Structural UT: Variables Affecting Attenuation and Review of the 2 db per Inch Model

Similar documents
Modelling Probe Wedge and Pipe Geometry as Critical Parameters in Pipe Girth Weld Ultrasonic Inspections Using Civa Simulation Software

Phased Array Inspection of Coarse Grain Welds (Austenitic, CRA, etc)

Optimized Semi-Flexible Matrix Array Probes for Large Rotor Shafts and DGS Sizing Diagram Simulation Tool

DACON INSPECTION SERVICES. Phased Array Ultrasonic Testing

Variables to consider in the fabrication of ultrasonic reference blocks

DESIGN & VALIDATION OF A SEMI-FLEXIBLE PAUT PROBE FOR THE MANUFACTURING INSPECTIONS OF LARGE FORGED ROTORS

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

S. GURESH 4 JAN 2017 S. JOHNSON 4 JAN 2017

Curved arrays for improved horizontal sizing in small pipe welds

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

PHASED ARRAYS FOR SMALL DIAMETER, THIN-WALLED PIPING INSPECTIONS

The Application of TOFD Technique on the Large Pressure Vessel

Nondestructive Evaluation Tools to Improve the Inspection, Fabrication and Repair of Bridges

Performance of UT Creeping Waves in Crack Sizing

Novel Imaging Techniques for Defects Characterisation in Phased Array Inspection

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Ultrasonic testing Characterization of indications in welds

PROPOSED CHANGES TO: APPENDIX IV - PHASED ARRAY E-SCAN AND S-SCAN MANUAL RASTER EXAMINATION TECHNIQUES

Automated Ultrasonic Inspection for Pipeline Girth Welds

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

12/26/2017. Alberto Ardon M.D.

BASICS ULTRASONIC TESTING METHOD. -Dr.Oruganti Prabhakar Proprietor-OP-TECH

UNIVERSAL ULTRASONIC FLAW DETECTOR UD4-76. TOFD version.

Standard Guide for Evaluating Performance Characteristics of Phased-Array Ultrasonic Testing Instruments and Systems 1

Probability of Rejection - In conformance with DNV OS F101

Latest Developments for Pipeline Girth Welds using 3D Imaging Techniques. Novel Construction Meeting Jan van der Ent March 2016, Geneva

Standard Practice for Ultrasonic Examination of Turbine and Generator Steel Rotor Forgings 1

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Govt. of India Enterprise)

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

TOFD Analysis Flaw Sizing and Characterization

ASNT Level III Study Guide: Ultrasonic Testing Method, second edition Errata 1st Printing 09/13

Pipeline Girth Weld Inspections using Ultrasonic Phased Arrays Michael Moles, Noël Dubé, Simon Labbé and Ed Ginzel

Manual UT vs PIMS (Permanently installed monitoring sensors)

Ultrasonic Guided Wave Testing of Cylindrical Bars

A COMPARISON BETWEEN ASTM E588 AND SEP 1927 RELATING RESOLUTION LIMITS AT DETERMINATION OF THE PURITY GRADE

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Tom Marshall, Sonatest Ltd. Date: March 15, Typical Application. Introduction. Using the veo with the Phoenix Bracelet Scanner

GB/T Translated English of Chinese Standard: GB//T NATIONAL STANDARD OF THE

Weld gap position detection based on eddy current methods with mismatch compensation

A CONTRIBUTION TO QUANTIFYING THE SOURCES OF ERRORS IN PAUT

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0) Fax:++972-(0)

Multi-Parameter POD for Industrial Applications The Influence of the Material Attenuation as an Example

An Investigation into the Performance of Complex Plane Spilt Spectrum Processing Ultrasonics on Composite Materials

2010 ULTRASONIC BENCHMARKS

Improved Inspection of CRA-Clad Pipeline Girth Welds with the Use of Accessible Advanced Ultrasonic Phased-Array Technology

Implementation of electromagnetic acoustic resonance in pipe inspection

NDT-PRO Services expands service offering

GUIDELINES FOR THE APPLICATION OF TIME-OF-FLIGHT DIFFRACTION (TOFD) AND PHASED ARRAY ULTRASONIC TESTING (PAUT) TECHNIQUES

Table 1 The wheel-set security system of China high-speed railway

Film Replacement in Radiographic Weld Inspection The New ISO Standard

NDI Techniques Supporting Steel Pipe Products

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel. Portable Ultrasonic Phased Array Flaw Detector and Recorder

