Easy-to-Use RF Device & User-Friendly Windows Software

Similar documents
Easy-to-Use RF Device & User-Friendly Windows Software

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

Compact VNA - TR1300/1

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

R&S ZVT Vector Network Analyzer Specifications

HMC-T2240. Synthesized Signal Generator, 10 MHz to 40 GHz

Cobalt Series 20 GHz EXTEND YOUR REACH TM

Vector Network Analyzers ZVB

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

R&S ZVT Vector Network Analyzer Specifications

Reconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth

M5090. Extended Specifications EXTEND YOUR REACH TM

APPH6040B / APPH20G-B Specification V2.0

1-Port USB VNA - R60 Extended Specifications

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

Arbitrary/Function Generator AFG1000 Series Datasheet

Model 7000 Series Phase Noise Test System

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

OCXO 8600 BVA Oven Controlled Crystal Oscillator

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

Your Network. Optimized.

DCNTS Phase Noise Analyzer 2 MHz to 1.8 / 26 / 50 / 140 GHz

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

THE CRYSTAL OSCILLATOR CHARACTERIZATION FACILITY AT THE AEROSPACE CORPORATION

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

R&S ZNC Vector Network Analyzer Specifications

Agilent 4-Port PNA-L Microwave Network Analyzer

Impedance 50 (75 connectors via adapters)

PXIe Contents. Required Software CALIBRATION PROCEDURE

2026Q CDMA/GSM Interferer MultiSource Generator

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

J kw AM Transmitter

DG4000 Series Waveform Generators

Contents. CALIBRATION PROCEDURE NI PXIe GHz and 14 GHz RF Vector Signal Analyzer

PLANAR S5048 and TR5048

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

FS5000 COMSTRON. The Leader In High Speed Frequency Synthesizers. An Ideal Source for: Agile Radar and Radar Simulators.

VXIbus Local Oscillator

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

Clock Measurements Using the BI220 Time Interval Analyzer/Counter and Stable32

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

PLANAR 814/1. Vector Network Analyzer

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

R&S ZNB Vector Network Analyzer Specifications

FREEDOM Communications System Analyzer R8000C DATA SHEET

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

IZT R3600. Product Brochure. Version 1.1

Rockwell Collins, Inc. VHF Users Manual

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

R&S ZV-Z5x Calibration Units Specifications

Chapter 5 Specifications

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

ExacTime GPS Time & Frequency Generator

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

Models FSW-0010 FSW-0020

FREEDOM Communications System Analyzer R8100 DATA SHEET

R&S ZNBT8 Vector Network Analyzer Specifications

Spectrum Analyzer R&S FS300

SPECIFICATION. DVB-C / Worldwide NIM Tuner

khz to 2.9 GHz Spectrum Analyzer

Advanced Test Equipment Rentals ATEC (2832)

S3602A/B Vector Network Analyzer Datasheet

Maximum output frequency:160 MHz, 100 MHz, 60 MHz 500MSa/s sample rate, 14 bits vertical resolution Dual Channel Outputs With Identical Performance

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

ArbStudio Arbitrary Waveform Generators

Measurement of the equivalent circuit of quartz crystals

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Phase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On

Agilent 81180A Arbitrary Waveform Generator

Reflectometer Series:

GPS Time and Frequency Reference Receiver

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

Jitter Measurements using Phase Noise Techniques

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

DSA700 Series Spectrum Analyzer

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

FREEDOM Communications System Analyzer R8000C DATA SHEET

2.7 GHz FREQUENCY COUNTER with TCXO

FREEDOM Communications System Analyzer R8600 DATA SHEET

Spectrum Analyzers U3771/3772. Handling frequencies of up to 43 GHz!! Our new microwave spectrum analyzer, ideal for field use, is now available.

R3132/3162. Advanced Test Equipment Rentals ATEC (2832) R3132 : 9kHz to 3GHz R3162 : 9kHz to 8GHz

The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections.

