears (against the flat surface). Do not over-tighten retaining nuts, approximately one turn with a wrench. Installation Instructions for PV-LOK PVPF on 1. Assemble plain-end PVC pipe and PVC pressure fitting according to pipe manufacturer s recommendations. 2. Install the non-serrated, two-piece interlocking ring set behind the gasketed bell of the PVC fitting. The bevel of this ring set should face the end of the fitting, allowing the retainer ring to seat evenly against the fitting bell. 3. Insert the restrainer rods through the retainer ear back toward the pipe and mark a reference line approximately two inches in from the rod end. Install the serrated clamping ring at this mark, making sure the protrusions on the restrainer ears face toward the fitting bell to insure proper direction of the angled serrations. Tighten the side clamping bolts to recommended torque. 4. Insert the restrainer rods provided and snug the retaining nuts behind the ears on both the clamping ring (against the flat surface) and back-up ring. Do not over-tighten retaining nuts, approximately one turn with a wrench. 6 SIGMA Corporation www.sigmaco.com