Introduction To NDT. BY: Omid HEIDARY

Use of Lamb Waves High Modes in Weld Testing

Effect of coupling conditions on ultrasonic echo parameters

Attenuation and velocity of ultrasound in solid state materials (transmission)

Basic functions of the universal flaw detector GEKKO

Adhesive Thickness Measurement on Composite Aerospace Structures using Guided Waves

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

Development of Automatic Neural Network Classifier of Defects Detected by Ultrasonic Means

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO

ULTRASONIC SIGNAL CHARACTERIZATIONS OF FLAT-BOTTOM HOLES IN

Phased Array Velocity Sensor Operational Advantages and Data Analysis

BINDT Telford. Guided Wave Testing and Monitoring Over Long and Short Ranges

Ultrasonic Testing using a unipolar pulse

Long Range Ultrasonic Testing - Case Studies

The Quantitative Study of TOFD influenced by the Frequency Window of Autoregressive Spectral Extrapolation

Phased Array&TOFD Probes

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing

Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

Reference Standards Calibration Blocks

EE 422G - Signals and Systems Laboratory

Developments in Ultrasonic Phased Array Inspection III

ULTRASONIC FLAW DETECTOR +TOFD VERSION. CE MARKING EN Compliant

ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

Reference wavelets used for deconvolution of ultrasonic time-of-flight diffraction (ToFD) signals

ISONIC Superior Performance Portable Smart All-In-One Ultrasonic Flaw Detector and Recorder with A-, B-, CB-Scan, and TOFD Functionality

CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE. Wolfgang Gebhardt and Friedhelm Walte

Ultrasonic Examination Of Tube To Tube Sheet Weld Joints In High Pressure Heat Exchanger For The Urea Process

Developments in Ultrasonic Guided Wave Inspection

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

A Turnkey Weld Inspection Solution Combining PAUT & TOFD

Application of Guided Wave Technology to Tube Inspection

18th World Conference on Non-destructive Testing, April 2012, Durban, South Africa

DETECTING DEFECTS by Larry Adams, senior editor. Finding flaws and imperfections in a tube or pipe is made easier using new inspection technologies

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

Dave Stubbs, Wally Hoppe, and Bob Olding. NDE Systems Division Systems Research Laboratories, Inc. Dayton, Ohio

SUPPERIOR MODERN PERFORMANCE

This British Standard, having been prepared under the direction of the Iron and Steel Standards Policy Committee, was published under the authority of

Isolation Scanner. Advanced evaluation of wellbore integrity

Imaging using Ultrasound - I

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Transcription:

Structural UT: Variables Affecting Attenuation and Review of the 2 db per Inch Model Paul Holloway, P.Eng, MASc, CGSB UT3 MT2 President, Holloway NDT & Engineering Inc. Purpose & Practical Applications The North American standards for welded steel construction, CSA W59 [1] and AWS D1.1 [2], use an approximation for ultrasonic attenuation of 2dB/in. This approximation is based on the use of large, low frequency transducers which are not always well-suited to the wide range of weld thicknesses and geometries used in the codes. This paper documents computer simulations and experimental results performed to gauge the suitability of this linear factor to approximate a non-linear phenomenon. Additionally, models of smaller transducers and higher frequencies are included to study their effect. This is performed to determine how alternate criteria and procedures may be developed to retain the same levels of sensitivity but expand the range of transducers beyond that currently permitted. Background Instructions exist in CSA W59 and AWS D1.1 to establish the reference level based on the response from a target commonly available to all UT operators. The target is the 1.5 mm diameter side-drilled hole (SDH) located 15 mm below the test surface of the IIW-Type block (see Figure 1). This is referred to as the standard reference reflector. The response from this target is then set to a procedurally defined screen Figure 1 height (typically 50%) and that amplitude is then considered the reference amplitude. A formula is used to calculate the indication rating taking into consideration the indication amplitude, the reference amplitude, and attenuation due to beam divergence and material attenuation (Eq. 1). D = A - B - C (1) Where: A = indication level B = reference level C = attenuation factor D = indication rating The attenuation factor C is calculated using either formula in Eq. 2a or 2b. mm (2a) inches (2b) The assumption in these equations is that attenuation does not begin until the sound has traveled 25mm (1 in). There are no special instructions in either the codes on how to deal with sound path distances less than 25mm, so it is assumed the same equations apply. In those cases (albeit, rare) that an indication were found at such a short sound path distance, the attenuation factor would be negative. A quick review of the application of this equation is shown in the following example: Example Consider the indication shown in Figure 2. The reference level (B) is set at 54.2 db and the indication level is 61.4 db (an additional 7.2 db above reference to bring the signal to 50% FSH). The attenuation factor C is equal to 4.5 db, using Eq. 2a with a sound path distance of 82 mm. Using Eq. 1 to calculate the indication rating D: D = 61.4-54.2-4.5 = +2.7 db The indication rating D would then be compared to the acceptance tables for cyclically or statically loaded structures. Approximating attenuation in steel as a linear constant of 2dB/in makes calibration possible using a single SDH. By comparison, the use of the distance amplitude curve (DAC) or time-corrected gain (TCG) techniques 6 CINDE Journal Vol.38 No.3 May/June 2017 www.cinde.ca