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

Signal Sources. 2026Q CDMA Interferer Multisource Generator. Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Datasheet SHF D Synthesized Clock Generator

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function

Transcription:

itest+ PicoTime-1U Spec November 30, 2015 Low Cost/Profile High Resolution Frequency Stability Measurement Test Set Pico Second Resolution Instrument Easy-to-Use RF Device & User-Friendly Windows Software APPLICATIONS Calibration Oscillator/Clock Characterization TIE Measurements Lab Instrument sales@spectratime.com Switzerland Headquarters North America Sales Office Specifications are subject to change without prior notice

PicoTime-1U Product Characteristics Power supply voltage Compact DUT Frequency Range Reference Frequency Phase time resolution and noise Input Signal Level No calibration required Port Software Main Features : AC input 85-264VAC / 47-63Hz : 1U rack mount chassis : 1 MHz 30 MHz : 10 MHz : 2ps rms : +3dBm to +17dBm : Standard PC (COM1 to COM4) : Windows 7, Windows XP Main Applications Easy to use Small volume High resolution COM standard interface Automatic operation Low noise performance External counter compatible User friendly software Clock characterization such as crystal and rubidium oscillators and cesium source. Short term stability measurements Phase comparator Network Time Interval Error (TIE) Calibration of quartz crystal oscillator, and atomic clocks System Description The system is designed to make a direct frequency measurement in comparison with an external 10 MHz frequency reference. PicoTime-1U is based on a heterodyne system using direct digital synthesizer (DDS) technology to allow measurements in the range of up to 30 MHz. The external 10MHz reference divided by 2x10 7 is used to make time interval measurement each second Direct frequency measurement is used for programming DDS. The DDS divides the device frequency around 1KHz by using two mixers. As indicated in the block-diagram, the whole system is based on a heterodyne architecture with a double frequency conversion. Three outputs are available: - 1KHz where a crystal filter based PLL is used to restrict the bandwidth to only 1Hz - 1KHz with about several 100KHz bandwidth. - 1PPS reference The system is controlled with the PC COM interface. When connecting an external counter, other types of measurements can be performed. sales@spectratime.com Switzerland Headquarters North America Sales Office Page 2 of 7

F DUT 10MHz ref Mult.12 DDS1 DDS2 Div. 32 Div.1E7 BP LP XTAL 1KHz filtered 1KHz 1PPS ref Time interval counter External counter Fig.1 : Block diagram sales@spectratime.com Switzerland Headquarters North America Sales Office Page 3 of 7

Fig 2 : System Noise in ideal conditions sales@spectratime.com Switzerland Headquarters North America Sales Office Page 4 of 7

Fig.3 : Mechanical drawing sales@spectratime.com Switzerland Headquarters North America Sales Office Page 5 of 7

SPECIFICATIONS ELECTRICAL DUT Center Frequency Range 1 MHz 30 MHz Measurement Noise in filtered mode (1Hz < 2ps bandwidth)@10mhz (Maximum Relative Frequency Deviation During Measurements < 10-9 ) Measurement Noise in unfiltered mode (> 3 KHz < 10ps bandwidth) @10MHz (Maximum Relative Frequency Deviation During Measurements < 10-7 ) Reference Frequency 10 MHz Typical System Noise @10MHz See typical measurement fig. 2 ( 0.5 C very low temp. Change during measurement) Phase time sensitivity versus temperature < 20ps / C Input Signal Level +3 dbm to 17 dbm Input Impedance 50 Ohms Connector BNC grounded to chassis & earth PC Port Standard Serial (COM1 or COM2 or COM3 or COM4) ENVIRONMENT Temperature Relative Humidity Operating 15 to 30 C 10% - 85% Storage -25 to 55 C Transportation -25 to 70 C POWER REQUIREMENTS Power Supply AC input 85-264VAC Power Input Fluctuation Input Frequency Power Consumption @25 C Connector 10% of nominal supply voltage (230V~) 47 63 HZ < 10W after warm-up IEC plug PHYSICAL Size Weight Mounting UNIT SUPPLY 445 x 300 x 44 mm (1U) 3.5 Kg Tabletop feet Option: 19 rack mountable ears (ordering code: E) Instrument unit Cable SUB-D male/female for PC serial COM Software installation Software Stable32 (Option code ST32) Operating Manual + Specifications US Power Cable (ordering code: US) China Power Cable (ordering code: CN) Euro Power Cable Standard Swiss Power Cable (ordering code: CH) Indian Power Cable (ordering code: IN) sales@spectratime.com Switzerland Headquarters North America Sales Office Page 6 of 7

SOFTWARE UPGRADES Download the latest software upgrades at http://www.spectratime.com Ordering Information PicoTime-1U / ST32 Stable32 sales@spectratime.com Switzerland Headquarters North America Sales Office Page 7 of 7