Figure 2 require multiple reference targets and blocks of different thicknesses. The advantages of using one block and a fixed attenuation factor come at the cost of the narrow limits placed on transducer selection, high added scanning gains, and the need to calculate the attenuation factor for every indication. Attenuation is not linear Attenuation is based on three primary factors: scatter, absorption and divergence. Combined losses due to scatter (primarily reflections off grain boundaries) and absorption (conversion to heat) are low in most carbon steels, on the order of 0.01dB/mm in the range of 2-4MHz that is typically used for weld inspections. The loss due to divergence is a result of beam spread, which is primarily a function of transducer size, angle of refraction and frequency. The compensation seen in the CSA and AWS codes is on the order of 0.08dB/mm (2dB/in). This is a factor of 8 larger than the typical material attenuation value, and is made so to account for the effect of divergence. To illustrate the non-linearity of attenuation, CIVA modelling was used to compare the responses from AWS-style rectangular and ½ in diameter round probes at 45, 60 and 70 from a 1.5mm SDH. The standard AWS probe modeled was a broadband, 2.25MHz probe with ⅝ ⅝ in dimensions (the most common size, and also the minimum allowed by code). Also modeled was a probe with dimensions of 1 ¹³ ₁₆ in (the maximum allowed). For comparison, ½ in diameter probes at 2.25MHz and 5 MHz were also modeled. The wedge sound paths modeled were the Olympus Accupath (the big red brick ) ABWS-6 series and the Olympus short approach ABSA-5T series. Responses were obtained from 1.5mm diameter targets at 8mm, 15mm, 20mm, 38mm, 65mm, 100mm and 200mm depths. Simulated targets were arranged in a block of steel with density 7.8g/cc. Acoustic properties included compression velocity of 5900m/s and shear velocity of 3230m/s. The attenuation values were obtained from material assessment using a through transmission technique at a nominal frequency of 5MHz. A power-attenuation law using a power of 2 calculated the attenuation at the nominal 2.25MHz used for the modelled probes. By situating a 1.5mm diameter SDH at 15mm depth, the scan over the targets provides a direct comparison of amplitudes as they would be if using the 15mm deep 1.5mm SDH in the IIW block. The simulated reference block was made 650mm long, 250mm deep and 100mm wide. This accommodated all but the longest scan path required by the 70 beam to reach the target at 200mm depth. See Figure 3 for the Figure 3 Simulated block with 1.5mm diameter SDH targets Figure 4 CIVA data display Top left: A-scan Lower left: echo-dynamic scan Top right: B-scan Lower right: probe on block with B-scan overlay simulated block with a 70 probe near the end of the scan. For each probe size, a separate scan was made using a 45, 60 and 70 beam angle. B-scans were generated and the associated A-scans could be extracted and plotted over the scan path to indicate the peak amplitude at each position (echo-dynamic plots). An example of the plots available is illustrated in Figure 4. The response from the 1.5mm SDH at 15mm depth was then used as the reference and its amplitude set to 0dB. All the other responses in the scan were then compared to the reference. Figure 5 indicates an example where the reference amplitude is established for the second target in the scan (i.e. the 1.5mm SDH at 15mm depth). When all the scans for the three different angles were completed and normalised to the reference target, the values were tabulated. These are graphed in Figure 6 alongside experimental results using an Olympus C430 (5/8 x 5/8 inch, 2.25MHz) transducer on a ¾ inch 1018 steel ASME basic calibration block. Excellent correlation is seen between the modeled and experimental data. A few points regarding the correlation between the experimental and simulated attenuation: The ASME block contained reference holes of 3/32 inch (2.38mm) diameter, larger than the standard 0.060 inch (1.5mm) holes used in the simulations. However, the difference in absolute indication heights is irrelevant as only the relative db differences are graphed. This is further explained in section on target size. www.cinde.ca Vol.38 No.3 May/June 2017 7

Figure 5 Reference target set to zero db Figure 8 2dB/inch versus modeled attenuation of AWS probe at 60 Figure 6 CIVA model and experimental results of attenuation Figure 9 2dB/inch versus modeled attenuation of AWS probe at 70 all three angles (as in Figure 6). A graph of each angle and the relationship to the 2dB/inch estimate is shown in Figure 7, Figure 8 and Figure 9. In the preceding graphs, the simulations and the 2dB/in values are close only at 45 where the maximum difference is around 2dB. At 60 and 70 the differences more than double, up to nearly 6dB for sound paths of 150mm. Figure 7 2dB/inch versus modeled attenuation of AWS probe at 45 In order to obtain reflections over the required sound paths, multiple reflections were required off the top and bottom surfaces of the ASME block. The losses at these surfaces has been shown to be minimal [3]. No compensation was made in the data prior to graphing. We can compare the relative amplitudes to the compensation made by the linear equation in the codes. Each angle incurs a different sound path, so the 2dB/inch line cannot be overlaid on a single graph of amplitude vs. depth for Effect of transducer and target parameters on attenuation Transducer size The size of the transducer element directly affects beam divergence. Beam half-angle is calculated by a Bessel function but can be approximated by the equation [4] : Where: g = half-angle in degrees k = constant (derived from Bessel function) l = wavelength D = diameter of the probe element For round transducer elements, k = 0.51 for the -6 db half angle. For rectangular elements the value of k changes and D is calculated separately 8 CINDE Journal Vol.38 No.3 May/June 2017 www.cinde.ca

Figure 10 Attenuation of min. and max. AWS transducer sizes at 45 degrees Figure 12 Attenuation of min. and max. AWS transducer sizes at 70 degrees Figure 11 Attenuation of min. and max. AWS transducer sizes at 60 degrees for the length and width dimension of the element. Following from Eq. 3, we expect larger transducers to exhibit less beam spread. Less divergence would produce less attenuation. The allowable transducer sizes in the codes ranges from ⅝ ⅝ inch to 1 ¹³ ₁₆ inch, making the surface area of the larger transducer more than double that of the smaller one. The difference between these minimum and maximum transducer sizes was modeled using CIVA and the results for 45, 60 and 70 are shown in Figure 10 to Figure 12. The difference between the curves is very slight, producing a difference of only 2dB at 70 and a depth of 100mm (4 in). A more significant effect of increased probe size is observed in Figure 10. The larger probe has a longer near zone, and as such it appears further to the right on the X-axis. Thus, the 2dB/in model is shown to be less suited for the 1 x 13/16 inch probe than the 5/8 x 5/8 inch. Transducer frequency To examine the effect on attenuation of changing frequency, a second common frequency of 5MHz was modeled and compared. Since AWS transducers are not available at 5MHz, these comparisons were made using ½ in round transducers. Graphs of the results are shown in Figure 13 to Figure 15. As expected, the 5MHz models attenuate at a considerably higher rate, which is apparent Figure 13 Effect of frequency on attenuation (45 ) at longer soundpaths. At 45, the extended near zone effect is clearly seen. At 60, the attenuation of the 5MHz and 2.25MHz are virtually identical up to a depth of 40mm. Refracted angle Increasing the angle has the effect of reducing the transducer height, which in turn increases beam spread and thus attenuation. It is therefore expected that higher angles will exhibit more attenuation. This is evident in both the experimental results and CIVA simulation results (refer to Figure 6). Note: Increasing angle of refraction reduces effective transducer dimension (Dim)eff, thus increasing beam spread Target size CSA and AWS use only the 0.060 inch (1.5 mm) hole, while codes such as ASME Sec. V Article 4 make use of a variety of hole diameters ranging from 3/32 inch (2.5 mm) to 3/16 inch (5 mm) for welds up to 4 inches (100 mm) thick. To demonstrate the effect of side-drilled hole diameter, a simulated 16x16mm probe was scanned over a series of 3mm diameter SDHs in the same positions as was used for the 1.5mm diameter SDHs. Results seen in Figure 17 for 70 (where the maximum difference was seen), indicate that www.cinde.ca Vol.38 No.3 May/June 2017 9

Figure 14 Effect of frequency on attenuation (60 ) Figure 17 Relative amplitude responses of a typical AWS transducer on 1.5mm (red) and 3mm (black) diameter SDHs Figure 15 Effect of frequency on attenuation (70 ) Figure 16 Effect of angle of incidence on beam spread the rate of attenuation is essentially identical. Note that in this figure, the response from the 3mm hole is about 4dB greater than the 1.5mm hole, but the attenuation rate remains unaffected. This data is plotted in Figure 18 where only a 0.8 db difference in attenuation rate was found at a soundpath distance of 65mm. When the comparisons are made with the amplitudes normalised to the 3mm diameter holes the effect is as predicted by Ermolov [5] in that the amplitude difference is a constant value regardless of the soundpath. Figure 18 Attenuation of 1.5mm and 3mm SDH at 70 Conclusions The 2dB/in model has been in effect for nearly 50 years, beginning in AWS D1.0 (1969) Appendix C [6]. A close look at the details of attenuation reveals that the factor is simply an empirical fit that approximates the effect for a typical probe. The model has served industry well for many years, but technology and understanding of ultrasonic physics has long since surpassed the need to restrict users to a one size fits all model. This is especially true, since the 2dB/in model does not model particularly well the transducer size range and angles for which it is intended. The time has come to put North American structural ultrasonic inspection techniques at par with practices used worldwide and revise the techniques and acceptance levels for use of a DAC/TCG for attenuation. By understanding the effects that angle, size and frequency have on attenuation, the impression of the 2dB/in factor on the ultrasonic acceptance levels can be quantified. This permits the development of alternate techniques, adapting the acceptance levels for use of a wide variety of transducers and will produce more repeatable results. As well, alternative hole sizes to the 1.5mm diameter SDH presently used by CSA/AWS are feasible in that they provide an easily calculated difference based on diameter that is consistent over the full range of sound paths for the same probe. 10 CINDE Journal Vol.38 No.3 May/June 2017 www.cinde.ca

Acknowledgements I would like to thank Ed Ginzel for his contributions. Much of this paper was inspired (and directly lifted from) ongoing correspondence between us related to ultrasonic testing. Ed also provided all the CIVA modelling data. References 1. CSA W59 Welded Steel Construction (Metal Arc Welding), CSA Group, Mississauga, Ontario (2013) 2. AWS D1.1: Structural Welding Code Steel, American Welding Society, Miami, Florida (2015) 3. Ginzel, E., Petersen, B., Civa Modelling of Distance Amplitude Correction Curves on Flat Calibration Blocks, NDT.net Vol.20 No.5, (May 2015) 4. IAEA, Ultrasonic Testing of Materials at Level 2, IAEA-TECDOC-462, International Atomic Energy Agency, Vienna (1988) 5. Ermolov, I.N. The reflection of ultrasonic waves from targets of simple geometry, Non-Destructive Testing, Vol.5 Issue 2, pp 87-91, (April 1972) 6. Shenefelt, G.A., "Ultrasonic Testing: Requirements of the AWS 1969 Building Code and Bridge Specifications", Welding Journal, (May 1971) Paul Holloway is a Professional Engineer, CGSB UT3 MT2 and PCN Level 2 Phased Array. He is the President of Holloway NDT & Engineering Inc., a company specializing in onshore and offshore ultrasonic testing field services, NDT training and consulting, and Mechanical Engineering services. Industries served include petrochemical and power generation markets, construction, manufacturing, automotive and aerospace. He received his Master of Applied Science degree in Mechanical Engineering from the University in Waterloo in 2004. He is also an active member of the CSA W59 committee. Paul still drinks Starbucks French Roast, black. Paul Holloway Georgetown, ON Canada paul@hollowayndt.com (905) 703-0201 www.hollowayndt.com INNOVATION THAT DELIVERS RESULTS. EXPERIENCE NDT INSPECTIONS THAT ARE MORE PRODUCTIVE, MORE EFFICIENT TOPAZ PHASED ARRAY ULTRASONIC INSTRUMENTS Zetec www.zetec.com NDT PAINTBRUSH SCANNER MIZ -200 EDDY CURRENT INSTRUMENT SURFACE ARRAY FLEX PROBE Zetec s complete line of eddy current and ultrasonic product solutions are built on nearly 50 years of innovation. When your inspections require accuracy and efficiency, Zetec solutions deliver results. Visit us at NDT Canada Conference, Booth 8 For more information, visit www.zetec.com 2017 Zetec Inc. All rights reserved. Zetec, MIZ, TOPAZ and NDT PaintBrush are trademarks or registered trademarks of Zetec in the United States and/or other countries. www.cinde.ca Vol.38 No.3 May/June 2017 11